This paper sums up the determining analysis of the measuring location of Treflusing a thermocouple during the thermography tests.Laboratory temperature distribution testing methods,analysis of value and location of Tre...This paper sums up the determining analysis of the measuring location of Treflusing a thermocouple during the thermography tests.Laboratory temperature distribution testing methods,analysis of value and location of Treflmeasurement are explained in this paper.The heat source is two halogen lamps of 500 watts eachfitted at a distance of 30–50 cm.Noises appearing during testing of thermography are corrected with measured T_(refl) value.The results of thermogram correction of corroded concrete surfaces using T_(refl) values are displayed in this paper too.The concrete surface temperature results of quantitative image processing method are compared to the experimental test results.The results showed good accuracy,which was seen from most errors<3%and the maximum error is<5%.The end of paper,explained of application Treflvalue to the corroded reinforced concrete thermogram.展开更多
在应用真空荧光环氧浸渍技术得到含微裂纹的混凝土显微图像的基础上,基于MATLAB搭建开发了由二值化、形状分析、骨架化和自动测量4个模块组成的混凝土微裂纹定量分析软件QUANSIMIC(quantitative analysis system of microcracks in conc...在应用真空荧光环氧浸渍技术得到含微裂纹的混凝土显微图像的基础上,基于MATLAB搭建开发了由二值化、形状分析、骨架化和自动测量4个模块组成的混凝土微裂纹定量分析软件QUANSIMIC(quantitative analysis system of microcracks in concrete),可实现微裂纹区域的识别、提取以及面积、长度及宽度等二维结构特征参数的测量分析.其中二值化模块中采用Intermodes法确定灰度阈值进行微裂纹区域的识别和提取;形状分析模块中分别采用开操作去除噪声,采用长宽比为2.0的判别准则区分孔隙与裂纹;在自动测量模块中的长度计算时考虑了微裂纹骨架的宏观倾角,相对误差很低.展开更多
基金This research was supported by the P3MI Research Grants.Thanks to Prof.Herlien D Setio as authors who received the grant.
文摘This paper sums up the determining analysis of the measuring location of Treflusing a thermocouple during the thermography tests.Laboratory temperature distribution testing methods,analysis of value and location of Treflmeasurement are explained in this paper.The heat source is two halogen lamps of 500 watts eachfitted at a distance of 30–50 cm.Noises appearing during testing of thermography are corrected with measured T_(refl) value.The results of thermogram correction of corroded concrete surfaces using T_(refl) values are displayed in this paper too.The concrete surface temperature results of quantitative image processing method are compared to the experimental test results.The results showed good accuracy,which was seen from most errors<3%and the maximum error is<5%.The end of paper,explained of application Treflvalue to the corroded reinforced concrete thermogram.
文摘在应用真空荧光环氧浸渍技术得到含微裂纹的混凝土显微图像的基础上,基于MATLAB搭建开发了由二值化、形状分析、骨架化和自动测量4个模块组成的混凝土微裂纹定量分析软件QUANSIMIC(quantitative analysis system of microcracks in concrete),可实现微裂纹区域的识别、提取以及面积、长度及宽度等二维结构特征参数的测量分析.其中二值化模块中采用Intermodes法确定灰度阈值进行微裂纹区域的识别和提取;形状分析模块中分别采用开操作去除噪声,采用长宽比为2.0的判别准则区分孔隙与裂纹;在自动测量模块中的长度计算时考虑了微裂纹骨架的宏观倾角,相对误差很低.