This article uses real engineering projects as examples to analyze how static load test technology is applied in testing the bridge-bearing capacity.The analysis covers aspects such as testing section layout,test load...This article uses real engineering projects as examples to analyze how static load test technology is applied in testing the bridge-bearing capacity.The analysis covers aspects such as testing section layout,test load and efficiency coefficient,loading plan,evaluation optimization,test result modification,and result evaluation.The aim is to support the accurate detection and evaluation of bridge-bearing capacity.展开更多
Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous ...Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous components offer alternatives that may avoid such failures.A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics.Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used.However,a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported.In this study,a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing.Critical joints were designed and verified.Numerical models were established and calibrated to estimate frame shear forces.The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms.Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall.Drift distribution becomes more uniform with height.Concrete cracks and damage occurs in desired areas.The infilled rocking wall frame offers a promising approach to achieving seismic resilience.展开更多
Highway bridges are an important part of the transportation industry and can promote social economic construction and development.In actual operation,highway bridges are often damaged due to overload and natural facto...Highway bridges are an important part of the transportation industry and can promote social economic construction and development.In actual operation,highway bridges are often damaged due to overload and natural factors,which tend to affect the safety and shorten the service life of these bridges.Assessing the overall state and performance of highway bridges is therefore a key element.Static load test,which is a type of sustainable detection experiment,has many advantages,including low cost,high efficiency,and high accuracy.In this paper,the bridge structure is analyzed through the application of theoretical calculations and relevant comparisons,so as to judge the operating state of the bridge.展开更多
The quality of the continuous rigid-frame railway bridge is related to the safety of train operation,so it is necessary to test its stiffness,strength,and other indicators.Static load test is a common technique for br...The quality of the continuous rigid-frame railway bridge is related to the safety of train operation,so it is necessary to test its stiffness,strength,and other indicators.Static load test is a common technique for bridge inspection.This article summarizes the purpose of the static load test for a continuous rigid-frame railway bridge,including the required equipment,operation methods,etc.,and lists examples to analyze the operation process and precautions of static load test,hoping to provide reference information for relevant personnel.展开更多
A device for supporting soft rock masses combined with a constant resistance structure characterized by constant resistance and large deformation at the end of a steel bar, known as the constant resistance and large d...A device for supporting soft rock masses combined with a constant resistance structure characterized by constant resistance and large deformation at the end of a steel bar, known as the constant resistance and large deformation(CRLD) bolt, has recently been developed to counteract soft rock swelling that often occurs during deep mining. In order to further study the mechanical properties of the CRLD bolt, we investigated its mechanical properties by comparison with the conventional strength bolt(rebar) using static pull tests on many aspects, including supporting capacity, elongation, radial deformation, and energy absorption. The tests verified that the mechanical defects of the rebar, which include the decrease of bolt diameter, reduction of supporting capacity, and emergence and evolution of fracture until failure during the whole pull process, were caused by the Poisson's ratio effect. Due to the special structure set on the CRLD bolt, the bolt presents a seemingly unusual phenomenon of the negative Poisson's ratio effect, i.e., the diameter of the constant resistance structure increases while under-pulling. It is the very effect that ensures the extraordinary mechanical properties, including high resistance, large elongation, and strong energy absorption. According to the comparison and analysis of numerical simulation and field test, we can conclude that the CRLD bolt works better than the rebar bolt.展开更多
Full scale aircraft static test is a very important process of aircraft design, it is costly and time consuming. The testing accuracy and validity mainly depend on the rationality of the test scheme design. When the a...Full scale aircraft static test is a very important process of aircraft design, it is costly and time consuming. The testing accuracy and validity mainly depend on the rationality of the test scheme design. When the aircraft is being tested, the specimen's safety mainly depends on monitoring and understanding the testing data by way of evaluating the coherence with the digital simulation data synchyononsly. The test digital simulation can aid realizing above requirements and improving the test efficiency significantly during test scheme design stage or testing stage respectively. The key technologies and the solving methods of test digital simulation are presented and the application example is given.展开更多
Bi-directional static loading test adopting load cells is widely used around the world at present, with increase in diameter and length of deep foundations. In this paper, a new simple conversion method to predict the...Bi-directional static loading test adopting load cells is widely used around the world at present, with increase in diameter and length of deep foundations. In this paper, a new simple conversion method to predict the equivalent pile head load-settlement curve considering elastic shortening of deep foundation was put forward according to the load transfer mechanism. The proposed conversion method was applied to root caisson foundation in a bridge and to large diameter pipe piles in a sea wind power plant. Some new load cells, test procedure, and construction technology were adopted based on the applications to different deep foundations, which could enlarge the application scopes of bi-directional loading test. A new type of bi-directional loading test for pipe pile was conducted, in which the load cell was installed and loaded after the pipe pile with special connector has been set up. Unlike the conventional bi-directional loading test, the load cell can be reused and shows an evident economic benefit.展开更多
As a special geological phenomenon, the character of collapsible loess foundation is collapsible when penetrated by water. This character leads to the soil losing load bearing capacity largely and may lead to foundati...As a special geological phenomenon, the character of collapsible loess foundation is collapsible when penetrated by water. This character leads to the soil losing load bearing capacity largely and may lead to foundation failure. Pile is a popular foundation used in collapsible loess. The squeezed branch and plate pile is a new type of pile developed in recent years and has not be used in a project before. In this paper three squeezed branch and plate piles are tested in collapsible loess after immersion processing. The results may be used for reference in similar construction project, and to provide theoretical references for de- signing of the squeezed branch and plate piles in engineering practice.展开更多
A new structural damage identification method using limited test static displacement based on grey system theory is proposed in this paper. The grey relation coefficient of displacement curvature is defined and used t...A new structural damage identification method using limited test static displacement based on grey system theory is proposed in this paper. The grey relation coefficient of displacement curvature is defined and used to locate damage in the structure, and an iterative estimation scheme for solving nonlinear optimization programming problems based on the quadratic programming technique is used to identify the damage magnitude. A numerical example of a cantilever beam with single or multiple damages is used to examine the capability of the proposed grey-theory-based method to localize and identify damages. The factors of meas-urement noise and incomplete test data are also discussed. The numerical results showed that the damage in the structure can be localized correctly through using the grey-related coefficient of displacement curvature, and the damage magnitude can be iden-tified with a high degree of accuracy, regardless of the number of measured displacement nodes. This proposed method only requires limited static test data, which is easily available in practice, and has wide applications in structural damage detection.展开更多
In this article,dynamic method and static method of testing Poisson's ratio of OSB(Oriented Strand Board)were proposed.Through modal and static numerical analyses,the position where the transverse stress is equal ...In this article,dynamic method and static method of testing Poisson's ratio of OSB(Oriented Strand Board)were proposed.Through modal and static numerical analyses,the position where the transverse stress is equal to zero was determined.The binary linear regression method was applied to express the gluing position of the strain gauge as a relational express ion that depended on the length-width ratio and width-thickness ratio of the canti-lever plate.Then the longitudinal and transverse Poisson's ratios of OSB were mea sured by the given dynamic and static methods.In addition,the test results of OSB Poisson's ratio were analyzed with the probability distribution of random variables.The results showed that using the proposed dynamic method and static method,the test results for longitudinal and transverse Poisson's ratios of OSB were quite consistent,despite the gluing position of the strain gauges being different.And these OSB Poisson's ratios were accorded with that obtained by the axial tensile method and the four-point bending method.OSB longitudinal and transverse Poisson's ratios followed Weibull distribution.展开更多
To eliminate the node traction coupling during wind turbine blade full-scale static testing,a model free adaptive control algorithm is presented based on fuzzy control performance function compensation. Based on the u...To eliminate the node traction coupling during wind turbine blade full-scale static testing,a model free adaptive control algorithm is presented based on fuzzy control performance function compensation. Based on the universal model theory,the fuzzy model free adaptive control( FMFAC) algorithm is designed by configuring the spot static testing experiences as compensation function F( ·). Then the algorithm implementation process is provided and its quick convergence is proved. Using software to establish static load coupling model of multi-nodes,simulate and verify the validity of FMFAC algorithm,which is applied to wind turbines blade full-scale static testing. The results show that the adaptive decoupling ability of FMFAC is better. The traction of four load points can stay steady and change coordinately. Process error is not over ± 6 k N. The error rate is lower than 1% in special phase.This algorithm effectively eliminates the traction coupling of the static testing process,and makes wind turbine blade testing steadily.展开更多
The bamboo scrimber is an anisotropic material.The elastic constant values of the bamboo scrimber specimens measured by the dynamic and static methods are consistent,and the dynamic test method has the advantages of r...The bamboo scrimber is an anisotropic material.The elastic constant values of the bamboo scrimber specimens measured by the dynamic and static methods are consistent,and the dynamic test method has the advantages of rapidity,simplicity,good repeatability,and high precision.Bamboo scrimber has strong potential as a building material,and its elastic constant is an important index to measure its mechanical properties.To quickly,simply,non-destructively,and accurately detect the elastic constant of the bamboo scrimber,they were dynamically tested by the free plate transient excitation method and cantilever plate torsional vibration method.The static four-point bending method was used to verify the accuracy and reliability of the dynamic elastic modulus,shear modulus,and Poisson’s ratio of the bamboo scrimber.The mechanism analysis and evaluation of the quality grade,homogeneity,and size effect of the bamboo scrimber whole board were carried out.The main results show that the dynamic elastic modulus,shear modulus,and Poisson’s ratio of the bamboo scrimber are 12 GPa,1500 MPa,and 0.31,respectively,which meet the requirements of GB/T 40247-2021 for structural bamboo scrimber.展开更多
文摘This article uses real engineering projects as examples to analyze how static load test technology is applied in testing the bridge-bearing capacity.The analysis covers aspects such as testing section layout,test load and efficiency coefficient,loading plan,evaluation optimization,test result modification,and result evaluation.The aim is to support the accurate detection and evaluation of bridge-bearing capacity.
基金Natural Science Foundation of China under Grant Nos.51178342 and 51578314
文摘Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous components offer alternatives that may avoid such failures.A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics.Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used.However,a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported.In this study,a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing.Critical joints were designed and verified.Numerical models were established and calibrated to estimate frame shear forces.The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms.Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall.Drift distribution becomes more uniform with height.Concrete cracks and damage occurs in desired areas.The infilled rocking wall frame offers a promising approach to achieving seismic resilience.
文摘Highway bridges are an important part of the transportation industry and can promote social economic construction and development.In actual operation,highway bridges are often damaged due to overload and natural factors,which tend to affect the safety and shorten the service life of these bridges.Assessing the overall state and performance of highway bridges is therefore a key element.Static load test,which is a type of sustainable detection experiment,has many advantages,including low cost,high efficiency,and high accuracy.In this paper,the bridge structure is analyzed through the application of theoretical calculations and relevant comparisons,so as to judge the operating state of the bridge.
文摘The quality of the continuous rigid-frame railway bridge is related to the safety of train operation,so it is necessary to test its stiffness,strength,and other indicators.Static load test is a common technique for bridge inspection.This article summarizes the purpose of the static load test for a continuous rigid-frame railway bridge,including the required equipment,operation methods,etc.,and lists examples to analyze the operation process and precautions of static load test,hoping to provide reference information for relevant personnel.
基金supported by National Key Research and Development Program(2016YFC0600901)the National Natural Science Foundation of China(Grant Nos.51374214,51134005 and 51574248)+1 种基金the Special Fund of Basic Research and Operating of China University of Mining&Technology,Beijing(Grant Nos.2009QL03)the State Scholarship Fund of China
文摘A device for supporting soft rock masses combined with a constant resistance structure characterized by constant resistance and large deformation at the end of a steel bar, known as the constant resistance and large deformation(CRLD) bolt, has recently been developed to counteract soft rock swelling that often occurs during deep mining. In order to further study the mechanical properties of the CRLD bolt, we investigated its mechanical properties by comparison with the conventional strength bolt(rebar) using static pull tests on many aspects, including supporting capacity, elongation, radial deformation, and energy absorption. The tests verified that the mechanical defects of the rebar, which include the decrease of bolt diameter, reduction of supporting capacity, and emergence and evolution of fracture until failure during the whole pull process, were caused by the Poisson's ratio effect. Due to the special structure set on the CRLD bolt, the bolt presents a seemingly unusual phenomenon of the negative Poisson's ratio effect, i.e., the diameter of the constant resistance structure increases while under-pulling. It is the very effect that ensures the extraordinary mechanical properties, including high resistance, large elongation, and strong energy absorption. According to the comparison and analysis of numerical simulation and field test, we can conclude that the CRLD bolt works better than the rebar bolt.
文摘Full scale aircraft static test is a very important process of aircraft design, it is costly and time consuming. The testing accuracy and validity mainly depend on the rationality of the test scheme design. When the aircraft is being tested, the specimen's safety mainly depends on monitoring and understanding the testing data by way of evaluating the coherence with the digital simulation data synchyononsly. The test digital simulation can aid realizing above requirements and improving the test efficiency significantly during test scheme design stage or testing stage respectively. The key technologies and the solving methods of test digital simulation are presented and the application example is given.
基金Supported by the National Natural Science Foundation of China (50908048)the Priority Academic Program Development (PAPD) Project of JiangsuHigher Education Institutions
文摘Bi-directional static loading test adopting load cells is widely used around the world at present, with increase in diameter and length of deep foundations. In this paper, a new simple conversion method to predict the equivalent pile head load-settlement curve considering elastic shortening of deep foundation was put forward according to the load transfer mechanism. The proposed conversion method was applied to root caisson foundation in a bridge and to large diameter pipe piles in a sea wind power plant. Some new load cells, test procedure, and construction technology were adopted based on the applications to different deep foundations, which could enlarge the application scopes of bi-directional loading test. A new type of bi-directional loading test for pipe pile was conducted, in which the load cell was installed and loaded after the pipe pile with special connector has been set up. Unlike the conventional bi-directional loading test, the load cell can be reused and shows an evident economic benefit.
文摘As a special geological phenomenon, the character of collapsible loess foundation is collapsible when penetrated by water. This character leads to the soil losing load bearing capacity largely and may lead to foundation failure. Pile is a popular foundation used in collapsible loess. The squeezed branch and plate pile is a new type of pile developed in recent years and has not be used in a project before. In this paper three squeezed branch and plate piles are tested in collapsible loess after immersion processing. The results may be used for reference in similar construction project, and to provide theoretical references for de- signing of the squeezed branch and plate piles in engineering practice.
基金Project supported by the Natural Science Foundation of China(No. 50378041) and the Specialized Research Fund for the Doc-toral Program of Higher Education (No. 20030487016), China
文摘A new structural damage identification method using limited test static displacement based on grey system theory is proposed in this paper. The grey relation coefficient of displacement curvature is defined and used to locate damage in the structure, and an iterative estimation scheme for solving nonlinear optimization programming problems based on the quadratic programming technique is used to identify the damage magnitude. A numerical example of a cantilever beam with single or multiple damages is used to examine the capability of the proposed grey-theory-based method to localize and identify damages. The factors of meas-urement noise and incomplete test data are also discussed. The numerical results showed that the damage in the structure can be localized correctly through using the grey-related coefficient of displacement curvature, and the damage magnitude can be iden-tified with a high degree of accuracy, regardless of the number of measured displacement nodes. This proposed method only requires limited static test data, which is easily available in practice, and has wide applications in structural damage detection.
基金This research was sponsored by the Science and Technology Project for Policy Guidance of Jiangsu Province(SZ-LYG 2020016).
文摘In this article,dynamic method and static method of testing Poisson's ratio of OSB(Oriented Strand Board)were proposed.Through modal and static numerical analyses,the position where the transverse stress is equal to zero was determined.The binary linear regression method was applied to express the gluing position of the strain gauge as a relational express ion that depended on the length-width ratio and width-thickness ratio of the canti-lever plate.Then the longitudinal and transverse Poisson's ratios of OSB were mea sured by the given dynamic and static methods.In addition,the test results of OSB Poisson's ratio were analyzed with the probability distribution of random variables.The results showed that using the proposed dynamic method and static method,the test results for longitudinal and transverse Poisson's ratios of OSB were quite consistent,despite the gluing position of the strain gauges being different.And these OSB Poisson's ratios were accorded with that obtained by the axial tensile method and the four-point bending method.OSB longitudinal and transverse Poisson's ratios followed Weibull distribution.
基金National Natural Science Foundation of China(No.51567018)
文摘To eliminate the node traction coupling during wind turbine blade full-scale static testing,a model free adaptive control algorithm is presented based on fuzzy control performance function compensation. Based on the universal model theory,the fuzzy model free adaptive control( FMFAC) algorithm is designed by configuring the spot static testing experiences as compensation function F( ·). Then the algorithm implementation process is provided and its quick convergence is proved. Using software to establish static load coupling model of multi-nodes,simulate and verify the validity of FMFAC algorithm,which is applied to wind turbines blade full-scale static testing. The results show that the adaptive decoupling ability of FMFAC is better. The traction of four load points can stay steady and change coordinately. Process error is not over ± 6 k N. The error rate is lower than 1% in special phase.This algorithm effectively eliminates the traction coupling of the static testing process,and makes wind turbine blade testing steadily.
文摘The bamboo scrimber is an anisotropic material.The elastic constant values of the bamboo scrimber specimens measured by the dynamic and static methods are consistent,and the dynamic test method has the advantages of rapidity,simplicity,good repeatability,and high precision.Bamboo scrimber has strong potential as a building material,and its elastic constant is an important index to measure its mechanical properties.To quickly,simply,non-destructively,and accurately detect the elastic constant of the bamboo scrimber,they were dynamically tested by the free plate transient excitation method and cantilever plate torsional vibration method.The static four-point bending method was used to verify the accuracy and reliability of the dynamic elastic modulus,shear modulus,and Poisson’s ratio of the bamboo scrimber.The mechanism analysis and evaluation of the quality grade,homogeneity,and size effect of the bamboo scrimber whole board were carried out.The main results show that the dynamic elastic modulus,shear modulus,and Poisson’s ratio of the bamboo scrimber are 12 GPa,1500 MPa,and 0.31,respectively,which meet the requirements of GB/T 40247-2021 for structural bamboo scrimber.