期刊文献+
共找到2,722篇文章
< 1 2 137 >
每页显示 20 50 100
Common Artifacts and Remedies in Histological Preparations
1
作者 Marwa Jamal Hussain Al-Kinani 《Advances in Bioscience and Biotechnology》 CAS 2024年第3期174-183,共10页
The importance of the accuracy of preparing biological specimen as histological sections that can be examined under a microscope lies in reflecting a true image of the tissue that includes all its components, which ar... The importance of the accuracy of preparing biological specimen as histological sections that can be examined under a microscope lies in reflecting a true image of the tissue that includes all its components, which are used in scientific research or for the purpose of diagnosing various diseases of the body. Despite this, some cellular structures within the tissue may suffer from some alterations that result from the appearance of defects during any stage of preparing these microscopic sections, which alter or interfere with the precise cellular structures and morphology that constitute the tissue and thus give a different image for tissue features and cause confusion in the work histopathologist in the diagnosis. There are several reasons that can cause a misdiagnosis of the sample that occurs during the surgical separation process or after separation during the stages of microscopic preparation techniques from fixation stage, tissue processing, embedding or microtomy, staining until mounting procedures. The constant need to identify these defects and their causes in addition to try to reduce them is one of the biggest challenges evident in pathology laboratories. Therefore, this study aims to review the most common defects that occur in any stage of tissue processing, with an explanation of their causes and appropriate ways to avoid them. 展开更多
关键词 artifacts HISTOLOGICAL Preparations
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images
2
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Fetal MRI Artifacts: Semi-Supervised Generative Adversarial Neural Network for Motion Artifacts Reducing in Fetal Magnetic Resonance Images
3
作者 Ítalo Messias Félix Santos Gilson Antonio Giraldi +1 位作者 Heron Werner Junior Bruno Richard Schulze 《Journal of Computer and Communications》 2024年第6期210-225,共16页
This study addresses challenges in fetal magnetic resonance imaging (MRI) related to motion artifacts, maternal respiration, and hardware limitations. To enhance MRI quality, we employ deep learning techniques, specif... This study addresses challenges in fetal magnetic resonance imaging (MRI) related to motion artifacts, maternal respiration, and hardware limitations. To enhance MRI quality, we employ deep learning techniques, specifically utilizing Cycle GAN. Synthetic pairs of images, simulating artifacts in fetal MRI, are generated to train the model. Our primary contribution is the use of Cycle GAN for fetal MRI restoration, augmented by artificially corrupted data. We compare three approaches (supervised Cycle GAN, Pix2Pix, and Mobile Unet) for artifact removal. Experimental results demonstrate that the proposed supervised Cycle GAN effectively removes artifacts while preserving image details, as validated through Structural Similarity Index Measure (SSIM) and normalized Mean Absolute Error (MAE). The method proves comparable to alternatives but avoids the generation of spurious regions, which is crucial for medical accuracy. 展开更多
关键词 Fetal MRI artifacts Removal Deep Learning Image Processing Generative Adversarial Networks
下载PDF
Artifacts in two-dimensional shear wave elastography of liver
4
作者 Hui-Peng Wang Peng-Chao Zheng +1 位作者 Xue-Mei Wang Liang Sang 《World Journal of Gastroenterology》 SCIE CAS 2023年第21期3318-3327,共10页
BACKGROUND Artifacts are common when using two-dimensional shear wave elastography(2-D SWE)to measure liver stiffness(LS),but they are poorly recognized.AIM To investigate the presence and influence of artifacts in 2-... BACKGROUND Artifacts are common when using two-dimensional shear wave elastography(2-D SWE)to measure liver stiffness(LS),but they are poorly recognized.AIM To investigate the presence and influence of artifacts in 2-D SWE of liver.METHODS We included 158 patients with chronic liver disease,who underwent 2-D SWE examination by a novice and an expert.A cross line at the center of the elastogram was drawn and was divided it into four locations:top-left,top-right,bottom-left,and bottom-right.The occurrence frequency of artifacts in different locations was compared.The influence of artifacts on the LS measurements was evaluated by comparing the elastogram with the most artifacts(EMA)and the elastogram with the least artifacts(ELA).RESULTS The percentage of elastograms with artifacts in the novice(51.7%)was significantly higher than that of the expert(19.6%)(P<0.001).It was found that both operators had the highest frequency of artifacts at bottom-left,followed by top-left and bottom-right,and top-right had the lowest frequency.The LS values(LSVs)and standard deviation values of EMAs were significantly higher than those of ELAs for both operators.An intraclass correlation coefficient value of 0.96 was found in the LSVs of EMAs of the two operators,and it increased to 0.98 when the LSVs of the ELAs were used.Both operators had lower stability index values for EMAs than ELAs,but the difference was only statistically significant for the novice.CONCLUSION Artifacts are common when using 2-D SWE to measure LS,especially for the novice.Artifacts may lead to the overestimation of LS and reduce the repeatability and reliability of LS measurements. 展开更多
关键词 ULTRASOUND ELASTOGRAPHY artifact LIVER
下载PDF
Investigations of moiréartifacts induced by flux fluctuations in x-ray dark-field imaging
5
作者 王志立 陈子涵 +2 位作者 顾瑶 陈恒 葛昕 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期621-628,共8页
X-ray dark-field imaging using a grating interferometer has shown potential benefits for a variety of applications in recent years.X-ray dark-field image is commonly retrieved by using discrete Fourier transform from ... X-ray dark-field imaging using a grating interferometer has shown potential benefits for a variety of applications in recent years.X-ray dark-field image is commonly retrieved by using discrete Fourier transform from the acquired phasestepping data.The retrieval process assumes a constant phase step size and a constant flux for each stepped grating position.However,stepping errors and flux fluctuations inevitably occur due to external vibrations and/or thermal drift during data acquisition.Previous studies have shown that those influences introduce errors in the acquired phase-stepping data,which cause obvious moiréartifacts in the retrieved refraction image.This work investigates moiréartifacts in x-ray dark-field imaging as a result of flux fluctuations.For the retrieved mean intensity,amplitude,visibility and dark-field images,the dependence of moiréartifacts on flux fluctuation factors is theoretically derived respectively by using a first-order Taylor series expansion.Results of synchrotron radiation experiments verify the validity of the derived analytical formulas.The spatial frequency characteristics of moiréartifacts are analyzed and compared to those induced by phase-stepping errors.It illustrates that moiréartifacts can be estimated by a weighted mean of flux fluctuation factors,with the weighting factors dependent on the moiréphase and different greatly for each retrieved image.Furthermore,moiréartifacts can even be affected by object’s features not displayed in the particular contrast.These results can be used to interpret images correctly,identify sources of moiréartifacts,and develop dedicated algorithms to remove moiréartifacts in the retrieved multi-contrast images. 展开更多
关键词 x-ray imaging dark-field imaging moiréartifacts flux fluctuations
下载PDF
Method for predicting motion artifacts of plasma display panels
6
作者 张宇宁 Teunissen Kees +1 位作者 雷威 张晓兵 《Journal of Southeast University(English Edition)》 EI CAS 2007年第1期43-46,共4页
A simulation method is proposed to predict the motion artifacts of plasma display panels (PDPs). The method simulates the behavior of the human vision system when perceiving moving objects. The simulation is based o... A simulation method is proposed to predict the motion artifacts of plasma display panels (PDPs). The method simulates the behavior of the human vision system when perceiving moving objects. The simulation is based on the measured temporal light properties of the display for each gray level and each phosphor. Both the effect of subfield arrangement and phosphor decay are involved. A novel algorithm is proposed to improve the calculation speed. The simulation model manages to predict the appearance of the motion image perceived by a human with a still image. The results are validated by a set of perceptual evaluation experiments. This rapid and accurate prediction of motion artifacts enables objective characterization of the PDP performance in this aspect. 展开更多
关键词 plasma display panels motion artifacts dynamic false contour motion blur
下载PDF
An adaptive fuzzy filter for coding artifacts removal in video and image 被引量:2
7
作者 WU Jing YE Xiu-qing GU Wei-kang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第6期841-848,共8页
This paper proposes a new adaptive post-filtering algorithm to remove coding artifacts in block-based video coder. The proposed method concentrates on blocking and ringing artifacts removal. For de-blocking, the block... This paper proposes a new adaptive post-filtering algorithm to remove coding artifacts in block-based video coder. The proposed method concentrates on blocking and ringing artifacts removal. For de-blocking, the blocking strength is identified to determine the filtering range, and the maximum quantization parameter of the image is used to adapt the 1D fuzzy filter. For de-ringing, besides the edge detection, a complementary ringing detection method is proposed to locate the neglected ringing blocks, and the gradient threshold is adopted to adjust the parameter of 2D fuzzy filter. Experiments are performed on the MPEG-4 sequences. Compared with other methods, the proposed one achieves better detail preservation and artifacts removal performance with lower computational cost. 展开更多
关键词 Adaptive fuzzy filter Blocking artifacts Ringing artifacts De-blocking De-ringing
下载PDF
Enhanced segmentation of gastrointestinal polyps from capsule endoscopy images with artifacts using ensemble learning 被引量:3
8
作者 Jun-Xiao Zhou Zhan Yang +5 位作者 Ding-Hao Xi Shou-Jun Dai Zhi-Qiang Feng Jun-Yan Li Wei Xu Hong Wang 《World Journal of Gastroenterology》 SCIE CAS 2022年第41期5931-5943,共13页
BACKGROUND Endoscopy artifacts are widespread in real capsule endoscopy(CE)images but not in high-quality standard datasets.AIM To improve the segmentation performance of polyps from CE images with artifacts based on ... BACKGROUND Endoscopy artifacts are widespread in real capsule endoscopy(CE)images but not in high-quality standard datasets.AIM To improve the segmentation performance of polyps from CE images with artifacts based on ensemble learning.METHODS We collected 277 polyp images with CE artifacts from 5760 h of videos from 480 patients at Guangzhou First People’s Hospital from January 2016 to December 2019.Two public high-quality standard external datasets were retrieved and used for the comparison experiments.For each dataset,we randomly segmented the data into training,validation,and testing sets for model training,selection,and testing.We compared the performance of the base models and the ensemble model in segmenting polyps from images with artifacts.RESULTS The performance of the semantic segmentation model was affected by artifacts in the sample images,which also affected the results of polyp detection by CE using a single model.The evaluation based on real datasets with artifacts and standard datasets showed that the ensemble model of all state-of-the-art models performed better than the best corresponding base learner on the real dataset with artifacts.Compared with the corresponding optimal base learners,the intersection over union(IoU)and dice of the ensemble learning model increased to different degrees,ranging from 0.08%to 7.01%and 0.61%to 4.93%,respectively.Moreover,in the standard datasets without artifacts,most of the ensemble models were slightly better than the base learner,as demonstrated by the IoU and dice increases ranging from-0.28%to 1.20%and-0.61%to 0.76%,respectively.CONCLUSION Ensemble learning can improve the segmentation accuracy of polyps from CE images with artifacts.Our results demonstrated an improvement in the detection rate of polyps with interference from artifacts. 展开更多
关键词 artifacts Capsule endoscopy POLYPS Ensemble learning SEGMENTATION ROBUSTNESS
下载PDF
Reduction of artifacts in dental cone beam CT images to improve the three dimensional image reconstruction 被引量:2
9
作者 Issa Ibraheem 《Journal of Biomedical Science and Engineering》 2012年第8期409-415,共7页
Cone-beam CT (CBCT) scanners are based on volumetric tomography, using a 2D extended digital array providing an area detector [1,2]. Compared to traditional CT, CBCT has many advantages, such as less X-ray beam limita... Cone-beam CT (CBCT) scanners are based on volumetric tomography, using a 2D extended digital array providing an area detector [1,2]. Compared to traditional CT, CBCT has many advantages, such as less X-ray beam limitation, and rapid scan time, etc. However, in CBCT images the x-ray beam has lower mean kilovolt (peak) energy, so the metal artifact is more pronounced on. The position of the shadowed region in other views can be tracked by projecting the 3D coordinates of the object. Automatic image segmentation was used to replace the pixels inside the metal object with the boundary pixels. The modified projection data, using synthetically Radon Transformation, were then used to reconstruct a new back projected CBCT image. In this paper, we present a method, based on the morphological, area and pixel operators, which we applied on the Radon transformed image, to reduce the metal artifacts in CBCT, then we built the Radon back project images using the radon invers transformation. The artifacts effects on the 3d-reconstruction is that, the soft tissues appears as bones or teeth. For the preprocessing of the CBCT images, two methods are used to recognize the noisy black areas that the first depends on thresholding and closing algorithm, and the second depends on tracing boundaries after using thresholding algorithm too. The intensity of these areas is the lowest in the image than other tissues, so we profit this property to detect the edges of these areas. These two methods are applied on phantom and patient image data. It deals with reconstructed CBCT dicom images and can effectively reduce such metal artifacts. Due to the data of the constructed images are corrupted by these metal artifacts, qualitative and quantitative analysis of CBCT images is very essential. 展开更多
关键词 CBCT artifact Medical IMAGE Processing CT IMAGE Reconstruction
下载PDF
Determining the Authenticity of Artifacts by Oxygen Isotope Analysis 被引量:1
10
作者 Joel Kronfeld Amnon Rosenfeld Howard R. Feldman 《Open Journal of Geology》 2013年第4期313-321,共9页
A technique used to determine the authenticity of artifacts that compares the oxygen isotopic composition of speleothems to the carbonate included within the patina of unprovenanced artifacts is of questionable value.... A technique used to determine the authenticity of artifacts that compares the oxygen isotopic composition of speleothems to the carbonate included within the patina of unprovenanced artifacts is of questionable value. The unprovenanced Jehoash Inscription Tablet and James Ossuary are of potentially immense historical and cultural importance. Nevertheless, they both were rejected by workers based on the oxygen isotope technique which provided the major foundational evidence of forgery in the longest running archaeological trial in Israel. Nevertheless, both these artifacts were determined not to be forged. The initial incongruence between the oxygen isotopes of the speleothems of the Soreq cave (Israel) purported to represent the unique composition of Jerusalem rainfall, and the patina on the artifacts, can be readily explained by the accretion of materials and geo-biochemical processes expected in normal patina formation in the Jerusalem region. The patina formation involves sporadic events in disequilibrium kinetic processes that are opposed to the equilibrium formation of speleothems in a sealed cave. Moreover, 23 of 56 patina samples (41%) on well-documented ancient artifacts from Israel yielded oxygen isotope values greater or lower than the expected speleothem values of -4 δ18O ‰ [PDB] to -6 δ18O ‰ [PDB]. Thus, the speleothem-patina correlation is invalid and the applied oxygen isotopes technique for determining the authenticity of patinas on artifacts is not a useful tool in the authentication of artifacts. 展开更多
关键词 Oxygen Isotope PATINA artifact ARCHAEOLOGY SPELEOTHEM
下载PDF
A review of methods for mitigating ionospheric artifacts in differential SAR interferometry 被引量:2
11
作者 Bochen Zhang Wu Zhu +3 位作者 Xiaoli Ding Chisheng Wang Songbo Wu Qin Zhang 《Geodesy and Geodynamics》 CSCD 2022年第2期160-169,共10页
Interferometric synthetic aperture radar(InSAR)has been widely used to measure ground displacements related to geophysical and anthropic activities over the past three decades.Satellite SAR systems use microwave signa... Interferometric synthetic aperture radar(InSAR)has been widely used to measure ground displacements related to geophysical and anthropic activities over the past three decades.Satellite SAR systems use microwave signals that interact with the ionosphere when they travel through it during the imaging processes.In this context,ionospheric variations can significantly contaminate SAR imagery,which in turn affects spaceborne InSAR measurements.This bias also leads to a decrease in the coherence and accuracy of InSAR measurements,especially for the low-frequency SAR systems.In this paper,we give an overview of the latest methods for mitigating the ionospheric contributions in InSAR,including Faraday rotation method,azimuth shift method,and range split-spectrum method,and only focus on the single pair of InSAR interferograms.The current challenges and future perspectives are outlined at the end of this paper. 展开更多
关键词 InSAR Ionospheric artifacts Azimuth pixel shift Faraday rotation Range split-spectrum
下载PDF
Ring artifacts removal in X-ray-induced acoustic computed tomography 被引量:1
12
作者 Prabodh Kumar Pandey Hari Om Aggrawal +3 位作者 Siqi Wang Kaitlyn Kim An Liu Liangzhong Xiang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第3期54-69,共16页
X-ray-induced acoustic computed tomography(XACT)is a hybrid imaging modality for detecting X-ray absorption distribution via ultrasound emission.It facilitates imaging from a single projection X-ray illumination,thus ... X-ray-induced acoustic computed tomography(XACT)is a hybrid imaging modality for detecting X-ray absorption distribution via ultrasound emission.It facilitates imaging from a single projection X-ray illumination,thus reducing the radiation exposure and improving imaging speed.Nonuniform detector response caused by the interference between multichannel data acquisition for ring array transducers and amplifier systems yields ring artifacts in the reconstructed XACT images,which compromises the image quality.We propose model-based algorithms for ring artifacts corrected XACT imaging and demonstrate their effcacy on numerical and experimental measurements.The corrected reconstructions indicate significantly reduced ring artifacts as compared to their conventional counterparts. 展开更多
关键词 X-ray-induced acoustic computed tomography(XACT) ring artifacts artifacts correction
下载PDF
Investigation of artifacts by mapping SAR in thermoacoustic imaging 被引量:1
13
作者 Xiao Liang Qiang Liu +3 位作者 Zezhou Sun Weizhi Qi Yubin Gong Lei Xi 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第5期75-84,共10页
Microwave-induced thermoacoustic imaging(MI-TAI)remains one of the focus of attention among biomedical imaging modalities over the last decade.However,the transmission and dis-tribution of microwave inside bio-tissues... Microwave-induced thermoacoustic imaging(MI-TAI)remains one of the focus of attention among biomedical imaging modalities over the last decade.However,the transmission and dis-tribution of microwave inside bio-tissues are complicated,thus result in severe artifacts.In this study,to reveal the underlying mechanisms of artifacts,we deeply investigate the distribution of specific absorption rate(SAR)inside tissue-mimicking phantoms with varied morphological features using both mathematical simulations and corresponding experiments.Our simulated results,which are confirmed by the associated experimental results,show that the SAR distri-bution highly depends on the geometries of the imaging targets and the polarizing features of the microwave.In addition,we propose the potential mechanisms including Mie-scattering,Fabry-Perot-feature,small curvature effect to interpret the diffraction effect in different scenarios,which may provide basic guidance to predict and distinguish the artifacts for TAI in both fundamental and clinical studies. 展开更多
关键词 IMAGING MICROWAVE thermoacoustic imaging artifacts specific absorption rate
下载PDF
Removal of Ocular Artifacts from Electroencephalo-Graph by Improving Variational Mode Decomposition 被引量:1
14
作者 Miao Shi Chao Wang +3 位作者 Wei Zhao Xinshi Zhang Ye Ye Nenggang Xie 《China Communications》 SCIE CSCD 2022年第2期47-61,共15页
Ocular artifacts in Electroencephalography(EEG)recordings lead to inaccurate results in signal analysis and process.Variational Mode Decomposition(VMD)is an adaptive and completely nonrecursive signal processing metho... Ocular artifacts in Electroencephalography(EEG)recordings lead to inaccurate results in signal analysis and process.Variational Mode Decomposition(VMD)is an adaptive and completely nonrecursive signal processing method.There are two parameters in VMD that have a great influence on the result of signal decomposition.Thus,this paper studies a signal decomposition by improving VMD based on squirrel search algorithm(SSA).It’s improved with abilities of global optimal guidance and opposition based learning.The original seasonal monitoring condition in SSA is modified.The feedback of whether the optimal solution is successfully updated is used to establish new seasonal monitoring conditions.Opposition-based learning is introduced to reposition the position of the population in this stage.It is applied to optimize the important parameters of VMD.GOSSA-VMD model is established to remove ocular artifacts from EEG recording.We have verified the effectiveness of our proposal in a public dataset compared with other methods.The proposed method improves the SNR of the dataset from-2.03 to 2.30. 展开更多
关键词 ocular artifact variational mode decomposition squirrel search algorithm global guidance ability opposition-based learning
下载PDF
Artifacts Reduction Using Multi-Scale Feature Attention Network in Compressed Medical Images 被引量:1
15
作者 Seonjae Kim Dongsan Jun 《Computers, Materials & Continua》 SCIE EI 2022年第2期3267-3279,共13页
Medical image compression is one of the essential technologies to facilitate real-time medical data transmission in remote healthcare applications.In general,image compression can introduce undesired coding artifacts,... Medical image compression is one of the essential technologies to facilitate real-time medical data transmission in remote healthcare applications.In general,image compression can introduce undesired coding artifacts,such as blocking artifacts and ringing effects.In this paper,we proposed a Multi-Scale Feature Attention Network(MSFAN)with two essential parts,which are multi-scale feature extraction layers and feature attention layers to efficiently remove coding artifacts of compressed medical images.Multiscale feature extraction layers have four Feature Extraction(FE)blocks.Each FE block consists of five convolution layers and one CA block for weighted skip connection.In order to optimize the proposed network architectures,a variety of verification tests were conducted using validation dataset.We used Computer Vision Center-Clinic Database(CVC-ClinicDB)consisting of 612 colonoscopy medical images to evaluate the enhancement of image restoration.The proposedMSFAN can achieve improved PSNR gains as high as 0.25 and 0.24 dB on average compared to DnCNNand DCSC,respectively. 展开更多
关键词 Medical image processing convolutional neural network deep learning TELEMEDICINE artifact reduction image restoration
下载PDF
Sing Your City: Local Stories of Global Artifacts 被引量:1
16
作者 Alexander Rosenblatt 《Sociology Study》 2019年第3期116-127,共12页
The article discusses five local stories that, without being connected to each other, tell about the socio-cultural circumstances accompanying creation of works of art that have received significant (but not the highe... The article discusses five local stories that, without being connected to each other, tell about the socio-cultural circumstances accompanying creation of works of art that have received significant (but not the highest) recognition on a global scale. The discussion concerns three songs about cities: Torna a Surriento, Moscow Nights, and Li Beirut;a famous Soviet painting Low Marks Again;and the design features of Audi cars for the US market over the past decade. The approach to each certain artifact, be it song, painting, or the design of rear turn signals, is developed on the basis of disciplinary affiliation, whereas a discipline is more sociology, anthropology, or history of an appropriate art, than its theory. Another research method places a local context into the test tube of globalization. Experience shows that these two methods are applicable to different arts, places, and periods enriching the scientist with more detailed information about the era studied. 展开更多
关键词 GLOBAL artifact second ECHELON SONGS about cities dog in a painting rear turn signals
下载PDF
Score based assessment of implant-related post fusion MRI artifacts focused on different interbody disc spacers: An <i>in vitro</i>study
17
作者 Thorsten Ernstberger Gabert Heidrich +1 位作者 Hans-Michael Klinger Mike Herbert Baums 《Open Journal of Clinical Diagnostics》 2012年第2期23-29,共7页
Interbody disc spacers for anterior spine fusion are made of different materials, such as titanium alloys or carbon fiber reinforced polymers (CFRP). Implant-related susceptibility artifacts can decrease the quality o... Interbody disc spacers for anterior spine fusion are made of different materials, such as titanium alloys or carbon fiber reinforced polymers (CFRP). Implant-related susceptibility artifacts can decrease the quality of MRI scans. This cadaveric study aimed to demonstrate the extent that implant-related MRI artifacting affects the post fusion differentiation of the spinal canal (SC) and intervertebral disc space (IDS). In 6 cadaveric porcine spines, we evaluated the post-im- plantation MRI scans of a titanium and CFRP spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into regions of interest (ROI) to characterize the SC and IDS. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists artifact-affected image quality of the median MRI slice was rated on a modified score of 0-1-2-3. A maximum score of 15 points for the SC and 9 points for the IDS (100%) was possible. Turbo spin echo sequences produced the best scores for both spacers and the control. Only the control achieved a score of 100%. For the IDS the titanium and CFRP spacer maximally scored 0% and 74%, for the SC 80% and 99%, respectively. By using favored T1 TSE sequences the CFRP-spacer represented clear advantages in post fusion spinal imaging. Independent of artifact dimensions the used scoring system allowed us to create an implant-related ranking of MRI scan quality in reference to the bone control. 展开更多
关键词 INTERBODY Disc Spacer POST FUSION MRI Imaging artifacts artifact SCORE
下载PDF
Influences of Motion Artifacts on Three-Dimensional Reconstruction Volume and Conformal Radiotherapy Planning 被引量:9
18
作者 ZHANG Shu-xu CHEN Guang-jie +2 位作者 ZHOU Ling-hong YANG Ke-cheng LIN Sheng-qu 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第3期123-130,共8页
Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor al... Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor along the cranial-caudal direction is constructed by step motor, small ball of polyethylene and potato. Ten different scan protocols were set and CT data of the phantom were acquired by using a commercial GE LightSpeedl6 CT scanner. The 3D reconstruction of the CT data was implemented by adopting volume-rendering technology of GE AdvantageSim 6.0 system. The reconstructed volumes of each target in different scan protocols were measured through 3D measuring tools. Thus, relative deviations of the reconstruction volumes between moving targets and static ones were determined. The three-dimensional conformal radiation therapy (3D- CRT) plans and conformal fields were created and compared for a static/moving target with the WiMRT treatment planning system (TPS). Results:For a static target, there was no obvious difference among the 3D reconstruction volumes when the CT data were acquired with different pitches and slices. The appearance of 3D reconstruction volume and 3D conformal field of a moving target was quite different from that of static one. The maximum relative deviation is nearly 90% for a moving target scanned with different scan protocols. The relative deviations are variable among the different targets, about from -39.8% to 89.5% for a smaller target and from - 18.4% to 20.5% for a larger one. Conclusion :The motion artifacts have great effects on 3 D-CRT planning and reconstruction volume, which will greatly induce distorted conformal radiation fields and false DVHs for a moving target. 展开更多
关键词 motion artifact PHANTOM three-dimensional conformal radiation therapy 3 D-CRT) four-dimensional computed tomography 4 D-CT)
下载PDF
The design of traditional artifacts culture and geographical features 被引量:1
19
作者 LIU Gang ZHAO De-cheng 《通讯和计算机(中英文版)》 2009年第8期70-75,80,共7页
关键词 设计特点 文化地理 传统文化 文物 地理条件 中国国情 设计方法 和谐发展
下载PDF
Imaging characteristics of metallic interbody spacers: in vitro score evaluation of susceptibility artifacts considering different MRI sequences
20
作者 T. Ernstberger G. Heidrich G. Buchhorn 《Journal of Biomedical Science and Engineering》 2010年第2期181-186,共6页
Aim: Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium, carbon or cobalt-chrome, which can affect the post- fusion MRI scans. Implant-related susceptibility artifacts c... Aim: Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium, carbon or cobalt-chrome, which can affect the post- fusion MRI scans. Implant-related susceptibility artifacts can decrease the quality of MRI scans, thwar- ting proper evaluation. This cadaver study aimed to demonstrate the extent that implant-related MRI artifacting affects the post-fusion evaluation of intervertebral spacers. Methods: In a cadaveric porcine spine, we evaluated the post-implantation MRI scans of 2 metallic intervertebral spacers (TiAL6V4, CoCrMo) that differed in shape, material, surface qualities and implantation technique. A spacer made of human cortical bone was used as a control. The median sagittal MRI slice was divided into 12 regions of interest (ROI). Results: No significant differences were found on 15 different MRI sequences read independently by an interobserver-validated team of specialists (P>0.05). Artifact-affected image quality was rated on a score of 0-1-2. A maximum score of 24 points (100%) was possible. Turbo spin echo sequences produced the best scores for all spacers and the control. Only the control achieved a score of 100%. The titanium and cobalt-chrome spacers scored 62.5% and 50%, respectively. Conclusions: Our scoring system allowed us to create an implant-related rank- ing of MRI scan quality in reference to the control that was independent of artifact dimensions. Even with turbo spin echo sequences, the susceptibility artifacts produced by the metallic spacers showed a high degree of variability. Despite optimum sequen- cing, implant design and material are relevant factors in MRI artifacting. 展开更多
关键词 INTERVERTEBRAL SPACERS METALLIC Implant Materials MRI Susceptibility artifacts
下载PDF
上一页 1 2 137 下一页 到第
使用帮助 返回顶部