Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infec...Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infection but also because of its vertical transmission rate and the potential severe adverse complications/morbidity that can result from its transmission to the fetus. Although the incidence of maternal syphilis and its fetal sequalae in low-income countries has been considerable for several years, the disease has been almost non-existent in high income countries with wide antenatal screening coverage and effective treatment programmes for Syphilis. The recent alarming increase in the incidence of maternal syphilis in high income countries has spawned a renewed public health interest in the infection, with several countries updating and strengthening public health guidance in an attempt to stem this dramatic trend. This is a short clinical update for the practising obstetrician on how to manage the antenatal patient with a positive syphilis screening test.展开更多
Fatigue is a common sense caused by crushing labor, stressful social events and various illnesses. It is usually judged by their subjective symptoms, but it should be evaluated in an objective perspective. Here we sho...Fatigue is a common sense caused by crushing labor, stressful social events and various illnesses. It is usually judged by their subjective symptoms, but it should be evaluated in an objective perspective. Here we show that the decrease of working efficiency and sympathetic hyperactivity are associated with mental fatigue state caused by prolonged mental workload. Recently we made a new mental fatigue model of healthy volunteers caused by long-term computerized Kraepelin test (CKT) workload. CKT is our new software for automatically checking the calculation capability, with which it is easy to determine the reaction time (RT), coefficient of variance of reaction time (CV), and accuracy of the answers (AC) during tasks. We put 24 healthy volunteers into the fatigue state by subjecting them to 120 minutes’ CKT workload, and then studied the changes in fatigue sensation, RT, CV, and AC before and after the CKT workload. The fatigue sensation, RT, and CV were clearly increased by the fatigue-inducing task and recovered during the resting period. We also studied the changes in autonomic nerve activity by using heart rate variability analysis. The low/high frequency component ratio (LF/HF) was signifi-cantly increased by the fatigue-inducing task and decreased by resting, suggesting that mental stress causes a relatively sympathetic nerve activity-dominant state. Therefore, our new fatigue model involving a long-term CKT workload is a good mental fatigue model to provide much information about the fatigue state simultane-ously, and the increase of RT, CV, and proportion of sympathetic activity (LF/HF) are associated with mental fatigue state. These might be useful objective biomarkers or evaluating a mental fatigue state.展开更多
The results of visual event-related potential(ERP)examinations and reactiontime(RT)tests were reported in 30 elders and compared with their performanceintellegence quotient(PIQ)scores.The subjects consisted of 18 male...The results of visual event-related potential(ERP)examinations and reactiontime(RT)tests were reported in 30 elders and compared with their performanceintellegence quotient(PIQ)scores.The subjects consisted of 18 males and 12 femalesaged 50-71(mean 61.4)years old.No history of central nervous system disease wasfound.The visual stimuli were randomly presented to the subject,including three sym-bols:E as target stimulus with 0.15 probability,and H and E as nontarget stimuliwith 0.15 and 0.70 probability respectively.The recording electrodes were placed on Fzand Pz.The duration from the subject seeing the target to touching a button immediatelywas considered as reaction time(RT).It was shown that the P3 latency at Pz was longer than that at Fz and the P3amplitude at Pz was larger than that at Fz,and that the RT was longer than P3 latencywith obvious effect of distribution(P【0.05 at Fz and P】0.05 at Pz)as well .The higherthe PIQ scores,the longer the RT and the P3 latency.It is suggested that the ERPmight reflect the differences of PIQ scores,and the P3 is an objective index.We considerthat the research of ERP is of great interest in the neuropsychological and neurological sci-ences.展开更多
A highly accurate and precise technique for measurement of the 93 Nb(n,n’)93m Nb reaction rate was established for the material surveillance tests,etc.in fast reactors.The self-absorption effect on the measurement of...A highly accurate and precise technique for measurement of the 93 Nb(n,n’)93m Nb reaction rate was established for the material surveillance tests,etc.in fast reactors.The self-absorption effect on the measurement of the characteristic X-rays emitted by 93m Nb was decreased by the dissolution and evaporation to dryness of niobium dosimeter.A highly precise count of the number of 93 Nb atoms was obtained by measuring the niobium solution concentration using inductively coupled plasma mass spectrometry.X-rays of 93m Nb were measured accurately by means of comparing the X-ray intensity of irradiated niobium solution with that of the solution in which stable 93 Nb was added.The difference between both intensities indicates the effect of 182 Ta,which is generated from an impurity tantalum,and the intensity of X-rays from 93m Nb was evaluated.Measurement error of the 93 Nb(n,n’)93m Nb reaction rate was reduced to be less than 4%,which was equivalent to the other reaction rate errors of dosimeters used for Joyo dosimetry.In addition,an advanced technique using Resonance Ionization Mass Spectrometry was proposed for the precise measurement of 93m Nb yield,and 93m Nb will be resonance-ionized selectively by discriminating the hyperfine splitting of the atomic energy levels between 93 Nb and 93m Nb at high resolution.展开更多
Mg alloys have mechanical properties compatible with human bones.However,their rapid degradation and associated foreign body reactions in vivo significantly limit their application for human implants.In this study,thr...Mg alloys have mechanical properties compatible with human bones.However,their rapid degradation and associated foreign body reactions in vivo significantly limit their application for human implants.In this study,three differently processed Mg alloys,pure Mg(PM),cold extruded Mg alloy AZ31(CE AZ31),and fully annealed AZ31 Mg alloy(FA AZ31)were comparatively investigated for their potential as implants using a rat model.All three implanted Mg alloys do not show any impact on hepato-and renal function,nor any signs of observable changes to vital organs.Proteomics analysis of tissues directly contacting the implants 2.5 months post implantation revealed that FA AZ31 activates very few inflammation and immune associated signaling pathways;while the CE AZ31 and PM produce more significant inflammatory responses as confirmed by cytokine array analyses.Further,FA AZ31 activated pathways for cell organization and development that may improve the recovery of injured tissues.Structurally,EBSD analysis reveals that the FA AZ31 alloy has a higher ratio of first-order pyramidal orientated(10–11){10–1–2}grain texture with a value of 0.25,while PM and CE AZ31 alloys have lower ratios of first-order pyramidal orientated texture with the values of 0.16 and 0.17,respectively.This is associated with recovery and recrystallisation during annealing which promotes grain texture which exhibits enhanced degradation behaviours and induces a more limited immune response in vivo.In conclusion,the FA AZ31 demonstrated better biocompatibility and corrosion resistance and is a promising candidate for metal-based degradable implants which warrants further investigation.展开更多
文摘Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infection but also because of its vertical transmission rate and the potential severe adverse complications/morbidity that can result from its transmission to the fetus. Although the incidence of maternal syphilis and its fetal sequalae in low-income countries has been considerable for several years, the disease has been almost non-existent in high income countries with wide antenatal screening coverage and effective treatment programmes for Syphilis. The recent alarming increase in the incidence of maternal syphilis in high income countries has spawned a renewed public health interest in the infection, with several countries updating and strengthening public health guidance in an attempt to stem this dramatic trend. This is a short clinical update for the practising obstetrician on how to manage the antenatal patient with a positive syphilis screening test.
文摘Fatigue is a common sense caused by crushing labor, stressful social events and various illnesses. It is usually judged by their subjective symptoms, but it should be evaluated in an objective perspective. Here we show that the decrease of working efficiency and sympathetic hyperactivity are associated with mental fatigue state caused by prolonged mental workload. Recently we made a new mental fatigue model of healthy volunteers caused by long-term computerized Kraepelin test (CKT) workload. CKT is our new software for automatically checking the calculation capability, with which it is easy to determine the reaction time (RT), coefficient of variance of reaction time (CV), and accuracy of the answers (AC) during tasks. We put 24 healthy volunteers into the fatigue state by subjecting them to 120 minutes’ CKT workload, and then studied the changes in fatigue sensation, RT, CV, and AC before and after the CKT workload. The fatigue sensation, RT, and CV were clearly increased by the fatigue-inducing task and recovered during the resting period. We also studied the changes in autonomic nerve activity by using heart rate variability analysis. The low/high frequency component ratio (LF/HF) was signifi-cantly increased by the fatigue-inducing task and decreased by resting, suggesting that mental stress causes a relatively sympathetic nerve activity-dominant state. Therefore, our new fatigue model involving a long-term CKT workload is a good mental fatigue model to provide much information about the fatigue state simultane-ously, and the increase of RT, CV, and proportion of sympathetic activity (LF/HF) are associated with mental fatigue state. These might be useful objective biomarkers or evaluating a mental fatigue state.
文摘The results of visual event-related potential(ERP)examinations and reactiontime(RT)tests were reported in 30 elders and compared with their performanceintellegence quotient(PIQ)scores.The subjects consisted of 18 males and 12 femalesaged 50-71(mean 61.4)years old.No history of central nervous system disease wasfound.The visual stimuli were randomly presented to the subject,including three sym-bols:E as target stimulus with 0.15 probability,and H and E as nontarget stimuliwith 0.15 and 0.70 probability respectively.The recording electrodes were placed on Fzand Pz.The duration from the subject seeing the target to touching a button immediatelywas considered as reaction time(RT).It was shown that the P3 latency at Pz was longer than that at Fz and the P3amplitude at Pz was larger than that at Fz,and that the RT was longer than P3 latencywith obvious effect of distribution(P【0.05 at Fz and P】0.05 at Pz)as well .The higherthe PIQ scores,the longer the RT and the P3 latency.It is suggested that the ERPmight reflect the differences of PIQ scores,and the P3 is an objective index.We considerthat the research of ERP is of great interest in the neuropsychological and neurological sci-ences.
文摘A highly accurate and precise technique for measurement of the 93 Nb(n,n’)93m Nb reaction rate was established for the material surveillance tests,etc.in fast reactors.The self-absorption effect on the measurement of the characteristic X-rays emitted by 93m Nb was decreased by the dissolution and evaporation to dryness of niobium dosimeter.A highly precise count of the number of 93 Nb atoms was obtained by measuring the niobium solution concentration using inductively coupled plasma mass spectrometry.X-rays of 93m Nb were measured accurately by means of comparing the X-ray intensity of irradiated niobium solution with that of the solution in which stable 93 Nb was added.The difference between both intensities indicates the effect of 182 Ta,which is generated from an impurity tantalum,and the intensity of X-rays from 93m Nb was evaluated.Measurement error of the 93 Nb(n,n’)93m Nb reaction rate was reduced to be less than 4%,which was equivalent to the other reaction rate errors of dosimeters used for Joyo dosimetry.In addition,an advanced technique using Resonance Ionization Mass Spectrometry was proposed for the precise measurement of 93m Nb yield,and 93m Nb will be resonance-ionized selectively by discriminating the hyperfine splitting of the atomic energy levels between 93 Nb and 93m Nb at high resolution.
基金supported in part by JSPS research grant(No.P16718)Natural Science Foundation of Guangdong Province(No.2020A1515010855)+2 种基金National Science Foundation of China(31971355)Genecology MCR Seed Funding of University of the Sunshine CoastDeng Feng Project of Foshan First People’s Hospital(2019A008)。
文摘Mg alloys have mechanical properties compatible with human bones.However,their rapid degradation and associated foreign body reactions in vivo significantly limit their application for human implants.In this study,three differently processed Mg alloys,pure Mg(PM),cold extruded Mg alloy AZ31(CE AZ31),and fully annealed AZ31 Mg alloy(FA AZ31)were comparatively investigated for their potential as implants using a rat model.All three implanted Mg alloys do not show any impact on hepato-and renal function,nor any signs of observable changes to vital organs.Proteomics analysis of tissues directly contacting the implants 2.5 months post implantation revealed that FA AZ31 activates very few inflammation and immune associated signaling pathways;while the CE AZ31 and PM produce more significant inflammatory responses as confirmed by cytokine array analyses.Further,FA AZ31 activated pathways for cell organization and development that may improve the recovery of injured tissues.Structurally,EBSD analysis reveals that the FA AZ31 alloy has a higher ratio of first-order pyramidal orientated(10–11){10–1–2}grain texture with a value of 0.25,while PM and CE AZ31 alloys have lower ratios of first-order pyramidal orientated texture with the values of 0.16 and 0.17,respectively.This is associated with recovery and recrystallisation during annealing which promotes grain texture which exhibits enhanced degradation behaviours and induces a more limited immune response in vivo.In conclusion,the FA AZ31 demonstrated better biocompatibility and corrosion resistance and is a promising candidate for metal-based degradable implants which warrants further investigation.