Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s...Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.展开更多
In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office...In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office automation, in-vehicle data communication etc. In this paper we present an architecture for the physical layer of a PLC transceiver based on Orthogonal Frequency Division Multiplexing (OFDM) and the impact on multipath distortion for PLC transmission in terms of bit error rate. Since there is no standard PLC channel model available, a widely accepted multipath channel model is used for simulation purpose. Simulation results as well as FPGA synthesis verify the effectiveness of the proposed architecture for PLC modem design at 110 Mbps data rate.展开更多
This letter derives the Equivalent M-band Discrete Wavelet(EMDW) transmission mode of Orthogonal Frequency Division Multiplexing(OFDM) transmission systems, and presents a new Quadrature M-band Discrete Wavelet(QMDW) ...This letter derives the Equivalent M-band Discrete Wavelet(EMDW) transmission mode of Orthogonal Frequency Division Multiplexing(OFDM) transmission systems, and presents a new Quadrature M-band Discrete Wavelet(QMDW) based OFDM-CDMA(Code Division Multiple Access) communication systems for high speed Power Line Communication (PLC) channels.This system gives much better robustness to Inter-Channel Interference (ICI), Multi-User Interference (MUI) and noise interference, which is verified by simulation.展开更多
Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queu...Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queueing theoretic framework. The proposed PLC network model consists of a base station (BS), which is located at a transformer station and connected to the backbone communication networks, and a number of subscriber stations that are interconnected with each other and with the BS via the power line transmission medium. An orthogonal frequency division multiplexing based technique is assumed for forming the transmission channels in a frequency spectrum. The channels are subject to failure during service due to noise. We determine the steady-state solution of the proposed model and derive a set of performance metrics of interest. Numerical and simulation results are presented to provide further insights into the analytical results. The proposed modeling method is expected to be used for evaluation and design of future PLC networks.展开更多
Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and redu...Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and reducing the cost.But it suffers from the impulsive noise because it introduces significant time variance into the power line channel.In this paper,a polar codes based orthogonal frequency division multiplexing(OFDM)PLC system is proposed to deal with the impulsive noise and thereby improve the transmission performance.Firstly,the impulsive noise is modelled with a multi-damped sine function by analyzing the time behavior of impulse events.Then the polar codes are used to combat the impulsive noise of PLC channel,and a low complexity bit-flipping decoding method based on CRC-aided successive cancellation list(CA-SCL)decoding algorithm is proposed.Simulations evaluate the proposed decoding algorithm and the results validate the suggested polar codes based OFDM-PLC scheme which can improve the BER performance of PLC with impulsive interference.展开更多
Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the intere...Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the interest of both utilities and residents. They help to achieve load balance and increase the grid reliability by encouraging residents to reduce their power usage during peak load periods in return for incentives. To automate this process, appliances, in-house sensors, and the AMI controller need to be networked together. In this paper, we compare mainstream network technologies applicable to home appliance control and propose a solution combining Power Line Communication (PLC) with wireless communication in smart homes for the purpose of energy saving. We extended NS-2, a popular network simulator, to model such combined network scenarios. Using a number of different routing strategies, we then model and evaluate the network performance of DR programs in smart homes in such a combined network.展开更多
研究了电力线噪声分离网络技术,包括网络拓扑优化、分离网络元器件性能改善以及利用散射参数测量进行分离网络参数提取等。结果表明,上述技术可明显提高分离网络性能,如插损提高约3dB,噪声抑制比提高15dB以上。此外还分别完成了基于噪...研究了电力线噪声分离网络技术,包括网络拓扑优化、分离网络元器件性能改善以及利用散射参数测量进行分离网络参数提取等。结果表明,上述技术可明显提高分离网络性能,如插损提高约3dB,噪声抑制比提高15dB以上。此外还分别完成了基于噪声分离网络的开关电源电力线传导噪声和电力载波通信(power line communication,PLC)中的电力线辐射干扰噪声诊断抑制2个实验,验证了文中方法有效性。展开更多
High-speed broadband power line communication(BPL)is a novel and practicable technique for NetatHome or home area local area networking(LAN).Because of the characteristics of BPL,the electromagnetic wave emitted from ...High-speed broadband power line communication(BPL)is a novel and practicable technique for NetatHome or home area local area networking(LAN).Because of the characteristics of BPL,the electromagnetic wave emitted from the BPL transmission media will influence the indoor electromagnetic environment,which would also affect the performance of other wireless communications.Based on the analysis of the communication channel characteristic,network impedance and attenuation characteristic of the BPL,this paper proposes a novel model for calculating the BPL radiation and the computer simulation model,which are proved by the coherence of the simulation and the test data.The interferences from the high-speed BPL to indoor wireless communications are analyzed to stipulate the standards of high-speed BPL in the future.展开更多
The topology of in-home power line communication(PLC) networks varies frequently, which makes traditional routing algorithms failure. To solve this problem, an end-to-end transmission time for remaining path(TTRP) met...The topology of in-home power line communication(PLC) networks varies frequently, which makes traditional routing algorithms failure. To solve this problem, an end-to-end transmission time for remaining path(TTRP) metric-based opportunistic routing(TTRPOR) is proposed. Since a local broadcasting scheme is adopted, the algorithm can find the optimal path for forwarding packets in a dynamic PLC network. The closed-form of the outage probability for a PLC channel is derived to estimate the TTRP. It is proved that the average throughput can achieve maximum as the metric TTRP is utilized to sort candidate forwarding nodes.Numerical results show that the end-to-end throughput of networks with TTRPOR, outperforms that of the network adopting DSR and EXOR, especially for the case of varying-topology in-home PLC networks.展开更多
Particle filtering (PF) algorithm has the powerful potential for coping with difficult non-linear and non-Gaussian problems. Aiming at non-linear, non-Gaussian and time-varying characteristics of power line channel,...Particle filtering (PF) algorithm has the powerful potential for coping with difficult non-linear and non-Gaussian problems. Aiming at non-linear, non-Gaussian and time-varying characteristics of power line channel, a time-varying channel estimation scheme combined PF algorithm with decision feedback method is proposed. In the proposed scheme, firstly the indoor power line channel is measured using the pseudo-noise (PN) correlation method, and a first-order dynamic autoregressive (AR) model is set up to describe the measured channel, then, the channel states are estimated dynamically from the received signals by exploiting the proposed scheme. Meanwhile, due to the complex noise distribution of power line channel, the performance of channel estimation based on the proposed scheme under the Middleton class A impulsive noise environment is analyzed. Comparisons are made with the channel estimation scheme respectively based on least square (LS), Kalman filtering (KF) and the proposed algorithm. Simulation indicates that PF algorithm dealing with this power line channel estimation difficult non-linear and non-Gaussian problems performance is superior to those of LS and KF respectively, so the proposed scheme achieves higher estimation accuracy. Therefore, it is confirmed that PF algorithm has its own unique advantage for power line channel estimation.展开更多
A hybrid model for broadband multiple-input multiple-output(MIMO) relay-aided indoor power line communications(PLC) system was proposed in this paper. The proposed model combines the top-down and bottom-up approaches ...A hybrid model for broadband multiple-input multiple-output(MIMO) relay-aided indoor power line communications(PLC) system was proposed in this paper. The proposed model combines the top-down and bottom-up approaches and extends to a two-hop relay-aided cooperative system with variable gain relay in amplify-and-forward(AF) mode. Based on the proposed PLC model and generated channel, the channel statistical characteristics are further investigated in 2 MHz^100 MHz bandwidth. Simulated results show that the proposed model overcomes the difficulties that the existing models need a lot of topological information of the network or measurements information. It provides a practical simulation analysis method for cooperative relay MIMO-PLC system. The results also show that cooperative MIMO relaying communications can improve the indoor PLC performances and communication reliability.展开更多
Most existing media access control(MAC) protocols in power line communication(PLC) networks just discard the colliding data packets when collision occurs.The collision deteriorates throughput and delay performance of ...Most existing media access control(MAC) protocols in power line communication(PLC) networks just discard the colliding data packets when collision occurs.The collision deteriorates throughput and delay performance of system under high traffic conditions.This article presents a novel media access scheme with fast collision resolution for in-home power line networks.It works by first recognizing the colliding stations through detecting the inserted unique ID sequence ahead of data packets,then the source nodes retransmitting their packets immediately after the collision slot.The proposed protocol maintains the benefits of ALOHA systems.It needs no scheduling overhead and is suitable for bursty sources,such as multimedia data packets.Computer simulations have demonstrated that this approach can achieve high throughput due to its ability of resolving collisions.展开更多
This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-poin...This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-point digital signal processor (DSP) along with 4 MSPS analog-to-digital converter (ADC) is used to develop the intelligent electronic device. An optimized algorithm to process the analog signal in real-time and to extract the meaningful result using signal processing techniques has been implemented on the device. A laboratory environment has setup with all the necessary equipment including the development of the load model to evaluate the performance of the IED. Smart meter and concentrator is also connected to the low voltage (LV) network to monitor the PLC communication using the IED. The device has been tested in the laboratory and it has produced very promising results for time domain as well as frequency domain analysis. Those results imply that the IED is fully capable of monitoring high frequency disturbances in CENELEC PLC band.展开更多
电磁兼容性(Electromagnetic Compatibility,EMC)是电力线通信(Power Line Communication,PLC)系统的关键技术之一。首先介绍了PLC技术的发展概况和相应EMC研究的基本情况;并介绍了有代表性的国家或地区和重要的标准化组织在PLC技术的EM...电磁兼容性(Electromagnetic Compatibility,EMC)是电力线通信(Power Line Communication,PLC)系统的关键技术之一。首先介绍了PLC技术的发展概况和相应EMC研究的基本情况;并介绍了有代表性的国家或地区和重要的标准化组织在PLC技术的EMC法律法规和标准方面的最新进展;然后介绍了我国在该领域的试验结果和研究成果;最后指出该领域存在的问题、同时对发展方向提出建议。上述研究总结了PLC技术的EMC法规和标准化的最新进展,可作为我国发展PLC时制定合理的EMC法规和管理制度的有益参考。展开更多
文摘Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.
文摘In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office automation, in-vehicle data communication etc. In this paper we present an architecture for the physical layer of a PLC transceiver based on Orthogonal Frequency Division Multiplexing (OFDM) and the impact on multipath distortion for PLC transmission in terms of bit error rate. Since there is no standard PLC channel model available, a widely accepted multipath channel model is used for simulation purpose. Simulation results as well as FPGA synthesis verify the effectiveness of the proposed architecture for PLC modem design at 110 Mbps data rate.
基金the National Natural Science Foundation of China(No.60072048)
文摘This letter derives the Equivalent M-band Discrete Wavelet(EMDW) transmission mode of Orthogonal Frequency Division Multiplexing(OFDM) transmission systems, and presents a new Quadrature M-band Discrete Wavelet(QMDW) based OFDM-CDMA(Code Division Multiple Access) communication systems for high speed Power Line Communication (PLC) channels.This system gives much better robustness to Inter-Channel Interference (ICI), Multi-User Interference (MUI) and noise interference, which is verified by simulation.
文摘Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queueing theoretic framework. The proposed PLC network model consists of a base station (BS), which is located at a transformer station and connected to the backbone communication networks, and a number of subscriber stations that are interconnected with each other and with the BS via the power line transmission medium. An orthogonal frequency division multiplexing based technique is assumed for forming the transmission channels in a frequency spectrum. The channels are subject to failure during service due to noise. We determine the steady-state solution of the proposed model and derive a set of performance metrics of interest. Numerical and simulation results are presented to provide further insights into the analytical results. The proposed modeling method is expected to be used for evaluation and design of future PLC networks.
基金Supported by Headquarters Technology Project of State Grid Corporation of China(No.5700-202118203A-0-0-00)。
文摘Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and reducing the cost.But it suffers from the impulsive noise because it introduces significant time variance into the power line channel.In this paper,a polar codes based orthogonal frequency division multiplexing(OFDM)PLC system is proposed to deal with the impulsive noise and thereby improve the transmission performance.Firstly,the impulsive noise is modelled with a multi-damped sine function by analyzing the time behavior of impulse events.Then the polar codes are used to combat the impulsive noise of PLC channel,and a low complexity bit-flipping decoding method based on CRC-aided successive cancellation list(CA-SCL)decoding algorithm is proposed.Simulations evaluate the proposed decoding algorithm and the results validate the suggested polar codes based OFDM-PLC scheme which can improve the BER performance of PLC with impulsive interference.
文摘Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the interest of both utilities and residents. They help to achieve load balance and increase the grid reliability by encouraging residents to reduce their power usage during peak load periods in return for incentives. To automate this process, appliances, in-house sensors, and the AMI controller need to be networked together. In this paper, we compare mainstream network technologies applicable to home appliance control and propose a solution combining Power Line Communication (PLC) with wireless communication in smart homes for the purpose of energy saving. We extended NS-2, a popular network simulator, to model such combined network scenarios. Using a number of different routing strategies, we then model and evaluate the network performance of DR programs in smart homes in such a combined network.
文摘研究了电力线噪声分离网络技术,包括网络拓扑优化、分离网络元器件性能改善以及利用散射参数测量进行分离网络参数提取等。结果表明,上述技术可明显提高分离网络性能,如插损提高约3dB,噪声抑制比提高15dB以上。此外还分别完成了基于噪声分离网络的开关电源电力线传导噪声和电力载波通信(power line communication,PLC)中的电力线辐射干扰噪声诊断抑制2个实验,验证了文中方法有效性。
基金supported by the National Natural Science Foundation of China (Grant Nos.60671055,60771060).
文摘High-speed broadband power line communication(BPL)is a novel and practicable technique for NetatHome or home area local area networking(LAN).Because of the characteristics of BPL,the electromagnetic wave emitted from the BPL transmission media will influence the indoor electromagnetic environment,which would also affect the performance of other wireless communications.Based on the analysis of the communication channel characteristic,network impedance and attenuation characteristic of the BPL,this paper proposes a novel model for calculating the BPL radiation and the computer simulation model,which are proved by the coherence of the simulation and the test data.The interferences from the high-speed BPL to indoor wireless communications are analyzed to stipulate the standards of high-speed BPL in the future.
基金supported in part by Open Research Fund of National Key Laboratory of Electromagnetic EnvironmentChina Research Institute of Radiowave Propagation (Grant No. 201500013)+3 种基金Open Research Fund of National Mobile Communications Research LaboratoryJiangsu Provincial Science Foundation Project (Grant No. BK20150786)Southeast University (Grant No. 2013D02)National Natural Science Foundation of China (Grants Nos. 61501238, 61271230, 61472190)
文摘The topology of in-home power line communication(PLC) networks varies frequently, which makes traditional routing algorithms failure. To solve this problem, an end-to-end transmission time for remaining path(TTRP) metric-based opportunistic routing(TTRPOR) is proposed. Since a local broadcasting scheme is adopted, the algorithm can find the optimal path for forwarding packets in a dynamic PLC network. The closed-form of the outage probability for a PLC channel is derived to estimate the TTRP. It is proved that the average throughput can achieve maximum as the metric TTRP is utilized to sort candidate forwarding nodes.Numerical results show that the end-to-end throughput of networks with TTRPOR, outperforms that of the network adopting DSR and EXOR, especially for the case of varying-topology in-home PLC networks.
基金supported by the National Natural Science Foundation of China (61202399)
文摘Particle filtering (PF) algorithm has the powerful potential for coping with difficult non-linear and non-Gaussian problems. Aiming at non-linear, non-Gaussian and time-varying characteristics of power line channel, a time-varying channel estimation scheme combined PF algorithm with decision feedback method is proposed. In the proposed scheme, firstly the indoor power line channel is measured using the pseudo-noise (PN) correlation method, and a first-order dynamic autoregressive (AR) model is set up to describe the measured channel, then, the channel states are estimated dynamically from the received signals by exploiting the proposed scheme. Meanwhile, due to the complex noise distribution of power line channel, the performance of channel estimation based on the proposed scheme under the Middleton class A impulsive noise environment is analyzed. Comparisons are made with the channel estimation scheme respectively based on least square (LS), Kalman filtering (KF) and the proposed algorithm. Simulation indicates that PF algorithm dealing with this power line channel estimation difficult non-linear and non-Gaussian problems performance is superior to those of LS and KF respectively, so the proposed scheme achieves higher estimation accuracy. Therefore, it is confirmed that PF algorithm has its own unique advantage for power line channel estimation.
基金supported by the Natural Science Foundation of Hebei Province of China (F2019201362,E2019502186)the Hebei University One Province One University Special Fundthe Fundamental Research Funds for the Central Universities (2018MS096).
文摘A hybrid model for broadband multiple-input multiple-output(MIMO) relay-aided indoor power line communications(PLC) system was proposed in this paper. The proposed model combines the top-down and bottom-up approaches and extends to a two-hop relay-aided cooperative system with variable gain relay in amplify-and-forward(AF) mode. Based on the proposed PLC model and generated channel, the channel statistical characteristics are further investigated in 2 MHz^100 MHz bandwidth. Simulated results show that the proposed model overcomes the difficulties that the existing models need a lot of topological information of the network or measurements information. It provides a practical simulation analysis method for cooperative relay MIMO-PLC system. The results also show that cooperative MIMO relaying communications can improve the indoor PLC performances and communication reliability.
文摘Most existing media access control(MAC) protocols in power line communication(PLC) networks just discard the colliding data packets when collision occurs.The collision deteriorates throughput and delay performance of system under high traffic conditions.This article presents a novel media access scheme with fast collision resolution for in-home power line networks.It works by first recognizing the colliding stations through detecting the inserted unique ID sequence ahead of data packets,then the source nodes retransmitting their packets immediately after the collision slot.The proposed protocol maintains the benefits of ALOHA systems.It needs no scheduling overhead and is suitable for bursty sources,such as multimedia data packets.Computer simulations have demonstrated that this approach can achieve high throughput due to its ability of resolving collisions.
文摘This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-point digital signal processor (DSP) along with 4 MSPS analog-to-digital converter (ADC) is used to develop the intelligent electronic device. An optimized algorithm to process the analog signal in real-time and to extract the meaningful result using signal processing techniques has been implemented on the device. A laboratory environment has setup with all the necessary equipment including the development of the load model to evaluate the performance of the IED. Smart meter and concentrator is also connected to the low voltage (LV) network to monitor the PLC communication using the IED. The device has been tested in the laboratory and it has produced very promising results for time domain as well as frequency domain analysis. Those results imply that the IED is fully capable of monitoring high frequency disturbances in CENELEC PLC band.