期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Measuring Method of Radius of Curvature Based on Dual-Frequency Laser Interferometer
1
作者 Wenlong Zhang Liang Miao Yu Liu 《Optics and Photonics Journal》 2016年第8期209-214,共6页
In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferome... In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferometer based on cat’s eye and confocal method. Through analyzing the error source models of radius of curvature testing, optical configuration of the testing device has been optimized. Precise environment control and real-time monitoring system is also established to reduce the errors caused by environment. Through the above processes, the radius of curvature measurement relative accuracy is better than 2 ppm. One optical sphere, R88.5 mm, test aperture 59 mm, has been tested. Testing result is 88499.465 ± 0.176 μm, meeting the design requirement. The method has high accuracy and practical advantages. 展开更多
关键词 radius of curvature Cat’s Eye and Confocal Method Dual-Frequency Laser Interferometer
下载PDF
Research on characteristics of acoustic signal of typical partial discharge models 被引量:1
2
作者 Hang Ji Xing Lei +3 位作者 Qiang Xu Chengjun Huang Ting Ye Shangqing Yuan 《Global Energy Interconnection》 EI CAS CSCD 2022年第1期118-130,共13页
The pulse current method,acoustic and ultrasonic partial discharge(PD)detection,and voiceprint PD detection are commonly used detection methods for the PD detection of power equipment.To study the characteristics of P... The pulse current method,acoustic and ultrasonic partial discharge(PD)detection,and voiceprint PD detection are commonly used detection methods for the PD detection of power equipment.To study the characteristics of PD signals of typical discharge models based on the principles of the above three detection methods,an acoustic detection experimental system consisting of a needle-tip model and a surface model was built.Acoustic tests were carried out on needle-tip models with different curvature radii and surface discharge models with different lengths of conductive paste.The experimental results showed that acoustic and ultrasonic PD detection and voiceprint PD detection exhibited different sensitivities to the needle-tip discharge models,and the combination of acoustic and ultrasonic PD and voiceprint PD detection was more beneficial for the comprehensive detection of cable PD signals.Based on voiceprint recognition technology,this study drew FFT(Fast Fourier Transformation)diagrams of different types of PD acoustic signals and analyzed the differences in the ultrasonic signal frequency distribution.The frequency band of the voiceprint PD signal of the needle-tip discharge models was concentrated in the range 17-27 kHz,and the frequency band of the voiceprint PD signal of the conductive paste discharge models was concentrated in the range 20-25 kHz.The measurement of voiceprint PD signals in these frequency bands were strengthened when the PD of a cable was detected on-site,which provides the basis for the use of the cable model for on-site PD detection. 展开更多
关键词 Needle-tip model radius of curvature Surface model Discharge capacity Number of pulses
下载PDF
Proportion and characteristic of emmetropia in schoolchildren aged 6-11y:the Shenzhen elementary school eye study 被引量:1
3
作者 Xian-Ming Jiang Ying-Ying Lu +2 位作者 Xiao Han Qian Tan Jun-Shu Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第12期1983-1989,共7页
AIM:To investigate the proportion and characteristic of emmetropia in schoolchildren aged 6-11,especially estimate the normal value of ocular biometric parameters of emmetropia.METHODS:A population-based cross-section... AIM:To investigate the proportion and characteristic of emmetropia in schoolchildren aged 6-11,especially estimate the normal value of ocular biometric parameters of emmetropia.METHODS:A population-based cross-sectional study was conducted on children aged 6-11 y in Shenzhen.Totally,2386 schoolchildren from two primary schools were involved.The axial length(AL)and the corneal radius of curvature(CRC)were measured by partial coherence laser interferometry.Noncycloplegic refraction and refractive astigmatism(RA)was measured using autorefraction.The axial length-to-corneal radius of curvature ratio(AL/CRC),corneal astigmatism(CA)and spherical equivalent refraction(SER)were calculated.RESULTS:The proportion of emmetropia in elementary school students was 41.30%.This percentage decreased gradually from 6 to 11 years of age and decreased rapidly after 9 years of age.The mean and 95%CI of each parameter were provided for boys and girls aged 6 to 11 years of age with emmetropia according to each age group.The change trend of parameters of boys and girls are similar.After 7 years of age,the AL of non-emmetropia started to increase faster than that of emmetropia.The change trend of AL/CRC was the same as that of AL.The other parameters tend to be stable after 7 years of age.CONCLUSION:The age of 7-9 is an important period for the changes of refractive state and ocular biometric parameters of primary school students,and it is a special focus period for children myopia prevention.The normal value and variation of ocular biometric parameters of emmetropia can provide the basis for the clinical judgment of whether or not children’s ocular biometric parameters obtained by single measurement and changes obtained by multiple measurements are abnormal. 展开更多
关键词 axial length corneal radius of curvature MYOPIA emmetropia children
下载PDF
Analysis of ocular structural parameters and higher-order aberrations in Chinese children with myopia 被引量:1
4
作者 Xue Li Qi Hu +3 位作者 Qian-Ru Wang Zi-Qing Feng Fan Yang Chun-Yu Du 《World Journal of Clinical Cases》 SCIE 2021年第27期8035-8043,共9页
BACKGROUND Myopia and high myopia are global public health concerns.Patients with high myopia account for 0.5%-5.0%of the global population.AIM To examine diopters,axial length(AL),higher-order aberrations,and other o... BACKGROUND Myopia and high myopia are global public health concerns.Patients with high myopia account for 0.5%-5.0%of the global population.AIM To examine diopters,axial length(AL),higher-order aberrations,and other ocular parameters in Chinese children with myopia,to analyze the influence of structural parameters associated with myopia on visual quality,and to provide a theoretical basis for the prevention and treatment of childhood myopia and high myopia.METHODS This study included 195 children aged 6–17 years with myopia.The AL was measured with an ultrasonic ophthalmic diagnostic instrument,and the aberrations,corneal curvature(minimum K1,maximum K2,and average Km),central corneal thickness,anterior chamber depth,and anterior chamber angle were measured using a Sirius three-dimensional anterior segment analyzer.Using a standard formula,the corneal radius of curvature R(337.3/Km)and AL/R values were obtained.RESULTS The diopter of high myopia compared with low-middle myopia was correlated with age and AL(r=-0.336,-0.405,P<0.001),and AL of high myopia was negatively correlated with K1,K2,and Km(r=-0.673,-0.661,and-0.680,respectively;P<0.001),and positively correlated with age and the anterior chamber depth(r=0.214 and 0.275,respectively;P<0.05).AL/R was more closely related to diopter than AL in children with myopia,and 94.4%of children with myopia had an AL/R of>3.00.CONCLUSION The ocular structural parameters of children change because of different diopters.AL/R is more specific and sensitive than AL in evaluating the refractive status of myopia in children.An AL/R of>3.00 may be used as a specific index of myopia in children.There are differences in AL/R between high myopia and low-middle myopia,which can be used for the classification of ametropia.The degree of myopia has a certain influence on higher-order aberrations. 展开更多
关键词 MYOPIA Higher-order aberrations DIOPTER Axial length Cornea radius of curvature
下载PDF
Gaussian wave formalism model for propagation of charged-particle beam through a first-order optical systems
5
作者 陈宝信 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第3期496-501,共6页
An elliptical Gaussian wave formalism model of a charged-particle beam is proposed by analogy with an elliptical Gaussian light beam. In the paraxial approximation, the charged-particle beam can be described as a whol... An elliptical Gaussian wave formalism model of a charged-particle beam is proposed by analogy with an elliptical Gaussian light beam. In the paraxial approximation, the charged-particle beam can be described as a whole by a complex radius of curvature in the real space domains. Therefore, the propagation and transform of charged-particle beam passing through a first-order optical system is represented by the ABCD-like law. As an example of the application of this model, the relation between the beam waist and the minimum beam spot at a fixed target is discussed. The result, well matches that from conventional phase space model, and proves that the Gaussian wave formalism model is highly effective and reasonable. 展开更多
关键词 complex radius of curvature transfer matrix ABCD-like law charged-particle beam
下载PDF
Space-Time Curvature Mode Quanta
6
作者 Philipp Kornreich 《Journal of Modern Physics》 2020年第12期1977-1992,共16页
Einstein theorized that Gravity is not a force derived from a potential that acts across a distance. It is a distortion of space and time in which we live by masses and energy. Consistent with Einstein’s theory, a mo... Einstein theorized that Gravity is not a force derived from a potential that acts across a distance. It is a distortion of space and time in which we live by masses and energy. Consistent with Einstein’s theory, a model of space-time curvature modes and associated curvature quanta in slightly warped space-time generated by a light Photon is derived. Both a Schr<span style="white-space:nowrap;">?</span>dinger and a Second Quantized representation of the space-time curvature mode quanta are calculated and are fourth rank tensors. The eigenvalues of these equations are radii of curvature, not energy. The Eigenfunctions are linear functions of the components of the tensor that describes the curvature of space-time. 展开更多
关键词 PHOTONS PHONONS GRAVITY General Relativity SPACE-TIME radius of curvature TENSOR
下载PDF
上一页 1 下一页 到第