This is the second paper of two, which describe the results of an integrated research effort to develop a four-step simplified approach for design of raft foundations against dip-slip (normal and thrust) fault ruptu...This is the second paper of two, which describe the results of an integrated research effort to develop a four-step simplified approach for design of raft foundations against dip-slip (normal and thrust) fault rupture. The first two steps dealing with fault rupture propagation in the free-field were presented in the companion paper. This paper develops an approximate analytical method to analyze soil-foundation-structure interaction (SFSI), involving two additional phenomena: (i) fault rupture diversion (Step 3); and (ii) modification of the vertical displacement profile (Step 4). For the first phenomenon (Step 3), an approximate energy-based approach is developed to estimate the diversion of a fault rupture due to presence of a raft foundation. The normalized critical load for complete diversion is shown to be a function of soil strength, coefficient of earth pressure at rest, bedrock depth, and the horizontal position of the foundation relative to the outcropping fault rupture. For the second phenomenon (Step 4), a heuristic approach is proposed, which "scans" through possible equilibrium positions to detect the one that best satisfies force and moment equilibrium. Thus, we account for the strong geometric nonlinearities that govern this interaction, such as uplifting and second order (P-△) effects. Comparisons with centrifuge-validated finite element analyses demonstrate the efficacy of the method. Its simplicity makes possible its utilization for preliminary design.展开更多
This study investigates the ground and structural response of adjacent raft foundations induced by largescale surcharge by ore in soft soil areas through a 130g centrifuge modeling test with an innovative layered load...This study investigates the ground and structural response of adjacent raft foundations induced by largescale surcharge by ore in soft soil areas through a 130g centrifuge modeling test with an innovative layered loading device.The prototype of the test is a coastal iron ore yard with a natural foundation of deep soft soil.Therefore,it is necessary to adopt some measures to reduce the influence of the large-scale surcharge on the adjacent raft foundation,such as installing stone columns for foundation treatment.Under an acceleration of 130 g,the model conducts similar simulations of iron ore,stone columns,and raft foundation structures.The tested soil mass has dimensions of 900 mm×700 mm×300 mm(lengthwidthdepth),which is remodeled from the soil extracted from the drilling holes.The test conditions are consistent with the actual engineering conditions and the effects of four-level loading conditions on the composite foundation of stone columns,unreinforced zone,and raft foundations are studied.An automatic layer-by-layer loading device was innovatively developed to simulate the loading process of actual engineering more realistically.The composite foundation of stone columns had a large settlement after the loading,forming an obvious settlement trough and causing the surface of the unreinforced zone to rise.The 12 m surcharge loading causes a horizontal displacement of 13.19 cm and a vertical settlement of 1.37 m in the raft foundation.The stone columns located on both sides of the unreinforced zone suffered significant shear damage at the sand-mud interface.Due to the reinforcement effect of stone columns,the sand layer below the top of the stone columns moves less.Meanwhile,the horizontal earth pressure in the raft foundation zone increases slowly.The stone columns will form new drainage channels and accelerate the dissipation of excess pore pressure.展开更多
Traditionally seismic design of structures supported on piled raft foundation is performed by considering fixed base conditions, while the pile head is also considered to be fixed for the design of the pile foundation...Traditionally seismic design of structures supported on piled raft foundation is performed by considering fixed base conditions, while the pile head is also considered to be fixed for the design of the pile foundation. Major drawback of this assumption is that it cannot capture soil-foundation-structure interaction due to flexibility of soil or the inertial interaction involving heavy foundation masses. Previous studies on this subject addressed mainly the intricacy in modelling of dynamic soil structure interaction (DSSI) but not the implication of such interaction on the distribution of forces at various elements of the pile foundation and supported structure. A recent numerical study by the authors showed significant change in response at different elements of the piled raft supported structure when DSSI effects are considered. The present study is a limited attempt in this direction, and it examines such observations through shake table tests. The effect of DSSI is examined by comparing dynamic responses from fixed base scaled down model structures and the overall systems. This study indicates the possibility of significant underestimation in design forces for both the column and pile if designed under fixed base assumption. Such underestimation in the design forces may have serious implication in the design of a foundation or structural element.展开更多
To reveal the bearing capacity of the X-section concrete piles pile raft foundation in silica sand,a series of vertical load tests are carried out.The X-section concrete piles are compared with circular section pile w...To reveal the bearing capacity of the X-section concrete piles pile raft foundation in silica sand,a series of vertical load tests are carried out.The X-section concrete piles are compared with circular section pile with the same section area.The load−settlement curves,axial force and skin friction,strain on concave and convex edge of the pile,pile-sand stress ratio,distributions of side and tip resistance are presented.The results show that bearing capacity of the X section concrete pile raft foundation is much larger than that of the circular pile raft foundation.Besides,compared with the circular pile,the peak axial force of X-section piles under raft is deeper and smaller while the neutral point of X-section concrete pile is deeper.Moreover,the strain on the concave edge is much larger than that on the convex edge of the pile,and the convex edge has more potential in bearing capacity as the vertical load increases.The X-section pile has higher pile-sand stress ratios and load-sharing between side resistance and tip resistance.Above all,the X-section concrete pile can significantly increase the bearing capacity of pile-raft foundations in silica sand.展开更多
The mechanism of long-short composite piled raft foundation was discussed. Assuming the relationship between shear stress and shear strain of the surrounding soil was elasto-plastic, shear displacement method was empl...The mechanism of long-short composite piled raft foundation was discussed. Assuming the relationship between shear stress and shear strain of the surrounding soil was elasto-plastic, shear displacement method was employed to establish the different explicit relational equations between the load and the displacement at the top of pile in either elastic or elasto-plastic period. Then Mylonakis & Gazetas model was introduced to simulate the interaction between two piles or between piles and soil. Considering the effect of cushion, the flexible coefficients of interaction were provided, With the addition of a relevant program, the settlement calculation for long-short composite piled raft foundation was developed which could be used to account for the interaction of piles, soil and cushion. Finally, the calculation method was used to analyze an engineering example. The calculated value of settlement is 10.2 ram, which is close to the observed value 8.8 mm.展开更多
The clay soils of the city of Douala are constantly saturated with water, which permanently favors the hydrodynamic behavior of the soils (swelling or consolidation). This phenomenon can cause serious disturbances in ...The clay soils of the city of Douala are constantly saturated with water, which permanently favors the hydrodynamic behavior of the soils (swelling or consolidation). This phenomenon can cause serious disturbances in the structure of buildings resulting in the appearance of cracks in structures (buildings, road bridge, viaduct, etc.). The foundation raft is a very important structure in the dimensioning of structures. Given the soil-structure interactions, its mechanical characteristics must be the subject of a special study linked to the building environment. In this article, we present a study of the mechanical behavior of a foundation raft anchored in a laminate floor. The aim is to highlight the influence of the mechanical properties of the foundation soil on the evolution of the mechanical behavior of the raft. The method used is a numerical simulation. A physical model taking into account a 5-storey building based in Douala in the Denver district is studied. The foundation on the raft foundation of this building follows an elastic constitutive law with Mazars damage, and rests on a laminated soil of plastic elastic model with Camclay plasticity criterion. The ground-raft and ground-ground interfaces are carried out with the finite elements joined to three nodes (JOI3), and obey the Coulomb model;it is an expansion joint model with Mohr-Coulomb type criterion and associated flow. The numerical resolution is carried out by the finite element method, and the numerical simulations via the Cast3M calculation code. The results from the simulations show that the mechanical characteristics of foundation soils, in this case the water content, the compactness, the state of consolidation, greatly influence the mechanical behavior of the foundation slab. There is indeed a significant settlement and a great deformation of the raft foundation when the water content of the soil layers increases, and when the states of consolidation and compactness are low. This article allows us to predict and control the evolution of the behavior of the ground-structure interface of a raft foundation and to adopt a new model appropriate for the sizing of civil engineering structures.展开更多
Foundation pit excavation engineering is an old subject full of decision making. Yet, it still deserves further research due to the associated high failure cost and the complexity of the geological conditions and/or t...Foundation pit excavation engineering is an old subject full of decision making. Yet, it still deserves further research due to the associated high failure cost and the complexity of the geological conditions and/or the surrounding existing infrastructure around it. This article overviews the risk control practice of foundation pit excavation projects in close proximity to <span style="font-family:Verdana;">existing</span><span style="font-family:Verdana;"> disconnected piled raft. More focus is given to geotechnical aspects. The review begins with achievements to ensure excavation performance </span><span style="font-family:Verdana;">requirements,</span><span style="font-family:Verdana;"> and follows to discuss the complex </span><span style="font-family:Verdana;">soil structure</span><span style="font-family:Verdana;"> interaction involved among the fundamental components</span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">: </span></span></span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;">the retaining wall, mat, piles, cushion, and the soil. After bringing consensus points to practicing engineers and </span><span style="font-family:Verdana;">decision makers</span><span style="font-family:Verdana;">, it then suggests possible future research directions.</span></span></span></span>展开更多
The mass fiat raft foundation Section is large and Cement is in large quantities, the temperature changes in the larger cement hydration heat of the water releasing, the temperature stress is main reason reducing crac...The mass fiat raft foundation Section is large and Cement is in large quantities, the temperature changes in the larger cement hydration heat of the water releasing, the temperature stress is main reason reducing cracking. According to the basement of a project of Guangzhou large slab raft foundation engineering as an example, Discussing the construction technology measures of early crack of large volume concrete of raft plate in the process of construction,. The results show that it Can effectively prevents the slab foundation structure cracking and achieves good results through controlling Concrete materials and concrete temperature Parameter such as the lifting machine temperature and the pouring temperature and the expansion joint or the whole pouring length.展开更多
Foundation is considered as one of the main parts of any structure. The type of foundation used is highly dependent on the type and properties of soil. The design of foundations requires many factors that should be de...Foundation is considered as one of the main parts of any structure. The type of foundation used is highly dependent on the type and properties of soil. The design of foundations requires many factors that should be defined. There are number of differences in the geological and soil conditions in Iraq. As a consequence, these differences are reflected on the type of foundation to be used. Despite these differences, same materials and style of buildings are used all over Iraq. The main problems of Iraqi soil are high gypsum content, salinity and shallow water table depth. These factors that influence the foundations are the soil properties and the amount of loads that transmitted by the superstructure. The situation has been analysed through a case study which illustrated the link between soil and foundation types in three different parts of Iraq (Mosul, Baghdad and Basra). One building was analysed using "STAAD (structural analysis and design). Pro" software in these regions. It is evident that Iraqi designers and engineers require local code to define all the loads, materials and design of the foundation to be used. The use of local materials might be very effective from both engineering and economic perspectives.展开更多
基金OSE (the Greek Railway Organization)the EU Fifth Framework Programme Under Grant No. EVG1-CT-2002-00064
文摘This is the second paper of two, which describe the results of an integrated research effort to develop a four-step simplified approach for design of raft foundations against dip-slip (normal and thrust) fault rupture. The first two steps dealing with fault rupture propagation in the free-field were presented in the companion paper. This paper develops an approximate analytical method to analyze soil-foundation-structure interaction (SFSI), involving two additional phenomena: (i) fault rupture diversion (Step 3); and (ii) modification of the vertical displacement profile (Step 4). For the first phenomenon (Step 3), an approximate energy-based approach is developed to estimate the diversion of a fault rupture due to presence of a raft foundation. The normalized critical load for complete diversion is shown to be a function of soil strength, coefficient of earth pressure at rest, bedrock depth, and the horizontal position of the foundation relative to the outcropping fault rupture. For the second phenomenon (Step 4), a heuristic approach is proposed, which "scans" through possible equilibrium positions to detect the one that best satisfies force and moment equilibrium. Thus, we account for the strong geometric nonlinearities that govern this interaction, such as uplifting and second order (P-△) effects. Comparisons with centrifuge-validated finite element analyses demonstrate the efficacy of the method. Its simplicity makes possible its utilization for preliminary design.
基金funding support from National Key Research and Development Program of China(Grant No.2021YFF0502200)National Natural Science Foundation of China(Grant Nos.52022070 and 51978516).
文摘This study investigates the ground and structural response of adjacent raft foundations induced by largescale surcharge by ore in soft soil areas through a 130g centrifuge modeling test with an innovative layered loading device.The prototype of the test is a coastal iron ore yard with a natural foundation of deep soft soil.Therefore,it is necessary to adopt some measures to reduce the influence of the large-scale surcharge on the adjacent raft foundation,such as installing stone columns for foundation treatment.Under an acceleration of 130 g,the model conducts similar simulations of iron ore,stone columns,and raft foundation structures.The tested soil mass has dimensions of 900 mm×700 mm×300 mm(lengthwidthdepth),which is remodeled from the soil extracted from the drilling holes.The test conditions are consistent with the actual engineering conditions and the effects of four-level loading conditions on the composite foundation of stone columns,unreinforced zone,and raft foundations are studied.An automatic layer-by-layer loading device was innovatively developed to simulate the loading process of actual engineering more realistically.The composite foundation of stone columns had a large settlement after the loading,forming an obvious settlement trough and causing the surface of the unreinforced zone to rise.The 12 m surcharge loading causes a horizontal displacement of 13.19 cm and a vertical settlement of 1.37 m in the raft foundation.The stone columns located on both sides of the unreinforced zone suffered significant shear damage at the sand-mud interface.Due to the reinforcement effect of stone columns,the sand layer below the top of the stone columns moves less.Meanwhile,the horizontal earth pressure in the raft foundation zone increases slowly.The stone columns will form new drainage channels and accelerate the dissipation of excess pore pressure.
文摘Traditionally seismic design of structures supported on piled raft foundation is performed by considering fixed base conditions, while the pile head is also considered to be fixed for the design of the pile foundation. Major drawback of this assumption is that it cannot capture soil-foundation-structure interaction due to flexibility of soil or the inertial interaction involving heavy foundation masses. Previous studies on this subject addressed mainly the intricacy in modelling of dynamic soil structure interaction (DSSI) but not the implication of such interaction on the distribution of forces at various elements of the pile foundation and supported structure. A recent numerical study by the authors showed significant change in response at different elements of the piled raft supported structure when DSSI effects are considered. The present study is a limited attempt in this direction, and it examines such observations through shake table tests. The effect of DSSI is examined by comparing dynamic responses from fixed base scaled down model structures and the overall systems. This study indicates the possibility of significant underestimation in design forces for both the column and pile if designed under fixed base assumption. Such underestimation in the design forces may have serious implication in the design of a foundation or structural element.
基金Project(51878103)supported by the National Natural Science Foundation of ChinaProject(2016YFE0200100)supported by the National Key Research and Development Program of China。
文摘To reveal the bearing capacity of the X-section concrete piles pile raft foundation in silica sand,a series of vertical load tests are carried out.The X-section concrete piles are compared with circular section pile with the same section area.The load−settlement curves,axial force and skin friction,strain on concave and convex edge of the pile,pile-sand stress ratio,distributions of side and tip resistance are presented.The results show that bearing capacity of the X section concrete pile raft foundation is much larger than that of the circular pile raft foundation.Besides,compared with the circular pile,the peak axial force of X-section piles under raft is deeper and smaller while the neutral point of X-section concrete pile is deeper.Moreover,the strain on the concave edge is much larger than that on the convex edge of the pile,and the convex edge has more potential in bearing capacity as the vertical load increases.The X-section pile has higher pile-sand stress ratios and load-sharing between side resistance and tip resistance.Above all,the X-section concrete pile can significantly increase the bearing capacity of pile-raft foundations in silica sand.
基金Project (50378036) supported by the National Natural Science Foundation of China
文摘The mechanism of long-short composite piled raft foundation was discussed. Assuming the relationship between shear stress and shear strain of the surrounding soil was elasto-plastic, shear displacement method was employed to establish the different explicit relational equations between the load and the displacement at the top of pile in either elastic or elasto-plastic period. Then Mylonakis & Gazetas model was introduced to simulate the interaction between two piles or between piles and soil. Considering the effect of cushion, the flexible coefficients of interaction were provided, With the addition of a relevant program, the settlement calculation for long-short composite piled raft foundation was developed which could be used to account for the interaction of piles, soil and cushion. Finally, the calculation method was used to analyze an engineering example. The calculated value of settlement is 10.2 ram, which is close to the observed value 8.8 mm.
文摘The clay soils of the city of Douala are constantly saturated with water, which permanently favors the hydrodynamic behavior of the soils (swelling or consolidation). This phenomenon can cause serious disturbances in the structure of buildings resulting in the appearance of cracks in structures (buildings, road bridge, viaduct, etc.). The foundation raft is a very important structure in the dimensioning of structures. Given the soil-structure interactions, its mechanical characteristics must be the subject of a special study linked to the building environment. In this article, we present a study of the mechanical behavior of a foundation raft anchored in a laminate floor. The aim is to highlight the influence of the mechanical properties of the foundation soil on the evolution of the mechanical behavior of the raft. The method used is a numerical simulation. A physical model taking into account a 5-storey building based in Douala in the Denver district is studied. The foundation on the raft foundation of this building follows an elastic constitutive law with Mazars damage, and rests on a laminated soil of plastic elastic model with Camclay plasticity criterion. The ground-raft and ground-ground interfaces are carried out with the finite elements joined to three nodes (JOI3), and obey the Coulomb model;it is an expansion joint model with Mohr-Coulomb type criterion and associated flow. The numerical resolution is carried out by the finite element method, and the numerical simulations via the Cast3M calculation code. The results from the simulations show that the mechanical characteristics of foundation soils, in this case the water content, the compactness, the state of consolidation, greatly influence the mechanical behavior of the foundation slab. There is indeed a significant settlement and a great deformation of the raft foundation when the water content of the soil layers increases, and when the states of consolidation and compactness are low. This article allows us to predict and control the evolution of the behavior of the ground-structure interface of a raft foundation and to adopt a new model appropriate for the sizing of civil engineering structures.
文摘Foundation pit excavation engineering is an old subject full of decision making. Yet, it still deserves further research due to the associated high failure cost and the complexity of the geological conditions and/or the surrounding existing infrastructure around it. This article overviews the risk control practice of foundation pit excavation projects in close proximity to <span style="font-family:Verdana;">existing</span><span style="font-family:Verdana;"> disconnected piled raft. More focus is given to geotechnical aspects. The review begins with achievements to ensure excavation performance </span><span style="font-family:Verdana;">requirements,</span><span style="font-family:Verdana;"> and follows to discuss the complex </span><span style="font-family:Verdana;">soil structure</span><span style="font-family:Verdana;"> interaction involved among the fundamental components</span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">: </span></span></span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;">the retaining wall, mat, piles, cushion, and the soil. After bringing consensus points to practicing engineers and </span><span style="font-family:Verdana;">decision makers</span><span style="font-family:Verdana;">, it then suggests possible future research directions.</span></span></span></span>
文摘The mass fiat raft foundation Section is large and Cement is in large quantities, the temperature changes in the larger cement hydration heat of the water releasing, the temperature stress is main reason reducing cracking. According to the basement of a project of Guangzhou large slab raft foundation engineering as an example, Discussing the construction technology measures of early crack of large volume concrete of raft plate in the process of construction,. The results show that it Can effectively prevents the slab foundation structure cracking and achieves good results through controlling Concrete materials and concrete temperature Parameter such as the lifting machine temperature and the pouring temperature and the expansion joint or the whole pouring length.
文摘Foundation is considered as one of the main parts of any structure. The type of foundation used is highly dependent on the type and properties of soil. The design of foundations requires many factors that should be defined. There are number of differences in the geological and soil conditions in Iraq. As a consequence, these differences are reflected on the type of foundation to be used. Despite these differences, same materials and style of buildings are used all over Iraq. The main problems of Iraqi soil are high gypsum content, salinity and shallow water table depth. These factors that influence the foundations are the soil properties and the amount of loads that transmitted by the superstructure. The situation has been analysed through a case study which illustrated the link between soil and foundation types in three different parts of Iraq (Mosul, Baghdad and Basra). One building was analysed using "STAAD (structural analysis and design). Pro" software in these regions. It is evident that Iraqi designers and engineers require local code to define all the loads, materials and design of the foundation to be used. The use of local materials might be very effective from both engineering and economic perspectives.