BACKGROUND At the end of December 2019,the world faced severe acute respiratory syndrome-coronavirus 2(SARS-CoV-2),which led to the outbreak of coronavirus disease 2019(COVID-19),associated with respiratory issues.Thi...BACKGROUND At the end of December 2019,the world faced severe acute respiratory syndrome-coronavirus 2(SARS-CoV-2),which led to the outbreak of coronavirus disease 2019(COVID-19),associated with respiratory issues.This virus has shown significant challenges,especially for senior citizens,patients with other underlying illnesses,or those with a sedentary lifestyle.Serological tests conducted early on have helped identify how the virus is transmitted and how to curb its spread.The study hypothesis was that the rapid serological test for SARS-CoV-2 antibodies could indicate the immunoreactive profile during the COVID-19 pandemic in a university population.AIM To conduct active surveillance for serological expression of anti-SARS-CoV-2 antibodies in individuals within a university setting during the COVID-19 pandemic.METHODS This sectional study by convenience sampling was conducted in a large university in Niteroi-RJ,Brazil,from March 2021 to July 2021.The study population consisted of students,faculty,and administrative staff employed by the university.A total of 3433 faculty members,60703 students,and 3812 administrative staff were invited to participate.Data were gathered through rapid serological tests to detect immunoglobulin(Ig)M and IgG against SARS-CoV-2.Theχ²or Fisher's exact test was used to conduct statistical analysis.A 0.20 significance level was adopted for variable selection in a multiple logistic regression model to evaluate associations.RESULTS A total of 1648 individuals were enrolled in the study.The proportion of COVID-19 positivity was 164/1648(9.8%).The adjusted logistic model indicate a positive association between the expression of IgM or IgG and age[odds ratio(OR)=1.16,95%CI:1.02-1.31](P<0.0024),individuals who had been in contact with a COVID-19-positive case(OR=3.49,95%CI:2.34-5.37)(P<0.001),those who had received the COVID-19 vaccine(OR=2.33,95%CI:1.61-3.35)(P<0.001)and social isolation(OR=0.59,95%CI:0.41-0.84)(P<0.004).The likelihood of showing a positive result increased by 16%with every ten-year increment.Conversely,adherence to social distancing measures decreased the likelihood by 41%.CONCLUSION These findings evidenced that the population became more exposed to the virus as individuals discontinued social distancing practices,thereby increasing the risk of infection for themselves.展开更多
Food safety is one of the major concerns in every country regardless of the economic and social development. The frequent occurrence of food scandals in the world has led the Chinese government to implement several st...Food safety is one of the major concerns in every country regardless of the economic and social development. The frequent occurrence of food scandals in the world has led the Chinese government to implement several strategies to fortify the food supply system to a high food safety standard. This relies heavily on laboratory testing services but conventional methods for detection of food contaminants and toxicants are limited by sophisticated sample preparation procedures, long analysis time, large instruments and professional personnel to meet the increasing demands. In this review, we have incorporated most of the current and potential rapid detection methods for many notorious food contaminants and toxicants including microbial agents, toxic ions, pesticides, veterinary drugs and preservatives, as well as detection of genetically modified food genes and adulterated edible oil. Development of rapid, accurate, easy-to-use and affordable testing methods could urge food handlers and the public to actively screen for food contaminants and toxicants instead of passively relying on monitoring by the government examination facility. This review also provides several recommendations including how to encourage the public to engage in the food safety management system and provide optimal education and financial assistance that may improve the current Chinese food safety control system.展开更多
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against ra...The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, Sl, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation展开更多
Authentication of pasta is currently determined using molecular biology-based techniques focusing on DNA as the target analyte. Whilst proven to be effective, these approaches can be criticised as being destructive, t...Authentication of pasta is currently determined using molecular biology-based techniques focusing on DNA as the target analyte. Whilst proven to be effective, these approaches can be criticised as being destructive, time consuming, and requiring specialist instrument training. Advances in the field of multispectral imaging (MSI) and hyperspectral imaging (HSI) have facilitated the development of compact imaging platforms with the capability to rapidly differentiate a range of materials (inclusive of grains and seeds) based on surface colour, texture and chemical composition. This preliminary investigation evaluated the applicability of spectral imaging for identification and quantitation of durum wheat grain samples in relation to pasta authenticity. MSI and HSI were capable of rapidly distinguishing between durum wheat and adulterant common wheat cultivars and assigning percentage adulteration levels characterised by low biases and good repeatability estimates. The results demonstrated the potential for spectral imaging based seed/grain adulteration testing to augment existing standard molecular approaches for food authenticity testing.展开更多
Despite the widespread use of malaria rapid diagnostic test(RDT)in clinical practice,there are a lot of challenges.We conducted a secondary analysis of 129 malaria RDT data from rounds 5–8 of the World Health Organiz...Despite the widespread use of malaria rapid diagnostic test(RDT)in clinical practice,there are a lot of challenges.We conducted a secondary analysis of 129 malaria RDT data from rounds 5–8 of the World Health Organization(WHO)product testing summary and discuss the causes of false-negative(FN)results with a focus on low parasite density,improper RDT storage,operation and interpretation,and Plasmodium falciparum with a pfhrp2/3 gene deletion.The results demonstrated that the malaria RDTs currently commercially available might cause FN results in practice.展开更多
To identify a cost-efficient altemative antibody testing strategy for screening and confirmation of HIV infection by rapid simple tests (RSTs) and enzyme-linked immunosorbent assays (ELISAs). Methods Four RSTs (R...To identify a cost-efficient altemative antibody testing strategy for screening and confirmation of HIV infection by rapid simple tests (RSTs) and enzyme-linked immunosorbent assays (ELISAs). Methods Four RSTs (RST1, RST2, RST3, and RST4 ) and five ELISAs (ELISA1, ELISA2, ELISA3, ELISA4, and ELISA5) were evaluated in two phases by using banked and serum specimens prospectively collected at regional hospitals and voluntary counseling and testing (VCT) centers in Beijing. A total of 200 banked serum specimens were included in the first phase, including 62 HIV-positive, 127 HIV-negative and 11 indeterminate specimens. All specimens were tested by four RSTs and five ELISAs respectively. The second phase involved prospective testing of 389 routine specimens, including 92 HIV-positive, 287 HIV-negative, and 10 indeterminate specimens. All the specimens were tested by two RSTs (RST2 and RST4) and three ELISAs (ELISA1, ELISA3, and ELISA4), which were selected for their respective excellent sensitivity and/or specificity. Westem blot (WB) was used as a gold standard for confirming the reactivity of all the specimens. Results Sensitivity, specificity, and efficacy were calculated for each assay in two phases. In the first phase, four assays (ELISA4, RST2, RST3, and RST4) had a specificity of 100%. For the determination of efficacy, ELISA4, RST2, and RST4 were selected in the second phase. ELISA1 and ELISA3 which have a sensitivity of 95.9% and 93.2% respectively also entered this phase. In the second phase, all the five assays (ELISA1, ELISA3, ELISA4, RST2, and RST4) had a sensitivity and specifity of over 90%. ELISA1 had a sensitivity of 99% and ELISA4 a specificity of 99%. Conclusion The sensitivity ELISA1 and the specificit of ELISA4 are comparable to ELISA/WB standard strategy. Application of this alternative testing strategy provides a cost-effective method for determining HIV prevalence in Beijing.展开更多
Introduction Difficulties in accessing the screening test for viral hepatitis B in maternity wards could be a factor in underestimating the prevalence of anti-HBV antibodies. The rapid diagnostic orientation test (RDO...Introduction Difficulties in accessing the screening test for viral hepatitis B in maternity wards could be a factor in underestimating the prevalence of anti-HBV antibodies. The rapid diagnostic orientation test (RDOT) could improve seroprevalence and obstetrical prognosis. The aim of this study was to use the rapid diagnostic orientation test (RDOT) to determine the seroprevalence of HBs antigen carriage in pregnant women while highlighting the associated factors. Methods This was a cross-sectional and descriptive study that took place from October to December 2020 (three months) in three (03) reference maternities in western Benin (Mono). Consenting pregnant women received in prenatal consultation had been screened by RDOT. Positive cases were confirmed by ELISA test. The follow-up of these cases made it possible to establish the obstetrical prognosis. Results Of 201 women studied, 11 (5.5%) were positive for RDOT HBV and confirmed by the ELISA test. The factors associated with HBsAg carriage during pregnancy were multiple sexual partnerships (p = 0.01), female circumcision (p = 0.0001), and ignorance of prior HBV serological status (p = 0.0001). No influence of hepatitis B on pregnancy was noted. Conclusion The seroprevalence of hepatitis B in pregnancy was intermediate in the reference maternities of western Benin. The associated factors were multiple sexual partnerships, female circumcision and unawareness of prior HBV status. Free RDOT in maternity wards would improve early detection and management of viral hepatitis B in pregnancy.展开更多
Extraction of AchE, relationship between substrate and enzyme concentration, and inhibition effects of the agrochemicals to AchE are discussed in this paper. Through the re-search, the proper AchE concentration for hy...Extraction of AchE, relationship between substrate and enzyme concentration, and inhibition effects of the agrochemicals to AchE are discussed in this paper. Through the re-search, the proper AchE concentration for hydrolysis of 1 ml 1mmol/L substrate and I50 val-ues of the agrochemicals to AchE are decided. It is proved that Asch-DTNB method is a rapid test tool for agrochemical residues in fruits and vegetables.A rapid test card has been developed with sensitivity of 0.05mg/L.展开更多
Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult p...Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult patients with suspected scrub typhus who visited a tertiary care hospital in the Republic of Korea from September to December from 2019 to 2021.The included patients had an acute fever and at least one of the following ten secondary findings:myalgia,skin rash,eschar,headache,thrombocytopenia,increased liver enzyme levels,lymphadenopathy,hepatomegaly,splenomegaly,and pleural effusion.The diagnoses were grouped as scrub typhus or other diseases by two infectious disease physicians.Results:Among 136 patients who met the eligibility criteria,109 had scrub typhus and 27 had different diseases.Single and paired total antibodies using immunofluorescence assay(IFA),and total antibodies using immunochromatography-based rapid diagnostic testing(ICT)were measured in 98%,22%,and 75%of all patients,respectively.Confirmation using paired samples for scrub typhus was established at a median of 11[interquartile range(IQR)10-16]days following the first visit.Among the 82 admitted patients,the median admission time was 9(IQR 7-13)days.According to IFA,58(55%)patients with scrub typhus had total immunoglobulin titers≥1:320,while 23(85%)patients with other disease had titers<1:320.Positive ICT results were observed in 64(74%)patients with scrub typhus and 10(67%)patients with other diseases showed negative ICT results.Conclusions:Serological testing for scrub typhus is currently insufficient for decision-making in clinical practice.展开更多
1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is...1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is important to evaluate their performances before use. We tested a rapid antigen detection of SARS-CoV-2, based on the immunochromatography (Boson Biotech SARS-CoV-2 Ag Test (Xiamen Boson Biotech Co., Ltd., China)) and the results were compared with the real time reverse transcriptase-Polymerase chain reaction (RT-PCR) (Gold standard) results;2) Methods: From November 2021 to December 2021, samples were collected from symptomatic patients and asymptomatic individuals referred for testing in a hospital during the second pandemic wave in Gabon. All these participants attending “CTA Angondjé”, a field hospital set up as part of the management of COVID-19 in Gabon. Two nasopharyngeal swabs were collected in all the patients, one for Ag test and the other for RT-PCR;3) Results: A total of 300 samples were collected from 189 symptomatic and 111 asymptomatic individuals. The sensitivity and specificity of the antigen test were 82.5% [95%CI 73.8 - 89.3] and 97.9 % [95%CI 92.2 - 98.2] respectively, and the diagnostic accuracy was 84.4% (95% CI: 79.8 - 88.3%). The antigen test was more likely to be positive for samples with RT-PCR Ct values ≤ 32, with a sensitivity of 89.8%;4) Conclusions: The Boson Biotech SARS-CoV-2 Ag Test has good sensitivity and can detect SARS-CoV-2 infection, especially among symptomatic individuals with low viral load. This test could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and curb viral transmission.展开更多
BACKGROUND A reliable test is essential for diagnosing Helicobacter pylori(H.pylori)infection,and crucial for managing H.pylori-related diseases.Serving as an excellent method for detecting H.pylori infection,histolog...BACKGROUND A reliable test is essential for diagnosing Helicobacter pylori(H.pylori)infection,and crucial for managing H.pylori-related diseases.Serving as an excellent method for detecting H.pylori infection,histologic examination is a test that clinicians heavily rely on,especially when complemented with immunohistochemistry(IHC).Additionally,other diagnostic tests for H.pylori,such as the rapid urease test(CLO test)and stool antigen test(SA),are also highly sensitive and specific.Typically,the results of histology and other tests align with each other.However,on rare occasions,discrepancy between histopathology and other H.pylori diagnostic tests occurs.AIM To investigate the discordance between histology and other H.pylori tests,the underlying causes,and the impact on clinical management.METHODS Pathology reports of gastric biopsies were retrieved spanning August 2013 and July 2018.Reports were included in the study only if there were other H.pylori tests within seven days of the biopsy.These additional tests include CLO test,SA,and H.pylori culture.Concordance between histopathology and other tests was determined based on the consistency of results.In instances where histology results were negative while other tests were positive,the slides were retrieved for re-assessment,and the clinical chart was reviewed.RESULTS Of 1396 pathology reports were identified,each accompanied by one additional H.pylori test.The concordance rates in detecting H.pylori infection between biopsy and other tests did not exhibit significant differences based on the number of biopsy fragments.117 discrepant cases were identified.Only 20 cases(9 with CLO test and 11 with SA)had negative biopsy but positive results in other tests.Four cases initially stained with Warthin-Starry turned out to be positive for H.pylori with subsequent IHC staining.Among the remaining 16 true discrepant cases,10 patients were on proton pump inhibitors before the biopsy and/or other tests.Most patients underwent treatment,except for two who were untreated,and two patients who were lost to follow-up.CONCLUSION There are rare discrepant cases with negative biopsy but positive in SA or CLO test.Various factors may contribute to this inconsistency.Most patients in such cases had undergone treatment.展开更多
Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determi...Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determine the prevalence of HIV, HCV and HBV co-infections in pregnant women at Bangui Community University Hospital and the cost of screening. Methods: A cross-sectional study involving consenting pregnant women who came for antenatal care was performed. HIV, HCV antibodies and HBV antigens were detected using Exacto Triplex<sup>?</sup> HIV/HCV/HBsAg rapid test, cross-validated by ELISA tests. Sociodemographic and professional data, the modes of transmission and prevention of HIV and both hepatitis viruses were collected in a standard sheet and analyzed using the Epi-Info software version 7. Results: Pregnant women aged 15 to 24 were the most affected (45.3%);high school girls (46.0%), and pregnant women living in cohabitation (65.3%) were the most represented. Twenty-five (16.7%) worked in the formal sector, 12.7% were unemployed housewives and the remainder in the informal sector. The prevalence of HIV, HBV, and HCV viruses was 11.8%, 21.9% and 22.2%, respectively. The prevalence of co-infections was 8.6% for HIV-HBV, 10.2% for HIV-HCV, 14.7% for HBV-HCV and 6.5% for HIV-HBV-HCV. All positive results and 10% of negative results by the rapid test were confirmed by ELISA tests. The serology of the three viruses costs 39,000 FCFA (60 Euros) by ELISA compared to 10,000 FCFA (15.00 Euros) with Exacto Triplex<sup>?</sup> HIV/HCV/AgHBs (BioSynex, Strasbourg, France). Conclusion: The low level of education and awareness of hepatitis are barriers to development and indicate the importance of improving the literacy rate of women in the Central African Republic (CAR). Likewise, the high prevalence of the three viruses shows the need for the urgent establishment of a national program to combat viral hepatitis in the CAR.展开更多
AIM:To evaluate the influence of multiple samplings during esophagogastr oduodenoscopy(EGD) on the accuracy of the rapid urease test,and the validity of newly developed rapid urease tests,HelicotecUT plus test and Hel...AIM:To evaluate the influence of multiple samplings during esophagogastr oduodenoscopy(EGD) on the accuracy of the rapid urease test,and the validity of newly developed rapid urease tests,HelicotecUT plus test and HelicotecUT test,CLO test and ProntoDry test.METHODS:A total of 355 patients undergoing EGD for dyspepsia were included.Their Helicobacter pylori(H.pylori) treatment status was either nave or eradicated.Six biopsy specimens from antrum and gastric body,respectively,were obtained during EGD.Single antral specimens and dual(antrum+body) specimens were compared.Infection status of H.pylori was evaluated by three different tests:culture,histology,and four different commercially available rapid urease tests(RUTs)-including the newly developed HelicotecUT plus test and HelicotecUT test,and established CLO test and ProntoDry test.H.pylori status was defined as positive when the culture was positive or if there were concordant positive results among histology,CLO test and ProntoDry test.RESULTS:When dual specimens were applied,sensitivity was enhanced and RUT reaction time was signif icantly reduced,regardless of their treatment status.Thirty minutes were enough to achieve an agreeable positive rate in all the RUTs.Both newly developed RUTs showed comparable sensitivity,specif icity and accuracy to the established RUTs,regardless of patient treatment status,RUT reaction duration,and EGD biopsy sites.CONCLUSION:Combination of antrum and body biopsy specimens greatly enhances the sensitivity of rapid urease test and reduces the reaction duration to 30 min.展开更多
The study discussed the rapid method to test and predict the longevity of controlled release fertilizers (CRFs) coated by water soluble resin by using the short-term leaching under higher temperature. Pure water dis...The study discussed the rapid method to test and predict the longevity of controlled release fertilizers (CRFs) coated by water soluble resin by using the short-term leaching under higher temperature. Pure water dissolving incubation and higher temperature leaching were used to study the patterns of the nutrient release of the CRFs. The correlation analysis between the days at 25℃ and the hours at 80℃ of Trincote 1 and Trincote 2 for the same cumulative release rates were conducted. Patterns of cumulative nutrient release curve followed one factor quadratic regression equation at each given temperatures, and each of relative coefficient was bigger than 0.995. As the temperature increased, nutrients release of the CRFs increased. The longevity of resin coated CRFs were predicted by use of both the cumulative nutrients release equation at 80℃ and the regression equation of release time needed for the same cumulative release rates between 25 and 80℃. There were only 0.3-6.9% relative errors between the tested longevity and predicted one. In conclusion, the longevity of resin coated CRFs could be predicted more quickly and precisely by use of the higher temperature short-term leaching method than that of the traditional differential release rate. The longevity of resin coated CRF could be rapidly and precisely predicted in a few hours by application of the higher temperature shortterm leaching method.展开更多
The World Health Organization (WHO) standard assay for determining levels of the rabies virus neutralization antibody (RVNA) is the rapid fluorescent focus inhibition test (RFFIT), which is used to evaluate the immuni...The World Health Organization (WHO) standard assay for determining levels of the rabies virus neutralization antibody (RVNA) is the rapid fluorescent focus inhibition test (RFFIT), which is used to evaluate the immunity effect after vaccination against rabies. For RFFIT, CVS-11 was used as the challenge virus, BSR cells as the adapted cells, and WHO rabies immunoglobulin (WHO STD) as the reference serum in this study. With reference to WHO and Pasteur RFFIT procedures, a micro-RFFIT procedure adapted to our laboratory was produced, and its specificity and reproducibility were tested. We tested levels of RVNA in human serum samples after immunization with different human rabies vaccines (domestic purified Vero cell rabies vaccine (PVRV) and imported purified chick embryo cell vaccine (PCECV)) using different regimens (Zagreb regimen and Essen regimen). We analyzed the levels of RVNA, and compared the immune efficacy of domestic PVRV and imported PCECV using different immunization regimens. The results showed that the immune efficacy of domestic PVRV using the Zagreb regimen was as good as that of the imported PCECV, but virus antibodies were generated more rapidly with the Zagreb regimen than with the Essen regimen. The RFFIT procedure established in our laboratory will enhance the comprehensive detection ability of institutions involved in rabies surveillance in China.展开更多
Presently the gold standard diagnostic technique for rabies is the direct immunofluorescence assay (dFA) which is very expensive and requires a high level of expertise. There is a need for more economical and user f...Presently the gold standard diagnostic technique for rabies is the direct immunofluorescence assay (dFA) which is very expensive and requires a high level of expertise. There is a need for more economical and user friendly tests, particularly for use in developing countries. We have established one such test called the direct rapid immunohistochemical test (dRIT) for diagnosis of rabies using brain tissue. The test is based on capture of rabies nucleoprotein (N) antigen in brain smears using a cocktail of biotinylated monoclonal antibodies specific for the N protein and color development by streptavidin peroxidase-amino ethyl carbazole and counter staining with haematoxollin. The test was done in parallel with standard FAT dFA using 400 brain samples from different animals and humans. The rabies virus N protein appears under fight microscope as reddish brown particles against a light blue background. There was 100 % correlation between the results obtained by the two tests. Also, interpretation of results by dRIT was easier and only required a light microscope. To conclude, this newly developed dRIT technique promises to be a simple, cost effective diagnostic tool for rabies and will have applicability in field conditions prevalent in developing countries.展开更多
BACKGROUND Helicobacter pylori(H.pylori)is a spiral-shaped bacterium responsible for the development of chronic gastritis,gastric ulcer,gastric cancer(GC),and MALTlymphoma of the stomach.H.pylori can be present in the...BACKGROUND Helicobacter pylori(H.pylori)is a spiral-shaped bacterium responsible for the development of chronic gastritis,gastric ulcer,gastric cancer(GC),and MALTlymphoma of the stomach.H.pylori can be present in the gastric mucosa(GM)in both spiral and coccoid forms.However,it is not known whether the severity of GM contamination by various vegetative forms of H.pylori is associated with clinical and morphological characteristics and long-term results of GC treatment.AIM To establish the features of H.pylori infection in patients with GC and their correlations with clinical and morphological characteristics of diseases and long-term results of treatment.METHODS Of 109 patients with GC were included in a prospective cohort study.H.pylori in the GM and tumor was determined by rapid urease test and by immunohistochemically using the antibody to H.pylori.The results obtained were compared with the clinical and morphological characteristics and prognosis of GC.Statistical analysis was performed using the Statistica 10.0 software.RESULTS H.pylori was detected in the adjacent to the tumor GM in 84.5%of cases,of which a high degree of contamination was noted in 50.4%of the samples.Coccoid forms of H.pylori were detected in 93.4%of infected patients,and only coccoid-in 68.9%.It was found that a high degree of GM contamination by the coccoid forms of H.pylori was observed significantly more often in diffuse type of GC(P=0.024),in poorly differentiated GC(P=0.011),in stage T3-4(P=0.04)and in N1(P=0.011).In cases of moderate and marked concentrations of H.pylori in GM,a decrease in 10-year relapse free and overall survival from 55.6%to 26.3%was observed(P=0.02 and P=0.07,respectively).The relationship between the severity of the GM contamination by the spiral-shaped forms of H.pylori and the clinical and morphological characteristics and prognosis of GC was not revealed.CONCLUSION The data obtained indicates that H.pylori may be associated not only with induction but also with the progression of GC.展开更多
AIM: To investigate clarithromycin resistance positions 2142, 2143 and 2144 of the 23 Sr RNA gene in Helicobacter pylori(H. pylori) by nested-allele specific primer-polymerase chain reaction(nested-ASP-PCR).METHODS: T...AIM: To investigate clarithromycin resistance positions 2142, 2143 and 2144 of the 23 Sr RNA gene in Helicobacter pylori(H. pylori) by nested-allele specific primer-polymerase chain reaction(nested-ASP-PCR).METHODS: The gastric tissue and saliva samples from 99 patients with positive results of the rapid urease test(RUT) were collected. The nested-ASP-PCR method was carried out with the external primers and inner allele-specific primers corresponding to the reference strain and clinical strains. Thirty gastric tissue and saliva samples were tested to determine the sensitivity of nested-ASP-PCR and ASP-PCR methods. Then, clarithromycin resistance was detected for 99 clinical samples by using different methods, including nestedASP-PCR, bacterial culture and disk diffusion. RESULTS: The nested-ASP-PCR method was successfully established to test the resistance mutation points 2142, 2143 and 2144 of the 23 SrR NA gene of H. pylori. Among 30 samples of gastric tissue and saliva, the H. pylori detection rate of nested-ASP-PCR was 90% and 83.33%, while the detection rate of ASP-PCR was just 63% and 56.67%. Especially in the saliva samples, nested-ASP-PCR showed much higher sensitivity in H. pylori detection and resistance mutation rates thanASP-PCR. In the 99 RUT-positive gastric tissue and saliva samples, the H. pylori-positive detection rate by nested-ASP-PCR was 87(87.88%) and 67(67.68%), in which there were 30 wild-type and 57 mutated strains in gastric tissue and 22 wild-type and 45 mutated strains in saliva. Genotype analysis showed that three-points mixed mutations were quite common, but different resistant strains were present in gastric mucosa and saliva. Compared to the high sensitivity shown by nested-ASP-PCR, the positive detection of bacterial culture with gastric tissue samples was 50 cases, in which only 26 drug-resistant strains were found through analyzing minimum inhibitory zone of clarithromycin. CONCLUSION: The nested-ASP-PCR assay showed higher detection sensitivity than ASP-PCR and drug sensitivity testing, which could be performed to evaluate clarithromycin resistance of H. pylori.展开更多
AIM: To assess the value of a new test for the diagnosis of Helicobacter pylori (H. pylori) infection, Rapirun<sup>®</sup>H. pylori Antibody Stick (Rapirun<sup>®</sup> S...AIM: To assess the value of a new test for the diagnosis of Helicobacter pylori (H. pylori) infection, Rapirun<sup>®</sup>H. pylori Antibody Stick (Rapirun<sup>®</sup> Stick), in a Vietnamese population.展开更多
Combined with the tire dynamics theoretical model,a rapid test method to obtain tire lateral and longitudinal both steady-state and transient characteristics only based on the tire quasi-steady-state test results is p...Combined with the tire dynamics theoretical model,a rapid test method to obtain tire lateral and longitudinal both steady-state and transient characteristics only based on the tire quasi-steady-state test results is proposed.For steady state data extraction,the test time of the rapid test method is half that of the conventional test method.For transient tire characteristics the rapid test method omits the traditional tire test totally.At the mean time the accuracy of the two method is much closed.The rapid test method is explained theoretically and the test process is designed.The key parameters of tire are extracted and the comparison is made between rapid test and traditional test method.The result show that the identification accuracy based on the rapid test method is almost equal to the accuracy of the conventional one.Then,the heat generated during the rapid test method and that generated during the conventional test are calculated separately.The comparison shows that the heat generated during the rapid test is much smaller than the heat generated during the conventional test process.This benefits to the reduction of tire wear and the consistency of test results.Finally,it can be concluded that the fast test method can efficiently,accurately and energy-efficiently measure the steady-state and transient characteristics of the tire.展开更多
文摘BACKGROUND At the end of December 2019,the world faced severe acute respiratory syndrome-coronavirus 2(SARS-CoV-2),which led to the outbreak of coronavirus disease 2019(COVID-19),associated with respiratory issues.This virus has shown significant challenges,especially for senior citizens,patients with other underlying illnesses,or those with a sedentary lifestyle.Serological tests conducted early on have helped identify how the virus is transmitted and how to curb its spread.The study hypothesis was that the rapid serological test for SARS-CoV-2 antibodies could indicate the immunoreactive profile during the COVID-19 pandemic in a university population.AIM To conduct active surveillance for serological expression of anti-SARS-CoV-2 antibodies in individuals within a university setting during the COVID-19 pandemic.METHODS This sectional study by convenience sampling was conducted in a large university in Niteroi-RJ,Brazil,from March 2021 to July 2021.The study population consisted of students,faculty,and administrative staff employed by the university.A total of 3433 faculty members,60703 students,and 3812 administrative staff were invited to participate.Data were gathered through rapid serological tests to detect immunoglobulin(Ig)M and IgG against SARS-CoV-2.Theχ²or Fisher's exact test was used to conduct statistical analysis.A 0.20 significance level was adopted for variable selection in a multiple logistic regression model to evaluate associations.RESULTS A total of 1648 individuals were enrolled in the study.The proportion of COVID-19 positivity was 164/1648(9.8%).The adjusted logistic model indicate a positive association between the expression of IgM or IgG and age[odds ratio(OR)=1.16,95%CI:1.02-1.31](P<0.0024),individuals who had been in contact with a COVID-19-positive case(OR=3.49,95%CI:2.34-5.37)(P<0.001),those who had received the COVID-19 vaccine(OR=2.33,95%CI:1.61-3.35)(P<0.001)and social isolation(OR=0.59,95%CI:0.41-0.84)(P<0.004).The likelihood of showing a positive result increased by 16%with every ten-year increment.Conversely,adherence to social distancing measures decreased the likelihood by 41%.CONCLUSION These findings evidenced that the population became more exposed to the virus as individuals discontinued social distancing practices,thereby increasing the risk of infection for themselves.
文摘Food safety is one of the major concerns in every country regardless of the economic and social development. The frequent occurrence of food scandals in the world has led the Chinese government to implement several strategies to fortify the food supply system to a high food safety standard. This relies heavily on laboratory testing services but conventional methods for detection of food contaminants and toxicants are limited by sophisticated sample preparation procedures, long analysis time, large instruments and professional personnel to meet the increasing demands. In this review, we have incorporated most of the current and potential rapid detection methods for many notorious food contaminants and toxicants including microbial agents, toxic ions, pesticides, veterinary drugs and preservatives, as well as detection of genetically modified food genes and adulterated edible oil. Development of rapid, accurate, easy-to-use and affordable testing methods could urge food handlers and the public to actively screen for food contaminants and toxicants instead of passively relying on monitoring by the government examination facility. This review also provides several recommendations including how to encourage the public to engage in the food safety management system and provide optimal education and financial assistance that may improve the current Chinese food safety control system.
基金Grant from National Institute of Infectious Diseases(NIID)National Department Public Benefit Research Foundation (201103032)
文摘The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, Sl, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation
文摘Authentication of pasta is currently determined using molecular biology-based techniques focusing on DNA as the target analyte. Whilst proven to be effective, these approaches can be criticised as being destructive, time consuming, and requiring specialist instrument training. Advances in the field of multispectral imaging (MSI) and hyperspectral imaging (HSI) have facilitated the development of compact imaging platforms with the capability to rapidly differentiate a range of materials (inclusive of grains and seeds) based on surface colour, texture and chemical composition. This preliminary investigation evaluated the applicability of spectral imaging for identification and quantitation of durum wheat grain samples in relation to pasta authenticity. MSI and HSI were capable of rapidly distinguishing between durum wheat and adulterant common wheat cultivars and assigning percentage adulteration levels characterised by low biases and good repeatability estimates. The results demonstrated the potential for spectral imaging based seed/grain adulteration testing to augment existing standard molecular approaches for food authenticity testing.
基金supported by the National Grand Program on Key Infectious Disease(2018ZX10103002-001-007)the Biosafety Special Program(19SWAQ 13)。
文摘Despite the widespread use of malaria rapid diagnostic test(RDT)in clinical practice,there are a lot of challenges.We conducted a secondary analysis of 129 malaria RDT data from rounds 5–8 of the World Health Organization(WHO)product testing summary and discuss the causes of false-negative(FN)results with a focus on low parasite density,improper RDT storage,operation and interpretation,and Plasmodium falciparum with a pfhrp2/3 gene deletion.The results demonstrated that the malaria RDTs currently commercially available might cause FN results in practice.
基金As part of the AIDS Prevention Applied Research and Program of the Ministry of Health (WA2003-17)the present study is supportedby the Department of Reference,National Center for AIDS Control and Prevention,Chinese Center for Disease Control and Prevention.
文摘To identify a cost-efficient altemative antibody testing strategy for screening and confirmation of HIV infection by rapid simple tests (RSTs) and enzyme-linked immunosorbent assays (ELISAs). Methods Four RSTs (RST1, RST2, RST3, and RST4 ) and five ELISAs (ELISA1, ELISA2, ELISA3, ELISA4, and ELISA5) were evaluated in two phases by using banked and serum specimens prospectively collected at regional hospitals and voluntary counseling and testing (VCT) centers in Beijing. A total of 200 banked serum specimens were included in the first phase, including 62 HIV-positive, 127 HIV-negative and 11 indeterminate specimens. All specimens were tested by four RSTs and five ELISAs respectively. The second phase involved prospective testing of 389 routine specimens, including 92 HIV-positive, 287 HIV-negative, and 10 indeterminate specimens. All the specimens were tested by two RSTs (RST2 and RST4) and three ELISAs (ELISA1, ELISA3, and ELISA4), which were selected for their respective excellent sensitivity and/or specificity. Westem blot (WB) was used as a gold standard for confirming the reactivity of all the specimens. Results Sensitivity, specificity, and efficacy were calculated for each assay in two phases. In the first phase, four assays (ELISA4, RST2, RST3, and RST4) had a specificity of 100%. For the determination of efficacy, ELISA4, RST2, and RST4 were selected in the second phase. ELISA1 and ELISA3 which have a sensitivity of 95.9% and 93.2% respectively also entered this phase. In the second phase, all the five assays (ELISA1, ELISA3, ELISA4, RST2, and RST4) had a sensitivity and specifity of over 90%. ELISA1 had a sensitivity of 99% and ELISA4 a specificity of 99%. Conclusion The sensitivity ELISA1 and the specificit of ELISA4 are comparable to ELISA/WB standard strategy. Application of this alternative testing strategy provides a cost-effective method for determining HIV prevalence in Beijing.
文摘Introduction Difficulties in accessing the screening test for viral hepatitis B in maternity wards could be a factor in underestimating the prevalence of anti-HBV antibodies. The rapid diagnostic orientation test (RDOT) could improve seroprevalence and obstetrical prognosis. The aim of this study was to use the rapid diagnostic orientation test (RDOT) to determine the seroprevalence of HBs antigen carriage in pregnant women while highlighting the associated factors. Methods This was a cross-sectional and descriptive study that took place from October to December 2020 (three months) in three (03) reference maternities in western Benin (Mono). Consenting pregnant women received in prenatal consultation had been screened by RDOT. Positive cases were confirmed by ELISA test. The follow-up of these cases made it possible to establish the obstetrical prognosis. Results Of 201 women studied, 11 (5.5%) were positive for RDOT HBV and confirmed by the ELISA test. The factors associated with HBsAg carriage during pregnancy were multiple sexual partnerships (p = 0.01), female circumcision (p = 0.0001), and ignorance of prior HBV serological status (p = 0.0001). No influence of hepatitis B on pregnancy was noted. Conclusion The seroprevalence of hepatitis B in pregnancy was intermediate in the reference maternities of western Benin. The associated factors were multiple sexual partnerships, female circumcision and unawareness of prior HBV status. Free RDOT in maternity wards would improve early detection and management of viral hepatitis B in pregnancy.
文摘Extraction of AchE, relationship between substrate and enzyme concentration, and inhibition effects of the agrochemicals to AchE are discussed in this paper. Through the re-search, the proper AchE concentration for hydrolysis of 1 ml 1mmol/L substrate and I50 val-ues of the agrochemicals to AchE are decided. It is proved that Asch-DTNB method is a rapid test tool for agrochemical residues in fruits and vegetables.A rapid test card has been developed with sensitivity of 0.05mg/L.
基金the Korea Health Technology R&D Project through the Korea Health Industry Development Institute(KHIDI),funded by the Ministry of Health&Welfare,Republic of Korea(grant no.HI22C0306).
文摘Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult patients with suspected scrub typhus who visited a tertiary care hospital in the Republic of Korea from September to December from 2019 to 2021.The included patients had an acute fever and at least one of the following ten secondary findings:myalgia,skin rash,eschar,headache,thrombocytopenia,increased liver enzyme levels,lymphadenopathy,hepatomegaly,splenomegaly,and pleural effusion.The diagnoses were grouped as scrub typhus or other diseases by two infectious disease physicians.Results:Among 136 patients who met the eligibility criteria,109 had scrub typhus and 27 had different diseases.Single and paired total antibodies using immunofluorescence assay(IFA),and total antibodies using immunochromatography-based rapid diagnostic testing(ICT)were measured in 98%,22%,and 75%of all patients,respectively.Confirmation using paired samples for scrub typhus was established at a median of 11[interquartile range(IQR)10-16]days following the first visit.Among the 82 admitted patients,the median admission time was 9(IQR 7-13)days.According to IFA,58(55%)patients with scrub typhus had total immunoglobulin titers≥1:320,while 23(85%)patients with other disease had titers<1:320.Positive ICT results were observed in 64(74%)patients with scrub typhus and 10(67%)patients with other diseases showed negative ICT results.Conclusions:Serological testing for scrub typhus is currently insufficient for decision-making in clinical practice.
文摘1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is important to evaluate their performances before use. We tested a rapid antigen detection of SARS-CoV-2, based on the immunochromatography (Boson Biotech SARS-CoV-2 Ag Test (Xiamen Boson Biotech Co., Ltd., China)) and the results were compared with the real time reverse transcriptase-Polymerase chain reaction (RT-PCR) (Gold standard) results;2) Methods: From November 2021 to December 2021, samples were collected from symptomatic patients and asymptomatic individuals referred for testing in a hospital during the second pandemic wave in Gabon. All these participants attending “CTA Angondjé”, a field hospital set up as part of the management of COVID-19 in Gabon. Two nasopharyngeal swabs were collected in all the patients, one for Ag test and the other for RT-PCR;3) Results: A total of 300 samples were collected from 189 symptomatic and 111 asymptomatic individuals. The sensitivity and specificity of the antigen test were 82.5% [95%CI 73.8 - 89.3] and 97.9 % [95%CI 92.2 - 98.2] respectively, and the diagnostic accuracy was 84.4% (95% CI: 79.8 - 88.3%). The antigen test was more likely to be positive for samples with RT-PCR Ct values ≤ 32, with a sensitivity of 89.8%;4) Conclusions: The Boson Biotech SARS-CoV-2 Ag Test has good sensitivity and can detect SARS-CoV-2 infection, especially among symptomatic individuals with low viral load. This test could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and curb viral transmission.
文摘BACKGROUND A reliable test is essential for diagnosing Helicobacter pylori(H.pylori)infection,and crucial for managing H.pylori-related diseases.Serving as an excellent method for detecting H.pylori infection,histologic examination is a test that clinicians heavily rely on,especially when complemented with immunohistochemistry(IHC).Additionally,other diagnostic tests for H.pylori,such as the rapid urease test(CLO test)and stool antigen test(SA),are also highly sensitive and specific.Typically,the results of histology and other tests align with each other.However,on rare occasions,discrepancy between histopathology and other H.pylori diagnostic tests occurs.AIM To investigate the discordance between histology and other H.pylori tests,the underlying causes,and the impact on clinical management.METHODS Pathology reports of gastric biopsies were retrieved spanning August 2013 and July 2018.Reports were included in the study only if there were other H.pylori tests within seven days of the biopsy.These additional tests include CLO test,SA,and H.pylori culture.Concordance between histopathology and other tests was determined based on the consistency of results.In instances where histology results were negative while other tests were positive,the slides were retrieved for re-assessment,and the clinical chart was reviewed.RESULTS Of 1396 pathology reports were identified,each accompanied by one additional H.pylori test.The concordance rates in detecting H.pylori infection between biopsy and other tests did not exhibit significant differences based on the number of biopsy fragments.117 discrepant cases were identified.Only 20 cases(9 with CLO test and 11 with SA)had negative biopsy but positive results in other tests.Four cases initially stained with Warthin-Starry turned out to be positive for H.pylori with subsequent IHC staining.Among the remaining 16 true discrepant cases,10 patients were on proton pump inhibitors before the biopsy and/or other tests.Most patients underwent treatment,except for two who were untreated,and two patients who were lost to follow-up.CONCLUSION There are rare discrepant cases with negative biopsy but positive in SA or CLO test.Various factors may contribute to this inconsistency.Most patients in such cases had undergone treatment.
文摘Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determine the prevalence of HIV, HCV and HBV co-infections in pregnant women at Bangui Community University Hospital and the cost of screening. Methods: A cross-sectional study involving consenting pregnant women who came for antenatal care was performed. HIV, HCV antibodies and HBV antigens were detected using Exacto Triplex<sup>?</sup> HIV/HCV/HBsAg rapid test, cross-validated by ELISA tests. Sociodemographic and professional data, the modes of transmission and prevention of HIV and both hepatitis viruses were collected in a standard sheet and analyzed using the Epi-Info software version 7. Results: Pregnant women aged 15 to 24 were the most affected (45.3%);high school girls (46.0%), and pregnant women living in cohabitation (65.3%) were the most represented. Twenty-five (16.7%) worked in the formal sector, 12.7% were unemployed housewives and the remainder in the informal sector. The prevalence of HIV, HBV, and HCV viruses was 11.8%, 21.9% and 22.2%, respectively. The prevalence of co-infections was 8.6% for HIV-HBV, 10.2% for HIV-HCV, 14.7% for HBV-HCV and 6.5% for HIV-HBV-HCV. All positive results and 10% of negative results by the rapid test were confirmed by ELISA tests. The serology of the three viruses costs 39,000 FCFA (60 Euros) by ELISA compared to 10,000 FCFA (15.00 Euros) with Exacto Triplex<sup>?</sup> HIV/HCV/AgHBs (BioSynex, Strasbourg, France). Conclusion: The low level of education and awareness of hepatitis are barriers to development and indicate the importance of improving the literacy rate of women in the Central African Republic (CAR). Likewise, the high prevalence of the three viruses shows the need for the urgent establishment of a national program to combat viral hepatitis in the CAR.
基金Supported by A Grant from Kaohsiung Medical University Hospital (M094015, 94-KMUH-032, KMUH95-5D51)E-Da Hospital (EDAH-D-97(P)014A)+1 种基金Excellence for cancer research center grant, No DOH99-TD-C-111-002Department of Health, Executive Yuan, Taiwan
文摘AIM:To evaluate the influence of multiple samplings during esophagogastr oduodenoscopy(EGD) on the accuracy of the rapid urease test,and the validity of newly developed rapid urease tests,HelicotecUT plus test and HelicotecUT test,CLO test and ProntoDry test.METHODS:A total of 355 patients undergoing EGD for dyspepsia were included.Their Helicobacter pylori(H.pylori) treatment status was either nave or eradicated.Six biopsy specimens from antrum and gastric body,respectively,were obtained during EGD.Single antral specimens and dual(antrum+body) specimens were compared.Infection status of H.pylori was evaluated by three different tests:culture,histology,and four different commercially available rapid urease tests(RUTs)-including the newly developed HelicotecUT plus test and HelicotecUT test,and established CLO test and ProntoDry test.H.pylori status was defined as positive when the culture was positive or if there were concordant positive results among histology,CLO test and ProntoDry test.RESULTS:When dual specimens were applied,sensitivity was enhanced and RUT reaction time was signif icantly reduced,regardless of their treatment status.Thirty minutes were enough to achieve an agreeable positive rate in all the RUTs.Both newly developed RUTs showed comparable sensitivity,specif icity and accuracy to the established RUTs,regardless of patient treatment status,RUT reaction duration,and EGD biopsy sites.CONCLUSION:Combination of antrum and body biopsy specimens greatly enhances the sensitivity of rapid urease test and reduces the reaction duration to 30 min.
基金the National Key Technologies R&D Program during the 11th Five-Year Plan period of China (2006BAD10B02)the National Natural Science Foundation of China (39870433,30270769)
文摘The study discussed the rapid method to test and predict the longevity of controlled release fertilizers (CRFs) coated by water soluble resin by using the short-term leaching under higher temperature. Pure water dissolving incubation and higher temperature leaching were used to study the patterns of the nutrient release of the CRFs. The correlation analysis between the days at 25℃ and the hours at 80℃ of Trincote 1 and Trincote 2 for the same cumulative release rates were conducted. Patterns of cumulative nutrient release curve followed one factor quadratic regression equation at each given temperatures, and each of relative coefficient was bigger than 0.995. As the temperature increased, nutrients release of the CRFs increased. The longevity of resin coated CRFs were predicted by use of both the cumulative nutrients release equation at 80℃ and the regression equation of release time needed for the same cumulative release rates between 25 and 80℃. There were only 0.3-6.9% relative errors between the tested longevity and predicted one. In conclusion, the longevity of resin coated CRFs could be predicted more quickly and precisely by use of the higher temperature short-term leaching method than that of the traditional differential release rate. The longevity of resin coated CRF could be rapidly and precisely predicted in a few hours by application of the higher temperature shortterm leaching method.
基金National Department Public Benefit Research Foundation (201103032)
文摘The World Health Organization (WHO) standard assay for determining levels of the rabies virus neutralization antibody (RVNA) is the rapid fluorescent focus inhibition test (RFFIT), which is used to evaluate the immunity effect after vaccination against rabies. For RFFIT, CVS-11 was used as the challenge virus, BSR cells as the adapted cells, and WHO rabies immunoglobulin (WHO STD) as the reference serum in this study. With reference to WHO and Pasteur RFFIT procedures, a micro-RFFIT procedure adapted to our laboratory was produced, and its specificity and reproducibility were tested. We tested levels of RVNA in human serum samples after immunization with different human rabies vaccines (domestic purified Vero cell rabies vaccine (PVRV) and imported purified chick embryo cell vaccine (PCECV)) using different regimens (Zagreb regimen and Essen regimen). We analyzed the levels of RVNA, and compared the immune efficacy of domestic PVRV and imported PCECV using different immunization regimens. The results showed that the immune efficacy of domestic PVRV using the Zagreb regimen was as good as that of the imported PCECV, but virus antibodies were generated more rapidly with the Zagreb regimen than with the Essen regimen. The RFFIT procedure established in our laboratory will enhance the comprehensive detection ability of institutions involved in rabies surveillance in China.
文摘Presently the gold standard diagnostic technique for rabies is the direct immunofluorescence assay (dFA) which is very expensive and requires a high level of expertise. There is a need for more economical and user friendly tests, particularly for use in developing countries. We have established one such test called the direct rapid immunohistochemical test (dRIT) for diagnosis of rabies using brain tissue. The test is based on capture of rabies nucleoprotein (N) antigen in brain smears using a cocktail of biotinylated monoclonal antibodies specific for the N protein and color development by streptavidin peroxidase-amino ethyl carbazole and counter staining with haematoxollin. The test was done in parallel with standard FAT dFA using 400 brain samples from different animals and humans. The rabies virus N protein appears under fight microscope as reddish brown particles against a light blue background. There was 100 % correlation between the results obtained by the two tests. Also, interpretation of results by dRIT was easier and only required a light microscope. To conclude, this newly developed dRIT technique promises to be a simple, cost effective diagnostic tool for rabies and will have applicability in field conditions prevalent in developing countries.
文摘BACKGROUND Helicobacter pylori(H.pylori)is a spiral-shaped bacterium responsible for the development of chronic gastritis,gastric ulcer,gastric cancer(GC),and MALTlymphoma of the stomach.H.pylori can be present in the gastric mucosa(GM)in both spiral and coccoid forms.However,it is not known whether the severity of GM contamination by various vegetative forms of H.pylori is associated with clinical and morphological characteristics and long-term results of GC treatment.AIM To establish the features of H.pylori infection in patients with GC and their correlations with clinical and morphological characteristics of diseases and long-term results of treatment.METHODS Of 109 patients with GC were included in a prospective cohort study.H.pylori in the GM and tumor was determined by rapid urease test and by immunohistochemically using the antibody to H.pylori.The results obtained were compared with the clinical and morphological characteristics and prognosis of GC.Statistical analysis was performed using the Statistica 10.0 software.RESULTS H.pylori was detected in the adjacent to the tumor GM in 84.5%of cases,of which a high degree of contamination was noted in 50.4%of the samples.Coccoid forms of H.pylori were detected in 93.4%of infected patients,and only coccoid-in 68.9%.It was found that a high degree of GM contamination by the coccoid forms of H.pylori was observed significantly more often in diffuse type of GC(P=0.024),in poorly differentiated GC(P=0.011),in stage T3-4(P=0.04)and in N1(P=0.011).In cases of moderate and marked concentrations of H.pylori in GM,a decrease in 10-year relapse free and overall survival from 55.6%to 26.3%was observed(P=0.02 and P=0.07,respectively).The relationship between the severity of the GM contamination by the spiral-shaped forms of H.pylori and the clinical and morphological characteristics and prognosis of GC was not revealed.CONCLUSION The data obtained indicates that H.pylori may be associated not only with induction but also with the progression of GC.
基金the Hospital of Qixia in Nanjing for providing sufficient financial support for this study
文摘AIM: To investigate clarithromycin resistance positions 2142, 2143 and 2144 of the 23 Sr RNA gene in Helicobacter pylori(H. pylori) by nested-allele specific primer-polymerase chain reaction(nested-ASP-PCR).METHODS: The gastric tissue and saliva samples from 99 patients with positive results of the rapid urease test(RUT) were collected. The nested-ASP-PCR method was carried out with the external primers and inner allele-specific primers corresponding to the reference strain and clinical strains. Thirty gastric tissue and saliva samples were tested to determine the sensitivity of nested-ASP-PCR and ASP-PCR methods. Then, clarithromycin resistance was detected for 99 clinical samples by using different methods, including nestedASP-PCR, bacterial culture and disk diffusion. RESULTS: The nested-ASP-PCR method was successfully established to test the resistance mutation points 2142, 2143 and 2144 of the 23 SrR NA gene of H. pylori. Among 30 samples of gastric tissue and saliva, the H. pylori detection rate of nested-ASP-PCR was 90% and 83.33%, while the detection rate of ASP-PCR was just 63% and 56.67%. Especially in the saliva samples, nested-ASP-PCR showed much higher sensitivity in H. pylori detection and resistance mutation rates thanASP-PCR. In the 99 RUT-positive gastric tissue and saliva samples, the H. pylori-positive detection rate by nested-ASP-PCR was 87(87.88%) and 67(67.68%), in which there were 30 wild-type and 57 mutated strains in gastric tissue and 22 wild-type and 45 mutated strains in saliva. Genotype analysis showed that three-points mixed mutations were quite common, but different resistant strains were present in gastric mucosa and saliva. Compared to the high sensitivity shown by nested-ASP-PCR, the positive detection of bacterial culture with gastric tissue samples was 50 cases, in which only 26 drug-resistant strains were found through analyzing minimum inhibitory zone of clarithromycin. CONCLUSION: The nested-ASP-PCR assay showed higher detection sensitivity than ASP-PCR and drug sensitivity testing, which could be performed to evaluate clarithromycin resistance of H. pylori.
基金Supported by International Collaborative Research Grant of the Japanese Society of Gastrointestinal Cancer Screening
文摘AIM: To assess the value of a new test for the diagnosis of Helicobacter pylori (H. pylori) infection, Rapirun<sup>®</sup>H. pylori Antibody Stick (Rapirun<sup>®</sup> Stick), in a Vietnamese population.
基金Supported by National Natural Science Foundation of China(Grant No.51775224).
文摘Combined with the tire dynamics theoretical model,a rapid test method to obtain tire lateral and longitudinal both steady-state and transient characteristics only based on the tire quasi-steady-state test results is proposed.For steady state data extraction,the test time of the rapid test method is half that of the conventional test method.For transient tire characteristics the rapid test method omits the traditional tire test totally.At the mean time the accuracy of the two method is much closed.The rapid test method is explained theoretically and the test process is designed.The key parameters of tire are extracted and the comparison is made between rapid test and traditional test method.The result show that the identification accuracy based on the rapid test method is almost equal to the accuracy of the conventional one.Then,the heat generated during the rapid test method and that generated during the conventional test are calculated separately.The comparison shows that the heat generated during the rapid test is much smaller than the heat generated during the conventional test process.This benefits to the reduction of tire wear and the consistency of test results.Finally,it can be concluded that the fast test method can efficiently,accurately and energy-efficiently measure the steady-state and transient characteristics of the tire.