Chain length of closed circle DNA is equal. The same closed circle DNA's position corresponds to different recognition sequence, and the same recognition sequence corresponds to different foreign DNA segment, so clos...Chain length of closed circle DNA is equal. The same closed circle DNA's position corresponds to different recognition sequence, and the same recognition sequence corresponds to different foreign DNA segment, so closed circle DNA computing model is generalized. For change positive-weighted Hamilton circuit problem, closed circle DNA algorithm is put forward. First, three groups of DNA encoding are encoded for all arcs, and deck groups are designed for all vertices. All possible solutions are composed. Then, the feasible solutions are filtered out by using group detect experiment, and the optimization solutions are obtained by using group insert experiment and electrophoresis experiment. Finally, all optimization solutions are found by using detect experiment. Complexity of algorithm is concluded and validity of DNA algorithm is explained by an example. Three dominances of the closed circle DNA algorithm are analyzed, and characteristics and dominances of group delete experiment are discussed.展开更多
The aim of this research was determine the ma- ximum application uniformity of closed circuit trickle irrigation systems designs. Laboratory tests carried out for Two types of closed circuits: a) One manifold for late...The aim of this research was determine the ma- ximum application uniformity of closed circuit trickle irrigation systems designs. Laboratory tests carried out for Two types of closed circuits: a) One manifold for lateral lines or Closed circuits with One Manifold of Trikle Irrigation System (COMTIS);b) Closed circuits with Two Manifolds of Trikle Irrigation System (CTMTIS), and c) Traditional Trikle Irrigation System (TTIS) as a control. Three lengths of lateral lines were used, 40, 60, and 80 meters. PE tubes lateral lines: 16 mm diameter;30 cm emitters distance, and GR built-in emitters 4 lph when operating pressure 1 bar. Experiments were conducted at the Agric. Eng. Res. Inst., ARC, MALR, Egypt. With COMTIS the emitter flow rate was 4.07, 3.51, and 3.59 lph compared to 4.18, 3.72, and 3.71 lph with CTMTIS and 3.21, 2.6, and 2.16 lph with TTIS (lateral lengths 40, 60, and 80 meters respectively). Uniformity varied widely within individual lateral lengths and between circuit types. Under CTMTIS uniformity values were 97.74, 95.14, and 92.03 %;with COMTIS they were 95.73, 89.45, and 83.25 %;and with TTIS they were 88.27, 84.73, and 80.53 % (for lateral lengths 40, 60, 80 meters respectively). The greatest uniformity was observed under CTMTIS and COMTIS when using the shortest lateral length 40 meters, then lateral length 60 meters, while the lowest value was observed when using lateral length 80 meters this result depends on the physical and hydraulic characteristics of the emitter and lateral line. CTMTIS was more uniform than either COMTIS or TTIS. Friction losses were decreased with CTMTIS in the emitter laterals at lengths 40 meters compared to TTIS and COMTIS. Therefore, differences may be related to increased friction losses when using TDIS and COMDIS.展开更多
内蒙古巴彦淖尔地区某110 k V变电站主变压器由于恶劣的气象条件导致跳闸故障,造成主变压器三侧断路器跳开,差动保护和本体重瓦斯保护动作。事故发生后,采用油色谱分析、绕组变形及直流电阻测试、电容量变化率分析等多种方法判断主变压...内蒙古巴彦淖尔地区某110 k V变电站主变压器由于恶劣的气象条件导致跳闸故障,造成主变压器三侧断路器跳开,差动保护和本体重瓦斯保护动作。事故发生后,采用油色谱分析、绕组变形及直流电阻测试、电容量变化率分析等多种方法判断主变压器的受损部位、受损程度,经验证发现试验结论均一致。本文采用的几种方法可为今后其他变电站准确判断变压器受损部位及受损程度提供参考。展开更多
基金supported by the National Natural Science Foundation of China(60574041)the Natural ScienceFoundation of Hubei Province(2007ABA407).
文摘Chain length of closed circle DNA is equal. The same closed circle DNA's position corresponds to different recognition sequence, and the same recognition sequence corresponds to different foreign DNA segment, so closed circle DNA computing model is generalized. For change positive-weighted Hamilton circuit problem, closed circle DNA algorithm is put forward. First, three groups of DNA encoding are encoded for all arcs, and deck groups are designed for all vertices. All possible solutions are composed. Then, the feasible solutions are filtered out by using group detect experiment, and the optimization solutions are obtained by using group insert experiment and electrophoresis experiment. Finally, all optimization solutions are found by using detect experiment. Complexity of algorithm is concluded and validity of DNA algorithm is explained by an example. Three dominances of the closed circle DNA algorithm are analyzed, and characteristics and dominances of group delete experiment are discussed.
文摘The aim of this research was determine the ma- ximum application uniformity of closed circuit trickle irrigation systems designs. Laboratory tests carried out for Two types of closed circuits: a) One manifold for lateral lines or Closed circuits with One Manifold of Trikle Irrigation System (COMTIS);b) Closed circuits with Two Manifolds of Trikle Irrigation System (CTMTIS), and c) Traditional Trikle Irrigation System (TTIS) as a control. Three lengths of lateral lines were used, 40, 60, and 80 meters. PE tubes lateral lines: 16 mm diameter;30 cm emitters distance, and GR built-in emitters 4 lph when operating pressure 1 bar. Experiments were conducted at the Agric. Eng. Res. Inst., ARC, MALR, Egypt. With COMTIS the emitter flow rate was 4.07, 3.51, and 3.59 lph compared to 4.18, 3.72, and 3.71 lph with CTMTIS and 3.21, 2.6, and 2.16 lph with TTIS (lateral lengths 40, 60, and 80 meters respectively). Uniformity varied widely within individual lateral lengths and between circuit types. Under CTMTIS uniformity values were 97.74, 95.14, and 92.03 %;with COMTIS they were 95.73, 89.45, and 83.25 %;and with TTIS they were 88.27, 84.73, and 80.53 % (for lateral lengths 40, 60, 80 meters respectively). The greatest uniformity was observed under CTMTIS and COMTIS when using the shortest lateral length 40 meters, then lateral length 60 meters, while the lowest value was observed when using lateral length 80 meters this result depends on the physical and hydraulic characteristics of the emitter and lateral line. CTMTIS was more uniform than either COMTIS or TTIS. Friction losses were decreased with CTMTIS in the emitter laterals at lengths 40 meters compared to TTIS and COMTIS. Therefore, differences may be related to increased friction losses when using TDIS and COMDIS.
文摘内蒙古巴彦淖尔地区某110 k V变电站主变压器由于恶劣的气象条件导致跳闸故障,造成主变压器三侧断路器跳开,差动保护和本体重瓦斯保护动作。事故发生后,采用油色谱分析、绕组变形及直流电阻测试、电容量变化率分析等多种方法判断主变压器的受损部位、受损程度,经验证发现试验结论均一致。本文采用的几种方法可为今后其他变电站准确判断变压器受损部位及受损程度提供参考。