期刊文献+
共找到153篇文章
< 1 2 8 >
每页显示 20 50 100
Pedestrian flow through exit:Study focused on evacuation pattern
1
作者 张博思 余志红 +2 位作者 孙柏林 郭紫钰 陈默 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期755-764,共10页
Experiments are conducted on the evacuation rate of pedestrians through exits with queued evacuation pattern and random evacuation pattern. The experimental results show that the flow rate of pedestrians is larger wit... Experiments are conducted on the evacuation rate of pedestrians through exits with queued evacuation pattern and random evacuation pattern. The experimental results show that the flow rate of pedestrians is larger with the random evacuation pattern than with the queued evacuation pattern. Therefore, the exit width calculated based on the minimum evacuation clear width for every 100 persons, which is on the assumption that the pedestrians pass through the exit in one queue or several queues, is conservative. The number of people crossing the exit simultaneously is greater in the random evacuation experiments than in the queued evacuation experiments, and the time interval between the front row and rear row of people is shortened in large-exit conditions when pedestrians evacuate randomly. The difference between the flow rate with a queued evacuation pattern and the flow rate with a random evacuation pattern is related to the surplus width of the exit, which is greater than the total width of all accommodated people streams. Two dimensionless quantities are defined to explore this relationship. It is found that the difference in flow rate between the two evacuation patterns is stable at a low level when the surplus width of the exit is no more than 45% of the width of a single pedestrian stream. There is a great difference between the flow rate with the queued evacuation pattern and the flow rate with the random evacuation pattern in a scenario with a larger surplus width of the exit. Meanwhile, the pedestrians crowd extraordinarily at the exit in these conditions as well, since the number of pedestrians who want to evacuate through exit simultaneously greatly exceeds the accommodated level. Therefore, the surplus width of exit should be limited especially in the narrow exit condition, and the relationship between the two dimensionless quantities mentioned above could provide the basis to some extent. 展开更多
关键词 EVACUATION exit width flow rate queued evacuation pattern random evacuation pattern
下载PDF
Comparison of the precision of glacier flow rates derived from offset-tracking using Sentinel-2 and Landsat-8/9 imagery
2
作者 YANG Zhibin CHEN Zhuoqi +3 位作者 LI Gang MAO Yanting FENG Xiaoman CHENG Xiao 《Advances in Polar Science》 CSCD 2024年第2期238-251,共14页
Offset-tracking is an essential method for deriving glacier flow rates using optical imagery.Sentinel-2(S2)and Landsat-8/9(L8/9)are popular optical satellites or constellations for polar studies,offering high spatial ... Offset-tracking is an essential method for deriving glacier flow rates using optical imagery.Sentinel-2(S2)and Landsat-8/9(L8/9)are popular optical satellites or constellations for polar studies,offering high spatial resolution with relatively short revisit time,wide swath width,and free accessibility.To evaluate and compare the precision of offset-tracking results yielded with these two kinds of data,in this study S2 and L8/9 imagery observed in Petermann Glacier in Greenland,Karakoram in High-Mountains Asia,and Amery Ice Shelf in the Antarctic are analyzed.Outliers and various systematic error sources in the offset-tracking results including orbital and strip errors were analyzed and eliminated at the pre-process stage.Precision at the off-glacier(bare rock)region was evaluated by presuming that no deformation occurred;then for both glacierized and the off-glacier regions,precision of velocity time series was evaluated based on error propagation theory.The least squares method based on connected components was used to solve flow rates time series based on multi-pair images offset-tracking.The results indicated that S2 achieved slightly higher precision than L8/9 in terms of both single-pair derived displacements and least square solved daily flow rates time series.Generally,the RMSE of daily velocity is 26%lower for S2 than L8/9.Moreover,S2 provided higher temporal resolution for monitoring glacier flow rates. 展开更多
关键词 Sentinel-2 LANDSAT glacier flow rates offset-tracking PRECISION
下载PDF
Flow Rate Measurement of Gravity Infusion Set and Functional Evaluation of Drop Counter: A Pilot Study
3
作者 Rina Sakai Shuichi Tanaka +3 位作者 Kaya Murakami Tomomi Mizuhashi Kazuhiro Yoshida Masanobu Ujihira 《Journal of Biomedical Science and Engineering》 2024年第7期129-135,共7页
Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate ... Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management. 展开更多
关键词 Gravity Infusion Set Drop Counter IV Fluids flow Rate Trumpet Curves
下载PDF
DYNAMIC CHARACTERISTICS OF LARGE FLOW RATING ELECTROHYDRAULIC PROPORTIONAL CARTRIDGE VALVE 被引量:10
4
作者 FU Linjian WEI Jianhua QIU Minxiu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第6期57-62,共6页
A kind of cartridge servo proportional valve is discussed, which can be used for controlling large flow rate with high performance. By analyzing the structure principle of the valve, the transfer fimction of the valve... A kind of cartridge servo proportional valve is discussed, which can be used for controlling large flow rate with high performance. By analyzing the structure principle of the valve, the transfer fimction of the valve is derived. With the transfer function, some structure elements that may affect its performance are investigated. Through the numerical simulation and test study, some principles of optimality and effective methods for improving the dynamic performance of the valve are proposed. The test results conform to the results of the theoretical analysis and simulation, which proves the correctness of the study and simulation works. The paper provides theoretical basis for engineering applications and series expanding design works 展开更多
关键词 Large flow rate electro-hydraulic proportional cartridge valve Dynamic characteristics
下载PDF
Dynamic behavior of a rotating gliding arc plasma in nitrogen:effects of gas flow rate and operating current 被引量:1
5
作者 张浩 朱凤森 +1 位作者 李晓东 杜长明 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第4期42-47,共6页
The effects of feed gas flow rate and operating current on the electrical characteristics and dynamic behavior of a rotating gliding arc (RGA) plasma codriven by a magnetic field and tangential flow were investigate... The effects of feed gas flow rate and operating current on the electrical characteristics and dynamic behavior of a rotating gliding arc (RGA) plasma codriven by a magnetic field and tangential flow were investigated.The operating current has been shown to significantly affect the time-resolved voltage waveforms of the discharge,particularly at flow rate =21 min^-1.When the current was lower than 140 mA,sinusoidal waveforms with regular variation periods of 13.5-17.0 ms can be observed (flow rate =21 min^-1).The restrike mode characterized by serial sudden drops of voltage appeared under all studied conditions.Increasing the flow rate from 8 to 121 min^-1 (at the same current) led to a shift of arc rotation mode which would then result in a significant drop of discharge voltage (around 120-200 V).For a given flow rate,the reduction of current resulted in a nearly linear increase of voltage. 展开更多
关键词 rotating gliding arc (RGA) electrical characteristics gas flow rate operating current rotation mode
下载PDF
Effect of gas blowing nozzle angle on multiphase flow and mass transfer during RH refining process 被引量:1
6
作者 Jiahao Wang Peiyuan Ni +2 位作者 Chao Chen Mikael Ersson Ying Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第5期844-856,共13页
A three-dimensional mathematical model was developed to investigate the effect of gas blowing nozzle angles on multiphase flow,circulation flow rate,and mixing time during Ruhrstahl-Heraeus(RH) refining process.Also,a... A three-dimensional mathematical model was developed to investigate the effect of gas blowing nozzle angles on multiphase flow,circulation flow rate,and mixing time during Ruhrstahl-Heraeus(RH) refining process.Also,a water model with a geometric scale of 1:4 from an industrial RH furnace of 260 t was built up,and measurements were carried out to validate the mathematical model.The results show that,with a conventional gas blowing nozzle and the total gas flow rate of 40 L·min^(-1),the mixing time predicted by the mathematical model agrees well with the measured values.The deviations between the model predictions and the measured values are in the range of about 1.3%–7.3% at the selected three monitoring locations,where the mixing time was defined as the required time when the dimensionless concentration is within 3% deviation from the bath averaged value.In addition,the circulation flow rate was 9 kg·s^(-1).When the gas blowing nozzle was horizontally rotated by either 30° or 45°,the circulation flow rate was found to be increased by about 15% compared to a conventional nozzle,due to the rotational flow formed in the up-snorkel.Furthermore,the mixing time at the monitoring point 1,2,and 3 was shortened by around 21.3%,28.2%,and 12.3%,respectively.With the nozzle angle of 30° and 45°,the averaged residence time of 128 bubbles in liquid was increased by around 33.3%. 展开更多
关键词 Ruhrstahl-Heraeus refining gas blowing nozzle angle circulation flow rate mixing time multiphase flow
下载PDF
Relation of tea ingestion to salivary redox and flow rate in healthy subjects
7
作者 Pik Han Chong Qiaojuan He +4 位作者 Suyun Zhang Jianwu Zhou Pingfan Rao Min Zhang Lijing Ke 《Food Science and Human Wellness》 SCIE CSCD 2023年第6期2336-2343,共8页
The biochemistry of human saliva can be altered by food intake.The benefits of tea drinking were extensively studied but the influence of tea ingestion on human saliva has not been revealed.The work aimed to investiga... The biochemistry of human saliva can be altered by food intake.The benefits of tea drinking were extensively studied but the influence of tea ingestion on human saliva has not been revealed.The work aimed to investigate the immediate and delayed effect of vine tea,oolong tea and black tea intake on certain salivary biochemistry and flow rate.The saliva samples of healthy subjects were collected before,after and 30 min after tea ingestion.The chemical compositions and antioxidant capacity of tea samples were analyzed to correlate with salivary parameters.Principal component analysis indicated that the effects of vine tea consumption were dominated by increasing salivary flow rate(SFR),production rate of total protein(TPC),thiol(SH),malondialdehyde,catalase activity and antioxidant capacity(FRAP)in saliva.The antioxidant profile of studied tea samples(FRAP,polyphenols,flavonoids)was positively correlated with salivary SFR,TPC,SH and FRAP but negatively correlated with salivary uric acid concentration in saliva. 展开更多
关键词 Black tea flow rate Oolong tea Salivary redox status Vine tea
下载PDF
System Energy and Efficiency Analysis of 12.5 W VRFB with Different Flow Rates
8
作者 Kehuan Xie Longhai Yu Chuanchang Li 《Energy Engineering》 EI 2023年第12期2903-2915,共13页
Vanadium redox flow battery(VRFB)is considered one of the most potential large-scale energy storage technolo-gies in the future,and its electrolyte flow rate is an important factor affecting the performance of VRFB.To... Vanadium redox flow battery(VRFB)is considered one of the most potential large-scale energy storage technolo-gies in the future,and its electrolyte flow rate is an important factor affecting the performance of VRFB.To study the effect of electrolyte flow rate on the performance of VRFB,the hydrodynamic model is established and a VRFB system is developed.The results show that under constant current density,with the increase of electrolyte flow rate,not only the coulombic efficiency,energy efficiency,and voltage efficiency will increase,but also the capacity and energy discharged by VRFB will also increase.But on the other hand,as the flow rate increases,the power of the pump also increases,resulting in a decrease in system efficiency.The energy discharged by the system does not increase with the increase in flow rate.Considering the balance between efficiency and pump power loss,it is experimentally proved that 120 mL·min-1 is the optimal working flow rate of the VRFB system,which can maximize the battery performance and discharge more energy. 展开更多
关键词 Vanadium redox flow battery flow rate system energy EFFICIENCY
下载PDF
Experimental Analysis of the Flow Characteristics of an Adjustable Critical-Flow Venturi Nozzle
9
作者 Chun Ye Jingjing Gao +4 位作者 Zhihui Wang Weibiao Zheng Yibei Wang Xingkai Zhang Ming Liu 《Fluid Dynamics & Materials Processing》 EI 2023年第3期754-765,共12页
The response of an adjustable critical-flow Venturi nozzle is investigated through a set indoor experiments aimed to determine the related critical flow rate,critical pressure ratio,and discharge coefficient.The effec... The response of an adjustable critical-flow Venturi nozzle is investigated through a set indoor experiments aimed to determine the related critical flow rate,critical pressure ratio,and discharge coefficient.The effect of a variation in the cone displacement and liquid content on the critical flow characteristics is examined in detail and it is shown that the former can be used to effectively adjust the critical flow rate.The critical pressure ratio of the considered nozzle is above 0.85,and the critical flow control deviation of the gas flow is within±3%.Liquid flow can reduce the gas critical mass flow rate accordingly,especially for the cases with larger liquid volume and lower inlet pressure.The set of results and conclusions provided are intended to support the optimization of steam injection techniques in the context of heavy oil recovery processes. 展开更多
关键词 Adjustable critical flow venturi nozzle critical pressure ratio critical mass flow rate gas-liquid two-phase critical flow
下载PDF
A Numerical Simulation of Air Flow in the Human Respiratory System Based on Lung Model
10
作者 Md. Kamrul Hasan Mahtab U. Ahmmed Md. Samsul Arefin 《Journal of Applied Mathematics and Physics》 2023年第8期2205-2215,共11页
The lung is an important organ that takes part in the gas exchange process. In the study of gas transport and exchange in the human respiratory system, the complicated process of advection and diffusion (AD) in airway... The lung is an important organ that takes part in the gas exchange process. In the study of gas transport and exchange in the human respiratory system, the complicated process of advection and diffusion (AD) in airways of human lungs is considered. The basis of a lumped parameter model or a transport equation is modeled during the inspiration process, when oxygen enters into the human lung channel. The quantitative measurements of oxygen are detached and the model equation is solved numerically by explicit finite difference schemes. Numerical simulations were made for natural breathing conditions or normal breathing conditions. The respiratory flow results for the resting conditions are found strongly dependent on the AD effect with some contribution of the unsteadiness effect. The contour of the flow rate region is labeled and AD effects are compared with the variation of small intervals of time for a constant velocity when breathing is interrupted for a negligible moment. 展开更多
关键词 Lumped Model Lumped Model Channel Mass flow Rate Ideal Law of Gas 2D Advection Diffusion Equation Finite Difference Scheme
下载PDF
Air pressure law of a reservoir constructed in karst sinkholes
11
作者 YU Bo TAI Shengping +4 位作者 ZHENG Kexun CHEN Shiwan HAN Xiao WANG Senlin ZUO Shuangying 《Journal of Mountain Science》 SCIE CSCD 2024年第3期1048-1057,共10页
Karst sinkholes with natural negative landform provide favorable conditions for the pumped storage reservoir construction for less excavation work.However,the construction of the reservoir would plug the natural karst... Karst sinkholes with natural negative landform provide favorable conditions for the pumped storage reservoir construction for less excavation work.However,the construction of the reservoir would plug the natural karst channels for water and air,which would cause remarkable air pressure in karst channels when the groundwater level fluctuates.A large laboratory simulation test was carried out to study the air pressure variation of a reservoir built on the karst sinkhole.The air pressure in the karst channel and inside the model was monitored during the groundwater rising and falling process.Result showed that the variation of air pressure in the karst channel and the surrounding rock exhibited a high degree of similarity.The air pressure increased rapidly at the initial stage of water level rising,followed by a slight decrease,then the air pressure increased sharply when the water level approached the top of the karst cave.The initial peak of air pressure and the final peak of air pressure were defined,and both air pressure peaks were linearly increasing with the water level rising rate.The negative air pressure was also analyzed during the drainage process,which was linearly correlated with the water level falling rate.The causes of air pressure variation in karst channels of a pumped storage reservoir built on the karst sinkhole were discussed.The initial rapid increase,then slight decrease and final sudden increase of air pressure were controlled by the combined effects of air compression in karst channel and air seepage into the surrounding rock.For the drainage process,the instant negative air pressure and gradual recovering of air pressure were controlled by the combined effects of negative air pressure induced by water level falling and air supply from surrounding rock.This work could provide valuable reference for the reservoir construction in karst area. 展开更多
关键词 Simulation test Karst sinkhole Pumped storage reservoir Air pressure flow rate
下载PDF
Effect of droplet characteristics on liquid-phase distribution in spray zone of internal mixing air-mist nozzle
12
作者 Wei-li Wu Chang-gui Cheng +2 位作者 Yang Li Shi-fa Wei De-li Chen 《China Foundry》 SCIE EI CAS CSCD 2024年第2期185-196,共12页
In continuous casting production,droplet characteristics are important parameters for evaluating the nozzle atomization quality,and have a significant impact on the secondary cooling effect and the slab quality.In ord... In continuous casting production,droplet characteristics are important parameters for evaluating the nozzle atomization quality,and have a significant impact on the secondary cooling effect and the slab quality.In order to study the behavior of atomized droplets after reaching the slab surface and to optimize the spray cooling effect,the influence of droplet diameter and droplet velocity on the migration behavior of droplets in the secondary cooling zone was analyzed by FLUENT software.Results show that the droplets in the spray zone and on the slab surface are mainly concentrated in the center,thus,the liquid volume fraction in the center is higher than that of either side.As the droplet diameter increases,the region of high liquid volume fraction on the slab surface becomes wider,and the liquid phase distribution in the slab width direction becomes uneven.Although increasing the droplet velocity at the nozzle exit has little effect on droplet diffusion in the spray zone,the distribution becomes more uneven due to more liquid reaches the slab surface per unit time.A prediction formula of the maximum water flow rate on the slab surface for specific droplet characteristics was proposed based on dimensionless analysis and validated by simulated data.A nozzle spacing of 210 mm was recommended under the working conditions in this study,which ensures effective coverage of the spray water over the slab surface and enhances the distribution uniformity of water flow rate in the transverse direction. 展开更多
关键词 continuous casting secondary cooling zone internal mixing air-mist nozzle droplet characteristics liquid phase distribution water flow rate
下载PDF
Analysis of Maximum Liquid Carrying Capacity Based on Conventional Tubing Plunger Gas Lift
13
作者 Yanqun Yu Wenhao Xu +3 位作者 Yahui Huangfu Jinhai Liu Bensheng Wang Kai Liu 《Energy Engineering》 EI 2024年第6期1521-1533,共13页
China’s unconventional gas fields have a large number of low-productivity and low-efficiency wells, many of whichare located in remote and environmentally harsh mountainous areas. To address the long-term stable prod... China’s unconventional gas fields have a large number of low-productivity and low-efficiency wells, many of whichare located in remote and environmentally harsh mountainous areas. To address the long-term stable productionof these gas wells, plunger-lift technology plays an important role. In order to fully understand and accurately graspthe drainage and gas production mechanisms of plunger-lift, a mechanical model of plunger-liquid column uplift inthe plunger-lift process was established, focusing on conventional plunger-lift systems and representative wellboreconfigurations in the Linxing region. The operating casing pressure of the plunger-lift process and the calculationmethod for the maximum daily fluid production rate based on the work regime with the highest fluid recovery ratewere determined. For the first time, the critical flow rate method was proposed as a constraint for the maximumliquid-carrying capacity of the plunger-lift, and liquid-carrying capacity charts for conventional plunger-lift withdifferent casing sizes were developed. The results showed that for 23/8 casing plunger-lift, with a well depth ofshallower than 808 m, the maximum drainage rate was 33 m3/d;for 27/8 casing plunger-lift, with a well depth ofshallower than 742 m, the maximum drainage rate was 50.15 m3/d;for 31/2 casing plunger-lift, with a well depthof shallower than 560 m, the maximum drainage rate was 75.14 m3/d. This research provides a foundation for thescientific selection of plunger-lift technology and serves as a decision-making reference for developing reasonableplunger-lift work regimes. 展开更多
关键词 Unconventional well conventional tubing string plunger gas lift critical flow rate liquid carry-over chart version
下载PDF
A study of hydrate plug formation in a subsea natural gas pipeline using a novel high-pressure flow loop 被引量:12
14
作者 Li Wenqing Gong Jing +3 位作者 Lü Xiaofang Zhao Jiankui Feng Yaorong Yu Da 《Petroleum Science》 SCIE CAS CSCD 2013年第1期97-105,共9页
The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages i... The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages in the pipeline occur occasionally. To maintain the natural gas flow in the pipeline, we proposed a method for analyzing blockages and ascribed them to the hydrate formation and agglomeration. A new high-pressure flow loop was developed to investigate hydrate plug formation and hydrate particle size, using a mixture of diesel oil, water, and natural gas as experimental fluids. The influences of pressure and initial flow rate were also studied. Experimental results indicated that when the flow rate was below 850 kg/h, gas hydrates would form and then plug the pipeline, even at a low water content (10%) of a water/oil emulsion. Furthermore, some practical suggestions were made for daily management of the subsea pipeline. 展开更多
关键词 Natural gas hydrate BLOCKAGE flow assurance high-pressure loop water cut flow rate
下载PDF
Influences of gas flow rates on melting of particles of HVOF sprayed CoCrW coating and coating properties 被引量:3
15
作者 YANGZhongyuan 《Rare Metals》 SCIE EI CAS CSCD 2004年第1期53-58,共6页
This paper discussed influences of flow rates of O_2, C_3H_8, and compressedair on the melting degree of particles during HVOF (high velocity oxy-fuel) sprayed CoCrW coating.The O_2 flow rate has the maximal effect on... This paper discussed influences of flow rates of O_2, C_3H_8, and compressedair on the melting degree of particles during HVOF (high velocity oxy-fuel) sprayed CoCrW coating.The O_2 flow rate has the maximal effect on the melting of particles, the C_3H_8 flow rate has thesecond, and the compressed air flow rate has the minimal effect. The bond strength of the HVOFsprayed CoCrW coating is over 54 MPa. The porosity ratio of the HVOF sprayed CoCrW coating afteroptimization of gas flow rates is less than 2%. The average microhardness of the coating is up toHV_(0.1) 545. The oxidation amount per unit area of the HVOF sprayed CoCrW coating increases withthe holding time increasing at 800℃. In the same way, the oxidation amount of the coating increasesas the temperature increases. Particularly, the oxidation of the coating drastically increases over850℃. 展开更多
关键词 CoCrW flow rate HVOF bond strength OXIDATION ORTHOGONALITY
下载PDF
Relationship between Formation Water Rate,Equivalent Penetration Rate and Volume Flow Rate of Air in Air Drilling 被引量:2
16
作者 Wang Kexiong Zhang Laibin Jiang Hongwei 《Petroleum Science》 SCIE CAS CSCD 2007年第4期62-65,共4页
Formation water invasion is the most troublesome problem associated with air drilling. However, it is not economical to apply mist drilling when only a small amount of water flows into wellbore from formation during a... Formation water invasion is the most troublesome problem associated with air drilling. However, it is not economical to apply mist drilling when only a small amount of water flows into wellbore from formation during air drilling. Formation water could be circulated out of the wellbore through increasing the gas injection rate. In this paper, the Angel model was modified by introducing Nikurade friction factor for the flow in coarse open holes and translating formation water rate into equivalent penetration rate. Thus the distribution of annular pressure and the relationship between minimum air injection rate and formation water rate were obtained. Real data verification indicated that the modified model is more accurate than the Angel model and can provide useful information for air drilling. 展开更多
关键词 Air drilling Angel model modified model formation water rate minimum volume flow rate equivalent penetration rate
下载PDF
COMPUTATIONAL FLOW RATE FEEDBACK AND CONTROL METHOD IN HYDRAULIC ELEVATORS 被引量:6
17
作者 Xu Bing Ma Jien Lin Jianjie 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第4期490-493,共4页
The computational flow rate feedback and control method, which can be used in proportional valve controlled hydraulic elevators, is discussed and analyzed. In a hydraulic elevator with this method, microprocessor rece... The computational flow rate feedback and control method, which can be used in proportional valve controlled hydraulic elevators, is discussed and analyzed. In a hydraulic elevator with this method, microprocessor receives pressure information from the pressure transducers and computes the flow rate through the proportional valve based on pressure-flow conversion real time algorithm. This hydraulic elevator is of lower cost and energy consumption than the conventional closed loop control hydraulic elevator whose flow rate is measured by a flow meter. Experiments arc carried out on a test rig which could simulate the load of hydraulic elevator. According to the experiment results, the means to modify the pressure-flow conversion algorithm are pointed out. 展开更多
关键词 Hydraulic elevator Computational flow rate Proportional valve
下载PDF
Development of a Novel Parallel-spool Pilot Operated High-pressure Solenoid Valve with High Flow Rate and High Speed 被引量:6
18
作者 DONG Dai LI Xiaoning 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第2期369-378,共10页
High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate a... High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously.A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system.A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design.Mathematical models of the opening process and flow rate of the valve are established.Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response.Corresponding formulas to solve 4 parts of the response time are derived.Key factors that influence the opening response time are analyzed.According to the mathematical model of the valve,a simulation of the opening process is carried out by MATLAB.Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve.Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool.The experimental results are in agreement with the simulated results,therefore the validity of the theoretical analysis is verified.Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa.The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s.According to the result of the load driving test,the valve can meet the demands of the driving system.The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate. 展开更多
关键词 high-pressure pneumatic solenoid valve parallel-spool high flow rate high speed opening response time
下载PDF
Simplified graphical correlation for determining flow rate in tight gas wells in the Sulige gas field 被引量:1
19
作者 Xiao Wei Wu Xiaodong Liu Xiaojuan 《Petroleum Science》 SCIE CAS CSCD 2008年第3期258-262,共5页
The Sulige tight gas reservoir is characterized by low-pressure, low-permeability and lowabundance. During production, gas flow rate and reservoir pressure decrease sharply; and in the shut- in period, reservoir press... The Sulige tight gas reservoir is characterized by low-pressure, low-permeability and lowabundance. During production, gas flow rate and reservoir pressure decrease sharply; and in the shut- in period, reservoir pressure builds up slowly. Many conventional methods, such as the indicative curve method, systematic analysis method and numerical simulation, are not applicable to determining an appropriate gas flow rate. Static data and dynamic performance show permeability capacity, kh is the most sensitive factor influencing well productivity, so criteria based on kh were proposed to classify vertical wells. All gas wells were classified into 4 groups. A multi-objective fuzzy optimization method, in which dimensionless gas flow rate, period of stable production, and recovery at the end of the stable production period were selected as optimizing objectives, was established to determine the reasonable range of gas flow rate. In this method, membership functions of above-mentioned optimizing factors and their weights were given. Moreover, to simplify calculation and facilitate field use, a simplified graphical illustration (or correlation) was given for the four classes of wells. Case study illustrates the applicability of the proposed method and graphical correlation, and an increase in cumulative gas production up to 37% is achieved and the well can produce at a constant flow rate for a long time. 展开更多
关键词 Low-permeability reservoir sand thickness fuzzy optimization method gas flow rate
下载PDF
Influences of nitrogen flow rate on the structures and properties of Ti and N co-doped diamond-like carbon films deposited by arc ion plating 被引量:1
20
作者 张林 马国佳 +2 位作者 林国强 马贺 韩克昌 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第4期616-621,共6页
In this paper, Ti-C-N nanocomposite films are deposited under different nitrogen flow rates by pulsed bias arc ion plating using Ti and graphite targets in the Ar/N2 mixture gas. The surface morphologies, compositions... In this paper, Ti-C-N nanocomposite films are deposited under different nitrogen flow rates by pulsed bias arc ion plating using Ti and graphite targets in the Ar/N2 mixture gas. The surface morphologies, compositions, microstructures, and mechanical properties of the Ti-C-N films are investigated systematically by field emission scanning electron mi- croscopy (FE-SEM), x-ray photoelectron spectroscopy (XPS), grazing incident x-ray diffraction (GIXRD), Raman spectra, and nano-indentation. The results show that the nanocrystalline Ti(C,N) phase precipitates in the film from GIXRD and XPS analysis, and Raman spectra prove the presence of diamond-like carbon, indicating the formation of nanocomposite film with microstructures comprising nanocrystalline Ti(C,N) phase embedded into a diamond-like matrix. The nitrogen flow rate has a significant effect on the composition, structure, and properties of the film. The nano-hardness and elastic modulus first increase and then decrease as nitrogen flow rate increases, reaching a maximum of 34.3 GPa and 383.2 GPa, at a nitrogen flow rate of 90 sccm, respectively. 展开更多
关键词 arc ion plating Ti-C-N film nitrogen flow rate microstructure
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部