期刊文献+
共找到10,140篇文章
< 1 2 250 >
每页显示 20 50 100
Reactive Power Flow Convergence Adjustment Based on Deep Reinforcement Learning
1
作者 Wei Zhang Bin Ji +3 位作者 Ping He Nanqin Wang Yuwei Wang Mengzhe Zhang 《Energy Engineering》 EI 2023年第9期2177-2192,共16页
Power flow calculation is the basis of power grid planning and many system analysis tasks require convergent power flow conditions.To address the unsolvable power flow problem caused by the reactive power imbalance,a ... Power flow calculation is the basis of power grid planning and many system analysis tasks require convergent power flow conditions.To address the unsolvable power flow problem caused by the reactive power imbalance,a method for adjusting reactive power flow convergence based on deep reinforcement learning is proposed.The deep reinforcement learning method takes switching parallel reactive compensation as the action space and sets the reward value based on the power flow convergence and reactive power adjustment.For the non-convergence power flow,the 500 kV nodes with reactive power compensation devices on the low-voltage side are converted into PV nodes by node type switching.And the quantified reactive power non-convergence index is acquired.Then,the action space and reward value of deep reinforcement learning are reasonably designed and the adjustment strategy is obtained by taking the reactive power non-convergence index as the algorithm state space.Finally,the effectiveness of the power flow convergence adjustment algorithm is verified by an actual power grid system in a province. 展开更多
关键词 power flow calculation reactive power flow convergence node type switching deep reinforcement learning
下载PDF
Research on Reactive Power Optimization of Offshore Wind Farms Based on Improved Particle Swarm Optimization
2
作者 Zhonghao Qian Hanyi Ma +5 位作者 Jun Rao Jun Hu Lichengzi Yu Caoyi Feng Yunxu Qiu Kemo Ding 《Energy Engineering》 EI 2023年第9期2013-2027,共15页
The lack of reactive power in offshore wind farms will affect the voltage stability and power transmission quality of wind farms.To improve the voltage stability and reactive power economy of wind farms,the improved p... The lack of reactive power in offshore wind farms will affect the voltage stability and power transmission quality of wind farms.To improve the voltage stability and reactive power economy of wind farms,the improved particle swarmoptimization is used to optimize the reactive power planning in wind farms.First,the power flow of offshore wind farms is modeled,analyzed and calculated.To improve the global search ability and local optimization ability of particle swarm optimization,the improved particle swarm optimization adopts the adaptive inertia weight and asynchronous learning factor.Taking the minimum active power loss of the offshore wind farms as the objective function,the installation location of the reactive power compensation device is compared according to the node voltage amplitude and the actual engineering needs.Finally,a reactive power optimizationmodel based on Static Var Compensator is established inMATLAB to consider the optimal compensation capacity,network loss,convergence speed and voltage amplitude enhancement effect of SVC.Comparing the compensation methods in several different locations,the compensation scheme with the best reactive power optimization effect is determined.Meanwhile,the optimization results of the standard particle swarm optimization and the improved particle swarm optimization are compared to verify the superiority of the proposed improved algorithm. 展开更多
关键词 Offshore wind farms improved particle swarm optimization reactive power optimization adaptive weight asynchronous learning factor voltage stability
下载PDF
An Improved Catastrophic Genetic Algorithm and Its Application in Reactive Power Optimization 被引量:4
3
作者 Ouyang Sen 《Energy and Power Engineering》 2010年第4期306-312,共7页
This paper presents an Improved Catastrophic Genetic Algorithm (ICGA) for optimal reactive power optimization. Firstly, a new catastrophic operator to enhance the genetic algorithms’ convergence stability is proposed... This paper presents an Improved Catastrophic Genetic Algorithm (ICGA) for optimal reactive power optimization. Firstly, a new catastrophic operator to enhance the genetic algorithms’ convergence stability is proposed. Then, a new probability algorithm of crossover depending on the number of generations, and a new probability algorithm of mutation depending on the fitness value are designed to solving the main conflict of the convergent speed with the global astringency. In these ways, the ICGA can prevent premature convergence and instability of genetic-catastrophic algorithms (GCA). Finally, the ICGA is applied for power system reactive power optimization and evaluated on the IEEE 14-bus power system, and the application results show that the proposed method is suitable for reactive power optimization in power system. 展开更多
关键词 GENETIC ALGORITHMS reactive power Optimization CATASTROPHE power System
下载PDF
Chaos quantum particle swarm optimization for reactive power optimization considering voltage stability 被引量:2
4
作者 瞿苏寒 马平 蔡兴国 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2010年第3期351-356,共6页
The reactive power optimization considering voltage stability is an effective method to improve voltage stablity margin and decrease network losses,but it is a complex combinatorial optimization problem involving nonl... The reactive power optimization considering voltage stability is an effective method to improve voltage stablity margin and decrease network losses,but it is a complex combinatorial optimization problem involving nonlinear functions having multiple local minima and nonlinear and discontinuous constraints. To deal with the problem,quantum particle swarm optimization (QPSO) is firstly introduced in this paper,and according to QPSO,chaotic quantum particle swarm optimization (CQPSO) is presented,which makes use of the randomness,regularity and ergodicity of chaotic variables to improve the quantum particle swarm optimization algorithm. When the swarm is trapped in local minima,a smaller searching space chaos optimization is used to guide the swarm jumping out the local minima. So it can avoid the premature phenomenon and to trap in a local minima of QPSO. The feasibility and efficiency of the proposed algorithm are verified by the results of calculation and simulation for IEEE 14-buses and IEEE 30-buses systems. 展开更多
关键词 reactive power optimization voltage stability margin quantum particle swarm optimization chaos optimization
下载PDF
Power System Reactive Power Optimization Based on Fuzzy Formulation and Interior Point Filter Algorithm 被引量:1
5
作者 Zheng Fan Wei Wang +3 位作者 Tian-jiao Pu Guang-yi Liu Zhi Cai Ning Yang 《Energy and Power Engineering》 2013年第4期693-697,共5页
Considering the soft constraint characteristics of voltage constraints, the Interior-Point Filter Algorithm is applied to solve the formulation of fuzzy model for the power system reactive power optimization with a la... Considering the soft constraint characteristics of voltage constraints, the Interior-Point Filter Algorithm is applied to solve the formulation of fuzzy model for the power system reactive power optimization with a large number of equality and inequality constraints. Based on the primal-dual interior-point algorithm, the algorithm maintains an updating “filter” at each iteration in order to decide whether to admit correction of iteration point which can avoid effectively oscillation due to the conflict between the decrease of objective function and the satisfaction of constraints and ensure the global convergence. Moreover, the “filter” improves computational efficiency because it filters the unnecessary iteration points. The calculation results of a practical power system indicate that the algorithm can effectively deal with the large number of inequality constraints of the fuzzy model of reactive power optimization and satisfy the requirement of online calculation which realizes to decrease the network loss and maintain specified margins of voltage. 展开更多
关键词 power System reactive power Optimization FUZZY Filter INTERIOR-POINT Algorithm Online Calculation
下载PDF
Two-stage ADMM-based distributed optimal reactive power control method for wind farms considering wake effects 被引量:3
6
作者 Zhenming Li Zhao Xu +2 位作者 Yawen Xie Donglian Qi Jianliang Zhang 《Global Energy Interconnection》 EI CAS CSCD 2021年第3期251-260,共10页
Since the connection of small-scale wind farms to distribution networks,power grid voltage stability has been reduced with increasing wind penetration in recent years,owing to the variable reactive power consumption o... Since the connection of small-scale wind farms to distribution networks,power grid voltage stability has been reduced with increasing wind penetration in recent years,owing to the variable reactive power consumption of wind generators.In this study,a two-stage reactive power optimization method based on the alternating direction method of multipliers(ADMM)algorithm is proposed for achieving optimal reactive power dispatch in wind farm-integrated distribution systems.Unlike existing optimal reactive power control methods,the proposed method enables distributed reactive power flow optimization with a two-stage optimization structure.Furthermore,under the partition concept,the consensus protocol is not needed to solve the optimization problems.In this method,the influence of the wake effect of each wind turbine is also considered in the control design.Simulation results for a mid-voltage distribution system based on MATLAB verified the effectiveness of the proposed method. 展开更多
关键词 Two-stage optimization reactive power optimization Grid-connected wind farms Alternating direction method of multipliers(ADMM)
下载PDF
Electrical Energy Transmission by Several Wires and Reactive Power Problems 被引量:2
7
作者 Michael Bank 《Engineering(科研)》 2018年第6期329-335,共7页
The main goal of this article is to compare traditional three phase system with one wire three-phase system. There are several obvious advantages of one wire system, for example cost, reliability and other. But there ... The main goal of this article is to compare traditional three phase system with one wire three-phase system. There are several obvious advantages of one wire system, for example cost, reliability and other. But there is a problem as well, connected to reactive power in both systems. This article proposes explanation of reactive power emergence in systems SWER, three-phase and in their one wire versions. 展开更多
关键词 THREE-PHASE SYSTEM SWER Single LINE SYSTEM reactive power
下载PDF
Reactive Power Compensation and Harmonic Suppression for Power Supply System of HT-7U Superconductive Tokamak 被引量:1
8
作者 陶骏 刘正之 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第1期629-635,共7页
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design... In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load. 展开更多
关键词 In reactive power Compensation and Harmonic Suppression for power Supply System of HT-7U Superconductive Tokamak APF HT
下载PDF
A Genetic Algorithm for Reactive Power Optimizationof Power System
9
作者 蔡兴国 刘林强 +1 位作者 柳焯 郭冬梅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第2期63-66,共4页
Tis paper presents a genetic algorithm for reactive power optimization of power system in a more effective and rapid manner, and verifies the results with an IEEE 30-bus test system.
关键词 power system GENETIC algorithm(GA) reactive power optimization
下载PDF
Minimization of Reactive Power Fluctuation in JT-60SA Magnet Power Supply
10
作者 K. SHIMADA T. TERAKADO +5 位作者 K. YAMAUCHI M. MATSUKAWA O. BAULAIGUE R. COLETTI A. COLETTI L. NOVELLO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期184-187,共4页
This paper describes an asymmetric control method for the firing angle and a start/stop timing shift control of four thyristor converters called "Booster PS" to minimize the reactive power fluctuation during plasma ... This paper describes an asymmetric control method for the firing angle and a start/stop timing shift control of four thyristor converters called "Booster PS" to minimize the reactive power fluctuation during plasma initiation in JT-60SA. From the simulation using the "PSCAD/EMTDC" code, it is found that these control methods can drastically reduce the reac- tive power induced by the four units of the "Booster PS". In addition, the voltage fluctuation of the motor-generator connected to the "Booster PS" is expected to be suppressed. This can also contribute to achieve stable control of the JT-60SA magnet power supplies. 展开更多
关键词 JT-60SA power supply poroidal field coil reactive power fluctuation asym-metric control PSCAD/EMTDC
下载PDF
Design to conditioning circuits of dynamic compensation of reactive power in the intelligence voltage controller
11
作者 Yong-qin WEI,Yin-jing GUO (College of Infor.&Elec.Eng,Shan dong university of science of technology,Qingdao266510,china) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期111-113,共3页
The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easi... The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate. 展开更多
关键词 reactive power COMPENSATION Real-timely control DY
下载PDF
Analysis on the Application of Reactive Power Compensation Technology in Electrical Automation 被引量:1
12
作者 Rumin LIU Lingzhi YANG Haiming LIU 《International Journal of Technology Management》 2015年第2期118-121,共4页
关键词 无功补偿技术 应用程序 电力自动化 电气自动化 配电系统 高次谐波电流 电压稳定 无功功率
下载PDF
Reactive Power Reserve Improvement Using Power Systems Inherent Structural Characteristics
13
作者 Tajudeen H. Sikiru Adisa A. Jimoh +2 位作者 Yskandar Hamam John T. Agee Roger Ceschi 《Energy and Power Engineering》 2013年第4期986-991,共6页
This paper considers the use of the inherent structural characteristics of power system networks for improving the reactive power reserve margins for both topologically weak and strong networks. The inherent structura... This paper considers the use of the inherent structural characteristics of power system networks for improving the reactive power reserve margins for both topologically weak and strong networks. The inherent structural characteristics of the network are derived from the Schur complement of the partitioned Y-admittance matrix using circuit theory representations. Results show that topologically strong networks, operating close to the upper voltage limit could be made to increase their loadability margin by locating reactive power compensators close to generator sources, whereas topologically weak (ill conditioned) networks could be made to operate within the feasible operating limits by locating reactive power compensators on buses farther from generator sources. 展开更多
关键词 power System Networks Inherent Characteristics reactive power RESERVE MARGIN Loadability MARGIN SCHUR COMPLEMENT
下载PDF
Research of Rural Power Network Reactive Power Optimization Based on Improved ACOA
14
作者 YU Qian ZHAO Yulin WANG Xintao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2010年第3期48-52,共5页
In view of the serious reactive power loss in the rural network, improved ant colony optimization algorithm (ACOA) was used to optimize the reactive power compensation for the rural distribution system. In this stud... In view of the serious reactive power loss in the rural network, improved ant colony optimization algorithm (ACOA) was used to optimize the reactive power compensation for the rural distribution system. In this study, the traditional ACOA was improved in two aspects: one was the local search strategy, and the other was pheromone mutation and re-initialization strategies. The reactive power optimization for a county's distribution network showed that the improved ACOA was practicable. 展开更多
关键词 rural power network reactive power optimization ant colony optimization algorithm local search strategy pheromone mutation and re-initialization strategy
下载PDF
Dispersed Wind Power Planning Method Considering Network Loss Correction with Cold Weather
15
作者 Hanpeng Kou Tianlong Bu +2 位作者 Leer Mao Yihong Jiao Chunming Liu 《Energy Engineering》 EI 2024年第4期1027-1048,共22页
In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is... In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is proposed in the paper,which takes into account the network loss correction for the extreme cold region.Firstly,an electro-thermal model is introduced to reflect the effect of temperature on conductor resistance and to correct the results of active network loss calculation;secondly,a two-stage multi-objective two-stage decentralised wind power siting and capacity allocation and reactive voltage optimisation control model is constructed to take account of the network loss correction,and the multi-objective multi-planning model is established in the first stage to consider the whole-life cycle investment cost of WTGs,the system operating cost and the voltage quality of power supply,and the multi-objective planning model is established in the second stage.planning model,and the second stage further develops the reactive voltage control strategy of WTGs on this basis,and obtains the distribution network loss reduction method based on WTG siting and capacity allocation and reactive power control strategy.Finally,the optimal configuration scheme is solved by the manta ray foraging optimisation(MRFO)algorithm,and the loss of each branch line and bus loss of the distribution network before and after the adoption of this loss reduction method is calculated by taking the IEEE33 distribution system as an example,which verifies the practicability and validity of the proposed method,and provides a reference introduction for decision-making for the distributed energy planning of the distribution network. 展开更多
关键词 Decentralised wind power network loss correction siting and capacity determination reactive voltage control two-stage model manta ray foraging optimisation algorithm
下载PDF
Research on the Method of Calculating Node Injected Reactive Power Based on L Indicator
16
作者 Xue Gong Bingcheng Zhang +3 位作者 Bing Kong Anan Zhang Hongwei Li Wei Fang 《Journal of Power and Energy Engineering》 2014年第4期361-367,共7页
With the power grid load increasing, the problem of grid voltage stability is increasingly prominent, and the possibility of voltage instability is also growing. In order to improve the voltage stability, this paper a... With the power grid load increasing, the problem of grid voltage stability is increasingly prominent, and the possibility of voltage instability is also growing. In order to improve the voltage stability, this paper analyzed how the voltage stability was influenced by different reactive power injection based on the simplified L-indicator of on-line voltage stability monitoring. According to the basic differential property of the simplified L-indicator, a general and normative analytical algorithm about reactive power optimization was deduced. The analytical algorithm can calculate the load node injected reactive power, and then the network can run in the optimal steady state on the basis of the calculation results. According to the simulation results of IEEE-14, IEEE-30, IEEE-57 and IEEE-118, the feasibility and effectiveness of the proposed algorithm to improve voltage stability and reduce the risk of grid collapse were verified. 展开更多
关键词 VOLTAGE Stability L-Indicator Injected reactive power reactive power Optimization Fast Calculation
下载PDF
Microcontroller Control of Reactive Power Compensation for Growing Industrial Loads
17
作者 Edwin N. Mbinkar Derek Ajesam Asoh Sulayman Kujabi 《Energy and Power Engineering》 CAS 2022年第9期460-476,共17页
Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving ... Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving the power factor, the customer can reduce its power demand and potentially increase efficiency of their equipment. A PIC microcontroller is used to switch capacitor banks to compensate for the reactive power. In order to determine the size of the capacitor bank needed, the microcontroller calculates the phase difference between the voltage and the current. The results obtained based on the lagging power factor for three test loads show an improvement in the power factor from 0.52 to 0.96 under different test load conditions. 展开更多
关键词 power Factor Compensation Capacitor Bank PIC Microcontroller reactive power
下载PDF
Fuzzy Decision Method Applied in Action of Reactive Power Compensation Devices in Wind System
18
作者 Xueming Li Li Feng +1 位作者 Yi Tang Yonghua Chen 《Journal of Power and Energy Engineering》 2014年第4期280-287,共8页
Frequent occurrence of large-scale cascading trip-off of wind turbine raises the concern about the decision process of ordered control of reactive power compensation devices. The theory of fuzzy multi-attribute decisi... Frequent occurrence of large-scale cascading trip-off of wind turbine raises the concern about the decision process of ordered control of reactive power compensation devices. The theory of fuzzy multi-attribute decision making is adopted to ascertain the action sequence of reactive power compensation devices. First, a set of evaluation indexes including control sensitivity, regulation margin, response time, response level and cost is set up, and fuzziness of the proposed qualitative indexes is introduced to make them comparable to the proposed quantitative indexes. Then a method to calculate fuzzy weight of each index is put forward for evaluating relative importance of the proposed indexes. Finally, the action sequence of reactive power compensation devices is determined through the theory of fuzzy compromise decision making. The case study shows that the proposed method is effective to obtain the action sequence of reactive power compensation device which correspond to experience. 展开更多
关键词 WIND power SYSTEM reactive power Compensation Device ORDERED Control Fuzzy MULTI-ATTRIBUTE DECISION Making Evaluation Index
下载PDF
Reactive Power Problem and Solutions: An Overview
19
作者 Ahmed A. AbdElhafez Saud H. Alruways +3 位作者 Yazeed A. Alsaif Mutlaq F. Althobaiti Abdulmohsen B. AlOtaibi Naif A. Alotaibi 《Journal of Power and Energy Engineering》 2017年第5期40-54,共15页
This article presents a comprehensive review for the dilemma of reactive power flow, while addressing different proposed remedy strategies: conventional and most update solutions. Robust analytical expressions were ut... This article presents a comprehensive review for the dilemma of reactive power flow, while addressing different proposed remedy strategies: conventional and most update solutions. Robust analytical expressions were utilized to exploit the functionality of the proposed solutions and to show clearly the relation between the reactive power and control variables. The article, moreover, proposes a simple, innovative and robust analysis for static performance of the STATCOM. This approach shows clearly the advantages of the STA-TCOM in regulating reactive power and maintaining load voltage level within presumable limits. The approach, furthermore, reveals explicitly via analytical expressions the impact of the STATCOM operation on different aspects of the power system under concern. 展开更多
关键词 COMPENSATION TCR TSC STATCOM reactive power
下载PDF
A New Principle of Fault Identification of on the Same Tower Based on Traveling Wave Reactive Powers
20
作者 Hao Wu Ruikai Ye +2 位作者 Xingxing Dong Kunjian Yu Zhengwei Chang 《Journal of Power and Energy Engineering》 2019年第7期50-70,共21页
In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based ... In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based on the reactive powers of traveling wave is proposed. With the implementation of S-transform, the initial traveling wave reactive powers are calculated and the change characteristics of reactive power under different fault conditions are studied. The protection criterion is constructed by analyzing the ratio of the reactive powers of the same end on double-circuit transmission lines and the ratio of the reactive powers at both ends on the same line. According to the ratio of reactive power on the same side of the line and both ends of the same line, it is possible to identify whether the faults of the double-circuit line of the same tower occurred in or out of the protection zone. A large number of simulation results show that the protection performance is sensitive and reliable, and quick to respond. The criterion is simple and is basically not affected by fault initial angles, fault types, and transitional resistances. 展开更多
关键词 Double-Circuit Transmission Line on the SAME TOWER TRAVELING Wave reactive power S-TRANSFORM Fault Identification
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部