期刊文献+
共找到5,556篇文章
< 1 2 250 >
每页显示 20 50 100
Dynamics and adaptive control of a dual-arm space robot with closed-loop constraints and uncertain inertial parameters 被引量:20
1
作者 Ying-Hong Jia Quan Hu Shi-Jie Xu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2014年第1期112-124,共13页
A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of contro... A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of controlling the po- sition and attitude of both the satellite base and the payload grasped by the manipulator end effectors. The equations of motion in reduced-order form for the constrained system are derived by incorporating the constraint equations in terms of accelerations into Kane's equations of the unconstrained system. Model analysis shows that the resulting equations perfectly meet the requirement of adaptive controller design. Consequently, by using an indirect approach, an adaptive control scheme is proposed to accomplish position/attitude trajectory tracking control with the uncertain parameters be- ing estimated on-line. The actuator redundancy due to the closed-loop constraints is utilized to minimize a weighted norm of the joint torques. Global asymptotic stability is proven by using Lyapunov's method, and simulation results are also presented to demonstrate the effectiveness of the proposed approach. 展开更多
关键词 Space robot Dynamics. Adaptive control closed-loop constraint Parameter uncertainty - Kane's equation
下载PDF
Open-closed Loop ILC Corrected with Angle Relationship of Output Vectors for Tracking Control of Manipulator 被引量:8
2
作者 WANG Hong-Bin WANG Yan 《自动化学报》 EI CSCD 北大核心 2010年第12期1758-1765,共8页
关键词 ILC 自动化 跟踪控制 仿真
下载PDF
Closed-loop control of weld penetration in keyhole plasma arc welding 被引量:2
3
作者 陈强 孙振国 +1 位作者 孙久文 王耀文 《中国有色金属学会会刊:英文版》 CSCD 2004年第1期116-120,共5页
To improve the penetrating ability and the welding quality of keyhole plasma arc welding, a novel penetration closed loop control system was established. In the system, welding current and plasma gas flow rate were se... To improve the penetrating ability and the welding quality of keyhole plasma arc welding, a novel penetration closed loop control system was established. In the system, welding current and plasma gas flow rate were selected as adjusting variables. The wavelet method was used to detect penetration status from welding arc voltage in real time. The control strategy of one keyhole per pulse was adapted to fulfill stable and high quality welding process. Experimental results show that the developed system can apparently increase the penetrating force of plasma arc and keyhole plasma arc welding is realized successfully in stainless steel with 10 mm in thickness. Moreover, the disturbances of gradual change and break change from 3 mm to 6 mm in thickness are come over due to the good response property of the developed system. 展开更多
关键词 焊缝 熔深 闭环控制 等离子弧焊 PAW
下载PDF
An Implanted Closed-loop Chip System for Heart Rate Control:System Design and Effects in Conscious Rats 被引量:3
4
作者 Yuxuan Zhou Yuan Yuan +4 位作者 Juan Gao Ling Yang Feng Zhang Guoqing Zhu Xingya Gao 《The Journal of Biomedical Research》 CAS 2010年第2期107-114,共8页
Objective: To evaluate the efficiency of an implanted chip system for the control of heart rate (HR). Methods: The HR was recorded in six conscious Sprague-Dawley (SD) rats. An implanted chip system was designed... Objective: To evaluate the efficiency of an implanted chip system for the control of heart rate (HR). Methods: The HR was recorded in six conscious Sprague-Dawley (SD) rats. An implanted chip system was designed to regulate the HR by stimulating the right cervical vagus nerve according to the feedback of real time HR. Each rat was subjected to 30-min regulation and 30-min recovery. The change of HR during the regulation period was compared with the control. The ECG was recorded during the experiment for 24 h. Results: The ECG signals were successfully recorded during the experiment. The HR was significantly decreased during the period of regulation compared with control (-79.3 ± 34.5, P 〈 0.01, n = 6) and then recovered to normal after regulation. Conclusion: The described implanted chip system can regulate the HR to a designated set point. 展开更多
关键词 closed-loop regulation implanted chip system set point heart rate vagus nerve stimulation Remote-controlled animal
下载PDF
Open-plus-closed-loop control for chaotic motion of 3D rigid pendulum 被引量:2
5
作者 戈新生 邹奎 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2014年第4期403-412,共10页
An open-plus-closed-loop (OPCL) control problem for the chaotic motion of a 3D rigid pendulum subjected to a constant gravitationM force is studied. The 3D rigid pendulum is assumed to be consist of a rigid body sup... An open-plus-closed-loop (OPCL) control problem for the chaotic motion of a 3D rigid pendulum subjected to a constant gravitationM force is studied. The 3D rigid pendulum is assumed to be consist of a rigid body supported by a fixed and frictionless pivot with three rotational degrees. In order to avoid the singular phenomenon of Euler's angular velocity equation, the quaternion kinematic equation is used to describe the motion of the 3D rigid pendulum. An OPCL controller for chaotic motion of a 3D rigid pendulum at equilibrium position is designed. This OPCL controller contains two parts: the open-loop part to construct an ideal trajectory and the closed-loop part to stabilize the 3D rigid pendulum. Simulation results show that the controller is effective and efficient. 展开更多
关键词 3D rigid pendulum QUATERNION chaotic motion Poincar section open-plus-closed-loop (OPCL) control
下载PDF
A closed-loop particle swarm optimizer for multivariable process controller design 被引量:2
6
作者 Kai HAN Jun ZHAO Zu-hua XU Ji-xin QIAN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第8期1050-1060,共11页
Design of general multivariable process controllers is an attractive and practical alternative to optimizing design by evolutionary algorithms (EAs) since it can be formulated as an optimization problem. A closed-loop... Design of general multivariable process controllers is an attractive and practical alternative to optimizing design by evolutionary algorithms (EAs) since it can be formulated as an optimization problem. A closed-loop particle swarm optimization (CLPSO) algorithm is proposed by mapping PSO elements into the closed-loop system based on control theories. At each time step, a proportional integral (PI) controller is used to calculate an updated inertia weight for each particle in swarms from its last fitness. With this modification, limitations caused by a uniform inertia weight for the whole population are avoided, and the particles have enough diversity. After the effectiveness, efficiency and robustness are tested by benchmark functions, CLPSO is applied to design a multivariable proportional-integral-derivative (PID) controller for a solvent dehydration tower in a chemical plant and has improved its performances. 展开更多
关键词 多变量系统 自动控制理论 控制器 优化程序
下载PDF
Application of Single Neuron Adaptive PID Regulators with Auto-tuning Gain in Industrial Parameter(Pressure)Closed-loop Process Control Systems 被引量:1
7
作者 Shaoyuan Sun Huade Li +1 位作者 Bin Qian Jianping Wei(Information Engineering School, University of Science and Technology Beijing, Beijing 100083, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1999年第2期152-153,共2页
A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of ind... A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of induStrial parameter closed-loop process controlsystems is improved, and the work quality of the systems bettered. 展开更多
关键词 single neuron GAIN adaptiVe PID regulator pressure closed-loop control
下载PDF
Solving position-posture deviation problem of multi-legged walking robots with semi-round rigid feet by closed-loop control 被引量:1
8
作者 陈刚 金波 陈鹰 《Journal of Central South University》 SCIE EI CAS 2014年第11期4133-4141,共9页
The semi-round rigid feet would cause position-posture deviation problem because the actual foothold position is hardly known due to the rolling effect of the semi-round rigid feet during the robot walking. The positi... The semi-round rigid feet would cause position-posture deviation problem because the actual foothold position is hardly known due to the rolling effect of the semi-round rigid feet during the robot walking. The position-posture deviation problem may harm to the stability and the harmony of the robot, or even makes the robot tip over and fail to walk forward. Focused on the position-posture deviation problem of multi-legged walking robots with semi-round rigid feet, a new method of position-posture closed-loop control is proposed to solve the position-posture deviation problem caused by semi-round rigid feet, based on the inverse velocity kinematics of the multi-legged walking robots. The position-posture closed-loop control is divided into two parts: the position closed-loop control and the posture closed-loop control. Thus, the position-posture control for the robot which is a tight coupling and nonlinear system is decoupled. Co-simulations of position-posture open-loop control and position-posture closed-loop control by MATLAB and ADAMS are implemented, respectively. The co-simulation results verify that the position-posture closed-loop control performs well in solving the position-posture deviation problem caused by semi-round rigid feet. 展开更多
关键词 位置闭环控制 步行机器人 位置姿态 位置偏差 半刚性 MATLAB 非线性系统 ADAMS
下载PDF
Study on a Closed-Loop Air-Fuel Control System of Gasoline Engines by Simulation
9
作者 张付军 赵长禄 +1 位作者 黄英 郝利军 《Journal of Beijing Institute of Technology》 EI CAS 2003年第3期296-301,共6页
In order to study the factors that influence the air fuel ratio(A/F), the amplitude and frequency of A/F fluctuation, to reform the control strategy, and to improve the efficiency of three way catalyst(TWC), a model... In order to study the factors that influence the air fuel ratio(A/F), the amplitude and frequency of A/F fluctuation, to reform the control strategy, and to improve the efficiency of three way catalyst(TWC), a model of closed loop control system including the engine, air fuel mixing and transportation, oxygen sensor and controller, etc., is developed. Various factors that influence the A/F control are studied by simulation. The simulation results show that the reference voltage of oxygen sensor will influence the mean value of A/F ratio, the controller parameters will influence the amplitude of A/F fluctuation, and the operating conditions of the engine determine the frequency of A/F fluctuations, the amplitude of A/F fluctuation can be reduced to within demanded values by logical selection of the signal acquisition method and controller parameters. Higher A/F fluctuation frequency under high speed and load can be reduced through software delay in the controller. The A/F closed loop control system based on the simulation results, accompanied with a rare earth element TWC, gives a better efficiency of conversion against harmful emissions. 展开更多
关键词 air fuel ratio closed loop control SIMULATION
下载PDF
Interference Management for DS-CDMA Systems through Closed-Loop Power Control, Base Station Assignment, and Beamforming 被引量:1
10
作者 Mohamad Dosaranian Moghadam Hamidreza Bakhshi Gholamreza Dadashzadeh 《Wireless Sensor Network》 2010年第6期472-482,共11页
In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division m... In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division multiple access (DS-CDMA) receiver with frequency-selective Rayleigh fading. This receiver consists of three stages. In the first stage, with constrained least mean squared (CLMS) algorithm, the desired users’ signal in an arbitrary path is passed and the inter-path interference (IPI) is reduced in other paths in each RAKE finger. Also in this stage, the multiple access interference (MAI) from other users is reduced. Thus, the matched filter (MF) can use for more reduction of the IPI and MAI in each RAKE finger in the second stage. Also in the third stage, the output signals from the matched filters are combined according to the conventional maximal ratio combining (MRC) principle and then are fed into the decision circuit of the desired user. The simulation results indicate that the SSPC algorithm and the BSA-MTP technique can significantly reduce the network bit error rate (BER) compared to the other methods. Also, we observe that significant savings in total transmit power (TTP) are possible with our methods. 展开更多
关键词 Adaptive Beamforming Antenna Array Base Station ASSIGNMENT closed-loop Power control Constrained LMS DS-CDMA
下载PDF
Safety Assessment of Closed-Loop Level Crossing Control Systems by Means of STAMP(Systems-Theoretic Accident Model and Processes)
11
作者 Tetsuya TAKATA Akira ASANO Hideo NAKAMURA 《Journal of Traffic and Transportation Engineering》 2018年第5期241-254,共14页
There have been a large number of accidents at level crossings of railways and this has been considered to be a significant issue to be solved for the realization of safe and stable railway transport.A conventional le... There have been a large number of accidents at level crossings of railways and this has been considered to be a significant issue to be solved for the realization of safe and stable railway transport.A conventional level crossing control system is characterized by the use of two types of electronic train detectors;one detects a train approaching to a level crossing section and the other then detects the train having left the level crossing.By contrast,closed-loop level crossing control systems in which level crossing control equipment and train-borne equipment communicate with each other have been advocated and are expected to serve as an effective solution to the abovementioned issue.This paper describes the following three types of closed-loop level crossing control systems:decentralized level crossing control system,fully-centralized comprehensive level crossing control system and fully-centralized individual level crossing control system.This paper then assesses the safety of these systems in comparison to the conventional level crossing control system.For the purpose of the assessment of their safety,a new accident analysis model called STAMP(systems theoretic accident model and processes)that is suitable for software intensive systems is used to clarify the advantage of the proposed three types of level crossing control systems in terms of safety. 展开更多
关键词 Level CROSSING control railway signaling closed loop control method safety assessment STAMP
下载PDF
Research of the algorithm of the closed-loop control system to control the piezoelectric actuator
12
作者 王广林 刘胜伟 +1 位作者 邵东向 李云峰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第1期31-33,共3页
The piezoelectric actuator has been widely used in precision instruments and precision control. However, hysteresis, nonlinearity and creep exist in the actuator, which limit actuator applications and affect accuracy.... The piezoelectric actuator has been widely used in precision instruments and precision control. However, hysteresis, nonlinearity and creep exist in the actuator, which limit actuator applications and affect accuracy. This thesis introduces fuzzy control as the algorithm of a closed-loop control system to control the piezoelectric actuator. Fuzzy control can make this closed-looped system not only have high linearity, repeatability, accuracy and few overshoot, but isalso easily used. 展开更多
关键词 闭环控制系统 运算法则 压电激励器 模糊控制系统
下载PDF
Closed-loop prevention and control research of coal mine safety management
13
作者 LI Xing-dong ZHAO Yun-xia +1 位作者 ZHAO Xing-qiang LU Ying 《Journal of Coal Science & Engineering(China)》 2009年第3期324-327,共4页
According to the current problems of safety management processes in coalmine enterprises,we introduced barrel theory to coal mine safety management,constructedthe closed-loop structure of a coal mine safety management... According to the current problems of safety management processes in coalmine enterprises,we introduced barrel theory to coal mine safety management,constructedthe closed-loop structure of a coal mine safety management system,andpointed out that efficient safety management lies in three factors:safety quality of all ofthe staff in coal mine enterprises,weak links in security management systems,and cooperationamong departments.After conducting detailed analysis of these three factors,we proposed concrete ways of preventing and controlling potential safety hazards duringthe process of coal mine production. 展开更多
关键词 煤矿安全管理 闭环结构 控制 预防 安全管理制度 煤矿企业 管理程序 木桶理论
下载PDF
Model Reference Adaptive Control for Switched Systems with Closed-loop Reference Model Under Arbitrary Switching
14
作者 Hao Yang Jing Xie Jun Zhao 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期35-42,共8页
This paper explores the model reference adaptive control problem for a class of switched linear systems under arbitrary switching with no need for the measurability of the system state.Based on the state of reference ... This paper explores the model reference adaptive control problem for a class of switched linear systems under arbitrary switching with no need for the measurability of the system state.Based on the state of reference model and the measurable output error, adaptive laws and controllers are designed for switched systems.Each subsystem may have its individual reference model and controller, which increases the design flexibility.The introduction of the closed-loop reference model is to get a better transient performance of the whole switched systems.A numerical example is provided to verify the effectiveness of the main results. 展开更多
关键词 SWITCHED systems MODEL REFERENCE adaptive control common LYAPUNOV function arbitrary switching the closed-loop REFERENCE MODEL
下载PDF
A simulation program for demonstration and analysis of closed loop negative feedback control
15
作者 Thomas Scott Deering Paul 《通讯和计算机(中英文版)》 2009年第7期6-15,共10页
关键词 计算机仿真 仿真程序 模拟 控制
下载PDF
Joint Closed-Loop Power Control and Adaptive Beamforming for Wireless Networks with Antenna Arrays in a 2D Urban Environment
16
作者 Mohamad Dosaranian Moghadam Hamidreza Bakhshi Gholamreza Dadashzadeh 《Wireless Sensor Network》 2010年第11期869-878,共10页
The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we prop... The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we propose smart step closed-loop power control (SSPC) algorithm in wireless networks in a 2D urban environment with constrained least mean squared (CLMS) algorithm. This algorithm is capable of efficiently adapting according to the environment and able to permanently maintain the chosen frequency response in the look direction while minimizing the output power of the array. Also, we present switched-beam (SB) technique for enhancing signal to interference plus noise ratio (SINR) in wireless networks. Also, we study an analytical approach for the evaluation of the impact of power control error (PCE) on wireless networks in a 2D urban environment. The simulation results indicate that the convergence speed of the SSPC algorithm is faster than other algorithms. Also, we observe that significant saving in total transmit power (TTP) are possible with our proposed algorithm. Finally, we discuss three parameters of the PCE, number of antenna elements, and path-loss exponent and their effects on capacity of the system via some computer simulations. 展开更多
关键词 Adaptive Beamforming closed-loop POWER control Matched Filter Urban Signal Propagation Simulator POWER control Error
下载PDF
Method of closed loop springback compensation for incremental sheet forming process 被引量:1
17
作者 韩飞 莫健华 +1 位作者 龚攀 李敏 《Journal of Central South University》 SCIE EI CAS 2011年第5期1509-1517,共9页
The closed loop control model was built up for compensating the springback and enhancing the work piece precision.A coupled closed loop algorithm and a finite element method were developed to simulate and correct the ... The closed loop control model was built up for compensating the springback and enhancing the work piece precision.A coupled closed loop algorithm and a finite element method were developed to simulate and correct the springback of incremental sheet forming.A three-dimensional finite element model was established for simulation of springback in incremental sheet forming process.The closed loop algorithm of trajectory profile for the incremental sheet forming based on the wavelet transform combined with fast Fourier transform was constructed.The profile of processing tool path of shallow dishing with spherical surface was designed on the basis of the profile correction algorithm.The result shows that the algorithm can predict an ideal profile of processing track,and the springback error of incremental sheet forming is eliminated effectively.It has good convergence efficiency,and can improve the workpiece dimensional accuracy greatly. 展开更多
关键词 闭环算法 板材成形 补偿方法 成形过程 增量表 回弹 模型模拟 尺寸精度
下载PDF
Synthesis identification analysis for closed loop system
18
作者 WANG Jianhong RICARDO A.Ramirez-Mendoza 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2021年第4期939-946,共8页
The existing theories for closed loop identification with the linear feedback controller are very mature.To apply the existed theories directly in the control field,we propose a new idea about replacing the original u... The existing theories for closed loop identification with the linear feedback controller are very mature.To apply the existed theories directly in the control field,we propose a new idea about replacing the original unknown and nonlinear feedback controller with one approximated linear controller,while guaranteeing the equivalent property for the obtained closed loop system.Based on some statistical correlation functions,one condition is derived to show the equivalent property between the approximated linear controller and the original nonlinear controller.The detailed explicit form,corresponding to the approximated linear controller,is also constructed.Furthermore,to give a complete analysis for closed loop identification,the cost function is rewritten as one extended expression,being convenient to understand.Then spectral estimation is introduced to identify the unknown plant in the closed loop system.Finally,the proposed theories are verified by one simulation example. 展开更多
关键词 synthesis analysis closed loop system simplified function equivalent controller
下载PDF
Study the closed loop management system for the coal mines based on risk management
19
作者 LI Xin-chun 《Journal of Coal Science & Engineering(China)》 2010年第2期215-220,共6页
In recent years, the coal safety has been become the urgent problem in China,and severe and fatal coal mine accidents occurred frequently.Must pay attention to coal safety management immediately, because the coal mine... In recent years, the coal safety has been become the urgent problem in China,and severe and fatal coal mine accidents occurred frequently.Must pay attention to coal safety management immediately, because the coal mine accidents not only caused serious economic losses to the country and people but also had negative impact on the society and politics.A closed loop management system was put forward to build to improve the coal safety management.The closed loop management system was formed four parts,identifying the hazard sources, classifying the hidden troubles hazard sources, the risk prealarm and risk control, and the evaluation system. 展开更多
关键词 闭环管理系统 煤矿事故 风险管理 煤矿安全管理 危险源识别 基础 煤炭安全 经济损失
下载PDF
Study on control information network and its real-time property
20
作者 吴转峰 刘卫国 +1 位作者 骆光照 吴浦升 《Journal of Pharmaceutical Analysis》 SCIE CAS 2008年第1期24-32,共9页
The control network is an important developmental orientation in the remote control system. As the control network and information network are comparatively alike in the framework and technology, we can build a contro... The control network is an important developmental orientation in the remote control system. As the control network and information network are comparatively alike in the framework and technology, we can build a control network which is similar to the common information network. In the era when the information network is becoming increasingly mature, it is a royal road to construct or rebuild a control information network in the development of the control network by relying on the achievements made in the information network or current information resources. This paper expounds the construction idea of the control information network, gives the idiographic realization method and then researches into the real-time problem encountered in the control information network, and presents a three-closed-loop control system based on virtualized reality. The feasibility of the idea is validated via experiments and simulations separately. 展开更多
关键词 control information network remote control three-closed-loop system virtualized reality
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部