期刊文献+
共找到254篇文章
< 1 2 13 >
每页显示 20 50 100
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
1
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color Doppler flow imaging aortic regurgitation
下载PDF
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
2
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study 被引量:11
3
作者 Hideyuki Suenaga Huy Hoang Tran +5 位作者 Hongen Liao Ken Masamune Takeyoshi Dohi Kazuto Hoshi Yoshiyuki Mori Tsuyoshi Takato 《International Journal of Oral Science》 SCIE CAS CSCD 2013年第2期98-102,共5页
To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. T... To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (〈1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye. 展开更多
关键词 augmented reality computed tomography integral videography three-dimensional image
下载PDF
Current trends in three-dimensional visualization and real-time navigation as well as robot-assisted technologies in hepatobiliary surgery 被引量:11
4
作者 Yun Wang Di Cao +3 位作者 Si-Lin Chen Yu-Mei Li Yun-Wen Zheng Nobuhiro Ohkohchi 《World Journal of Gastrointestinal Surgery》 SCIE 2021年第9期904-922,共19页
With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary su... With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary surgery,traditional preoperative imaging techniques such as computed tomography and magnetic resonance imaging cannot meet the need for identification of fine anatomical regions.Imaging-based three-dimensional(3D)reconstruction,virtual simulation of surgery and 3D printing optimize the surgical plan through preoperative assessment,improving the controllability and safety of intraoperative operations,and in difficult-to-reach areas of the posterior and superior liver,assistive robots reproduce the surgeon’s natural movements with stable cameras,reducing natural vibrations.Electromagnetic navigation in abdominal surgery solves the problem of conventional surgery still relying on direct visual observation or preoperative image assessment.We summarize and compare these recent trends in digital medical solutions for the future development and refinement of digital medicine in hepatobiliary surgery. 展开更多
关键词 Hepatobiliary surgery three-dimensional visualization three-dimensional printing Electromagnetic tracking real-time navigation Robot-assisted surgery
下载PDF
Real-time Three-dimensional Echocardiographic Assessment of Left Ventricular Remodeling Index in Patients with Hypertensive Heart Disease and Coronary Artery Disease 被引量:15
5
作者 陈明 王静 +5 位作者 谢明星 王新房 吕清 王蕾 李燕 付曼丽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第1期122-126,共5页
Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of ... Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controis (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass/EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P〈0.01). There was no significant difference in NC group (P〉0.05), but significant difference in HHD and CAD intra-group (P〈0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (t=0.69, P〈0.01; r=0.68, P〈0.01), but no significant correlation in CAD group (r=0.30, P〉0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE. 展开更多
关键词 echocardiography real-time three-dimensional left ventricular remodeling index hypertensive heart disease coronary artery disease
下载PDF
A fast and adaptive method for automatic weld defect detection in various real-time X-ray imaging systems 被引量:10
6
作者 邵家鑫 都东 +2 位作者 石涵 常保华 郭桂林 《China Welding》 EI CAS 2012年第1期8-12,共5页
A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of me... A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of median filter is used to estimate the weld background. After the weld background is subtracted from the original image, an adaptite threshold segmentation algorithm is proposed to obtain the binary image, and then the morphological close and open operation, labeling algorithm and fids'e alarm eliminating algorithm are applied to pracess the binary image to obtain the defect, ct detection result. At last, a fast realization procedure jbr proposed method is developed. The proposed method is tested in real-time X-ray image,s obtairted in different X-ray imaging sutems. Experiment results show that the proposed method is effective to detect low contrast weld dejects with few .false alarms and is adaptive to various types of real-time X-ray imaging systems. 展开更多
关键词 non-destructive testing real-time X-ray imaging weld defect automatie detection
下载PDF
REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS 被引量:4
7
作者 Hong-wenFei Xin-fangWang +5 位作者 Ming-xingXie LeiZhuang Li-xinChen Run-qingHuang YingYang JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期230-232,共3页
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto... To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience. 展开更多
关键词 real-time three-dimensional ECHOCARDIOGRAPHY left ventricular mass
下载PDF
Application of Three-Dimensional Magnetic Resonance Imaging in the Diagnosis of Perianal Abscess 被引量:5
8
作者 Fang Zhang Shan Xiong +1 位作者 Sibin Liu Peng Xia 《Health》 2019年第5期535-545,共11页
Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investiga... Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investigate the application of 3.0T MRI 3D CUBE T2WI lipid suppression sequence in the diagnosis of perianal abscess. Methods: Thirty-six patients with perianal abscess confirmed by operation were examined with 2D T2WI and 3D CUBE T2WI lipid suppression sequences before operation. Two imaging techniques were evaluated to show the types of perianal abscess, the number of abscesses, the number of internal orifices of abscess, and the number of fistula branches with anal fistula in abscess. Results: Among 36 cases of perianal abscess, there were 5 cases of anal subcutaneous abscess, 12 cases of ischiorectal space abscess (8 cases complicated with anal fistula), 6 cases of posterior anal space abscess, 5 cases of anal sphincter abscess (3 cases complicated with anal fistula), 2 cases of high intermuscular abscess, 2 cases of rectal submucosal abscess, 3 cases of complex abscess (3 cases complicated with anal fistula), 1 case of misdiagnosis, 2D T2WI lipid suppression sequence and 3D CUBE T2WI suppression. The accuracy of lipid sequence abscess typing was 80.6% (29/36) and 88.9% (32/36), respectively, with no significant difference (P > 0.05). Thirty-six patients were surgically diagnosed as having 32 internal orifices, 68.8% (22/32) and 93.8% (30/32) of 2D T2WI and 3D CUBE T2WI lipid-suppressing sequences, respectively, with significant difference (P Conclusion: 3D CUBE T2WI lipid suppression sequence is superior to 2D T2WI lipid suppression sequence in the classification of perianal abscess, the number of internal orifices of abscess and the number of fistula branches of abscess complicated with anal fistula. It can also determine the number of internal orifices of abscess complicated with anal fistula, the number of fistula branches, the shape of primary and branch fistula and the relationship among pelvic floor muscle tissues. It can provide more accurate images for preoperative and intraoperative clinical surgery. 展开更多
关键词 Magnetic RESONANCE imaging three-dimensional imaging PERIANAL ABSCESS
下载PDF
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
9
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
下载PDF
Real-time three-dimensional echocardiography predicts cardiotoxicity induced by postoperative chemotherapy in breast cancer patients 被引量:3
10
作者 Fang Zhou Lin Niu +2 位作者 Min Zhao Wei-Xing Ni Jian Liu 《World Journal of Clinical Cases》 SCIE 2020年第12期2542-2553,共12页
BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early... BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time. 展开更多
关键词 Atrial volume CHEMOTHERAPY Breast cancer Cardiac toxicity real-time three-dimensional echocardiography ANTHRACYCLINES
下载PDF
QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY 被引量:2
11
作者 Lei Zhuang Ming-xing Xie +2 位作者 Wei-juan Wang Xiang-xin Yang Tao Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第3期135-139,共5页
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed... Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease. 展开更多
关键词 real-time three-dimensional echocardiography CONTRAST perfusion defects myocardial infarction
下载PDF
Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
12
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
下载PDF
Terahertz Three-Dimensional Imaging Based on Computed Tomography with Photonics-Based Noise Source 被引量:4
13
作者 周涛 张戎 +3 位作者 姚辰 符张龙 邵棣祥 曹俊诚 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第8期76-78,共3页
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ... Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications. 展开更多
关键词 THz Terahertz three-dimensional imaging Based on Computed Tomography with Photonics-Based Noise Source
下载PDF
Dynamic Characteristic Mechanism of Atrial Septal Defect Using Real-Time Three-Dimensional Echocardiography and Evaluation of Right Ventricular Functions 被引量:7
14
作者 沙仁高娃 张军 +1 位作者 秦川 吕清 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第1期140-147,共8页
The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynami... The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane(LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group(n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method(4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the right atrial volume occurred in the end-systolic period when the peak of the curve appeared. The minimum value of the changes occurred in the end-systolic period and was located at the lowest point of the volume variation curve. The area variation curve for ASD and the motion variation curve for the tricuspid annulus in the cardiac cycle were the same. The displacement of the tricuspid annulus exhibited directionality. The measured values of the area of ASD at P wave vertex, R wave vertex, T wave starting point, T wave terminal point and in the T-P section were properly correlated with the right atrial volume(P〈0.001). The area of ASD and the motion displacement distance of the tricuspid annulus were negatively correlated(P〈0.05). The right atrial volumes in the ASD group in the cardiac cycle in various time phases increased significantly as compared with those in the normal control group(P=0.0001). The motion displacement distance of the tricuspid annulus decreased significantly in the ASD group as compared with that in the normal control group(P=0.043). The right ventricular ejection fraction in the ASD group was lower than that in the normal control group(P=0.032). The ejection fraction of the cardiac apex trabecula of the ASD patients was significantly lower than the ejection fractions of the right ventricular outflow tract and inflow tract and overall ejection fraction. The difference was statistically significant(P=0.005). The right ventricular local and overall dilatation and end-systolic volumes in the ASD group increased significantly as compared with those in the normal control group(P=0.031). The a RVEF and the overall ejection fraction decreased in the ASD group as compared with those in the normal control group(P=0.0005). The dynamic changes in the area of ASD and the motion curves for the right atrial volume and tricuspid annulus have the same dynamic characteristics. RT 3DE can be used to accurately evaluate the local and overall volume and functions of the right ventricle. The local and overall volume loads of the right ventricle in the ASD patients increase significantly as compared with those of the normal people. The right ventricular cardiac apex and the overall systolic function decrease. 展开更多
关键词 ultrasonic cardiography real-time three-dimension atrial septal defect tricuspid annulus right atrium
下载PDF
Near-Range Large Field-of-View Three-Dimensional Photon-Counting Imaging with a Single-Pixel Si-Avalanche Photodiode 被引量:3
15
作者 Guang-Yue Shen Tian-Xiang Zheng +4 位作者 Bing-Cheng Du Yang Lv E Wu Zhao-Hui Li Guang Wu 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第11期38-41,共4页
Large field-of-view(FoV) three-dimensional(3 D) photon-counting imaging is demonstrated with a single-pixel single-photon detector based on a Geiger-mode Si-avalanche photodiode. By removing the collecting lens(C... Large field-of-view(FoV) three-dimensional(3 D) photon-counting imaging is demonstrated with a single-pixel single-photon detector based on a Geiger-mode Si-avalanche photodiode. By removing the collecting lens(CL)before the detector, the FoV is expanded to ±10°. Thanks to the high detection efficiency, the signal-to-noise ratio of the imaging system is as high as 7.8 dB even without the CL when the average output laser pulse energy is about 0.45 pJ/pulse for imaging the targets at a distance of 5 m. A 3 D image overlaid with the reflectivity data is obtained according to the photon-counting time-of-flight measurement and the return photon intensity. 展开更多
关键词 Near-Range Large Field-of-View three-dimensional Photon-Counting imaging with a Single-Pixel Si-Avalanche Photodiode SI
下载PDF
GPU-accelerated three-dimensional reconstruction method of the Compton camera and its application in radionuclide imaging 被引量:1
16
作者 Ren-Yao Wu Chang-Ran Geng +6 位作者 Feng Tian Zhi-Yang Yao Chun-Hui Gong Hao-Nan Han Jian-Feng Xu Yong-Shun Xiao Xiao-Bin Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第4期54-68,共15页
A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method wit... A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras. 展开更多
关键词 Compton camera three-dimensional reconstruction Radionuclide imaging GPU
下载PDF
Prenatal Diagnosis of Sirenomelia by Two-Dimensional and Three-Dimensional Skeletal Imaging Ultrasound 被引量:1
17
作者 刘蓉 陈欣林 +1 位作者 杨小红 马慧静 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第6期928-931,共4页
Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween Septem... Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia. 展开更多
关键词 SIRENOMELIA three-dimensional skeletal imaging ultrasound three-dimensional helicalcomputed tomography
下载PDF
Continuous imaging space in three-dimensional integral imaging 被引量:1
18
作者 张雷 杨勇 +3 位作者 王金刚 赵星 方志良 袁小聪 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期303-305,共3页
We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into ... We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into real and virtual space. Experimental results show that the gap is reduced to 45% of that in a conventional integral imaging system with the same parameters. 展开更多
关键词 three-dimensional integral imaging imaging space
下载PDF
Three-dimensional time-of-flight magnetic resonance angiography combined with high resolution T2-weighted imaging in preoperative evaluation of microvascular decompression 被引量:2
19
作者 Chen Liang Ling Yang +2 位作者 Bin-Bin Zhang Shi-Wen Guo Rui-Chun Li 《World Journal of Clinical Cases》 SCIE 2022年第34期12594-12604,共11页
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H... BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD. 展开更多
关键词 three-dimensional time-of-flight magnetic resonance angiography High resolution T2 weighted imaging Neurovascular compression Microvascular decompression META-ANALYSIS
下载PDF
Magnetic resonance imaging-three-dimensional printing technology fabricates customized scaffolds for brain tissue engineering 被引量:1
20
作者 Feng Fu Zhe Qin +10 位作者 Chao Xu Xu-yi Chen Rui-xin Li Li-na Wang Ding-wei Peng Hong-tao Sun Yue Tu Chong Chen Sai Zhang Ming-liang Zhao Xiao-hong Li 《Neural Regeneration Research》 SCIE CAS CSCD 2017年第4期614-622,共9页
Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to crea... Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to create customized scaffolds with high precision and accuracy. In this study, an electrically controlled cortical impactor was used to induce randomized brain tissue defects. The overall shape of scaffolds was designed using rat-specific anatomical data obtained from magnetic resonance imaging, and the internal structure was created by computer- aided design. As the result of limitations arising from insufficient resolution of the manufacturing process, we magnified the size of the cavity model prototype five-fold to successfully fabricate customized collagen-chitosan scaffolds using three-dimensional printing. Results demonstrated that scaffolds have three-dimensional porous structures, high porosity, highly specific surface areas, pore connectivity and good internal characteristics. Neural stem cells co-cultured with scaffolds showed good viability, indicating good biocompatibility and biodegradability. This technique may be a promising new strategy for regenerating complex damaged brain tissues, and helps pave the way toward personalized medicine. 展开更多
关键词 nerve regeneration three-dimensional printing traumatic brain injury tissue engineering scaffolds magnetic resonance imaging COLLAGEN CHITOSAN MIMICS neural regeneration
下载PDF
上一页 1 2 13 下一页 到第
使用帮助 返回顶部