Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of ...Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controis (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass/EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P〈0.01). There was no significant difference in NC group (P〉0.05), but significant difference in HHD and CAD intra-group (P〈0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (t=0.69, P〈0.01; r=0.68, P〈0.01), but no significant correlation in CAD group (r=0.30, P〉0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE.展开更多
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto...To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.展开更多
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function...The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function.展开更多
BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early...BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time.展开更多
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed...Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.展开更多
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find...The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.展开更多
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information...Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair.展开更多
In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was pe...In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was performed on 20 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification=l; partial or reduced opaciflcation or subendocardial contrast defect=2; constrast defect=3. Myocardial perfusion score index (MPSI) was calculated by dividing the total sum of contrast score by the total number of segments with abnormal wall motion. Twenty patients were classified into 2 groups according to the MPSI: MPSI≤I.5 as good myocardial perfusion, MPSI〉1.5 as poor myocardial perfusion. To assess the left ventricular remodeling, the following comparisons were carried out: (1) Comparisons of left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) before and 3 months after revascularization in two groups;(2) Comparisons of LVEF, LVESV and LVEDV pre-revascularization between two groups and comparisons of these 3 months post-revascularization between two groups; (3) Comparisons of the differences in LVEF, LVESV and LVEDV between 3 months post-and pre-revascularization (ALVEF, ALVESV and ALVEDV) between two groups; (4) The linear regression analysis between ALVEF, ALVESV, ALVEDV and MPSI. The results showed that the LVEF obtained 3 months after revascularization in patients with MPSI〉1.5 was obviously lower than that in those with MPSI〈1.5. The LVEDV obtained 3 months post-revascularization in patients with MPSI〉1.5 was obviously larger than that in those with MPSI≤1.5 (P=0.002 and 0.04). The differences in ALVEF and ALVEDV between patients with MPSI〉I.5 and those with MPSI≤1.5 were significant (P=0.002 and 0.001, respectively). Linear regression analysis revealed that MPSI had a negative correlation with ALVEF and a positive correlation with ALVESV, ALVEDV (P=0.004, 0.008, and 0.016, respectively). It was concluded that RT-MCE could accurately evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization.展开更多
To evaluate the feasibility of real-time myocardial contrast echocardiography (RTMCE) by quantitative analysis of myocardial perfusion in rabbits, transthoracic RTMCE was performed in 10 healthy rabbits by using con...To evaluate the feasibility of real-time myocardial contrast echocardiography (RTMCE) by quantitative analysis of myocardial perfusion in rabbits, transthoracic RTMCE was performed in 10 healthy rabbits by using continuous infusion of SonoVue into the auricular vein. The short axis view at the papillary muscle level was obtained. The duration of the time that the contrast took to appear in right heart, left heart and myocardium was recorded. The regional myocardial signal intensity (SI) versus re-filling time plots were fitted to an exponential function: y(t) =A(1–e–β(t–t0)) + C, where y is SI at any given time, A is the SI plateau that reflects myocardial blood volume, and β is the slope of the refilling curve that reflects myocardial microbubble velocity. The A, β and A×β values at different infusion rate of SonoVue were analyzed and the A, β and A×β values in each segment in the short axis view at the papillary muscle level were compared. All the animal experiments were successful and high-quality im-ages were obtained. The best intravenous infusion rate for SonoVue was 30 mL/h. The contrast appeared in right heart, left heart and myocardium at 7.5±2.2 s, 9.1±2.4 s and 12.2±1.6 s respectively. After 16.6±2.3s, myocardial opacification reached a steady state. The mean A, β and A×β value in the short axis view at the papillary muscle level were 9.8±3.0 dB, 1.4±0.5 s-1 and 13.5±3.6 dB×s-1 respectively. A, β and A×β values showed no significant differences among 6 segments. It was suggested that RTMCE was feasible for quantitative analysis of myocardial perfusion in rabbits. It provides a non-invasive method to evaluate the myocardial perfusion in rabbit disease models.展开更多
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp...The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.展开更多
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method...Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated.展开更多
Objective To investigate the surgical technique and outcomes of replacement of chordae tendineae in mitral valve repair,and evaluate the value of real-time three-di-mensional transesophageal echocardiography in the pe...Objective To investigate the surgical technique and outcomes of replacement of chordae tendineae in mitral valve repair,and evaluate the value of real-time three-di-mensional transesophageal echocardiography in the perioperative period. Methods Thirty-one patients with mitral valve prolapse underwent mitral valve repair using chordae tendineae replacement concomitant with implantation展开更多
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT...The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.展开更多
AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasou...AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasound image in real time by merging the ultrasound image with a multiplanar reconstruction computed tomography(CT)image,using pre-scanned CT volume data.The ultrasound used was EUB-8500with a convex probe EUP-C514.The RVS images were evaluated based on 3 levels,namely,excellent,good and poor,by the displacement in position.RESULTS:By combining the objectivity of CT with free scanning using RVS,it was possible to easily interpret the relationship between lesions and the surrounding organs as well as the position of vascular structures.The resulting evaluation levels of the RVS images were12 excellent(pancreatic cancer,bile duct cancer,cholecystolithiasis and cholangiocellular carcinoma)and 3 good(pancreatic cancer and gallbladder cancer).Compared with conventional B-mode ultrasonography and CT,RVS images achieved a rate of 80%superior visualization and 20%better visualization.CONCLUSION:RVS has potential usefulness in objective visualization and diagnosis in the field of biliary and pancreatic diseases.展开更多
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso...BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS.展开更多
The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfuncti...The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfunction was defined by E'〈A' in pulse-wave tissue Doppler for inter-ventricular septal (IVS) of mitral annulus. In 24 patients with LV diastolic dysfunction, including 12 patients with delayed relaxation (delayed relaxation group) and 12 patients with pseudo-normal function (pseudo-normal group) and 24 normal volunteers (control group), data of full-volume image were acquired by real-time three-dimensional echocardiography and subjected to volume-time curve analysis. EDV (end-diastolic volume), ESV (end-systolic volume), LVEF (left ventricular ejection fraction), PER (peak ejection rate), PFR (peak filling rate) from RT3DE were examined in the three groups. Compared to the control group, PFR (diastolic filling index of RT3DE) was significantly reduced in the delayed relaxation group and pseudo-normal group (P〈0.05). There were no significant differences in EDV, ESV, LVEE PER (P〉0.05). It is concluded that PFR, as a diastolic filling index of RT3DE, can reflect the early diastolic function and serve as a new non-invasive, quick and accurate tool for clinical assessment of LV diastolic function.展开更多
Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE...Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE to evaluate the changes in biventricular volume and systolic function in children with ventricular septaldefect (VSD) and moderate to severe pulmonary hypertension (PH) before surgery. Methods: In this study18 children with VSD and moderate to severe PH (VSD + PH Group) and 18 healthy children of the sameage (Control Group) were recruited. Biventricular volume and systolic function were evaluated by RT-3DE.The measurements included: left and right ventricular volume indexed to body surface area (BSA), stroke volume(SV) indexed to BSA, and ejection fraction (EF). Results: The results showed left and right ventricular volumeindexed to BSA and SV indexed to BSA were significantly increased in VSD + PH Group (VSD + PH Groupvs. Control Group), LVEDV/BSA (ml/m2): 48.67 ± 21.46 vs. 25.59 ± 6.96, RVEDV/BSA (ml/m2): 55.98 ±15.35 vs. 27.69 ± 4.37, LVSV/BSA (ml/m2): 24.08 ± 9.30 vs. 15.14 ± 4.29, RVSV/BSA (ml/m2): 26.02 ± 8.87 vs.14.11 ± 2.89, (P < 0.05). While for EF in VSD + PH Group decreased (VSD + PH Group vs. Control Group),LVEF: 50.93 ± 7.50% vs. 59.38 ± 7.24%, RVEF: 45.84 ± 7.71% vs. 51.05 ± 6.90% (P < 0.05). Conclusion: Inchildren with VSD and moderate to severe PH, increased biventricular volume and decreased systolic functionwere observed with RT-3DE, but biventricular systolic function remained within acceptable limits. The childrenin this study recovered well after surgery without serious perioperative complications, suggesting that biventricularsystolic function may help facilitate the surgical decision-making process in children with VSD and moderate-toseverePH.展开更多
AIM To establish a modified B-ultrasound method of measuring the antral section only to assess gastric motility in healthy people,and evaluate its application in guiding enteral nutrition(EN) in critically ill patient...AIM To establish a modified B-ultrasound method of measuring the antral section only to assess gastric motility in healthy people,and evaluate its application in guiding enteral nutrition(EN) in critically ill patients. METHODS First,30 healthy volunteers were selected. The modified B-ultrasound method and the traditional B-ultrasound method were applied to assess gastric function. The correlation of indices of gastric function between the two groups was analyzed statistically. In addition,64 critically ill patients were selected,and the modified B-ultrasound method and the gastric juice withdrawal method were applied to guide the implementation of EN. Daily caloric value,the time required to achieve complete EN,ICU stay,hospitalization time,and serum prealbumin and albumin levels were recorded and compared between the two groups. Kaplan-Meier survival curve was used to compare the complications of EN between the two groups. RESULTS In healthy subjects,there was a good correlation among gastric emptying time,antral contraction frequency andantral motility index between the two groups(r = 0.57,0.61 and 0.54,respectively). The study on critically ill patients also revealed that a better effect of EN was achieved in the modified B-ultrasound method group,in which patients had shorter ICU stay and hospitalization time and higher levels of serum prealbumin and albumin. The Kaplan-Meier survival analysis revealed that the improved B-ultrasound method was associated with significantly fewer EN complications(P = 0.031).CONCLUSION The modified B-ultrasound method can provide a good real-time assessment of gastric function and has a better effect than the traditional method in guiding EN in critically ill patients.展开更多
Emergency physicians are required to care for unstable patients with life-threatening conditions, and thus must make decisions that are both quick and precise about unclear clinical situations. There is increasing con...Emergency physicians are required to care for unstable patients with life-threatening conditions, and thus must make decisions that are both quick and precise about unclear clinical situations. There is increasing consensus in favor of using ultrasound as a real-time bedside clinical tool for clinicians in emergency settings alongside the irreplaceable use of historical and physical examinations. B-mode sonography is an old technology that was first proposed for medical applications more than 50 years ago. Its application in the diagnosis of thoracic diseases has always been considered limited, due to the presence of air in the lung and the presence of the bones of the thoracic cage, which prevent the progression of the ultrasound beam. However, the close relationship between air and water in the lungs causes a variety of artifacts on ultrasounds. At the bedside, thoracic ultrasound is based primarily on the analysis of these artifacts, with the aim of improving accuracy and safety in the diagnosis and therapy of the various varieties of pulmonary pathologic diseases which are predominantly "water-rich" or "air-rich". The indications, contraindications, advantages, disadvantages, and techniques of thoracic ultrasound and its related procedures are analyzed in the present review.展开更多
Endoscopic ultrasound (EUS) has recently evolved through technological improvement of equipment,with a major clinical impact in digestive and mediastinal diseases.State-of-the-art EUS equipment now includes real-time ...Endoscopic ultrasound (EUS) has recently evolved through technological improvement of equipment,with a major clinical impact in digestive and mediastinal diseases.State-of-the-art EUS equipment now includes real-time sono-elastography,which might be useful for a better characterization of lesions and increased accuracy of differential diagnosis (for e.g.lymph nodes or focal pancreatic lesions).Contrast-enhanced EUS imaging is also available,and is already being used for the differential diagnosis of focal pancreatic masses.The recent development of low mechanical index contrast harmonic EUS imaging offers hope for improved diagnosis,staging and monitoring of anti-angiogenic treatment.Tridimensional EUS (3D-EUS) techniques can be applied to enhance the spatial understanding of EUS anatomy,especially for improved staging of tumors,obtained through a better assessment of the relationship with major surrounding vessels.Despite the progress gained through all these imaging techniques,they cannot replace cytological or histological diagnosis.However,real-time optical histological diagnosis can be achieved through the use of single-fiber confocal laser endomicroscopy techniques placed under real-time EUS-guidance through a 22G needle.Last,but not least,EUS-assisted natural orifice transluminal endoscopic surgery (NOTES) procedures offer a whole new area of imaging applications,used either for combination of NOTES peritoneoscopy and intraperitoneal EUS,but also for access of retroperitoneal organs through posterior EUS guidance.展开更多
文摘Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controis (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass/EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P〈0.01). There was no significant difference in NC group (P〉0.05), but significant difference in HHD and CAD intra-group (P〈0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (t=0.69, P〈0.01; r=0.68, P〈0.01), but no significant correlation in CAD group (r=0.30, P〉0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE.
文摘To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.
文摘The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function.
基金Supported by Medical and Health Foundation Project of Zhejiang Province,China,No.2020KY690Natural Science Foundation of Zhejiang Province,China,No.LGF20H020004.
文摘BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time.
文摘Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.
基金supported by a grant from the Youth Science Foundation of China (No.30600213)
文摘The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.
文摘Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair.
文摘In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was performed on 20 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification=l; partial or reduced opaciflcation or subendocardial contrast defect=2; constrast defect=3. Myocardial perfusion score index (MPSI) was calculated by dividing the total sum of contrast score by the total number of segments with abnormal wall motion. Twenty patients were classified into 2 groups according to the MPSI: MPSI≤I.5 as good myocardial perfusion, MPSI〉1.5 as poor myocardial perfusion. To assess the left ventricular remodeling, the following comparisons were carried out: (1) Comparisons of left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) before and 3 months after revascularization in two groups;(2) Comparisons of LVEF, LVESV and LVEDV pre-revascularization between two groups and comparisons of these 3 months post-revascularization between two groups; (3) Comparisons of the differences in LVEF, LVESV and LVEDV between 3 months post-and pre-revascularization (ALVEF, ALVESV and ALVEDV) between two groups; (4) The linear regression analysis between ALVEF, ALVESV, ALVEDV and MPSI. The results showed that the LVEF obtained 3 months after revascularization in patients with MPSI〉1.5 was obviously lower than that in those with MPSI〈1.5. The LVEDV obtained 3 months post-revascularization in patients with MPSI〉1.5 was obviously larger than that in those with MPSI≤1.5 (P=0.002 and 0.04). The differences in ALVEF and ALVEDV between patients with MPSI〉I.5 and those with MPSI≤1.5 were significant (P=0.002 and 0.001, respectively). Linear regression analysis revealed that MPSI had a negative correlation with ALVEF and a positive correlation with ALVESV, ALVEDV (P=0.004, 0.008, and 0.016, respectively). It was concluded that RT-MCE could accurately evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization.
文摘To evaluate the feasibility of real-time myocardial contrast echocardiography (RTMCE) by quantitative analysis of myocardial perfusion in rabbits, transthoracic RTMCE was performed in 10 healthy rabbits by using continuous infusion of SonoVue into the auricular vein. The short axis view at the papillary muscle level was obtained. The duration of the time that the contrast took to appear in right heart, left heart and myocardium was recorded. The regional myocardial signal intensity (SI) versus re-filling time plots were fitted to an exponential function: y(t) =A(1–e–β(t–t0)) + C, where y is SI at any given time, A is the SI plateau that reflects myocardial blood volume, and β is the slope of the refilling curve that reflects myocardial microbubble velocity. The A, β and A×β values at different infusion rate of SonoVue were analyzed and the A, β and A×β values in each segment in the short axis view at the papillary muscle level were compared. All the animal experiments were successful and high-quality im-ages were obtained. The best intravenous infusion rate for SonoVue was 30 mL/h. The contrast appeared in right heart, left heart and myocardium at 7.5±2.2 s, 9.1±2.4 s and 12.2±1.6 s respectively. After 16.6±2.3s, myocardial opacification reached a steady state. The mean A, β and A×β value in the short axis view at the papillary muscle level were 9.8±3.0 dB, 1.4±0.5 s-1 and 13.5±3.6 dB×s-1 respectively. A, β and A×β values showed no significant differences among 6 segments. It was suggested that RTMCE was feasible for quantitative analysis of myocardial perfusion in rabbits. It provides a non-invasive method to evaluate the myocardial perfusion in rabbit disease models.
文摘The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.
文摘Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated.
文摘Objective To investigate the surgical technique and outcomes of replacement of chordae tendineae in mitral valve repair,and evaluate the value of real-time three-di-mensional transesophageal echocardiography in the perioperative period. Methods Thirty-one patients with mitral valve prolapse underwent mitral valve repair using chordae tendineae replacement concomitant with implantation
文摘The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.
文摘AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasound image in real time by merging the ultrasound image with a multiplanar reconstruction computed tomography(CT)image,using pre-scanned CT volume data.The ultrasound used was EUB-8500with a convex probe EUP-C514.The RVS images were evaluated based on 3 levels,namely,excellent,good and poor,by the displacement in position.RESULTS:By combining the objectivity of CT with free scanning using RVS,it was possible to easily interpret the relationship between lesions and the surrounding organs as well as the position of vascular structures.The resulting evaluation levels of the RVS images were12 excellent(pancreatic cancer,bile duct cancer,cholecystolithiasis and cholangiocellular carcinoma)and 3 good(pancreatic cancer and gallbladder cancer).Compared with conventional B-mode ultrasonography and CT,RVS images achieved a rate of 80%superior visualization and 20%better visualization.CONCLUSION:RVS has potential usefulness in objective visualization and diagnosis in the field of biliary and pancreatic diseases.
基金Supported by the National Natural Science Foundation of China,No.82305380The Postdoctoral Research Program,West China Hospital,Sichuan University,No.2020HXBH018.
文摘BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS.
基金This project was supported by a grant from Guangdong Provincial Natural Sciences Foundation (No 05300738)
文摘The volume-time curve change in patients with normal left ventricular (LV) diastolic function and diastolic dysfunction was evaluated by real-time three-dimensional echocardiography (RT3DE). LV diastolic dysfunction was defined by E'〈A' in pulse-wave tissue Doppler for inter-ventricular septal (IVS) of mitral annulus. In 24 patients with LV diastolic dysfunction, including 12 patients with delayed relaxation (delayed relaxation group) and 12 patients with pseudo-normal function (pseudo-normal group) and 24 normal volunteers (control group), data of full-volume image were acquired by real-time three-dimensional echocardiography and subjected to volume-time curve analysis. EDV (end-diastolic volume), ESV (end-systolic volume), LVEF (left ventricular ejection fraction), PER (peak ejection rate), PFR (peak filling rate) from RT3DE were examined in the three groups. Compared to the control group, PFR (diastolic filling index of RT3DE) was significantly reduced in the delayed relaxation group and pseudo-normal group (P〈0.05). There were no significant differences in EDV, ESV, LVEE PER (P〉0.05). It is concluded that PFR, as a diastolic filling index of RT3DE, can reflect the early diastolic function and serve as a new non-invasive, quick and accurate tool for clinical assessment of LV diastolic function.
基金Wuhan Health and Family Planning Commission Grant/Award(WX16D18).
文摘Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE to evaluate the changes in biventricular volume and systolic function in children with ventricular septaldefect (VSD) and moderate to severe pulmonary hypertension (PH) before surgery. Methods: In this study18 children with VSD and moderate to severe PH (VSD + PH Group) and 18 healthy children of the sameage (Control Group) were recruited. Biventricular volume and systolic function were evaluated by RT-3DE.The measurements included: left and right ventricular volume indexed to body surface area (BSA), stroke volume(SV) indexed to BSA, and ejection fraction (EF). Results: The results showed left and right ventricular volumeindexed to BSA and SV indexed to BSA were significantly increased in VSD + PH Group (VSD + PH Groupvs. Control Group), LVEDV/BSA (ml/m2): 48.67 ± 21.46 vs. 25.59 ± 6.96, RVEDV/BSA (ml/m2): 55.98 ±15.35 vs. 27.69 ± 4.37, LVSV/BSA (ml/m2): 24.08 ± 9.30 vs. 15.14 ± 4.29, RVSV/BSA (ml/m2): 26.02 ± 8.87 vs.14.11 ± 2.89, (P < 0.05). While for EF in VSD + PH Group decreased (VSD + PH Group vs. Control Group),LVEF: 50.93 ± 7.50% vs. 59.38 ± 7.24%, RVEF: 45.84 ± 7.71% vs. 51.05 ± 6.90% (P < 0.05). Conclusion: Inchildren with VSD and moderate to severe PH, increased biventricular volume and decreased systolic functionwere observed with RT-3DE, but biventricular systolic function remained within acceptable limits. The childrenin this study recovered well after surgery without serious perioperative complications, suggesting that biventricularsystolic function may help facilitate the surgical decision-making process in children with VSD and moderate-toseverePH.
基金Supported by Cangzhou Science and Technology Project,No.131302097
文摘AIM To establish a modified B-ultrasound method of measuring the antral section only to assess gastric motility in healthy people,and evaluate its application in guiding enteral nutrition(EN) in critically ill patients. METHODS First,30 healthy volunteers were selected. The modified B-ultrasound method and the traditional B-ultrasound method were applied to assess gastric function. The correlation of indices of gastric function between the two groups was analyzed statistically. In addition,64 critically ill patients were selected,and the modified B-ultrasound method and the gastric juice withdrawal method were applied to guide the implementation of EN. Daily caloric value,the time required to achieve complete EN,ICU stay,hospitalization time,and serum prealbumin and albumin levels were recorded and compared between the two groups. Kaplan-Meier survival curve was used to compare the complications of EN between the two groups. RESULTS In healthy subjects,there was a good correlation among gastric emptying time,antral contraction frequency andantral motility index between the two groups(r = 0.57,0.61 and 0.54,respectively). The study on critically ill patients also revealed that a better effect of EN was achieved in the modified B-ultrasound method group,in which patients had shorter ICU stay and hospitalization time and higher levels of serum prealbumin and albumin. The Kaplan-Meier survival analysis revealed that the improved B-ultrasound method was associated with significantly fewer EN complications(P = 0.031).CONCLUSION The modified B-ultrasound method can provide a good real-time assessment of gastric function and has a better effect than the traditional method in guiding EN in critically ill patients.
文摘Emergency physicians are required to care for unstable patients with life-threatening conditions, and thus must make decisions that are both quick and precise about unclear clinical situations. There is increasing consensus in favor of using ultrasound as a real-time bedside clinical tool for clinicians in emergency settings alongside the irreplaceable use of historical and physical examinations. B-mode sonography is an old technology that was first proposed for medical applications more than 50 years ago. Its application in the diagnosis of thoracic diseases has always been considered limited, due to the presence of air in the lung and the presence of the bones of the thoracic cage, which prevent the progression of the ultrasound beam. However, the close relationship between air and water in the lungs causes a variety of artifacts on ultrasounds. At the bedside, thoracic ultrasound is based primarily on the analysis of these artifacts, with the aim of improving accuracy and safety in the diagnosis and therapy of the various varieties of pulmonary pathologic diseases which are predominantly "water-rich" or "air-rich". The indications, contraindications, advantages, disadvantages, and techniques of thoracic ultrasound and its related procedures are analyzed in the present review.
基金Supported by "Utility of EUS and OCT for the minimal invasive evaluation of tumour neo-angiogenesis in the patients with digestive cancers" financed by the Romanian Ministry of Educationand Research-National University Research Council UEFISCSU-Ideas Program, No.239/2007
文摘Endoscopic ultrasound (EUS) has recently evolved through technological improvement of equipment,with a major clinical impact in digestive and mediastinal diseases.State-of-the-art EUS equipment now includes real-time sono-elastography,which might be useful for a better characterization of lesions and increased accuracy of differential diagnosis (for e.g.lymph nodes or focal pancreatic lesions).Contrast-enhanced EUS imaging is also available,and is already being used for the differential diagnosis of focal pancreatic masses.The recent development of low mechanical index contrast harmonic EUS imaging offers hope for improved diagnosis,staging and monitoring of anti-angiogenic treatment.Tridimensional EUS (3D-EUS) techniques can be applied to enhance the spatial understanding of EUS anatomy,especially for improved staging of tumors,obtained through a better assessment of the relationship with major surrounding vessels.Despite the progress gained through all these imaging techniques,they cannot replace cytological or histological diagnosis.However,real-time optical histological diagnosis can be achieved through the use of single-fiber confocal laser endomicroscopy techniques placed under real-time EUS-guidance through a 22G needle.Last,but not least,EUS-assisted natural orifice transluminal endoscopic surgery (NOTES) procedures offer a whole new area of imaging applications,used either for combination of NOTES peritoneoscopy and intraperitoneal EUS,but also for access of retroperitoneal organs through posterior EUS guidance.