According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th...According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.展开更多
This paper reports that a series of silver oxide (AgzO) films are deposited on glass substrates by direct-current reactive magnetron sputtering at a substrate temperature of 250 ℃ and an oxygen flux ratio of 15:18...This paper reports that a series of silver oxide (AgzO) films are deposited on glass substrates by direct-current reactive magnetron sputtering at a substrate temperature of 250 ℃ and an oxygen flux ratio of 15:18 by modifying the sputtering power (SP). The AgxO films deposited apparently show a structural evolution from cubic biphased (AgO + Ag20) to cubic single-phased (Ag20), and to biphased (Ag20 + AgO) structure. Notably, the cubic single-phased Ag20 fihn is deposited at the SP = 105 W and an AgO phase with (220) orientation discerned in the Ag^O films deposited using the SP 〉 105 W. The transmissivity and refiectivity of the AgxO films in transparent region decrease with the increase the SP, whereas the absorptivity inversely increases with the increase of the SP. These results may be due to the structural evolution and the increasing film thickness. A redshift of the films' absorption edges determined in terms of Tauc formula clearly occurs from 3.1 eV to 2.73 eV with the increase of the SP.展开更多
高压直流(high voltage direct current,HVDC)换流器具有一定的动态无功调节能力,充分利用换流站的无功调节能力,可显著改善HVDC系统的稳定性能。文中研究了HVDC系统稳态运行时的无功功率可调节能力,分析了有功功率和无功功率相互耦合...高压直流(high voltage direct current,HVDC)换流器具有一定的动态无功调节能力,充分利用换流站的无功调节能力,可显著改善HVDC系统的稳定性能。文中研究了HVDC系统稳态运行时的无功功率可调节能力,分析了有功功率和无功功率相互耦合的特性,以国际大电网(conference International des grands reseaux electriques,CIGRE)的HVDC标准测试模型和贵广Ⅱ直流输电工程模型为算例,对稳态工况的直流电流可运行范围进行了解析,进而求出整流、逆变两侧的无功功率可调节能力,并将其应用在无功控制中。研究发现,CIGRE的HVDC标准测试模型对于容性的无功功率和感性的无功功率调节能力相近,而贵广Ⅱ直流输电工程模型对感性无功的调节能力远大于对容性无功的调节能力。在电磁暂态仿真程序PSCAD/EMTDC中验证了无功功率可调节能力的正确性和应用价值。展开更多
For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act...For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.展开更多
文摘According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.
基金supported by the National Natural Science Foundation of China (Grant No. 60807001)the National Basic Research Program of China (Grant No. 2011CB201605)the Foundation of Henan Educational Committee (Grant No. 2010A140017)
文摘This paper reports that a series of silver oxide (AgzO) films are deposited on glass substrates by direct-current reactive magnetron sputtering at a substrate temperature of 250 ℃ and an oxygen flux ratio of 15:18 by modifying the sputtering power (SP). The AgxO films deposited apparently show a structural evolution from cubic biphased (AgO + Ag20) to cubic single-phased (Ag20), and to biphased (Ag20 + AgO) structure. Notably, the cubic single-phased Ag20 fihn is deposited at the SP = 105 W and an AgO phase with (220) orientation discerned in the Ag^O films deposited using the SP 〉 105 W. The transmissivity and refiectivity of the AgxO films in transparent region decrease with the increase the SP, whereas the absorptivity inversely increases with the increase of the SP. These results may be due to the structural evolution and the increasing film thickness. A redshift of the films' absorption edges determined in terms of Tauc formula clearly occurs from 3.1 eV to 2.73 eV with the increase of the SP.
文摘高压直流(high voltage direct current,HVDC)换流器具有一定的动态无功调节能力,充分利用换流站的无功调节能力,可显著改善HVDC系统的稳定性能。文中研究了HVDC系统稳态运行时的无功功率可调节能力,分析了有功功率和无功功率相互耦合的特性,以国际大电网(conference International des grands reseaux electriques,CIGRE)的HVDC标准测试模型和贵广Ⅱ直流输电工程模型为算例,对稳态工况的直流电流可运行范围进行了解析,进而求出整流、逆变两侧的无功功率可调节能力,并将其应用在无功控制中。研究发现,CIGRE的HVDC标准测试模型对于容性的无功功率和感性的无功功率调节能力相近,而贵广Ⅱ直流输电工程模型对感性无功的调节能力远大于对容性无功的调节能力。在电磁暂态仿真程序PSCAD/EMTDC中验证了无功功率可调节能力的正确性和应用价值。
文摘For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.