Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are...Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are frequency-dependent and unchangeable.Here,we present a reconfigurable 2D mechanism-based metamaterial which possesses transformable and frequency-independent elastic properties.Based on the proposed mechanism-based metamaterial,interesting functionalities,such as ternarycoded elastic wave polarizer and programmable refraction,are demonstrated.Particularly,unique ternary-coded polarizers,with 1-trit polarization filtering and 2-trit polarization separating of longitudinal and transverse waves,are first achieved.Then,the strong anisotropy of the proposed metamaterial is harnessed to realize positive-negative bi-refraction,only-positive refraction,and only-negative refraction.Finally,the wave functions with detailed microstructures are numerically verified.展开更多
Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE...Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE source using refraction path is proposed.Firstly,the control equation of the refraction path is established according to the sensor coordinates and arrival times.Secondly,considering the influence of time-difference-of-arrival(TDOA)errors,the residual of the governing equation is calculated to estimate the equation weight.Thirdly,the refraction points in different directions are solved using Snell’s law and orthogonal constraints.Finally,the source coordinates are iteratively solved by weighted correction terms.The feasibility and accuracy of the proposed method are verified by pencil-lead breaking experiments.The simulation results show that the new method is almost unaffected by the refraction ratio,and always holds more stable and accurate positioning performance than the traditional method under different ratios and scales of TDOA outliers.展开更多
AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 e...AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 emmetropia(E),429 low myopia(LM),80 moderate myopia(MM),and 32 low hypermetropia(LH)]aged 10 to 13y were analyzed.RPRs were measured using MRT without mydriasis.MRT results showed RPR at 0-15°(RPR 0-15),15°-30°(RPR 15-30),and 30°-45°(RPR 30-45)annular in the inferior(RPR-I),superior(RPR-S),nasal(RPR-N),and temporal(RPR-T)quadrants.Spherical equivalent(SE)was detected and calculated using an autorefractor.RESULTS:There were significant differences of RPR 15-30 between groups MM[0.02(-0.12;0.18)]and LH[-0.13(-0.36;0.12)](P<0.05),MM and E[-0.06(-0.20;0.10)](P<0.05),and LM[-0.02(-0.15;0.15)]and E(P<0.05).There were also significant differences of RPR 30-45 between groups MM[0.45(0.18;0.74)]and E[0.29(-0.09;0.67)](P<0.05),and LM[0.44(0.14;0.76)]and E(P<0.001).RPR values increased from the hyperopic to medium myopic group in each annular.There were significant differences of RPR-S between groups MM[-0.02(-0.60;0.30)]and E[-0.44(-0.89;-0.04)](P<0.001),and LM[-0.28(-0.71;0.12)]and E(P<0.05).There were also significant differences of RPR-T between groups MM[0.37(0.21;0.78)]and LH[0.14(-0.52;0.50)](P<0.05),LM[0.41(0.06;0.84)]and LH(P<0.05),and LM and E[0.29(-0.10;0.68),P<0.05].A Spearman’s correlation analysis showed a negative correlation between RPR and SE in the 15°-30°(P=0.005),30°-45°(P<0.05)annular(P=0.002),superior(P<0.001),and temporal(P=0.001)quadrants.CONCLUSION:Without pupil dilation,values for RPR 15-30,30-45,RPR-S,and T shows significant differences between myopic eyes and emmetropia,and the differences are negatively correlated with SE.展开更多
AIM:To investigate the differences in retinal refraction difference values(RDVs)of adult patients with myopic anisometropia compared with those without myopic anisometropia,and to investigate the relationship between ...AIM:To investigate the differences in retinal refraction difference values(RDVs)of adult patients with myopic anisometropia compared with those without myopic anisometropia,and to investigate the relationship between ocular biometric measurements and relative peripheral refraction.METHODS:This clinical observation study included 130 patients with myopia(-0.25 to-10.00 D)between October 2022 and January 2023 aged between 18 and 40y.The patients were divided into anisometropia(n=63;difference in binocular anisometropia≥1.00 D)and non-anisometropia(n=67;difference in binocular anisometropia<1.00 D)groups accordingly.Ocular biometric measurements were performed by optical biometrics and corneal topography to assess the steep keratometry(Ks),flap keratometry(Kf),axial length(AL),corneal astigmatism(CYL;Ks-Kf),surface regularity index(SRI),surface asymmetry index(SAI),and central corneal thickness(CCT).The RDV was measured at five retinal areas from the fovea to 53 degrees(RDV-0-10,RDV-10-20,RDV-20-30,RDV-30-40,and RDV-40-53),the total RDV(TRDV)of 53 degrees,and four regions,including RDV-superior,RDV-inferior,RDV-temporal,and RDV-nasal.An analysis of Spearman correlation was carried out to examine the correlation between RDV and the spherical equivalent(SE)and ocular biological parameters.RESULTS:Within RDV-20-53,both groups showed relative hyperopic defocus,and the increase in RDV corresponds to the increase in eccentricity.In the myopic anisometropia group,the TRDV,RDV-20-53,RDV-superior,and more myopic eyes had significantly higher RDVtemporal values than less myopic eyes.(P<0.05).In the non-anisometropia group,there was no significant difference in the RDV between the more and less myopic eyes at different eccentricities(P>0.05).There was a negative correlation between SE and TRDV(r=-0.205,P=0.001),RDV-20-53(r=-0.281,-0.183,-0.176,P<0.05),RDV-superior(r=-0.251,P<0.001),and RDV-temporal(r=-0.230,P<0.001),a negative correlation between CYL and RDV-10-30(r=-0.147,-0.180,P<0.05),and a negative correlation between SRI and RDV-0-20(r=-0.190,-0.170,P<0.05).AL had a positive correlation with RDV-20-30(r=0.164,P=0.008)and RDV-temporal(r=0.160,P=0.010).CONCLUSION:More myopic eyes in patients with myopic anisometropia show more peripheral hyperopic defocus.Diopter and corneal morphology may affect peripheral retinal defocus.展开更多
We investigate the electromagnetic properties of a four-level dense atomic gas medium with Doppler effect.It is shown that the relative permittivity and relative permeability of the medium can be negative simultaneous...We investigate the electromagnetic properties of a four-level dense atomic gas medium with Doppler effect.It is shown that the relative permittivity and relative permeability of the medium can be negative simultaneously with low absorption in the same detuning interval on account of electromagnetically induced transparency.Furthermore,with the suitable parameters,the nonreciprocal negative refraction can be obtained due to the Doppler effect,and the nonreciprocity frequency band can be regulated by adjusting the temperature,the intensity of the control field and the atomic density in this hot atomic medium.展开更多
AIM:To compare the subjective refraction data with non-cycloplegic auto-refraction findings in the geriatric population above 60 years of age according to the different crystalline lens conditions.METHODS:This report ...AIM:To compare the subjective refraction data with non-cycloplegic auto-refraction findings in the geriatric population above 60 years of age according to the different crystalline lens conditions.METHODS:This report is a part of the Tehran Geriatric Eye Study(TGES)that was conducted from January 2019 to January 2020 on elderly population 60 years of age and above in Tehran.The samples were selected by multistage stratified random cluster sampling.Of 3791 individual invitees,3310(response rate:87.3%)participated in this study.All study participants underwent non-cycloplegic autorefraction(auto-refractometer/keratometer Nidek ARK-510)and subjective refraction.RESULTS:Regarding the sphere,eyes with mixed cataract had the worst limits of agreement(LoA:-1.24 to 0.87)and the best agreement was related to the pseudophakic eyes(LoA:-0.83 to 0.54).The highest(0.27±0.31 D)and lowest(0.21±0.27 D)differences between the two methods regarding the cylinder power were observed in eyes with cortical cataract and normal eyes,respectively.The worst LoA between the two methods in measuring the cylinder power was related to the eyes with mixed cataract(LoA:-0.44 to 0.96).Regarding the J0(horizontal/vertical components of astigmatism),the mean values of J0 obtained by auto-refraction were tended more toward against the rule direction in all crystalline lens conditions,and the two methods had the greatest difference in cortical cataract cases(0.05±0.17 D).Regarding the J45(oblique components of astigmatism),the lowest(0±0.11 D)and highest(-0.01±0.12 D)differences were observed in normal eyes and eyes with cortical cataract,respectively.CONCLUSION:The auto-refractometer/keratometer Nidek ARK-510 results in the elderly with different phakic and pseudophakic conditions do not correspond well with subjective refraction findings.This discrepancy in spherical findings is more pronounced in individuals with mixed cataract than in other cases.展开更多
We demonstrate a method to realize unidirectional negative refraction in an acoustic parity-time(P T)-symmetric system, which is composed of a pair of metasurfaces sandwiching an air gap. The pair of metasurfaces poss...We demonstrate a method to realize unidirectional negative refraction in an acoustic parity-time(P T)-symmetric system, which is composed of a pair of metasurfaces sandwiching an air gap. The pair of metasurfaces possesses loss and gain modulations. The unidirectional negative refraction, which is strictly limited to the case of incident wave imposing on the loss end of the metasurface, is demonstrated at the exception point(EP) in this P T-symmetric system, while the incidence from the other side leads to strong reflection. Based on rigorous calculations, we explicitly show the underlying mechanism of this model to achieve unidirectional wave scatterings around the EP in the parametric space. In addition, the perfect imaging of a point source in the three-dimensional space, as a signature of negative refraction, is simulated to provide a verification of our work. We envision that this work may sharpen the understanding of P T-symmetric structures and inspire more acoustic functional devices.展开更多
基金supported by the National Key R&D Program of China(No.2021YFE0110900)the National Natural Science Foundation of China(Nos.U22B2078 and 11991033)。
文摘Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are frequency-dependent and unchangeable.Here,we present a reconfigurable 2D mechanism-based metamaterial which possesses transformable and frequency-independent elastic properties.Based on the proposed mechanism-based metamaterial,interesting functionalities,such as ternarycoded elastic wave polarizer and programmable refraction,are demonstrated.Particularly,unique ternary-coded polarizers,with 1-trit polarization filtering and 2-trit polarization separating of longitudinal and transverse waves,are first achieved.Then,the strong anisotropy of the proposed metamaterial is harnessed to realize positive-negative bi-refraction,only-positive refraction,and only-negative refraction.Finally,the wave functions with detailed microstructures are numerically verified.
基金the National Natural Science Foundation of China (Nos.52304123 and 52104077)the Postdoctoral Fellowship Program of CPSF (No.GZB20230914)+1 种基金the China Postdoctoral Science Foundation (No.2023M730412)the National Key Research and Development Program for Young Scientists (No.2021YFC2900400)。
文摘Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE source using refraction path is proposed.Firstly,the control equation of the refraction path is established according to the sensor coordinates and arrival times.Secondly,considering the influence of time-difference-of-arrival(TDOA)errors,the residual of the governing equation is calculated to estimate the equation weight.Thirdly,the refraction points in different directions are solved using Snell’s law and orthogonal constraints.Finally,the source coordinates are iteratively solved by weighted correction terms.The feasibility and accuracy of the proposed method are verified by pencil-lead breaking experiments.The simulation results show that the new method is almost unaffected by the refraction ratio,and always holds more stable and accurate positioning performance than the traditional method under different ratios and scales of TDOA outliers.
基金Supported by the Shenzhen Science and Technology Program (No.JCYJ20210324142800001).
文摘AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 emmetropia(E),429 low myopia(LM),80 moderate myopia(MM),and 32 low hypermetropia(LH)]aged 10 to 13y were analyzed.RPRs were measured using MRT without mydriasis.MRT results showed RPR at 0-15°(RPR 0-15),15°-30°(RPR 15-30),and 30°-45°(RPR 30-45)annular in the inferior(RPR-I),superior(RPR-S),nasal(RPR-N),and temporal(RPR-T)quadrants.Spherical equivalent(SE)was detected and calculated using an autorefractor.RESULTS:There were significant differences of RPR 15-30 between groups MM[0.02(-0.12;0.18)]and LH[-0.13(-0.36;0.12)](P<0.05),MM and E[-0.06(-0.20;0.10)](P<0.05),and LM[-0.02(-0.15;0.15)]and E(P<0.05).There were also significant differences of RPR 30-45 between groups MM[0.45(0.18;0.74)]and E[0.29(-0.09;0.67)](P<0.05),and LM[0.44(0.14;0.76)]and E(P<0.001).RPR values increased from the hyperopic to medium myopic group in each annular.There were significant differences of RPR-S between groups MM[-0.02(-0.60;0.30)]and E[-0.44(-0.89;-0.04)](P<0.001),and LM[-0.28(-0.71;0.12)]and E(P<0.05).There were also significant differences of RPR-T between groups MM[0.37(0.21;0.78)]and LH[0.14(-0.52;0.50)](P<0.05),LM[0.41(0.06;0.84)]and LH(P<0.05),and LM and E[0.29(-0.10;0.68),P<0.05].A Spearman’s correlation analysis showed a negative correlation between RPR and SE in the 15°-30°(P=0.005),30°-45°(P<0.05)annular(P=0.002),superior(P<0.001),and temporal(P=0.001)quadrants.CONCLUSION:Without pupil dilation,values for RPR 15-30,30-45,RPR-S,and T shows significant differences between myopic eyes and emmetropia,and the differences are negatively correlated with SE.
文摘AIM:To investigate the differences in retinal refraction difference values(RDVs)of adult patients with myopic anisometropia compared with those without myopic anisometropia,and to investigate the relationship between ocular biometric measurements and relative peripheral refraction.METHODS:This clinical observation study included 130 patients with myopia(-0.25 to-10.00 D)between October 2022 and January 2023 aged between 18 and 40y.The patients were divided into anisometropia(n=63;difference in binocular anisometropia≥1.00 D)and non-anisometropia(n=67;difference in binocular anisometropia<1.00 D)groups accordingly.Ocular biometric measurements were performed by optical biometrics and corneal topography to assess the steep keratometry(Ks),flap keratometry(Kf),axial length(AL),corneal astigmatism(CYL;Ks-Kf),surface regularity index(SRI),surface asymmetry index(SAI),and central corneal thickness(CCT).The RDV was measured at five retinal areas from the fovea to 53 degrees(RDV-0-10,RDV-10-20,RDV-20-30,RDV-30-40,and RDV-40-53),the total RDV(TRDV)of 53 degrees,and four regions,including RDV-superior,RDV-inferior,RDV-temporal,and RDV-nasal.An analysis of Spearman correlation was carried out to examine the correlation between RDV and the spherical equivalent(SE)and ocular biological parameters.RESULTS:Within RDV-20-53,both groups showed relative hyperopic defocus,and the increase in RDV corresponds to the increase in eccentricity.In the myopic anisometropia group,the TRDV,RDV-20-53,RDV-superior,and more myopic eyes had significantly higher RDVtemporal values than less myopic eyes.(P<0.05).In the non-anisometropia group,there was no significant difference in the RDV between the more and less myopic eyes at different eccentricities(P>0.05).There was a negative correlation between SE and TRDV(r=-0.205,P=0.001),RDV-20-53(r=-0.281,-0.183,-0.176,P<0.05),RDV-superior(r=-0.251,P<0.001),and RDV-temporal(r=-0.230,P<0.001),a negative correlation between CYL and RDV-10-30(r=-0.147,-0.180,P<0.05),and a negative correlation between SRI and RDV-0-20(r=-0.190,-0.170,P<0.05).AL had a positive correlation with RDV-20-30(r=0.164,P=0.008)and RDV-temporal(r=0.160,P=0.010).CONCLUSION:More myopic eyes in patients with myopic anisometropia show more peripheral hyperopic defocus.Diopter and corneal morphology may affect peripheral retinal defocus.
基金Project supported by the National Natural Science Foundation of China(Grant No.61671279)financial support from Xi’an Key Laboratory of Optical Information Manipulation and Augmentation(OMA)。
文摘We investigate the electromagnetic properties of a four-level dense atomic gas medium with Doppler effect.It is shown that the relative permittivity and relative permeability of the medium can be negative simultaneously with low absorption in the same detuning interval on account of electromagnetically induced transparency.Furthermore,with the suitable parameters,the nonreciprocal negative refraction can be obtained due to the Doppler effect,and the nonreciprocity frequency band can be regulated by adjusting the temperature,the intensity of the control field and the atomic density in this hot atomic medium.
基金Supported by National Institute for Medical Research Development(NIMAD)affiliated with the Iranian Ministry of Health and Medical Education(No.963660).
文摘AIM:To compare the subjective refraction data with non-cycloplegic auto-refraction findings in the geriatric population above 60 years of age according to the different crystalline lens conditions.METHODS:This report is a part of the Tehran Geriatric Eye Study(TGES)that was conducted from January 2019 to January 2020 on elderly population 60 years of age and above in Tehran.The samples were selected by multistage stratified random cluster sampling.Of 3791 individual invitees,3310(response rate:87.3%)participated in this study.All study participants underwent non-cycloplegic autorefraction(auto-refractometer/keratometer Nidek ARK-510)and subjective refraction.RESULTS:Regarding the sphere,eyes with mixed cataract had the worst limits of agreement(LoA:-1.24 to 0.87)and the best agreement was related to the pseudophakic eyes(LoA:-0.83 to 0.54).The highest(0.27±0.31 D)and lowest(0.21±0.27 D)differences between the two methods regarding the cylinder power were observed in eyes with cortical cataract and normal eyes,respectively.The worst LoA between the two methods in measuring the cylinder power was related to the eyes with mixed cataract(LoA:-0.44 to 0.96).Regarding the J0(horizontal/vertical components of astigmatism),the mean values of J0 obtained by auto-refraction were tended more toward against the rule direction in all crystalline lens conditions,and the two methods had the greatest difference in cortical cataract cases(0.05±0.17 D).Regarding the J45(oblique components of astigmatism),the lowest(0±0.11 D)and highest(-0.01±0.12 D)differences were observed in normal eyes and eyes with cortical cataract,respectively.CONCLUSION:The auto-refractometer/keratometer Nidek ARK-510 results in the elderly with different phakic and pseudophakic conditions do not correspond well with subjective refraction findings.This discrepancy in spherical findings is more pronounced in individuals with mixed cataract than in other cases.
基金supported by the National Key R&D Program of China (Grant Nos. 2022YFA1404400 and 2022YFA1404403)the National Natural Science Foundation of China (Grant No. 92263208)+3 种基金the Natural Science Foundation of Jiangsu Province (Grant No. BK20210541)the Natural Science Foundation of the Jiangsu Higher Education Institutions of China (Grant No. 21KJB140003)the Fundamental Research Funds for the Central Universitiesthe Open Fund of State Key Laboratory of Acoustics (Grant No. SKLA202313)。
文摘We demonstrate a method to realize unidirectional negative refraction in an acoustic parity-time(P T)-symmetric system, which is composed of a pair of metasurfaces sandwiching an air gap. The pair of metasurfaces possesses loss and gain modulations. The unidirectional negative refraction, which is strictly limited to the case of incident wave imposing on the loss end of the metasurface, is demonstrated at the exception point(EP) in this P T-symmetric system, while the incidence from the other side leads to strong reflection. Based on rigorous calculations, we explicitly show the underlying mechanism of this model to achieve unidirectional wave scatterings around the EP in the parametric space. In addition, the perfect imaging of a point source in the three-dimensional space, as a signature of negative refraction, is simulated to provide a verification of our work. We envision that this work may sharpen the understanding of P T-symmetric structures and inspire more acoustic functional devices.