期刊文献+
共找到11,048篇文章
< 1 2 250 >
每页显示 20 50 100
Prevalence of visual impairment and estimation of refractive errors among school children in Kakamega,Kenya 被引量:1
1
作者 Isabel Signes-Soler Alfred Ragot +2 位作者 Sheilah Nangena Andrew Wekesa Raúl Montalbán Llamusí 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期932-939,共8页
AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was... AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was cross-sectional.Totally 3343 participants were included in the study.The initial examination involved assessing the uncorrected distance visual acuity(UDVA)and visual acuity(VA)while using a+2.00 D lens.The inclusion criteria for a subsequent comprehensive cycloplegic eye examination,performed by an optometrist,were as follows:a UDVA<0.6 decimal(0.20 logMAR)and/or a VA with+2.00 D≥0.8 decimal(0.96 logMAR).RESULTS:The sample had a mean age of 10.92±2.13y(range 4 to 17y),and 51.3%of the children were female(n=1715).The majority of the children(89.7%)fell within the age range of 8 to 14y.Among the ethnic groups,the highest representation was from the Luhya group(60.6%)followed by Luo(20.4%).Mean logMAR UDVA choosing the best eye for each student was 0.29±0.17(range 1.70 to 0.22).Out of the total,246 participants(7.4%)had a full eye examination.The estimated prevalence of myopia(defined as spherical equivalent≤-0.5 D)was found to be 1.45%of the total sample.While around 0.18%of the total sample had hyperopia value exceeding+1.75 D.Refractive astigmatism(cil<-0.75 D)was found in 0.21%(7/3343)of the children.The VI prevalence was 1.26%of the total sample.Among our cases of VI,76.2%could be attributed to uncorrected refractive error.Amblyopia was detected in 0.66%(22/3343)of the screened children.There was no statistically significant correlation observed between age or gender and refractive values.CONCLUSION:The primary cause of VI is determined to be uncorrected refractive errors,with myopia being the most prevalent refractive error observed.These findings underscore the significance of early identification and correction of refractive errors in school-aged children as a means to alleviate the impact of VI. 展开更多
关键词 visual impairment refractive errors MYOPIA AMBLYOPIA sustainable development goals
下载PDF
Relative peripheral refraction in school children with different refractive errors using a novel multispectral refraction topographer
2
作者 Hui-Ling Hu Serena Zhe-Chuang Li +3 位作者 Ai-Ying Feng Hao-Xi Zhong Jing-Feng Mu Mei-Zhou Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1477-1482,共6页
AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 e... AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 emmetropia(E),429 low myopia(LM),80 moderate myopia(MM),and 32 low hypermetropia(LH)]aged 10 to 13y were analyzed.RPRs were measured using MRT without mydriasis.MRT results showed RPR at 0-15°(RPR 0-15),15°-30°(RPR 15-30),and 30°-45°(RPR 30-45)annular in the inferior(RPR-I),superior(RPR-S),nasal(RPR-N),and temporal(RPR-T)quadrants.Spherical equivalent(SE)was detected and calculated using an autorefractor.RESULTS:There were significant differences of RPR 15-30 between groups MM[0.02(-0.12;0.18)]and LH[-0.13(-0.36;0.12)](P<0.05),MM and E[-0.06(-0.20;0.10)](P<0.05),and LM[-0.02(-0.15;0.15)]and E(P<0.05).There were also significant differences of RPR 30-45 between groups MM[0.45(0.18;0.74)]and E[0.29(-0.09;0.67)](P<0.05),and LM[0.44(0.14;0.76)]and E(P<0.001).RPR values increased from the hyperopic to medium myopic group in each annular.There were significant differences of RPR-S between groups MM[-0.02(-0.60;0.30)]and E[-0.44(-0.89;-0.04)](P<0.001),and LM[-0.28(-0.71;0.12)]and E(P<0.05).There were also significant differences of RPR-T between groups MM[0.37(0.21;0.78)]and LH[0.14(-0.52;0.50)](P<0.05),LM[0.41(0.06;0.84)]and LH(P<0.05),and LM and E[0.29(-0.10;0.68),P<0.05].A Spearman’s correlation analysis showed a negative correlation between RPR and SE in the 15°-30°(P=0.005),30°-45°(P<0.05)annular(P=0.002),superior(P<0.001),and temporal(P=0.001)quadrants.CONCLUSION:Without pupil dilation,values for RPR 15-30,30-45,RPR-S,and T shows significant differences between myopic eyes and emmetropia,and the differences are negatively correlated with SE. 展开更多
关键词 relative peripheral refraction MYOPIA school children multispectral refraction topography
下载PDF
Refraction difference value variations in children and adolescents with different refractive errors
3
作者 Da-Wen Wu Ze-Yi Yang +4 位作者 Yan Nie He-Ya Ye Liang Chen Long-Qian Liu Guo-Yuan Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2236-2242,共7页
AIM:To evaluate the refraction difference value(RDV)variations in children and adolescents with different refractive errors and analyze its correlation with refractive development.METHODS:Participants aged 4-16y with ... AIM:To evaluate the refraction difference value(RDV)variations in children and adolescents with different refractive errors and analyze its correlation with refractive development.METHODS:Participants aged 4-16y with different refractive statuses(hyperopia,emmetropia,myopia)underwent comprehensive eye examinations,including spherical equivalent(SE)refraction,axial length(AL),total RDV(TRDV),and RDVs at various eccentricities(0°-15°,15°-30°,30°-45°)and quadrants(inferior,superior,nasal,temporal).Statistical analysis involved one-way ANOVA for group comparisons and Pearson correlation for examining relationships between SE/AL and RDVs.Paired t-tests compared quadrant-specific RDVs within groups.RESULTS:Significant difference was found in TRDV(P<0.001),RDV15°-30°(P=0.033),RDV30°-45°(P<0.001),RDV-inferior(RDV-I,P<0.001)and RDV-temporal(RDV-T,P<0.001)among hyperopia,emmetropia and myopia group.Pearson correlation analysis revealed a negative correlation of SE with TRDV(P=0.001),RDV30°-45°(P=0.004),RDV-I(P=0.047),and RDV-T(P<0.001).The differences between RDV-superior(RDV-S)and RDV-I were statistically significant in all groups(P<0.001 for all)and between RDV-T and RDV-nasal(RDV-N)were statistically significant in hyperopia group(P<0.001).Within the premyopic group,the analysis revealed a negative correlation of SE with RDV-I(P=0.009).Pearson correlation analysis revealed a positive correlation of AL with TRDV(P=0.036),RDV15°-30°(P=0.004),RDV30°-45°(P<0.001),RDV-S(P=0.003),RDV-I(P<0.001),RDV-T(P<0.001),RDV-N(P=0.022),while revealed a negative correlation of AL with RDV0-15°(P=0.018).CONCLUSION:Our study indicates TRDV,RDV30°-45°,RDV-I,RDV-T may relate to refractive development,and a negative correlation between SE and RDV-I in pre-myopic children. 展开更多
关键词 multispectral refractive topography refraction difference value degrees of myopia children adolescents
下载PDF
Prevalence of refractive errors in school-aged and preadolescent children in Colombia
4
作者 Diana Garcia-Lozada Diana Valeria Rey-Rodríguez +1 位作者 Sara Viviana Angulo-Sánchez Jenny Maritza Sánchez-Espinosa 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2288-2294,共7页
AIM:To describe the distribution of refractive errors by age and sex among schoolchildren in Soacha,Colombia.METHODS:This was an observational cross-sectional study conducted in five urban public schools in the munici... AIM:To describe the distribution of refractive errors by age and sex among schoolchildren in Soacha,Colombia.METHODS:This was an observational cross-sectional study conducted in five urban public schools in the municipality of Soacha.A total of 1161 school-aged and pre-adolescent children,aged 5-12y were examined during the school year 2021-2022.Examinations included visual acuity and static refraction.Spherical equivalent(SE)was analysed as follows:myopia SE≤-0.50 D and uncorrected visual acuity of 20/25 or worse;high myopia SE≤-6.00 D;hyperopia SE≥+1.00 D(≥7y)or SE≥+2.00 D(5-6y);significant hyperopia SE≥+3.00 D.Astigmatism was defined as a cylinder in at least one eye≥1.00 D(≥7y)or≥1.75 D(5-6y).If at least one eye was ametropic,children were classified according to the refractive error found.RESULTS:Of the 1139 schoolchildren included,50.6%were male,58.8%were aged between 5 and 9y,and 12.1%were already using optical correction.The most common refractive error was astigmatism(31.1%),followed by myopia(20.8%)and hyperopia(13.1%).There was no significant relationship between refractive error and sex.There was a significant increase in astigmatism(P<0.001)and myopia(P<0.0001)with age.CONCLUSION:Astigmatism is the most common refractive error in children in an urban area of Colombia.Emmetropia decreased and myopia increased with age. 展开更多
关键词 Colombia PREVALENCE refractive errors MYOPIA HYPEROPIA ASTIGMATISM CHILDREN
下载PDF
Prevalence of Refractive Errors among School Children Aged 5 to 15 Years Old at CHU-IOTA
5
作者 Kadiatou Ba Aichata Tall +19 位作者 Mory Coulibaly Cheick Sogodogo Zoumana Bagayogo Aoua Ibrahim Toure Ousmane Toure Brainima Coulibaly Fatoumata Tata Sidibe Aly Konipo Roucky Sangare Seydou Diallo Moro Sidibe Oumar Diallo Assiatou Simaga Gounon Saye Modibo Sissoko Mamadou Kole Sidibe Sidi Diarra Nouhoum Guirou Abdoulaye Napo Adama Guindo 《Surgical Science》 2024年第8期480-491,共12页
Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school ch... Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school children aged 5 to 15 at CHU-IOTA. Patients and Method: This is a prospective, descriptive cross-sectional study carried out in the ophthalmic-pediatrics department of CHU-IOTA, from October to November 2023. Results: We received 340 school children aged 5 to 15, among whom 111 presented ametropia, i.e. a prevalence of 32.65%. The average age was 11.42 ± 2.75 years and a sex ratio of 0.59. The average visual acuity was 4/10 (range 1/10 and 10/10). We found refractive defects: astigmatism 73.87%, hyperopia 23.87% of cases and myopia 2.25%. The decline in distance visual acuity was the most common functional sign. Ocular abnormalities associated with ametropia were dominated by allergic conjunctivitis (26.13%) and papillary excavation (6.31%) in astigmatics;allergic conjunctivitis (9.01%) and papillary excavation (7.20%) in hyperopic patients;turbid vitreous (0.90%), myopic choroidosis (0.45%) and allergic conjunctivitis (0.45%) in myopes. Conclusion: Refractive errors constitute a reality and a major public health problem among school children. 展开更多
关键词 refractive Errors PREVALENCE CHILD CHU-IOTA
下载PDF
A Transparent Photoresist Made of Titanium Dioxide Nanoparticle-Embedded Acrylic Resin with a Tunable Refractive Index for UV-Imprint Lithography
6
作者 Yinglu Liu Dan Wang +7 位作者 Changlin Liu Qianqian Hao Jian Li Jie-Xin Wang Xiuyun Chen Peng Zhong Xibin Shao Jian-Feng Chen 《Engineering》 SCIE EI CAS CSCD 2024年第6期96-104,共9页
Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of ... Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of titanium dioxide nanoparticles embedded in acrylic resin with a high RI for ultraviolet(UV)-imprint lithography.The hybrid film exhibits a tunable RI of up to 1.67(589 nm)after being cured by UV light,while maintaining both a high transparency of over 98%in the visible light range and a low haze of less than 0.05%.The precision machining of optical microstructures can be imprinted easily and efficiently using the hybrid resin,which acts as a light guide plate(LGP)to guide the light from the side to the top in order to conserve the energy of the display device.These preliminary studies based on both laboratory and commercial experiments pave the way for exploiting the unparalleled optical properties of nanocomposite resins and promoting their industrial application. 展开更多
关键词 PHOTORESIST Tunable refractive index Hanson solubility Ultraviolet imprint Organic-inorganic composites
下载PDF
Prevalence and Factors Associated with Refractive Errors among University Students at Mbarara University of Science and Technology, Uganda
7
作者 Denis Kamara John Onyango +5 位作者 Simon Arunga Mwanja Pius Pliers Denis Tusingwire Mary Assumpta Ayoo Eric Ronald Mulongo Barnabas Atwiine 《Open Journal of Ophthalmology》 2024年第3期324-338,共15页
Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors d... Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors due to their curriculum that requires a lot of near work affecting their performance and quality of life unknowingly. Genetic and environmental factors are thought to play a role in the development of refractive errors. This study addresses the paucity of knowledge about refractive errors among university students in East Africa, providing a foundation for further research. Objectives: To determine the prevalence and factors associated with refractive errors among students in the Faculty of Medicine at Mbarara University of Science and Technology. Methodology: This was a cross-sectional descriptive and analytical study in which 368 undergraduate students selected using random sampling were assessed for refractive errors from March 2021-July 2021. Eligible participants were recruited and their VA assessment done after answering a questionnaire. Students whose VA improved on pin hole had subjective retinoscopy and results were compiled and imported to STATA 14 for analysis. Results: The prevalence of refractive errors was 26.36% with (95% CI) among university students especially myopia. Myopia is most predominant at 60%, followed by 37% Astigmatism and hyperopia of 3% among medical students. Astigmatism consisted of largely myopic astigmatism 72% (26) and 28% (10) compound/mixed astigmatism only. Student positive family history of refractive error was found to have a statistically significant relationship with refractive errors with AOR 1.68 (1.04 - 2.72) (95% CI) and P (0.032). Conclusion: The prevalence of refractive errors among university students, especially myopia, was found to be high and family history was associated with students having refractive errors. 展开更多
关键词 refractive Errors PREVALENCE Myopia ASTIGMATISM HYPEROPIA HYPERMETROPIA UNIVERSITY Students BLINDNESS Visual Impairment
下载PDF
Surface phonon resonance:A new mechanism for enhancing photonic spin Hall effect and refractive index sensor
8
作者 程杰 汪承龙 +3 位作者 李一铭 张亚林 刘胜利 董鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期254-261,共8页
Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit ... Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit their applications beyond the near-infrared regime.In this work,we theoretically present a new mechanism to enhance the photonic SHE by taking advantage of SiC-supported surface phonon resonance(SPhR)in the mid-infrared regime.The transverse displacement of photonic SHE is very sensitive to the wavelength of incident light and the thickness of SiC layer.Under the optimal parameter setup,the calculated largest transverse displacement of SiC-based SPhR structure reaches up to 163.8 ym,which is much larger than the condition of SPR.Moreover,an NO_(2) gas sensor based on the SPhR-enhanced photonic SHE is theoretically proposed with the superior sensing performance.Both the intensity and angle sensitivity of this sensor can be effectively manipulated by varying the damping rate of SiC.The results may provide a promising paradigm to enhance the photonic SHE in the mid-infrared region and open up new opportunity of highly sensitive refractive index sensors. 展开更多
关键词 photonic spin Hall effect refractive index sensor surface phonon resonance SIC
下载PDF
Fabrication of UV-Curing Linalool-Polysiloxane Hybrid Films with High Refractive Index and Transparency
9
作者 Wenqing Xiao Lewen Tan +2 位作者 Xunjun Chen Qiaoguang Li Yunqing Ruan 《Journal of Renewable Materials》 EI CAS 2024年第3期569-583,共15页
In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance ... In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance spectra(NMR)results showed that TPS conformed to the predicted structures.Natural terpene linalool was exploited as photocrosslinker to fabricate UV-curing linalool-polysiloxane hybrid films(LPH)with TPS via photoinitiated thiol-ene reaction.LPH rapidly cured under UV irradiation at the intensity of 80 mW/cm^(2) in 30 s,exhibiting good UV-curing properties.The optical transmittance of LPH in the wavelength of 300-800 nm was over 90%,exhibiting good optical transparency.The water contact angle and water vapor permeability results showed that the introduction of phenyl groups enhance the hydrophobicity and water vapor barrier properties of LPH.The results indicated the potential of LPHs in the applications of optical functional coatings. 展开更多
关键词 UV-CURING polysiloxane hybrid films high refractive index TRANSPARENCY
下载PDF
Relative peripheral refractive errors in Chinese children with myopic anisometropia
10
作者 Yu-Ting Tong Yu-Qin Du +4 位作者 Shan-Shan Ge Li Chen Xiao-Qi Ma Yu-Juan Guo Yue-Hua Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第11期2074-2081,共8页
AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-section... AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-sectional study included 160 children divided into two groups according to the interocular spherical equivalent refraction(SER)difference≥1.0 D in the MAI group(n=80)and<1.0 D in the non-MAI group(n=80).The MAI group was further divided into two subgroups:ΔSER<2.0 D group and ΔSER≥2.0 D group.Basic ocular biometric parameters of axial length(AL),average keratometry(Ave K),cylinder(CYL),surface regularity index(SRI),and surface asymmetry index(SAI)were recorded.In addition,multispectral refraction topography was performed to measure RPRE,and the parameters were recorded as total refraction difference value(TRDV),refraction difference value(RDV)0-10,RDV10-20,RDV20-30,RDV30-40,RDV40-53,RDV-superior(RDV-S),RDV-inferior(RDV-I),RDV-temporal(RDV-T)and RDV-nasal(RDV-N).RESULTS:In the non-MAI group,the interocular differences of all parameters of RPRE were not significant.In the MAI group,the interocular differences of TRDV,RDV10-53,RDV-S,RDV-I,RDV-T,and RDV-N were significant.In subgroup analysis,the interocular differences of TRDV,RDV30-53,RDV-I,and RDV-T were significant in ΔSER<2.0 D group and ΔSER≥2.0 D group,but the interocular differences of RDV10-30,RDV-S and RDV-N were only significant in the ΔSER≥2.0 D group.In correlation analysis,ΔTRDV,ΔRDV 10-53,ΔRDV-S,and ΔRDV-N were negatively correlated with ΔSER but positively correlated with ΔAL.CONCLUSION:The more myopic eyes have larger hyperopic RPRE in Chinese children with MAI in certain retinal range,and partialΔRPRE is closely associated with ΔSER and ΔAL. 展开更多
关键词 MYOPIA ANISOMETROPIA relative peripheral refractive error ocular biometric parameters
下载PDF
Determination of the time of refractive stability after uneventful phacoemulsification in Indian eyes
11
作者 Ashok Kumar Nanda Bijnya Birajita Panda +1 位作者 Asish Swain Logesh Balakrishnan 《World Journal of Experimental Medicine》 2024年第2期89-96,共8页
BACKGROUND Knowledge about refractive stabilization and the accuracy of postoperative refractive error measurements are crucial for improved patient outcomes after phacoemulsification.Existing guidelines typically rec... BACKGROUND Knowledge about refractive stabilization and the accuracy of postoperative refractive error measurements are crucial for improved patient outcomes after phacoemulsification.Existing guidelines typically recommend waiting 4-6 wk before prescribing corrective lenses.Our research focused on identifying factors that influence refractive errors in the early stages of post-cataract surgery,thus contributing to the existing literature on this topic.AIM To investigate the time required for refraction stability after uneventful phacoemulsification surgery.METHODS We compared the variation and statistical significance of the difference in spherical,cylindrical components,and the spherical equivalent between the 1-and 6-wk follow-up period in a group of 257 eyes that underwent uneventful phacoemulsification with foldable intraocular lens implantation,all performed by a single experienced surgeon.The Wilcoxon-Signed Rank Test was utilized to assess the magnitude of the change and determine its statistical significance.The refractive stability was defined as the point at which the change in spherical equivalent was within±0.5 dioptres for two consecutive visits.RESULTS The average age of the patients was 64.9±8.9 yr.The differences observed in both the visits in spherical power(0.1±0.2),cylinder power(0.3±0.4),and spherical equivalent(0.2±0.2)were minimal and not statistically significant.The majority of eyes(93.4%)achieved refractive stability within 6 wk after the surgery.The cylindrical power differed between age groups at the 6th wk post-operative and the difference was statistically significant(P value 0.013).There were no significant differences in refractive stability when considering sex and axial length.CONCLUSION Phacoemulsification with foldable intraocular lens implantation results in no significant changes in refraction for the majority of cases during the 6-wk follow-up period.Therefore,a spectacle prescription can be given at the completion of 1 wk. 展开更多
关键词 Cataract surgery PHACOEMULSIFICATION refraction stability Visual acuity Spherical equivalent
下载PDF
Measurement of Refractive Indices of (Al_xGa_(1-x))_(0.51)In_(0.49)P Grown by Low Pressure Organometallic Vapor Phase Epitaxy
12
作者 廉鹏 马骁宇 +1 位作者 张广泽 陈良惠 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2001年第4期398-401,共4页
The refractive indices of disordered (Al xGa 1-x ) 0 51 In 0 49 P,which is grown by low-pressure organometallic vapor phase epitaxy and lattice-matched to GaAs substrate,have been determined by measurin... The refractive indices of disordered (Al xGa 1-x ) 0 51 In 0 49 P,which is grown by low-pressure organometallic vapor phase epitaxy and lattice-matched to GaAs substrate,have been determined by measuring their reflectance spectra when the wavelength ranges between 0 5 to 2 5 micrometer.A single-oscillator dispersion model is used to verify the experiment data and calculate the reflectance spectrum.The refractive indices are used to analyze the waveguide of strain quantum well GaInP/AlGaInP visible laser diode.The simulated far field pattern is consistent with the experimental results very well. 展开更多
关键词 LP-OMVPE refractive index MEASUREMENT GAINP/ALGAINP
下载PDF
Refractive errors in high myopic eyes after phacovitrectomy for macular hole 被引量:10
13
作者 Donghyun Jee Yi-Ryeung Park +2 位作者 Kyoung In Jung Eunchul Kim Tae Yoon La 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期369-373,共5页
AIM: To examine the refractive prediction error in high myopic eyes after phacovitrectomy.METHODS: This retrospective comparative case series included 91 eyes(18 high myopic eyes and 73 non-high myopic eyes) of 91 pat... AIM: To examine the refractive prediction error in high myopic eyes after phacovitrectomy.METHODS: This retrospective comparative case series included 91 eyes(18 high myopic eyes and 73 non-high myopic eyes) of 91 patients who underwent successful phacovitrectomy(phacoemulsification, intraocular lens implantation, and pars plana vitrectomy). The high myopic eyes were defined as the eye with more than 26.0mm of axial length. The postoperative prediction error of mean error and mean absolute error were evaluated at4 mo postoperatively. Axial length and keratometry measurement were performed preoperatively and 4mo postoperatively using the IOL Master.RESULTS: The refractive outcome after phacovitrectomy showed significantly greater myopic shift in the high myopic eyes [-1.08 ±0.87 diopters(D)] than that in the non-high myopic eyes(-0.43 ±0.63 D, P =0.004). Axial length and keratometric value in the high myopic eyes were significantly increased(P =0.043, 0.037 respectively),whereas those in the non-high myopic group were not significantly increased(P =0.135, 0.347 respectively). The change of the axial length in the myopic eye(0.46±0.28 mm)was greater than that in the non- high myopic eye(0.11 ± 0.34 mm; P 【0.001).CONCLUSION: High myopic eyes showed more myopic shift than non-high myopic eyes after phacovitrectomy.The cause of myopic shift in high myopic eyes seems tobe attributed to actual elongation of the axial length in high myopia. 展开更多
关键词 axial length high myopic eyes KERATOMETRY phacovitrectomy refractive errors
下载PDF
The evolution of refractive status in Chinese infants during the first year of life and its affected factors 被引量:7
14
作者 Shu-Juan Yu Guo-Hua Liu +4 位作者 Yi Liu Jing Huang Ming-Lei Han Bo-dun Zha Zhong-Tao Gai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第8期1290-1294,共5页
AIM: To study the evolution of the refractive status and examine the affected factors in infants during the first year of life in a large sample size in China. METHODS: A total of 1258 babies (2516 eyes) aged 32w... AIM: To study the evolution of the refractive status and examine the affected factors in infants during the first year of life in a large sample size in China. METHODS: A total of 1258 babies (2516 eyes) aged 32wk gestational age to ty participated in the study, including 766 premature and 492 full-term infants. First, each baby received an orthoptic examination, slit-lamp checking and fundus imaging. Patients with diseases which might affect refractive status were excluded from the cohort. The cycloplegia retinoscopy was performed. Their neonatal histories were reviewed. Each measurement contained the refractive status and calculation of the spherical equivalent (SE). RESULTS: Refractive state showed an average hyperopia of +0.94_+1.63 D at early ages, followed by a trend toward more hyperopia. The refractive state reached the top (+2.431.46 D) at the age of one to two months. Then gliding till one year old when the refractive state reached +0.59:1.41 D. The prevalence of astigmatism was 42.17% in the study, being 2.82% myopic astigmatism and 39.35% hyperopic astigmatism. The 94.1% of hyperopic astigmatism was with-the-rule astigmatism and 71.83% of myopic astigmatism was with-the-rule astigmatism. Refractive state between boys and girls was different. The mean SE of boys was +1.97+1.57 D, while that of girls was +1.79+1.46 D, and the difference was significant. CONCLUSION: Before one year old, the change of refractive status is associated with checking age and sex. At the age of one to two months, the degree of hyperopia reaches the top. Boys have more hyperopic degree than girls, and with- the-rule astigmatism is predominant. Excluding premature infants with advanced retinopathy of prematurity, premature and full-term children have same refraction status. 展开更多
关键词 refractive status corrected age infant prematurity spherical equivalent cycloplegic retinoscopy
下载PDF
Axial length/corneal radius of curvature ratio and refractive development evaluation in 3-to 4-year-old children: the Shanghai Pudong Eye Study 被引量:7
15
作者 Ke-Ke Zhao Yuan Yang +4 位作者 Hong Wang Lu Li Zhao-Yang Wang Fan Jiang Ji-Fang Qu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第6期1021-1026,共6页
AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairme... AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairment screening of 3 to 4 y kindergarten students.METHODS: Between April and June 2017, a total of 4350 participants aged 3-to 4-year-old(8700 eyes) from 10 cluster random sampling kindergartens in Shanghai, Pudong District were involved. According to the measurement and analysis of the unaided visual acuity(VA), AL, CRC, AL/CRC ratio, astigmatism and other refractive parameters, the data distribution and reference range were obtained.RESULTS: Uncorrected VA of examined children was 0.23±0.08(logMAR, mean±SD) [95% confidence interval(CI) range ≤0.36];AL was 22.10±0.79 mm(95%CI 20.55-23.65);CRC was 7.86±0.26 mm(95%CI, 7.35-8.37);AL/CRC ratio was 2.81±0.12(95%CI, 2.57-3.05). The median of astigmatism was-0.5 D, a total of 56.3% had astigmatism <-0.50 D, 85.3%<-1.00 D, 6.7%>-1.50 D;71% were astigmatism with the rule. Eye-specific analyses were conducted. Statistical difference of VA was in right and left eyes. There were no significant differences between two eyes of AL, CRC, AL/CRC ratio and astigmatism(P>0.05).CONCLUSION: VA and AL/CRC ratio reference could be used to assess refractive development in children and screening uncorrected refractive errors or amblyopia. Astigmatism needs to be considered in the diagnosis. 展开更多
关键词 CHILDREN axial length/corneal RADIUS of curvature RATIO refractive development visual IMPAIRMENT reference
下载PDF
Correlation analysis and multiple regression formulas of refractive errors and ocular components 被引量:4
16
作者 Chao-Kai Chang Jui-Teng Lin Yong Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第5期858-861,共4页
The multiple regression formulas and correlation of ocular components with refractive errors are presented by Gaussian optics. The refractive error changing rate for the cornea and lens power, the axial length, anteri... The multiple regression formulas and correlation of ocular components with refractive errors are presented by Gaussian optics. The refractive error changing rate for the cornea and lens power, the axial length, anterior chamber depth(ACD) and vitreous chamber depth(VCD) are calculated, including nonlinear terms for more accurate rate functions than the linear theory. Our theory, consistent with the empirical data, shows that the Pearson correlation coefficients for spherical equivalent(SE) and ocular components are highest for SE with axial length, ACD and VCD and weakest for corneal power, lens power and lens thickness. Moreover, our regression formulas show the asymmetric feature of the correlation that the axial length, ACD and VCD are more strongly correlated(with higher negative regression constants) with refractive errors in eyes with hyperopia than in eyes with myopia, particularly for severe hyperopia. 展开更多
关键词 HUMAN eye OCULAR COMPONENTS refractive ERRORS regression FORMULAS CORRELATION
下载PDF
The prevalence of vision impairment and refractive error in 3654 first year students at Tianjin Medical University 被引量:6
17
作者 Xue-Ying Shi Yi-Feng Ke +3 位作者 Nan Jin Hong-Mei Zhang Rui-Hua Wei Xiao-Rong Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第10期1698-1703,共6页
AIM:To determine the prevalence of vision impairment(VI)and refractive error in first year university students at the Tianjin Medical University.METHODS:This is a cross-sectional observational cohort study of VI a... AIM:To determine the prevalence of vision impairment(VI)and refractive error in first year university students at the Tianjin Medical University.METHODS:This is a cross-sectional observational cohort study of VI and refractive error among first year university students at the Tianjin Medical University.The first year university students were involved in this study and were given a detailed questionnaire including age,birth date,and spectacle wearing history.A standardized ophthalmologic examination including visual acuity(VA),slit-lamp examination,non-cycloplegic auto-refraction,objective refraction,fundus photography,and examination of their spectacles were recorded.RESULTS:A total of 3654 participants were included in this study.Totally 3436(94.03%) individuals had VI in this population.Totally 150(4.10%) individuals had VI due to ocular disease,including amblyopia,congenital cataract,retinal atrophy or degeneration,strabismus,congenital nystagmus,refractive surgery orthokeratology.Totally 3286(89.93%) subjects had VI due to refractive error.Only 218(5.97%) students were emmetropia.Moreover,refractive error was the main cause for the VI(95.63%).Totally 3242(92.52%) students were myopia and the prevalence of mild,moderate,and high myopia subgroup was 27.05%,44.35%,and 21.26% respectively.Totally 44(1.29%) subjects were hyperopic.The rates of uncorrected visual acuity(UCVA),presenting visual acuity(PVA)and best corrected visual acuity(BCVA)which better than 20/20 in both eyes were 5.65%,22.32% and 82.13% respectively.The rates of correction,under correction and well correction in myopia subjects were 82.73%,84.39% and 15.61%,respectively. CONCLUSION:We present a high prevalence of refractive errors and high rates of under correction refractive error among first year university students.These results may help to promote vision protection work in young adults. 展开更多
关键词 vision impairment refractive error corrective status MYOPIA first year university students
下载PDF
Analysis of changes in crystalline lens thickness and its refractive power after laser in situ keratomileusis 被引量:5
18
作者 Liang Wang, Hai-Ying Jin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期97-101,共5页
AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperat... AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperative central ACD which were measured with Pentacam, Orbscan, IOL-Master and A-scan ultrasonography, central corneal true net power which was measured with the Pentacam, Orbscan and IOL-Master, axial length (AL) which was measured with IOL-Master and LT which was measured with the A-scan ultrasonography were compared using the paired sample t test. Ocular refractive errors and lens refractive power at corneal plane were calculated and their correlations were also evaluated before and after LASIK. RESULTS: At 1 week after LASIK, LT and crystalline lens refractive power at corneal plane (Dlens) which were associated with the IOL-Master and Pentacam increased significantly (P <= 0.005), ACD decreased significantly (P <= 0.001), but no significant increase was observed in the Diens which was associated with the Orbscan(P=0.261). Significant correlations between the changes in the ocular refractive errors and Diens which were associated with the Pentacam were observed at 1 week and 6 months after LASIK (P = 0.028; P=0.001). CONCLUSION: LT increased significantly after LASIK, and this might partially lead to ACD decrease, Diens increase and a small quantity of myopic regression. 展开更多
关键词 anterior chamber depth crystalline lens thickness refractive power
下载PDF
Effects of the long wavelength-filtered continuousspectrum on natural refractive development in juvenile guinea pigs 被引量:3
19
作者 Rui-Qin Li Wei-Zhong Lan +5 位作者 Xiao-Ning Li Hao-Ran Wu Qing-Lin Xu Hong Zhong Wen-Tao Li Zhi-Kuan Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第6期883-891,共9页
AIM: To investigate the effects of spectral composition and light intensity on natural refractive development in guinea pigs.METHODS: A total of 124 pigmented guinea pigs(2-week-old) were randomly assigned to three gr... AIM: To investigate the effects of spectral composition and light intensity on natural refractive development in guinea pigs.METHODS: A total of 124 pigmented guinea pigs(2-week-old) were randomly assigned to three groups at high(Hi;4000 lx), medium(Me;400 lx) and low(Lo;50 lx) light intensities under a 12:12 light/dark cycle for 6 wk. Each group was subdivided into subgroups with the following spectra: broad spectrum Solux halogen light(BS), 600 nm above-filtered continuous spectrum(600F), 530 nm above-filtered continuous spectrum(530F), and 480 nm above-filtered continuous spectrum(480F;HiBS: n=10, Hi600F: n=10, Hi530F: n=10, Hi480F: n=10, MeBS: n=10, Me600F: n=10, Me530F: n=10, Me480F: n=10, LoBS: n=11, Lo600F: n=12, Lo530F: n=10, Lo480F: n=11). Refractive error, corneal curvature radius, and axial dimensions were determined by cycloplegic retinoscopy, photokeratometry, and A-scan ultrasonography before and after 2, 4, and 6 wk of treatment. Average changes from both eyes in the ocular parameters and refractive error were compared among different subgroups.RESULTS: After 6 wk of exposure, high-intensity lighting enhanced hyperopic shift;medium-and low-intensity lighting enhanced myopic shift(P<0.05). Under the same spectrum, axial increase was larger in the low light intensity group than in the medium and high light intensity groups(HiBS: 0.65±0.02 mm, MeBS: 0.67±0.01 mm, LoBS:0.82±0.02 mm;Hi600 F: 0.64±0.02 mm, Me600F: 0.67±0.01 mm, Lo600F: 0.81±0.01 mm;Hi530F: 0.64±0.02 mm, Me530F: 0.67±0.01 mm, Lo530F: 0.73±0.02 mm;Hi480F: 0.64±0.01 mm, Me480F: 0.66±0.01 mm, Lo480F: 0.72±0.02 mm;P<0.05). Under 400 lx, there was a faster axial increase in the MeBS group than in the Me480F group(P<0.05). Under 50 lx, axial length changes were significantly larger in LoBS and Lo600F than in Lo530F and Lo480F(P<0.01).CONCLUSION: Under high-intensity lighting, high light intensity rather than spectrum distributions that inhibits axial increase. Under medium-and low-intensity lighting, filtering out the long wavelength inhibits axial growth in juvenile guinea pigs. 展开更多
关键词 MYOPIA WAVELENGTH SPECTRAL composition light INTENSITY refractive development
下载PDF
Refractive surgery: the most cost-saving technique in refractive errors correction 被引量:2
20
作者 Seyed-Farzad Mohammadi Cyrus Alinia +2 位作者 Maryam Tavakkoli Alireza Lashay Hormoz Chams 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第6期1013-1019,共7页
AIM: To compare the lifetime and annual economic burden of spectacles, contact lenses, and refractive surgery in correction of refractive errors.METHODS: This is a cross-sectional study with convenience sampling whi... AIM: To compare the lifetime and annual economic burden of spectacles, contact lenses, and refractive surgery in correction of refractive errors.METHODS: This is a cross-sectional study with convenience sampling which 120 patients were interviewed in a tertiary referral hospital in the Iranian health care system. The bottom-up based cost of illness approach was estimated using a face-to-face interview to assess the direct and indirect cost of different refractive errors correction of any correction technologies. RESULTS: Correction with spectacle imposes a total direct cost of US dollar (US$) 342.5 (±8.41) per year and US$9373.5 (±230.1) per lifetime to each patient. These figures for the contact lenses were obtained US$198.3 (±0.12) and US$5203.1 (±256.3) and for refractive surgery were obtained US$19.1 (±1.2) and US$568.1 (±64.6), respectively. Overall, based on age-adjusted prevalence rates, astigmatism had the highest share of refractive errors economic burden with a lifetime direct cost of slightly less than US$5.49 billion, while hyperopia and myopia imposed less than US$5.24 and 4.2 billion on patients, respectively. The annually imposed cost on each individual Iranian patient with refractive errors is US$308.5. CONCLUSION: Based on 18mo post refractive surgery course observation, which is generalized to whole life, refractive surgery significantly imposed much less cost compared with spectacles and contact lenses. Refractive errors among Iranians result in considerable economic burden. Using the refractive surgery instead of other two correction methods has the ability to reduce this economic loss in the future. 展开更多
关键词 refractive error economic burden refractive surgery SPECTACLE contact lenses
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部