期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Analysis of changes in crystalline lens thickness and its refractive power after laser in situ keratomileusis 被引量:5
1
作者 Liang Wang, Hai-Ying Jin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期97-101,共5页
AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperat... AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperative central ACD which were measured with Pentacam, Orbscan, IOL-Master and A-scan ultrasonography, central corneal true net power which was measured with the Pentacam, Orbscan and IOL-Master, axial length (AL) which was measured with IOL-Master and LT which was measured with the A-scan ultrasonography were compared using the paired sample t test. Ocular refractive errors and lens refractive power at corneal plane were calculated and their correlations were also evaluated before and after LASIK. RESULTS: At 1 week after LASIK, LT and crystalline lens refractive power at corneal plane (Dlens) which were associated with the IOL-Master and Pentacam increased significantly (P <= 0.005), ACD decreased significantly (P <= 0.001), but no significant increase was observed in the Diens which was associated with the Orbscan(P=0.261). Significant correlations between the changes in the ocular refractive errors and Diens which were associated with the Pentacam were observed at 1 week and 6 months after LASIK (P = 0.028; P=0.001). CONCLUSION: LT increased significantly after LASIK, and this might partially lead to ACD decrease, Diens increase and a small quantity of myopic regression. 展开更多
关键词 anterior chamber depth crystalline lens thickness refractive power
下载PDF
A novel analysis of Scheimpflug total corneal refractive power following corneal cross-linking in mild to moderate keratoconus
2
作者 Chao Pan Wei-Na Tan +7 位作者 Dan Chen Yu Liu Hao-Yu Wang Deng-Feng Liang Yan-Jun Hua Xiao-Hua Lei Qing-Yan Zeng Shao-Zhen Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第5期728-735,共8页
AIM:To detect an earlier improvement in mild to moderate keratoconus following corneal cross-linking(CXL)with total corneal refractive power(TCRP)using ray tracing method.METHODS:A total of 40 eyes of 30 consecutive p... AIM:To detect an earlier improvement in mild to moderate keratoconus following corneal cross-linking(CXL)with total corneal refractive power(TCRP)using ray tracing method.METHODS:A total of 40 eyes of 30 consecutive patients who underwent CXL for progressive keratoconus were retrospectively enrolled.The following keratometric parameters provided by Pentacam HR,including maximum keratometry(Kmax),steepest keratometry(Ksteep),3 mm zonal TCRP centered over corneal apex(TCRPapex,zone 3 mm),zonal mean keratometry and TCRP centered over corneal cone(Kmcone,zone and TCRPcone,zone 1,2,3 mm)were evaluated preoperatively and 1,3,6,and 12 mo postoperatively.Groups 1 and 2 were defined based on Kmax at postoperative 1 mo as improved(the initial improvement group)or worsen(the initial deterioration group)compared to the preoperative level.RESULTS:In the overall group,only keratometric parameters based on ray tracing method displayed significant improvement early at 3 mo postoperatively,in which TCRPcone,zone 1 mm and 2 mm exhibited the largest flattening(0.57 D and 0.53 D,respectively).In Group 1,only Kmax,Kmcone,zone 2 mm and TCRPcone,zone 2 mm showed significant improvement initially at 1 mo postoperatively,in which Kmax exhibited the largest improvement(1.05 D),followed by TCRPcone,zone 2 mm(0.82 D).In Group 2,only keratometric parameters based on ray tracing method and Kmcone,zone 3 mm showed slight but not significant improvement early at 3 mo,in which TCRPcone,zone 3 mm displayed the most improvement(0.19 D),followed by TCRPcone,zone 2 mm(0.15 D).CONCLUSION:The findings indicate that a 2 mm zonal TCRP centered over Kmax could earlier detect keratometric improvement by CXL compared to other commonly used parameters in mild to moderate keratoconic eyes. 展开更多
关键词 KERATOCONUS corneal cross-linking KERATOMETRY total corneal refractive power ray tracing
下载PDF
Evaluation of axial length/total corneal refractive power ratio as a potential marker for ocular diagnosis of Marfan’s syndrome in children
3
作者 Tian-Hui Chen Ai-Zhu Miao +6 位作者 Yu-Liang Wang Min Zhang Jia-Hui Chen Jia-Lei Zheng Michael Deng Ying-Hong Ji Yong-Xiang Jiang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第8期1218-1224,共7页
AIM:To investigate whether the axial length(AL)/total corneal refractive power(TCRP)ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan’s syndrome(MFS)in children.METHODS:The rel... AIM:To investigate whether the axial length(AL)/total corneal refractive power(TCRP)ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan’s syndrome(MFS)in children.METHODS:The relationship between the AL/TCRP ratio and the diagnosis of MFS for 192 eyes in 97 children were evaluate.The biological characteristics,including age,sex,AL,and TCRP,were collected from medical records.Receiver operating characteristic(ROC)curve analysis was performed to investigate whether the AL/TCRP ratio effectively distinguishes MFS from other subjects.The Youden index was used to re-divide the whole population into two groups according to an AL/TCRP ratio of 0.59.RESULTS:Of 96 subjects(mean age 7.46±3.28 y)evaluated,56(110 eyes)had a definite diagnosis of MFS in childhood based on the revised Ghent criteria,41(82 eyes)with diagnosis of congenital ectopia lentis(EL)were included as a control group.AL was negatively correlated with TCRP,with a linear regression coefficient of-0.36(R2=0.08).A significant correlation was found between age and the AL/TCRP ratio(P=0.023).ROC curve analysis showed that the AL/TCRP ratio distinguished MFS from the other patients at a threshold of 0.59.MFS patients were present in 24/58(41.38%)patients with an AL/TCRP ratio of≤0.59 and in 34/39(87.18%)patients with an AL/TCRP ratio of>0.59.CONCLUSION:An AL/TCRP ratio of>0.59 is significantly associated with the risk of MFS.The AL/TCRP ratio should be measured as a promising marker for the prognosis of children MFS.Changes in the AL/TCRP ratio should be monitored over time. 展开更多
关键词 axial length total corneal refractive power ratio DIAGNOSIS Marfan’s syndrome CHILDREN
下载PDF
Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses 被引量:2
4
作者 Eleni Papadatou Antonio J.Del Aguila-Carrasco +2 位作者 Jose J.Esteve-Taboada David Madrid-Costa Alejandro Cervino-Exposito 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期103-108,共6页
AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one mul... AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed.RESULTS: The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about ?3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens.CONCLUSION: In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient’s visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome. 展开更多
关键词 multifocal contact lenses pupil size power profiles refractive power distribution
下载PDF
Self-calibrated global rainbow refractometry:a dual-wavelength approach 被引量:2
5
作者 吴学成 姜淏予 +5 位作者 操凯霖 吴迎春 李灿 Gérard Gréhan Sawitree Saengkaew 岑可法 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第4期68-72,共5页
Calibration of the relationship between the scattering angle and the CCD pixel is a key part of achieving accurate measurements of rainbow refractometry.A novel self-calibrated global rainbow refractometry system base... Calibration of the relationship between the scattering angle and the CCD pixel is a key part of achieving accurate measurements of rainbow refractometry.A novel self-calibrated global rainbow refractometry system based on illumination by two lasers of different wavelengths is proposed.The angular calibration and refractive index measurement of two wavelengths can be completed simultaneously without extra measurement devices.The numerical and experimental results show the feasibility and high precision of the self-calibration method,which enables the rainbow refractometry to be implemented in a more powerful and convenient way.The self-calibrated rainbow system is successfully applied to measure the refractive indices of ethanol-water solutions with volume concentrations of 10% to 60%. 展开更多
关键词 calibration illumination refractive pixel completed powerful calibrated mirror indices ethanol
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部