A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch...A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch, such as the ratio and distribution of vapor and liquid, due to the differences in densities and momentums of vapor and liquid in the two-phase flow make equal distribution difficult. This paper describes the distribution characteristics of a four-branch header that has a rectangular cross-section without the internal protrusion of flat tubes in the case of the inflow of the refrigerant R32 from the bottom of the header by using an equipment that can estimate the distribution ratio of the liquid and vapor phase to each branch. This paper also discusses the distribution characteristics on the basis of the flow visualization in the header. The flow visualization shows that a liquid level that contains vapor phase exists in the header and affects the distribution greatly.展开更多
The refrigerant flow distribution in the parallel flow microchannel evaporators is experimentally investigated to study the effect of header configuration.Six different configurations are tested in the same evaporator...The refrigerant flow distribution in the parallel flow microchannel evaporators is experimentally investigated to study the effect of header configuration.Six different configurations are tested in the same evaporator by installing insertion device and partition plate in the header to ensure the consistency of the other structure parameters.The results show that the uniformity of refrigerant flow distribution and the heat transfer rate are greatly improved by reducing the sectional area of header.The heat transfer rate can increase by 67.93%by reducing the sectional area of both inlet and outlet headers.The uniformity of refrigerant flow distribution and the heat transfer rate become worse after installing the partition plate in the insertion devices and changing the inner structure of the header further.展开更多
This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data cen...This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems.展开更多
文摘A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch, such as the ratio and distribution of vapor and liquid, due to the differences in densities and momentums of vapor and liquid in the two-phase flow make equal distribution difficult. This paper describes the distribution characteristics of a four-branch header that has a rectangular cross-section without the internal protrusion of flat tubes in the case of the inflow of the refrigerant R32 from the bottom of the header by using an equipment that can estimate the distribution ratio of the liquid and vapor phase to each branch. This paper also discusses the distribution characteristics on the basis of the flow visualization in the header. The flow visualization shows that a liquid level that contains vapor phase exists in the header and affects the distribution greatly.
基金the Key Industry Common Key-Technology Innovation Project of Chongqing Municipal Science and Committee(No.cstc2015zdcy-ztzx60001)
文摘The refrigerant flow distribution in the parallel flow microchannel evaporators is experimentally investigated to study the effect of header configuration.Six different configurations are tested in the same evaporator by installing insertion device and partition plate in the header to ensure the consistency of the other structure parameters.The results show that the uniformity of refrigerant flow distribution and the heat transfer rate are greatly improved by reducing the sectional area of header.The heat transfer rate can increase by 67.93%by reducing the sectional area of both inlet and outlet headers.The uniformity of refrigerant flow distribution and the heat transfer rate become worse after installing the partition plate in the insertion devices and changing the inner structure of the header further.
基金Thanks for the support of Hunan postdoctoral fund(Number:198514)。
文摘This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems.