期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Refrigerant Distribution Characteristics in Vertical Header of Flat-Tube Heat Exchanger without Internal Protrusion
1
作者 Kazuhiro Endoh 《Journal of Energy and Power Engineering》 2017年第10期655-664,共10页
A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch... A heat exchanger that arranges flat tubes horizontally has a vertical header that distributes the refrigerant to each tube. When the heat exchanger works as an evaporator, differences in flow conditions at each branch, such as the ratio and distribution of vapor and liquid, due to the differences in densities and momentums of vapor and liquid in the two-phase flow make equal distribution difficult. This paper describes the distribution characteristics of a four-branch header that has a rectangular cross-section without the internal protrusion of flat tubes in the case of the inflow of the refrigerant R32 from the bottom of the header by using an equipment that can estimate the distribution ratio of the liquid and vapor phase to each branch. This paper also discusses the distribution characteristics on the basis of the flow visualization in the header. The flow visualization shows that a liquid level that contains vapor phase exists in the header and affects the distribution greatly. 展开更多
关键词 refrigerant distribution vapor-liquid two-phase flow HEADER flat tube heat exchanger.
下载PDF
Effect of Header Configuration on Refrigerant Distribution in Parallel Flow Microchannel Evaporators 被引量:3
2
作者 YU Dengjia LIU Jinwei +3 位作者 Lü Hongbin SHI Junye YOU Dian CHEN Jiangping 《Journal of Shanghai Jiaotong university(Science)》 EI 2019年第3期273-280,共8页
The refrigerant flow distribution in the parallel flow microchannel evaporators is experimentally investigated to study the effect of header configuration.Six different configurations are tested in the same evaporator... The refrigerant flow distribution in the parallel flow microchannel evaporators is experimentally investigated to study the effect of header configuration.Six different configurations are tested in the same evaporator by installing insertion device and partition plate in the header to ensure the consistency of the other structure parameters.The results show that the uniformity of refrigerant flow distribution and the heat transfer rate are greatly improved by reducing the sectional area of header.The heat transfer rate can increase by 67.93%by reducing the sectional area of both inlet and outlet headers.The uniformity of refrigerant flow distribution and the heat transfer rate become worse after installing the partition plate in the insertion devices and changing the inner structure of the header further. 展开更多
关键词 refrigerant distribution HEADER microchannel evaporator two-phase flow
原文传递
Finite time thermodynamic analysis and optimization of water cooled multi-spilit heat pipe system(MSHPS)
3
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Energy and Built Environment》 2022年第3期373-383,共11页
This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data cen... This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems. 展开更多
关键词 Thermodynamic simulation Finite time thermodynamic analysis Exergy method IDC room Heat pipe air-conditioning system SIMULINK software refrigerant flow distribute characteristic Energy saving potential
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部