期刊文献+
共找到23,665篇文章
< 1 2 250 >
每页显示 20 50 100
Numerical simulation of melt flow and temperature field during DC casting 2024 aluminium alloy under different casting conditions
1
作者 Jin-chuan Wang Yu-bo Zuo +3 位作者 Qing-feng Zhu Jing Li Rui Wang Xu-dong Liu 《China Foundry》 SCIE EI CAS CSCD 2024年第4期387-396,共10页
Casting speed,casting temperature and secondary cooling water flow rate are the main process parameters affecting the DC casting process.These parameters significantly influence the flow and temperature fields during ... Casting speed,casting temperature and secondary cooling water flow rate are the main process parameters affecting the DC casting process.These parameters significantly influence the flow and temperature fields during casting,which are crucial for the quality of the ingot and can determine the success or failure of the casting operation.Numerical simulation,with the advantages of low cost,rapid execution,and visualized results,is an important method to study and optimize the DC casting process.In the present work,a simulation model of DC casting 2024 aluminum alloy was established,and the reliability of the model was verified.Then,the influence of casting parameters on flow field and temperature field was studied in detail by numerical simulation method.Results show that with the increase of casting speed,the melt flow becomes faster,the depths of slurry zone and mushy zone increase,and the variation of slurry zone depth is greater than that of mushy zone.With an increase in casting temperature,the melt flow rate increases,the depth of the slurry zone becomes shallower,and the depth of the mushy zone experiences only minor changes.The simulation results further indicate that the increase of the flow rate of the secondary cooling water slightly reduces the depths of both slurry and mushy zone. 展开更多
关键词 aluminium DC casting flow field temperature field numerical simulation
下载PDF
Stability analysis of a liquid crystal elastomer self-oscillator under a linear temperature field
2
作者 Haiyang WU Jiangfeng LOU +2 位作者 Biao ZHANG Yuntong DAI Kai LI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第2期337-354,共18页
Self-oscillating systems abound in the natural world and offer substantial potential for applications in controllers,micro-motors,medical equipments,and so on.Currently,numerical methods have been widely utilized for ... Self-oscillating systems abound in the natural world and offer substantial potential for applications in controllers,micro-motors,medical equipments,and so on.Currently,numerical methods have been widely utilized for obtaining the characteristics of self-oscillation including amplitude and frequency.However,numerical methods are burdened by intricate computations and limited precision,hindering comprehensive investigations into self-oscillating systems.In this paper,the stability of a liquid crystal elastomer fiber self-oscillating system under a linear temperature field is studied,and analytical solutions for the amplitude and frequency are determined.Initially,we establish the governing equations of self-oscillation,elucidate two motion regimes,and reveal the underlying mechanism.Subsequently,we conduct a stability analysis and employ a multi-scale method to obtain the analytical solutions for the amplitude and frequency.The results show agreement between the multi-scale and numerical methods.This research contributes to the examination of diverse self-oscillating systems and advances the theoretical analysis of self-oscillating systems rooted in active materials. 展开更多
关键词 SELF-OSCILLATION stability analysis multi-scale method liquid crystal elastomer linear temperature field
下载PDF
Investigation on Temperature Field Calibration and Analysis of Wind Tunnel
3
作者 Zhaokun Ren Zhanyuan Ma +3 位作者 Yue Zhang Hongda Xu Yunxiang Wang Hui Xu 《Journal of Harbin Institute of Technology(New Series)》 CAS 2024年第3期63-79,共17页
For wind tunnels,it is essential to conduct temperature and flow field calibration on their test section,which is an important indicator for evaluating the quality of wind tunnel flow fields.In the paper,a truss compo... For wind tunnels,it is essential to conduct temperature and flow field calibration on their test section,which is an important indicator for evaluating the quality of wind tunnel flow fields.In the paper,a truss composed of temperature sensors was used to calibrate the temperature field of a completed wind tunnel section.By adjusting the distance between the temperature measurement truss and the nozzle,as well as the wind speed,the temperature field distribution data at different positions could be obtained.Analyze these data to identify important factors that affect the distribution of temperature field.Simultaneously,the temperature field of the wind tunnel was simulated accordingly.The purpose is to further analyze the fluid heat transfer between air and wind tunnel walls through numerical simulation.Through the above analysis methods,the quality of the temperature field in the wind tunnel has been further verified,providing reference for future wind tunnel tests of relevant models. 展开更多
关键词 wind tunnel temperature field numerical simulation fluid heat transfer
下载PDF
An Explanation of the Temperature-Dependent Upper Critical Field Data of H3S on the Basis of the Thermodynamics of a Superconductor in a Magnetic Field
4
作者 Gulshan Prakash Malik 《World Journal of Condensed Matter Physics》 CAS 2024年第3期45-50,共6页
Excellent fits to a couple of the data-sets on the temperature (T)-dependent upper critical field (Hc2) of H3S (critical temperature, Tc ≈ 200 K at pressure ≈ 150 GPa) reported by Mozaffari, et al. (2019) were obtai... Excellent fits to a couple of the data-sets on the temperature (T)-dependent upper critical field (Hc2) of H3S (critical temperature, Tc ≈ 200 K at pressure ≈ 150 GPa) reported by Mozaffari, et al. (2019) were obtained by Talantsev (2019) in an approach based on an ingenious mix of the Ginzberg-Landau (GL), the Werthamer, Helfand and Hohenberg (WHH), and the Gor’kov, etc., theories which have individually been employed for the same purpose for a long time. Up to the lowest temperature (TL) in each of these data-sets, similarly accurate fits have also been obtained by Malik and Varma (2023) in a radically different approach based on the Bethe-Salpeter equation (BSE) supplemented by the Matsubara and the Landau quantization prescriptions. For T TL, however, while the (GL, WHH, etc.)-based approach leads to Hc2(0) ≈ 100 T, the BSE-based approach leads to about twice this value even at 1 K. In this paper, a fit to one of the said data-sets is obtained for the first time via a thermodynamic approach which, up to TL, is as good as those obtained via the earlier approaches. While this is interesting per se, another significant result of this paper is that for T TL it corroborates the result of the BSE-based approach. 展开更多
关键词 H3S Upper Critical field (Hc2) Variation of Hc2 with temperature Clausius-Clapeyron equation in a magnetic field Behavior of Hc2 for temperatures Close to 0 K
下载PDF
Temperature field calculation of rail flash welding
5
作者 Rui Xu Min Zhang +6 位作者 Zhenkun Gao Guo Zhao Wei Ding Shouming Wang Peng Zhang Xiang Liu Jingjing Li 《High-Speed Railway》 2024年第2期116-121,共6页
The forging stage of rail flash welding has a decisive influence on joint strength,and the study of the temperature distribution in the process has an important role in further improving joint strength.In this paper,t... The forging stage of rail flash welding has a decisive influence on joint strength,and the study of the temperature distribution in the process has an important role in further improving joint strength.In this paper,three calculation methods for the temperature field are given.First,the finite element model of the temperature field before forging rail flash welding is established by using the transient heat module of Ansys software and verified by infrared temperature measurement.Second,the temperature distribution of different parts of the rail before flash welding is obtained by using infrared thermal imaging equipment.Third,Matlab software is used to calculate the temperature of the non-measured part.Finally,the temperature distribution function along the rail axis is fitted through the temperature measurement data.The temperature distribution before the top forging of the rail flash welding can be used to analyze the joint and heat-affected zone organization and properties effectively and to guide the parameter setting and industrial production. 展开更多
关键词 Flash welding temperature field Joint strength Software calculation
下载PDF
Interfacial built-in electric field and crosslinking pathways enabling WS_(2)/Ti_(3)C_(2)T_(x) heterojunction with robust sodium storage at low temperature
6
作者 Jiabao Li Shaocong Tang +6 位作者 Jingjing Hao Quan Yuan Tianyi Wang Likun Pan Jinliang Li Shenbo Yang Chengyin Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第2期635-645,I0014,共12页
Developing efficient energy storage for sodium-ion batteries(SIBs)by creating high-performance heterojunctions and understanding their interfacial interaction at the atomic/molecular level holds promise but is also ch... Developing efficient energy storage for sodium-ion batteries(SIBs)by creating high-performance heterojunctions and understanding their interfacial interaction at the atomic/molecular level holds promise but is also challenging.Besides,sluggish reaction kinetics at low temperatures restrict the operation of SIBs in cold climates.Herein,cross-linking nanoarchitectonics of WS_(2)/Ti_(3)C_(2)T_(x) heterojunction,featuring built-in electric field(BIEF),have been developed,employing as a model to reveal the positive effect of heterojunction design and BIEF for modifying the reaction kinetics and electrochemical activity.Particularly,the theoretical analysis manifests the discrepancy in work functions leads to the electronic flow from the electron-rich Ti_(3)C_(2)T_(x) to layered WS_(2),spontaneously forming the BIEF and“ion reservoir”at the heterogeneous interface.Besides,the generation of cross-linking pathways further promotes the transportation of electrons/ions,which guarantees rapid diffusion kinetics and excellent structure coupling.Consequently,superior sodium storage performance is obtained for the WS_(2)/Ti_(3)C_(2)T_(x) heterojunction,with only 0.2%decay per cycle at 5.0 A g^(-1)(25℃)up to 1000 cycles and a high capacity of 293.5 mA h g^(-1)(0.1A g^(-1)after 100 cycles)even at-20℃.Importantly,the spontaneously formed BIEF,accompanied by“ion reservoir”,in heterojunction provides deep understandings of the correlation between structure fabricated and performance obtained. 展开更多
关键词 WS_(2)/Ti_(3)C_(2)T_(x)heterojunction Built-in electric field Ion reservoir Reaction kinetics Sodium storage performance at low temperature
下载PDF
Temperature field model in surface grinding: a comparative assessment 被引量:4
7
作者 Min Yang Ming Kong +10 位作者 Changhe Li Yunze Long Yanbin Zhang Shubham Sharma Runze Li Teng Gao Mingzheng Liu Xin Cui Xiaoming Wang Xiao Ma Yuying Yang 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第4期314-373,共60页
Grinding is a crucial process in machining workpieces because it plays a vital role in achieving the desired precision and surface quality.However,a significant technical challenge in grinding is the potential increas... Grinding is a crucial process in machining workpieces because it plays a vital role in achieving the desired precision and surface quality.However,a significant technical challenge in grinding is the potential increase in temperature due to high specific energy,which can lead to surface thermal damage.Therefore,ensuring control over the surface integrity of workpieces during grinding becomes a critical concern.This necessitates the development of temperature field models that consider various parameters,such as workpiece materials,grinding wheels,grinding parameters,cooling methods,and media,to guide industrial production.This study thoroughly analyzes and summarizes grinding temperature field models.First,the theory of the grinding temperature field is investigated,classifying it into traditional models based on a continuous belt heat source and those based on a discrete heat source,depending on whether the heat source is uniform and continuous.Through this examination,a more accurate grinding temperature model that closely aligns with practical grinding conditions is derived.Subsequently,various grinding thermal models are summarized,including models for the heat source distribution,energy distribution proportional coefficient,and convective heat transfer coefficient.Through comprehensive research,the most widely recognized,utilized,and accurate model for each category is identified.The application of these grinding thermal models is reviewed,shedding light on the governing laws that dictate the influence of the heat source distribution,heat distribution,and convective heat transfer in the grinding arc zone on the grinding temperature field.Finally,considering the current issues in the field of grinding temperature,potential future research directions are proposed.The aim of this study is to provide theoretical guidance and technical support for predicting workpiece temperature and improving surface integrity. 展开更多
关键词 grinding temperature uniform continuous temperature field nonuniform discontinuous temperature field heat source distribution model grinding heat distribution coefficient model convective heat transfer coefficient model
下载PDF
Calculation of Mass Concrete Temperature and Creep Stress under the Influence of Local Air Heat Transfer
8
作者 Heng Zhang Chao Su +2 位作者 Xiaohu Chen Zhizhong Song Weijie Zhan 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第9期2977-3000,共24页
Temperature-induced cracking during the construction of mass concrete is a significant concern.Numerical simulations of concrete temperature have primarily assumed that the concrete is placed in an open environment.Th... Temperature-induced cracking during the construction of mass concrete is a significant concern.Numerical simulations of concrete temperature have primarily assumed that the concrete is placed in an open environment.The problem of heat transfer between the air and concrete has been simplified to the concrete’s heat dissipation boundary.However,in the case of tubular concrete structures,where air inlet and outlet are relatively limited,the internal air temperature does not dissipate promptly to the external environment as it rises.To accurately simulate the temperature and creep stress in tubular concrete structures with enclosed air spaces during construction,we establish an air–concrete coupled heat transfer model according to the principles of conjugate heat transfer,and the accuracy of the model is verified through experiments.Furthermore,we conduct a case study to analyze the impact of airflow within the ship lock corridor on concrete temperature and creep stress.The results demonstrate that enhancing airflow within the corridor can significantly reduce the maximum concrete temperature.Compared with cases in which airflow within the corridor is neglected,the maximum concrete temperature and maximum tensile stress can be reduced by 12.5℃ and 0.7 MPa,respectively,under a wind speed of 4 m/s.The results of the traditional calculation method are relatively close to those obtained at a wind speed of 1 m/s.However,the temperature reduction process in the traditional method is faster,and the method yields greater tensile stress values for the corridor location. 展开更多
关键词 Conjugate heat transfer temperature field mass concrete creep stress
下载PDF
Effects of vacuum magnetic field region on the compact torus trajectory in a tokamak plasma
9
作者 董期龙 张洁 +28 位作者 兰涛 肖持进 庄革 陈晨 周永康 吴捷 龙婷 聂林 卢鹏程 王天雄 邬佳仁 邓鹏 汪兴康 柏泽琪 黄玉华 李杰 薛雷 阿迪力江 毛文哲 周楚 刘阿娣 吴征威 谢锦林 丁卫星 刘万东 陈伟 钟武律 许敏 段旭如 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期23-39,共17页
The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tok... The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tokamak discharges.This model was used to calculate the trajectory and penetration parameters of CT injections by applying both perpendicular and tangential injection schemes in both HL-2A and ITER tokamaks.For perpendicular injection along the tokamak's major radius direction from the outboard,CTs with the same injection parameters exhibited a 0.08 reduction in relative penetration depth when injected into HL-2A and a 0.13reduction when injected into ITER geometry when considering the vacuum magnetic field region compared with cases where this region was not considered.In addition,we proposed an optimization method for determining the CT's initial injection velocity to accurately calculate the initial injection velocity of CTs for central fueling in tokamaks.Furthermore,this paper discusses schemes for the tangential injection of CT into tokamak discharges.The optimal injection angle and CT magnetic moment direction for injection into both HL-2A and ITER were determined through numerical simulations.Finally,the kinetic energy loss occurring when the CT penetrated the vacuum magnetic field region in ITER was reduced byΔEk=975.08 J by optimizing the injection angle for the CT injected into ITER.These results provide valuable insights for optimizing injection angles in fusion experiments.Our model closely represents actual experimental scenarios and can assist the design of CT parameters. 展开更多
关键词 compact torus central fueling vacuum magnetic field region penetration mechanism optimization parameters
下载PDF
Characteristics of the SOL ion-to-electron temperature ratio on the J-TEXT tokamak with different plasma configurations
10
作者 李存凯 梁云峰 +16 位作者 江中和 周松 华建坤 阳杰 杨庆虎 Alexander KNIEPS Philipp DREWS 徐鑫 毛飞越 谢伟 杨雨桐 郭金龙 李杨波 任正康 陈志鹏 王能超 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期13-21,共9页
Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and d... Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and divertor plasma transport in magnetically confined fusion research.On the J-TEXT tokamak,a multi-channel retarding field analyzer(RFA) probe has been developed to study average plasma parameters in the edge region under various poloidal divertor and island divertor configurations.The edge radial profile of the ion-to-electron temperature ratio,τ_(i/e),has been determined,which gradually decreases as the SOL ion self-collisionality,v_(SOL)*,increases.This is broadly consistent with what has been observed previously from various tokamak experiments.However,the comparison of experimental results under different configurations shows that in the poloidal divertor configuration,even under the same v_(SOL)*,τ_(i/e) in the SOL region becomes smaller as the distance from the X-point to the target plate increases.In the island divertor configuration,τ_(i/e) near the O-point is higher than that near the X-point at the same v_(SOL)*,and both are higher than those in the limiter configuration.These results suggest that the magnetic configuration plays a critical role in the energy distributions between electrons and ions at the plasma boundary. 展开更多
关键词 ion temperature island divertor poloidal divertor retarding field analyzer(RFA)probe
下载PDF
The Effects of Thickness and Location of PCMon the Building’s Passive Temperature-Control–A Numerical Study
11
作者 Zhengrong Shi JieRen +1 位作者 Tao Zhang Yanming Shen 《Energy Engineering》 EI 2024年第3期681-702,共22页
Building energy consumption and building carbon emissions both account for more than 20%of their total national values in China.Building employing phase change material(PCM)for passive temperature control shows a prom... Building energy consumption and building carbon emissions both account for more than 20%of their total national values in China.Building employing phase change material(PCM)for passive temperature control shows a promising prospect in meeting the comfort demand and reducing energy consumption simultaneously.However,there is a lack of more detailed research on the interaction between the location and thickness of PCM and indoor natural convection,as well as indoor temperature distribution.In this study,the numerical model of a passive temperature-controlled building integrating the developed PCM module is established with the help of ANSYS.In which,the actual weather condition of Beijing city is set as the boundary conditions and the indoor natural convection is simulated with the consideration of radiation model.The effects of PCM’s thickness and location on the internal temperature field are analyzed and discussed.The results show that the room could maintain within the human comfort temperature range with the longest ratio of 94.10%and the shortest ratio of 51.04%as integrating PCM.In comparison,the value is only 26.70%without PCM.The room’s maximum temperature fluctuation can also be improved;it could be lowered by 64.4%compared to the normal condition.When the quantity of PCM is sufficient,further increasing the PCM amount results in a temperature fluctuation reduction of less than 0.1°C and does not increase the comfort time.Placing PCM on the wall induces an apparent variation in indoor temperature along the vertical direction.Conversely,placing PCM on the roof can lead to a heat transfer rate difference of up to seven times.The optimal placement of PCM depends on the difference between the environmental and phase change temperatures.If the difference is positive,placing PCM on the roof is more effective;conversely,the opposite holds.According to the results over the entire cycle,PCM application on vertical walls yields better performance.The significant difference in natural convection caused by the same thickness of PCM but different application positions,coupled with the influence of air movement on the melting and solidification of PCM,further impacts indoor temperature fluctuations and comfort.This study can provide guidance for the application location and thickness of PCM,especially for scenarios where temperature regulation is required at a specific time. 展开更多
关键词 Phase change materials passive temperature regulation numerical simulation temperature field
下载PDF
Study of the geomagnetic field's regional gradients in Chinese continent using three-dimensional surface Spline model
12
作者 Yan Feng YiJun Li +3 位作者 JinYan Zhang Shuang Liu Abbas Nasir Ya Huang 《Earth and Planetary Physics》 EI CSCD 2023年第1期74-83,共10页
We combined domestic ground-based and satellite magnetic measurements to create a regional three-dimensional surface Spline(3DSS)gradient model of the main geomagnetic field over the Chinese continent.To improve the p... We combined domestic ground-based and satellite magnetic measurements to create a regional three-dimensional surface Spline(3DSS)gradient model of the main geomagnetic field over the Chinese continent.To improve the precision of the model,we considered the data gap between the ground and satellite data.We compared and analyzed the results of the Taylor polynomial,surface Spline,and CHAOS-6(the CHAMP,?rsted and SAC-C model of Earth’s magnetic field)gradient models.Results showed that the gradients in the south-north and east-west directions of the four models were consistent.The 3DSS model was able to express not only gradients at different altitudes,but also average gradients inside the research area.The two Spline models were able to capture more information on gradient anomalies than were the fitted models.Strong local anomalies were observed in northern Xinjiang,Beijing,and the junction area between Jiangsu and Zhejiang,and the total intensity F decreased whereas the altitude increased.The gradient decreased by 21.69%in the south-north direction and increased by 11.78%in the east-west direction.In addition,the altitude gradient turned from negative to positive while the altitude increased.The Spline model and the two fitted models differed mainly in the field sources they expressed and the modeling theory. 展开更多
关键词 geomagnetic field main field gradients regional model three-dimensional modeling
下载PDF
Temperature Field in Laser Line Scanning Thermography: Analytical Calculation and Experiment
13
作者 Yin Li Yuanjia Song +2 位作者 Zhengwei Yang Haijun Jiang Bowen Liu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第10期1001-1018,共18页
The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analy... The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analyzed.On this basis,a physical laser line scanning model is proposed.Afterwards,based on Fourier transform(FT)and segregation variablemethod(SVM),the heat conduction differential equation in laser line scanning thermography is derived in detail.The temperature field of the composite-based coatings model with defects is simulated numerically.The results show that the laser line scanning thermography can effectively detect the defects in the model.The correctness of the analytical calculation is verified by comparing the surface temperature distribution obtained by analytical calculation and numerical simulation.Additionally,an experiment is carried out and the changeable surface temperature obtained by analytical calculation is compared with the experimental results.It shows that the error of maximum temperature obtained by analytical calculation and by experiment is 8%with high accuracy,which proves the correctness of analytical calculation and enriches the theoretical foundation of laser line scanning thermography. 展开更多
关键词 temperature field laser line scanning thermography analytical calculation numerical simulation EXPERIMENT
下载PDF
Thermal Properties Reconstruction and Temperature Fields in Asphalt Pavements: Inverse Problem and Optimisation Algorithms
14
作者 Zhonghai Jiang Qian Wang +1 位作者 Liangbing Zhou Chun Xiao 《Fluid Dynamics & Materials Processing》 EI 2023年第6期1693-1708,共16页
A two-layer implicit difference scheme is employed in the present study to determine the temperature distribution in an asphalt pavement.The calculation of each layer only needs four iterations to achieve convergence.... A two-layer implicit difference scheme is employed in the present study to determine the temperature distribution in an asphalt pavement.The calculation of each layer only needs four iterations to achieve convergence.Furthermore,in order to improve the calculation accuracy a swarm intelligence optimization algorithm is also exploited to inversely analyze the laws by which the thermal physical parameters of the asphalt pavement materials change with temperature.Using the basic cuckoo and the gray wolf algorithms,an adaptive hybrid optimization algorithm is obtained and used to determine the relationship between the thermal diffusivity of two types of asphalt pavement materials and the temperature.As shown by the results,the prediction accuracy achievable with this approach is higher than that of the linear model. 展开更多
关键词 Asphalt pavement temperature field swarm intelligence optimization algorithm PREDICTION
下载PDF
Numerical analysis for permafrost temperature field in the short term of permafrost subgrade filling
15
作者 Yunjia Wang Qianli Zhang 《Railway Sciences》 2023年第2期179-196,共18页
Purpose-It is of great significance to study the influence of subgrade filling on permafrost temperature field in permafrost area for the smooth construction and safe operation of railway.Design/methodology/approach-T... Purpose-It is of great significance to study the influence of subgrade filling on permafrost temperature field in permafrost area for the smooth construction and safe operation of railway.Design/methodology/approach-The paper builds up the model for the hydrothermal coupling calculation of permafrost using finite element software COMSOL to study how permafrost temperature field changes in the short term after subgrade filling,on which basis it proposes the method of calculation for the concave distortion of freezing front in the subgrade-covered area.Findings-The results show that the freezing front below the subgrade center sinks due to the thermal effect of subgrade filling,which will trigger hydrothermal erosion in case of sufficient moisture inflows,leading to the thawing settlement or the cracking of the subgrade,etc.The heat output of soil will be hindered the most in case of July filling,in which case the sinking and the distortion of the freezing front is found to be the most severe,which the recovery of the permafrost temperature field,the slowest,constituting the most unfavorable working condition.The concave distortion of the freezing front in the subgrade area increases with the increase in temperature difference between the filler and ground surface,the subgrade height,the subgrade width and the volumetric thermal capacity of filler,while decreases with the increase of the thermal conductivity of filler.Therefore,the filler chose for engineering project shall be of small volumetric thermal capacity,low initial temperature and high thermal conductivity whenever possible.Originality/value-The concave distortion of the freezing front under different working conditions at different times after filling can be calculated using the method proposed. 展开更多
关键词 SUBGRADE PERMAFROST temperature field Hydrothermal coupling Numerical simulation
下载PDF
Investigation of the Behavior of a Photovoltaic Cell under Concentration as a Function of the Temperature of the Base and a Variable External Magnetic Field in 3D Approximation
16
作者 Boubacar Soro Adama Ouedraogo +4 位作者 Mahamadi Savadogo Ramatou Konate Guyserge Tchouadep Martial Zoungrana Sié Kam 《Smart Grid and Renewable Energy》 2023年第12期209-220,共12页
The photovoltaic (PV) cell performances are connected to the base photogenerated carriers charge. Some studies showed that the quantity of the photogenerated carriers charge increases with the increase of the solar il... The photovoltaic (PV) cell performances are connected to the base photogenerated carriers charge. Some studies showed that the quantity of the photogenerated carriers charge increases with the increase of the solar illumination. This situation explains the choice of concentration PV cell (C = 50 suns) in this study. However, the strong photogeneration of the carriers charge causes a high heat production by thermalization, collision and carriers charge braking due to the electric field induced by concentration gradient. This heat brings the heating of the PV cell base. That imposes the taking into account of the temperature influence in the concentrator PV cell operation. Moreover, with the proliferation of the magnetic field sources in the life space, it is important to consider its effect on the PV cell performances. Thus, when magnetic field and base temperature increase simultaneously, we observe a deterioration of the photovoltage, the electric power, the space charge region capacity, the fill factor and the conversion efficiency. However the photocurrent increases when the base temperature increases and the magnetic field strength decreases. It appears an inversion phenomenon in the evolution of the electrical parameters as a function of magnetic field for the values of magnetic field B> 4×10<sup>-4 </sup>T. 展开更多
关键词 THERMALIZATION Base temperature Magnetic field Fill Factor Efficiency Space Charge region Capacity
下载PDF
Identifying Regional Prolonged Low Temperature Events in China 被引量:24
17
作者 张宗婕 钱维宏 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2011年第2期338-351,共14页
This study examined regional prolonged low temperature (PLT) events in China from the observational station data for the period 1960–2008 using the new criteria. The new definition of a site PLT event is that the d... This study examined regional prolonged low temperature (PLT) events in China from the observational station data for the period 1960–2008 using the new criteria. The new definition of a site PLT event is that the daily minimum temperature does not exceed the 10th percentile threshold of the local daily minimum temperature climatology for at least 5 days at a station. The regional PLT event is defined as at least five adjacent stations exhibiting site PLT simultaneously for 5 d. Under the new definition, 552 regional PLT events were identified, and three indices: duration, extent, and intensity, as well as a comprehensive index (CI) were used to quantify the event severity. In addition, geographical patterns and temporal variations of regional PLT events were investigated using three event categories: strong, moderate, and weak. Spatially, strong events were mainly located in the north of Xinjiang and along the Yangtze River to the south of the Yangtze River; moderate events occurred in Xinjiang and south of the Yangtze River; and weak events occurred south of the Yellow River. The variation for the annual frequency of regional PLT events in China in the last 49 years showed a significant decreasing trend with a rate of-1.99 times per decade, and the significant transition decade was the 1980s. 展开更多
关键词 regional prolonged low temperature extreme event duration index comprehensive index spatiotemporal variation
下载PDF
Analysis of temperature field characteristics based on subgrade site measurements of Harbin-Qiqihar High-speed Railway in a deep seasonal frozen soil region 被引量:9
18
作者 ZuRun Yue BoWen Tai TieCheng Sun 《Research in Cold and Arid Regions》 CSCD 2015年第5期547-553,共7页
Recent years have seen a large number of high-speed railways built and will be built in seasonal frozen soil regions ot China. Although high-speed railways are characterized by being fast, comfortable and safe, higher... Recent years have seen a large number of high-speed railways built and will be built in seasonal frozen soil regions ot China. Although high-speed railways are characterized by being fast, comfortable and safe, higher standards for defor- mation of the railways' frozen subgrade are required. Meanwhile, changes in subgrade soil temperatures are the main factors affecting the deformation of frozen subgrade. Therefore, this paper selected typical test subgrade sections of the Harbin-Qiqihar Line, a special line for passenger transport built in the deep seasonal frozen soil regions of China, to monitor field temperatures. Also, the temperature changing laws of railways' subgrade in this region was analyzed by using testing data, the aim of which is to provide a technical support for future design and construction of buildings and structures in a deep seasonal frozen soil region. 展开更多
关键词 temperature field deep seasonal permafrost soils railways SUBGRADE
下载PDF
Assessment of the effects of the shelterbelt on the soil temperature at regional scale based on MODIS data 被引量:3
19
作者 DENG Rong-xin LI Ying +2 位作者 ZHANG Shu-wen WANG Wen-juan SHI Xiao-liang 《Journal of Forestry Research》 SCIE CAS CSCD 2011年第1期65-70,共6页
At present, the most researches on the protected effect of shelterbelt are on the basis of the two scales of forest belts and networks. However, with the further research on the global environmental change, more atten... At present, the most researches on the protected effect of shelterbelt are on the basis of the two scales of forest belts and networks. However, with the further research on the global environmental change, more attention was paid to the regional climate effect of shelterbelt. In present study, we analyzed the temperature effect of the shelterbelt at regional scale by using the land surface temperature (LST) data from the moderate resolution imaging spectroradiometer (MODIS) at Yushu, Nong'an, Dehui, and Fuyu in Jilin Province of China from March to October in 2008. Results show that the shelterbelt can increase the soil temperature of the protected farmland as compared with no shelterbelt zone, with the increment of 0.57oC per day in fine shelterbelt and 0.38oC per day in the normal shelterbelt. Moreover, the correlation analysis of the air temperature, precipitation and the soil type and the shelterbelt effect shows that the air temperature and precipitation are negatively correlated with the shelterbelt effects, that is, the more the temperature and precipitation are, the less the effect produced. While the impact of the soil types on the shelterbelt's effect is not very obvious as a whole. This paper draws significance in terms of analyzing the effects of the shelterbelt on the soil temperature at regional scale utilizing the remotely sensed data and GIS technique. 展开更多
关键词 regional scale remote sensing SHELTERBELT temperature effect
下载PDF
Study on the Effects of Land Surface Heterogeneities in Temperature and Moisture on Annual Scale Regional Climate Simulation 被引量:4
20
作者 曾新民 刘金波 +3 位作者 马柱国 宋帅 席朝笠 王汉杰 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2010年第1期151-163,共13页
The "combined approach", which is suitable to represent subgrid land surface heterogeneity in both interpatch and intra-patch variabilities, is employed in the BiOsphere/Atmosphere Transfer Scheme (BATS) as a land... The "combined approach", which is suitable to represent subgrid land surface heterogeneity in both interpatch and intra-patch variabilities, is employed in the BiOsphere/Atmosphere Transfer Scheme (BATS) as a land surface component of the regional climate model RegCM3 to consider the heterogeneities in temperature and moisture at the land surface, and then annual-scale simulations for 5 years (1988-1992) were conducted. Results showed that on the annual scale, the model's response to the heterogeneities is quite sensitive, and that the effect of the temperature heterogeneity (TH) is more pronounced than the moisture heterogeneity (MH). On the intraannual scale, TH may lead to more (less) precipitation in warm (cold) seasons, and hence lead to larger intraannual variability in precipitation; the major MH effects may be lagged by about 1 month during the warm, rainy seasons, inducing -6% more precipitation for some sub-regions. Additionally, the modeled climate for the northern sub-regions shows larger sensitivities to the land surface heterogeneities than those for the southern sub-regions. Since state-of-art land surface models seldom account for surface intra-patch variabilities, this study emphasizes the importance of including this kind of variability in the land surface models. 展开更多
关键词 regional climate model heterogeneities in temperature and moisture simulation on the annual scale sensitivity
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部