AIM: To compare the wavefront aberrations and corneal surface regularity between dry eye(DE) patients and normal subjects and assess its diagnostic performance for DE measured with OPD Scan-Ⅲ.METHODS: Fifty right eye...AIM: To compare the wavefront aberrations and corneal surface regularity between dry eye(DE) patients and normal subjects and assess its diagnostic performance for DE measured with OPD Scan-Ⅲ.METHODS: Fifty right eyes of 50 DE patients and 31 right eyes of normal subjects were included.The examinations for ocular surface including logarithm of the minimum angle of resolution best-corrected distance visual acuity(logMAR BCVA) the ocular surface disease index(OSDI), tear film break-up time(TBUT) and corneal fluorescein staining(CFS).OPD Scan-Ⅲ was used to measure anterior corneal aberrations including total corneal aberrations, high order aberration(HOA), coma, trefoil, spherical aberration(SA), standard deviation of corneal power(SDP), surface regularity index(SRI) and surface asymmetry index(SAI).Statistical analysis were assessed with nonparametric tests and Spearman’s correlations.All parameters were also analyzed for sensitivity, specificity, and receiver operating characteristics(ROC) curves.RESULTS: Wavefront aberrations parameters including total corneal aberrations, HOA, coma, trefoil, and SA in DE group were significantly higher than those in normal group(P<0.001).Corneal surface regularity parameters including SRI and SAI in DE group were significantly higher than both in normal group(P<0.05).All the wavefront aberrations parameters had significant correlations with ocular surface parameters(P<0.05).The logMAR BCVA had positive correlations with SAI and SRI(all P<0.001).CFS scores had positive correlations with SAI and SRI(all P<0.001).All the wavefront aberrations parameters showed good diagnosis sensitivity and specificity, however, the corneal regularity parameters showed only good specificity but poor sensitivity.The cut-off value selected for trefoil in diagnosis DE showed the highest area under the curve(AUC, 0.921) values as compared to the other parameters with sensitivity of 0.955 and specificity of 0.867.CONCLUSION: Wavefront aberrations and corneal surface regularity are increased in DE patients and also correlated with ocular surface parameters.Wavefront aberrations parameters have potential to be indicators to diagnosis and monitor DE.展开更多
A principal direction Gaussian image (PDGI)-based algorithm is proposed to extract the regular swept surface from point cloud. Firstly, the PDGI of the regular swept surface is constructed from point cloud, then the...A principal direction Gaussian image (PDGI)-based algorithm is proposed to extract the regular swept surface from point cloud. Firstly, the PDGI of the regular swept surface is constructed from point cloud, then the bounding box of the Gaussian sphere is uniformly partitioned into a number of small cubes (3D grids) and the PDGI points on the Gaussian sphere are associated with the corresponding 3D grids. Secondly, cluster analysis technique is used to sort out a group of 3D grids containing more PDGI points among the 3D grids. By the connected-region growing algorithm, the congregation point or the great circle is detected from the 3D grids. Thus the translational direction is determined by the congregation point and the direction of the rotational axis is determined by the great circle. In addition, the positional point of the rotational axis is obtained by the intersection of all the projected normal lines of the rotational surface on the plane being perpendicular to the estimated direction of the rotational axis. Finally, a pattem search method is applied to optimize the translational direction and the rotational axis. Some experiments are used to illustrate the feasibility of the above algorithm.展开更多
In this note a simple proof of the famous Fermat-Torricelli problem is given. For the vertices of a given triangle, Fermat asks for a fourth point such that the sum of its Euclidean distances to the three given points...In this note a simple proof of the famous Fermat-Torricelli problem is given. For the vertices of a given triangle, Fermat asks for a fourth point such that the sum of its Euclidean distances to the three given points is minimized. Many authors present geometric approaches to the Fermat-Torricelli problem. We solve the problem by analytic and geometrical method and extend it to the sphere, we also characterize the median point P on the general regular surface.展开更多
Rational Bezier surface is a widely used surface fitting tool in CAD. When all the weights of a rational B@zier surface go to infinity in the form of power function, the limit of surface is the regular control surface...Rational Bezier surface is a widely used surface fitting tool in CAD. When all the weights of a rational B@zier surface go to infinity in the form of power function, the limit of surface is the regular control surface induced by some lifting function, which is called toric degenerations of rational Bezier surfaces. In this paper, we study on the degenerations of the rational Bezier surface with weights in the exponential function and indicate the difference of our result and the work of Garcia-Puente et al. Through the transformation of weights in the form of exponential function and power function, the regular control surface of rational Bezier surface with weights in the exponential function is defined, which is just the limit of the surface. Compared with the power function, the exponential function approaches infinity faster, which leads to surface with the weights in the form of exponential function degenerates faster.展开更多
The foundation of the ultrasonic non-destructive determination of stresses in near-the-surface layers of solids is presented. The method is based on the regularities of Rayleigh wave propagation in solids with initial...The foundation of the ultrasonic non-destructive determination of stresses in near-the-surface layers of solids is presented. The method is based on the regularities of Rayleigh wave propagation in solids with initial (residual) stresses. A description of the above mentioned method and examples of stress determination are presented. Examples are considered as applied to the residual stresses arising at electric welding and the operating stresses arising at loading.展开更多
文摘AIM: To compare the wavefront aberrations and corneal surface regularity between dry eye(DE) patients and normal subjects and assess its diagnostic performance for DE measured with OPD Scan-Ⅲ.METHODS: Fifty right eyes of 50 DE patients and 31 right eyes of normal subjects were included.The examinations for ocular surface including logarithm of the minimum angle of resolution best-corrected distance visual acuity(logMAR BCVA) the ocular surface disease index(OSDI), tear film break-up time(TBUT) and corneal fluorescein staining(CFS).OPD Scan-Ⅲ was used to measure anterior corneal aberrations including total corneal aberrations, high order aberration(HOA), coma, trefoil, spherical aberration(SA), standard deviation of corneal power(SDP), surface regularity index(SRI) and surface asymmetry index(SAI).Statistical analysis were assessed with nonparametric tests and Spearman’s correlations.All parameters were also analyzed for sensitivity, specificity, and receiver operating characteristics(ROC) curves.RESULTS: Wavefront aberrations parameters including total corneal aberrations, HOA, coma, trefoil, and SA in DE group were significantly higher than those in normal group(P<0.001).Corneal surface regularity parameters including SRI and SAI in DE group were significantly higher than both in normal group(P<0.05).All the wavefront aberrations parameters had significant correlations with ocular surface parameters(P<0.05).The logMAR BCVA had positive correlations with SAI and SRI(all P<0.001).CFS scores had positive correlations with SAI and SRI(all P<0.001).All the wavefront aberrations parameters showed good diagnosis sensitivity and specificity, however, the corneal regularity parameters showed only good specificity but poor sensitivity.The cut-off value selected for trefoil in diagnosis DE showed the highest area under the curve(AUC, 0.921) values as compared to the other parameters with sensitivity of 0.955 and specificity of 0.867.CONCLUSION: Wavefront aberrations and corneal surface regularity are increased in DE patients and also correlated with ocular surface parameters.Wavefront aberrations parameters have potential to be indicators to diagnosis and monitor DE.
基金This project is supported by Key Program of National Natural Science Foundation of China(No.50435020).
文摘A principal direction Gaussian image (PDGI)-based algorithm is proposed to extract the regular swept surface from point cloud. Firstly, the PDGI of the regular swept surface is constructed from point cloud, then the bounding box of the Gaussian sphere is uniformly partitioned into a number of small cubes (3D grids) and the PDGI points on the Gaussian sphere are associated with the corresponding 3D grids. Secondly, cluster analysis technique is used to sort out a group of 3D grids containing more PDGI points among the 3D grids. By the connected-region growing algorithm, the congregation point or the great circle is detected from the 3D grids. Thus the translational direction is determined by the congregation point and the direction of the rotational axis is determined by the great circle. In addition, the positional point of the rotational axis is obtained by the intersection of all the projected normal lines of the rotational surface on the plane being perpendicular to the estimated direction of the rotational axis. Finally, a pattem search method is applied to optimize the translational direction and the rotational axis. Some experiments are used to illustrate the feasibility of the above algorithm.
文摘In this note a simple proof of the famous Fermat-Torricelli problem is given. For the vertices of a given triangle, Fermat asks for a fourth point such that the sum of its Euclidean distances to the three given points is minimized. Many authors present geometric approaches to the Fermat-Torricelli problem. We solve the problem by analytic and geometrical method and extend it to the sphere, we also characterize the median point P on the general regular surface.
基金Supported by the National Natural Science Foundation of China(11671068,11271060,11601064,11290143)Fundamental Research of Civil Aircraft(MJ-F-2012-04)the Fundamental Research Funds for the Central Universities(DUT16LK38)
文摘Rational Bezier surface is a widely used surface fitting tool in CAD. When all the weights of a rational B@zier surface go to infinity in the form of power function, the limit of surface is the regular control surface induced by some lifting function, which is called toric degenerations of rational Bezier surfaces. In this paper, we study on the degenerations of the rational Bezier surface with weights in the exponential function and indicate the difference of our result and the work of Garcia-Puente et al. Through the transformation of weights in the form of exponential function and power function, the regular control surface of rational Bezier surface with weights in the exponential function is defined, which is just the limit of the surface. Compared with the power function, the exponential function approaches infinity faster, which leads to surface with the weights in the form of exponential function degenerates faster.
文摘The foundation of the ultrasonic non-destructive determination of stresses in near-the-surface layers of solids is presented. The method is based on the regularities of Rayleigh wave propagation in solids with initial (residual) stresses. A description of the above mentioned method and examples of stress determination are presented. Examples are considered as applied to the residual stresses arising at electric welding and the operating stresses arising at loading.