A series of dynamic model tests that were performed on a geogrid-reinforced square footing are presented.The dynamic(sinusoidal)loading was applied using a mechanical testing and simulation(MTS)electro-hydraulic servo...A series of dynamic model tests that were performed on a geogrid-reinforced square footing are presented.The dynamic(sinusoidal)loading was applied using a mechanical testing and simulation(MTS)electro-hydraulic servo loading system.In all the tests,the amplitude of loading was±160 kPa;the frequency of loading was 2 Hz.To better ascertain the effect of reinforcement,an unreinforced square footing was first tested.This was followed by a series of tests,each with a single layer of reinforcement.The reinforcement was placed at depths of 0.3B,0.6B and 0.9B,where B is the width of footing.The optimal depth of reinforcement was found to be 0.6B.The effect of adopting this value versus the other two depths was quantified.The single layer of geogrid had an effective reinforcement depth of 1.7B below the footing base.The increase of the depth between the topmost geogrid layer and the bottom of the footing(within the range of 0.9B)did not change the failure mode of the foundation.展开更多
基金Projects(41962017,51469005)supported by the National Natural Science Foundation of ChinaProject(2017GXNSFAA198170)supported by the Natural Science Foundation in Guangxi Province,China+1 种基金Project supported by the Guangxi University of Science and Technology Innovation Team Support Plan,ChinaProject supported by the High Level Innovation Team and Outstanding Scholars Program of Guangxi Institutions of Higher Learning,China。
文摘A series of dynamic model tests that were performed on a geogrid-reinforced square footing are presented.The dynamic(sinusoidal)loading was applied using a mechanical testing and simulation(MTS)electro-hydraulic servo loading system.In all the tests,the amplitude of loading was±160 kPa;the frequency of loading was 2 Hz.To better ascertain the effect of reinforcement,an unreinforced square footing was first tested.This was followed by a series of tests,each with a single layer of reinforcement.The reinforcement was placed at depths of 0.3B,0.6B and 0.9B,where B is the width of footing.The optimal depth of reinforcement was found to be 0.6B.The effect of adopting this value versus the other two depths was quantified.The single layer of geogrid had an effective reinforcement depth of 1.7B below the footing base.The increase of the depth between the topmost geogrid layer and the bottom of the footing(within the range of 0.9B)did not change the failure mode of the foundation.