Although there are many measures of variability for qualitative variables, they are little used in social research, nor are they included in statistical software. The aim of this article is to present six measures of ...Although there are many measures of variability for qualitative variables, they are little used in social research, nor are they included in statistical software. The aim of this article is to present six measures of variation for qualitative variables of simple calculation, as well as to facilitate their use by means of the R software. The measures considered are, on the one hand, Freemans variation ratio, Morals universal variation ratio, Kvalseths standard deviation from the mode, and Wilcoxs variation ratio which are most affected by proximity to a constant random variable, where the measures of variability for qualitative variables reach their minimum value of 0. On the other hand, the Gibbs-Poston index of qualitative variation and Shannons relative entropy are included, which are more affected by the proximity to a uniform distribution, where the measures of variability for qualitative variables reach their maximum value of 1. Point and interval estimation are addressed. Bootstrap by the percentile and bias-corrected and accelerated percentile methods are used to obtain confidence intervals. Two calculation situations are presented: with a sample mode and with two or more modes. The standard deviation from the mode among the six considered measures, and the universal variation ratio among the three variation ratios, are particularly recommended for use.展开更多
Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppress...Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppressing was developed using laser-induced plasma acoustic signals to correct the original spectrum,thereby improving the analysis accuracy of the soil elements.A good linear relationship was investigated firstly between the original spectral intensity and the acoustic signals.The relative standard deviations(RSDs)of Mg,Ca,Sr,and Ba elements were then calculated for both the original spectrum and the spectrum with the acoustic correction,and the RSDs were significantly reduced with the acoustic correction.Finally,calibration curves of MgⅠ285.213 nm,CaⅠ422.673 nm,SrⅠ460.733 nm and BaⅡ455.403 nm were established to assess the analytical performance of the proposed acoustic correction method.The values of the determination coefficient(R~2)of the calibration curves for Mg,Ca,Sr,and Ba elements,corrected by the acoustic amplitude,are improved from 0.9845,0.9588,0.6165,and 0.6490 to 0.9876,0.9677,0.8768,and 0.8209,respectively.The values of R~2 of the calibration curves corrected by the acoustic energy are further improved to 0.9917,0.9827,0.8835,and 0.8694,respectively.These results suggest that the matrix effect of LIBS on soils can be clearly improved by using acoustic correction,and acoustic energy correction works more efficiently than acoustic amplitude correction.This work provides a simple and efficient method for correcting matrix effects in the element analysis of soils by acoustic signals.展开更多
Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quant...Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quantitative analysis. It was found that there was great potential to improve the signal quality and repeatability by reducing the laser beam divergence angle using a suitable beam expander (BE). In the present work, the influences of several experimental parameters for the case with BE are studied in order to optimize the analytical performances: the signal to noise ratio (SNR) and the relative standard deviation (RSD). We demonstrate that by selecting the optimal experimental parameters, the BE-included LIBS setup can give higher SNR and lower RSD values of the line intensity normalized by the whole spectrum area. For validation purposes, support vector machine (SVM) regression combined with principal component analysis (PCA) was used to establish a calibration model to realize the quantitative analysis of the ash content. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The measurement accuracy presented here for ash content analysis is estimated to be 0.31%, while the average relative error is 2.36%.展开更多
It was found earlier that moisture content (MC) of intact kernels of grain and nuts could be determined by Near Infra Red (NIR) reflectance spectrometry. However, if the MC values can be determined while the nuts are ...It was found earlier that moisture content (MC) of intact kernels of grain and nuts could be determined by Near Infra Red (NIR) reflectance spectrometry. However, if the MC values can be determined while the nuts are in their shells, it would save lot of labor and money spent in shelling and cleaning the nuts. Grain and nuts absorb low levels of NIR, and when NIR radiation is incident on them, a substantial portion of the radiation is reflected back. Thus, studying the NIR reflectance spectra emanating from in-shell peanuts, an attempt is made for the first time to determine the MC of in-shell peanuts. In-shell peanuts of two different market types, Virginia and Valencia, were conditioned to different moisture levels between 6% and 26% (wet basis), and separated into calibration and validation groups. NIR absorption spectral data from 1000 nm to 2500 nm in 1 nm intervals were collected from both groups. Measurements were obtained on 30 replicates within each moisture level. Reference MC values for each moisture level in these groups were obtained using standard air-oven method. Partial Least Square (PLS) analysis was performed on the calibration data, and prediction models were developed. The Standard Error of Calibration (SEC), and R2 of the calibration models were computed to select the best calibration model. The selected models were used to predict the moisture content of peanuts in the validation sets. Predicted MC values of the validation samples were compared with their standard air-oven moisture values. Goodness of fit was determined based on the lowest Standard Error of Prediction (SEP) and highest R2 value obtained for the prediction models. The model, with reflectance plus normalization spectral data with an SEP of 0.74 for Valencia and 1.57 for Virginia type in-shell peanuts was selected as the best model. The corresponding R2 values were 0.98 for both peanut types. This work establishes the possibility of sensing MC of intact in-shell peanuts by NIR reflectance method, and would be useful for the peanut and allied industries.展开更多
文摘Although there are many measures of variability for qualitative variables, they are little used in social research, nor are they included in statistical software. The aim of this article is to present six measures of variation for qualitative variables of simple calculation, as well as to facilitate their use by means of the R software. The measures considered are, on the one hand, Freemans variation ratio, Morals universal variation ratio, Kvalseths standard deviation from the mode, and Wilcoxs variation ratio which are most affected by proximity to a constant random variable, where the measures of variability for qualitative variables reach their minimum value of 0. On the other hand, the Gibbs-Poston index of qualitative variation and Shannons relative entropy are included, which are more affected by the proximity to a uniform distribution, where the measures of variability for qualitative variables reach their maximum value of 1. Point and interval estimation are addressed. Bootstrap by the percentile and bias-corrected and accelerated percentile methods are used to obtain confidence intervals. Two calculation situations are presented: with a sample mode and with two or more modes. The standard deviation from the mode among the six considered measures, and the universal variation ratio among the three variation ratios, are particularly recommended for use.
基金financially supported by National Natural Science Foundation of China(No.12064029)by Jiangxi Provincial Natural Science Foundation(No.20202BABL202024)by the Open project program of Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province(No.ED202208094)。
文摘Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppressing was developed using laser-induced plasma acoustic signals to correct the original spectrum,thereby improving the analysis accuracy of the soil elements.A good linear relationship was investigated firstly between the original spectral intensity and the acoustic signals.The relative standard deviations(RSDs)of Mg,Ca,Sr,and Ba elements were then calculated for both the original spectrum and the spectrum with the acoustic correction,and the RSDs were significantly reduced with the acoustic correction.Finally,calibration curves of MgⅠ285.213 nm,CaⅠ422.673 nm,SrⅠ460.733 nm and BaⅡ455.403 nm were established to assess the analytical performance of the proposed acoustic correction method.The values of the determination coefficient(R~2)of the calibration curves for Mg,Ca,Sr,and Ba elements,corrected by the acoustic amplitude,are improved from 0.9845,0.9588,0.6165,and 0.6490 to 0.9876,0.9677,0.8768,and 0.8209,respectively.The values of R~2 of the calibration curves corrected by the acoustic energy are further improved to 0.9917,0.9827,0.8835,and 0.8694,respectively.These results suggest that the matrix effect of LIBS on soils can be clearly improved by using acoustic correction,and acoustic energy correction works more efficiently than acoustic amplitude correction.This work provides a simple and efficient method for correcting matrix effects in the element analysis of soils by acoustic signals.
基金supported by the 973 Program of China(No.2012CB921603)National Natural Science Foundation of China(Nos.61475093,61127017,61178009,61108030,61378047,61275213,61475093,and 61205216)+3 种基金the National Key Technology R&D Program of China(No.2013BAC14B01)the Shanxi Natural Science Foundation(Nos.2013021004-1 and 2012021022-1)the Shanxi Scholarship Council of China(Nos.2013-011 and 2013-01)the Program for the Outstanding Innovative Teams of Higher Learning Institutions of Shanxi,China
文摘Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quantitative analysis. It was found that there was great potential to improve the signal quality and repeatability by reducing the laser beam divergence angle using a suitable beam expander (BE). In the present work, the influences of several experimental parameters for the case with BE are studied in order to optimize the analytical performances: the signal to noise ratio (SNR) and the relative standard deviation (RSD). We demonstrate that by selecting the optimal experimental parameters, the BE-included LIBS setup can give higher SNR and lower RSD values of the line intensity normalized by the whole spectrum area. For validation purposes, support vector machine (SVM) regression combined with principal component analysis (PCA) was used to establish a calibration model to realize the quantitative analysis of the ash content. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The measurement accuracy presented here for ash content analysis is estimated to be 0.31%, while the average relative error is 2.36%.
文摘It was found earlier that moisture content (MC) of intact kernels of grain and nuts could be determined by Near Infra Red (NIR) reflectance spectrometry. However, if the MC values can be determined while the nuts are in their shells, it would save lot of labor and money spent in shelling and cleaning the nuts. Grain and nuts absorb low levels of NIR, and when NIR radiation is incident on them, a substantial portion of the radiation is reflected back. Thus, studying the NIR reflectance spectra emanating from in-shell peanuts, an attempt is made for the first time to determine the MC of in-shell peanuts. In-shell peanuts of two different market types, Virginia and Valencia, were conditioned to different moisture levels between 6% and 26% (wet basis), and separated into calibration and validation groups. NIR absorption spectral data from 1000 nm to 2500 nm in 1 nm intervals were collected from both groups. Measurements were obtained on 30 replicates within each moisture level. Reference MC values for each moisture level in these groups were obtained using standard air-oven method. Partial Least Square (PLS) analysis was performed on the calibration data, and prediction models were developed. The Standard Error of Calibration (SEC), and R2 of the calibration models were computed to select the best calibration model. The selected models were used to predict the moisture content of peanuts in the validation sets. Predicted MC values of the validation samples were compared with their standard air-oven moisture values. Goodness of fit was determined based on the lowest Standard Error of Prediction (SEP) and highest R2 value obtained for the prediction models. The model, with reflectance plus normalization spectral data with an SEP of 0.74 for Valencia and 1.57 for Virginia type in-shell peanuts was selected as the best model. The corresponding R2 values were 0.98 for both peanut types. This work establishes the possibility of sensing MC of intact in-shell peanuts by NIR reflectance method, and would be useful for the peanut and allied industries.