The industrial power systems are moving to digital networks,and unmanned systems are increasing recently with the technological development of information and communication technology.In particular,reliability of syst...The industrial power systems are moving to digital networks,and unmanned systems are increasing recently with the technological development of information and communication technology.In particular,reliability of system operation is very important for stable power supply.Most industrial power distribution facilities use a 154 kV or 22.9 kV extra HV(high voltage)power system,and a special monitoring system is required because a large loss occurs when an error occurs in the power facility in the field.Although digital protection relay(IED;intelligent electronic device)and FR(fault recorder)are applied to the field to protect the power system,various improvement activities are still ongoing.In this paper,a 22.9 kV high-voltage panel and its test bed,which are widely used in railway stations,tunnels,substations and large plants,were tested as test subjects.The developed fault detection system automatically starts the AL(auto-lock)circuit or outputs an alarm signal to user by monitoring in real time problems such as CT(current transformer)-open and poor-contact that the existing digital protection relay cannot cover.In addition,it is intended to increase the safety and reliability of the power system by blocking various accidents in the system in advance and accurately analyzing the causes of faults with the developed fault detection system.展开更多
With the development of large-scale complicated modern power systems, the requirement for the associated protection scheme tends to be more stringent and its combination more complex. However, it is very difficult to ...With the development of large-scale complicated modern power systems, the requirement for the associated protection scheme tends to be more stringent and its combination more complex. However, it is very difficult to figure out the factors of failure of such systems. This paper proposes a Petri net model of a transmission line protection relaying system, including three types of relays as well as an automatic reclosing device, and shows how to diagnose serial failure of the system by analyzing invariant sets of the model. Furthermore, it gives four basic types of failure sequences and its execution is much more intuitive and effective than the traditional method.展开更多
A vital attribute of electrical power network is the continuity of service with a high level of reliability. This motivated many researchers to investigate power systems in an effort to improve reliability by focusing...A vital attribute of electrical power network is the continuity of service with a high level of reliability. This motivated many researchers to investigate power systems in an effort to improve reliability by focusing on fault detection, classification and localization. In this paper, a new protective relaying framework to detect, classify and localize faults in an electrical power transmission system is presented. This work will extract phase current values during ( )th of a cycle to generate unique signatures. By utilizing principal component analysis (PCA) methods, this system will identify and classify any fault instantaneously. Also, by using the curve fitting polynomial technique with our index pattern obtained from the unique fault signature, the location of the fault can be determined with a significant accuracy.展开更多
Recently, power distribution system is getting larger and more complex. It is very difficult even for the experts to diagnosis and monitoring to made best action. This motivated many researchers to investigate power s...Recently, power distribution system is getting larger and more complex. It is very difficult even for the experts to diagnosis and monitoring to made best action. This motivated many researchers to investigate power systems in an effort to improve reliability by focusing on fault detection and classification. There have been many studies on problems but the results are not good enough for applying to real power system. In this paper, a new protective relaying framework to diagnosis and monitoring faults in an electrical power distribution system with. This work will extract fault signatures by using ellipse fit using least squares criterion during fault condition. By utilizing principal component analysis methods, this system will identify, classify and localize any fault instantaneously.展开更多
In order to provide a novel and more effective alternative to the commonly used relay protection testing device that outputs only the sinusoidal testing signals, the concept of fault waveform regenerator is proposed i...In order to provide a novel and more effective alternative to the commonly used relay protection testing device that outputs only the sinusoidal testing signals, the concept of fault waveform regenerator is proposed in this paper, together with its hardware structure and software flow chart. Fault waveform regenerator mainly depends on its power amplifiers (PAs) to regenerate the fault waveforms recorded by digital fault recorder (DFR). To counteract the PA’s inherent nonlinear distortions, a digital closed-loop modification technique that is different from the predistortion technique is conceived. And the experimental results verify the effectiveness of the fault waveform regenerator based on the digital closed-loop modification technique.展开更多
There were many accidents of large-scale wind turbines disconnecting from power grid in 2011.As singlephase-to-ground fault cannot be correctly detected,single-phase-to-ground fault evolved to phase-to-phase fault.Pha...There were many accidents of large-scale wind turbines disconnecting from power grid in 2011.As singlephase-to-ground fault cannot be correctly detected,single-phase-to-ground fault evolved to phase-to-phase fault.Phase-to-phase fault was isolated slowly,thus leading to low voltage.And wind turbines without enough low voltage ride-through capacity had to be disconnected from the grid.After some wind turbines being disconnected from the grid,overvoltage caused by reactive power surplus made more wind turbines disconnect from the grid.Based on the accident analysis,this paper presents solutions to above problems,including travelling waves based single-phase-to-ground protection,adaptive low voltage protection,integrated protection and control,and high impedance fault detection.The solutions lay foundations in theory and technology to prevent large-scale wind turbines disconnecting from the operating power grid.展开更多
A new principle for grounding fault feeder detection based on negative sequence current variation and energy dissipated in the fault point is presented. It has high precision in both isolated systems and resonance ear...A new principle for grounding fault feeder detection based on negative sequence current variation and energy dissipated in the fault point is presented. It has high precision in both isolated systems and resonance earthed systems, even in full compensated systems. And it can be installed at the local control unit of feeder in distribution automation systems, such as field terminal unit (FTU). This principle is verified by EMTP simulator and experimentation.展开更多
基金This study was conducted by the Ministry of Land,Infrastructure and Transport’s Research Project on Railway Technology-Projects(21RTRP-B146037-04).
文摘The industrial power systems are moving to digital networks,and unmanned systems are increasing recently with the technological development of information and communication technology.In particular,reliability of system operation is very important for stable power supply.Most industrial power distribution facilities use a 154 kV or 22.9 kV extra HV(high voltage)power system,and a special monitoring system is required because a large loss occurs when an error occurs in the power facility in the field.Although digital protection relay(IED;intelligent electronic device)and FR(fault recorder)are applied to the field to protect the power system,various improvement activities are still ongoing.In this paper,a 22.9 kV high-voltage panel and its test bed,which are widely used in railway stations,tunnels,substations and large plants,were tested as test subjects.The developed fault detection system automatically starts the AL(auto-lock)circuit or outputs an alarm signal to user by monitoring in real time problems such as CT(current transformer)-open and poor-contact that the existing digital protection relay cannot cover.In addition,it is intended to increase the safety and reliability of the power system by blocking various accidents in the system in advance and accurately analyzing the causes of faults with the developed fault detection system.
文摘With the development of large-scale complicated modern power systems, the requirement for the associated protection scheme tends to be more stringent and its combination more complex. However, it is very difficult to figure out the factors of failure of such systems. This paper proposes a Petri net model of a transmission line protection relaying system, including three types of relays as well as an automatic reclosing device, and shows how to diagnose serial failure of the system by analyzing invariant sets of the model. Furthermore, it gives four basic types of failure sequences and its execution is much more intuitive and effective than the traditional method.
文摘A vital attribute of electrical power network is the continuity of service with a high level of reliability. This motivated many researchers to investigate power systems in an effort to improve reliability by focusing on fault detection, classification and localization. In this paper, a new protective relaying framework to detect, classify and localize faults in an electrical power transmission system is presented. This work will extract phase current values during ( )th of a cycle to generate unique signatures. By utilizing principal component analysis (PCA) methods, this system will identify and classify any fault instantaneously. Also, by using the curve fitting polynomial technique with our index pattern obtained from the unique fault signature, the location of the fault can be determined with a significant accuracy.
文摘Recently, power distribution system is getting larger and more complex. It is very difficult even for the experts to diagnosis and monitoring to made best action. This motivated many researchers to investigate power systems in an effort to improve reliability by focusing on fault detection and classification. There have been many studies on problems but the results are not good enough for applying to real power system. In this paper, a new protective relaying framework to diagnosis and monitoring faults in an electrical power distribution system with. This work will extract fault signatures by using ellipse fit using least squares criterion during fault condition. By utilizing principal component analysis methods, this system will identify, classify and localize any fault instantaneously.
文摘In order to provide a novel and more effective alternative to the commonly used relay protection testing device that outputs only the sinusoidal testing signals, the concept of fault waveform regenerator is proposed in this paper, together with its hardware structure and software flow chart. Fault waveform regenerator mainly depends on its power amplifiers (PAs) to regenerate the fault waveforms recorded by digital fault recorder (DFR). To counteract the PA’s inherent nonlinear distortions, a digital closed-loop modification technique that is different from the predistortion technique is conceived. And the experimental results verify the effectiveness of the fault waveform regenerator based on the digital closed-loop modification technique.
基金supported by Major International Collaborative Project of National Natural Science Foundation of China(No.51120175001)Key Project of National Natural Science Foundation of China(No.50937003)
文摘There were many accidents of large-scale wind turbines disconnecting from power grid in 2011.As singlephase-to-ground fault cannot be correctly detected,single-phase-to-ground fault evolved to phase-to-phase fault.Phase-to-phase fault was isolated slowly,thus leading to low voltage.And wind turbines without enough low voltage ride-through capacity had to be disconnected from the grid.After some wind turbines being disconnected from the grid,overvoltage caused by reactive power surplus made more wind turbines disconnect from the grid.Based on the accident analysis,this paper presents solutions to above problems,including travelling waves based single-phase-to-ground protection,adaptive low voltage protection,integrated protection and control,and high impedance fault detection.The solutions lay foundations in theory and technology to prevent large-scale wind turbines disconnecting from the operating power grid.
文摘A new principle for grounding fault feeder detection based on negative sequence current variation and energy dissipated in the fault point is presented. It has high precision in both isolated systems and resonance earthed systems, even in full compensated systems. And it can be installed at the local control unit of feeder in distribution automation systems, such as field terminal unit (FTU). This principle is verified by EMTP simulator and experimentation.