期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
REMOTE SENSING APPLICATION RESEARCH OF WATER POWER AT THE INITIAL EXPLOITING STAGE IN THE LOWER REACHES OF YALONG RIVER
1
作者 Lin Hengzhang, Xu Gengqin (Institute of Remote Sensing Appilcations, Academia Sinica) He Jianbang (National Lab of Resources and Environment Information System) 《遥感信息》 CSCD 1990年第A02期21-22,共2页
There are abundant water power resources in the Yalong River which are suitable for the large hydroelectric engineering. But a reliability study should be made for the valley which liable to frequent earthquakes. The ... There are abundant water power resources in the Yalong River which are suitable for the large hydroelectric engineering. But a reliability study should be made for the valley which liable to frequent earthquakes. The color infrared aerophotos, multi-spectral photography and thermal infrared scanning had been specially done besides MSS image, processing. Researches on remote sensing applications to engineering geology, hydrogeology, deformation of neo-tectonics, Iandslide, mud-rock flow, ecological environment and geographical information system had been carried out by more than 20 research units. 展开更多
关键词 remote SENSING APPLICATIon RESEARCH OF WATER power AT THE INITIAL EXPLOITING STAGE IN THE LOWER REACHES OF YALonG RIVER AT
下载PDF
Low pump power co-fiber remotely pumped EDFA used in DWDM systems with ultra-long fiber span 被引量:1
2
作者 张帆 张巍 +1 位作者 王燕 彭江得 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第10期570-572,共3页
In this paper, aiming at practical dense wavelength division multiplexing (DWDM) system with ultralong fiber span, a simple co-fiber remotely pumped erbium-doped fiber amplifier (RP-EDFA) scheme is proposed to ext... In this paper, aiming at practical dense wavelength division multiplexing (DWDM) system with ultralong fiber span, a simple co-fiber remotely pumped erbium-doped fiber amplifier (RP-EDFA) scheme is proposed to extend span distance with simple configuration and low pump power. Equivalent noise figure of -6 dB is achieved under 300-mW pump power. Using the experiment results, numerical simulation of ultra-long span systems shows that for a 40 × 11.6-Gb/s transmission system, the RP-EDFA scheme can support transmission of 1760 km with a fiber span of 160 km. These results demonstrate the potential of the PR-EDFA scheme in ultra-long span transmission. 展开更多
关键词 EDFA DWDM Low pump power co-fiber remotely pumped EDFA used in DWDM systems with ultra-long fiber span
原文传递
A powerful approach to alkoxy radical-mediated remote C(sp^3)–H bonds functionalization 被引量:1
3
作者 Cong Xiao Wen-Jing Xiao 《Science China Chemistry》 SCIE EI CAS CSCD 2018年第5期505-506,共2页
The activation of inert C(sp^3)–H bonds with control of reactivity and selectivity is one of the central topics in chemical sciences.
关键词 A powerful approach to alkoxy radical-mediated remote C H bonds functionalization
原文传递
The novel transmission scheme with CAT Ethernet cable and SFP for White Rabbit
4
作者 Yanke Cai Jie Zhang +5 位作者 Yunhua Sun Fengfan Yang Xiaoshan Jiang Changge Zi Cong He Shanshan Cui 《Radiation Detection Technology and Methods》 CSCD 2021年第2期290-296,共7页
Background White Rabbit(WR)is a deterministic Ethernet-based network for general-purpose data transfer and subnanosecond time synchronization in large distributed systems.WR has been used in Large Hadron Collider and ... Background White Rabbit(WR)is a deterministic Ethernet-based network for general-purpose data transfer and subnanosecond time synchronization in large distributed systems.WR has been used in Large Hadron Collider and Large High-Altitude Air Shower Observatory for physics experiment.Purpose WR mainly uses the optical fiber for data transmission between WR devices.Commercial off-the-shelf Direct Attach Cable is not suitable for WR network at 100m level distance.Considering the lower cost of Category(CAT)Ethernet cable compared to optical fiber and the demand of remote power supply in distributed system at 100m level length,we developed a novel transmission scheme with CAT Ethernet cable for WR.Methods The novel transmission scheme uses the CAT Ethernet cable and small form-factor pluggable connector which is compatible with the optical links.This scheme only uses two pairs of twisted lines in the CAT Ethernet cable for data uplink and downlink.The other two pairs of twisted lines are used for remote power supply.Results and conclusion The novel transmission scheme could use the CAT Ethernet cable to complete remote power supply and time synchronization with expected time offset of less than 100 ps and standard deviation of less than 20 ps in the WR distributed system.The distance of distributed nodes could be 80m with one CAT 7 Ethernet cable or 150m with relay transceiver connecting two CAT 7 Ethernet cables.In the short-distance scenarios,the novel transmission scheme has lower cost than the optical fiber and additional power supply function. 展开更多
关键词 White Rabbit Time synchronization SFP CAT Ethernet cable remote power supply
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部