Objective To analyze the possible cause leading to death during the procecture oy IUD removal under hysteroscopy and how it could be prevented. Methods All (11 110) cases of IUD removal under hysteroscopy performed ...Objective To analyze the possible cause leading to death during the procecture oy IUD removal under hysteroscopy and how it could be prevented. Methods All (11 110) cases of IUD removal under hysteroscopy performed at 87 hospitals in Shanghai from 2001 to 2007 were reviewed. Four dead cases were reported. Results Air embolism was suspected as the cause of death. Associated risk factors included insufficient preoperative preparation, short duration between surgeries, non-standard procedure, careless observation and untimely resuscitation. Conclusion This emphasizes the necessity of early interventions taken such as prevention, early detection and management of the fatal complications.展开更多
Intramedullary interlocking nailing is a gold standard for treatment of tibial shaft fractures. Bending of a nail secondary to trauma is a rare complication, which may be encountered in healed or unhealed tibial shaft...Intramedullary interlocking nailing is a gold standard for treatment of tibial shaft fractures. Bending of a nail secondary to trauma is a rare complication, which may be encountered in healed or unhealed tibial shaft fractures. Removal of such bent nail is always a challenge. We reported this case to discuss various techniques for removal of bent nails and to share our experience in removing a bent tibial intramedullary nail in a 30-year-old man, who was admitted in our department with re-fracture of the right tibial shaft due to a roadside accident two years after the initial surgical treatment. The intramedullary nail, bent by 30 degrees and visible on anterioposterior as well as on lateral radiographs, was firstly weakened by partially cutting the convex wall, then straightened by applying external force, and finally removed by using the standard nail removal method.展开更多
文摘Objective To analyze the possible cause leading to death during the procecture oy IUD removal under hysteroscopy and how it could be prevented. Methods All (11 110) cases of IUD removal under hysteroscopy performed at 87 hospitals in Shanghai from 2001 to 2007 were reviewed. Four dead cases were reported. Results Air embolism was suspected as the cause of death. Associated risk factors included insufficient preoperative preparation, short duration between surgeries, non-standard procedure, careless observation and untimely resuscitation. Conclusion This emphasizes the necessity of early interventions taken such as prevention, early detection and management of the fatal complications.
文摘Intramedullary interlocking nailing is a gold standard for treatment of tibial shaft fractures. Bending of a nail secondary to trauma is a rare complication, which may be encountered in healed or unhealed tibial shaft fractures. Removal of such bent nail is always a challenge. We reported this case to discuss various techniques for removal of bent nails and to share our experience in removing a bent tibial intramedullary nail in a 30-year-old man, who was admitted in our department with re-fracture of the right tibial shaft due to a roadside accident two years after the initial surgical treatment. The intramedullary nail, bent by 30 degrees and visible on anterioposterior as well as on lateral radiographs, was firstly weakened by partially cutting the convex wall, then straightened by applying external force, and finally removed by using the standard nail removal method.