期刊文献+
共找到40篇文章
< 1 2 >
每页显示 20 50 100
The hard X-ray nanoprobe beamline at the SSRF
1
作者 Yan He Hui Jiang +6 位作者 Dong-Xu Liang Zhi-Sen Jiang Huai-Na Yu Hua Wang Cheng-Wen Mao Jia-Nan Xie Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期79-88,共10页
The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 t... The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications. 展开更多
关键词 Shanghai synchrotron radiation facility hard x-ray nanoprobe x-ray nanofocusing
下载PDF
Hard X-Ray Modulation Telescope(HXMT) Mission 被引量:4
2
作者 LI Tipei ZHANG Shuangnan LU Fangjun 《空间科学学报》 CAS CSCD 北大核心 2006年第z1期30-41,共12页
The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation devel... The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation developed in recent years, HXMT is mainly devoted to performing a hard X-ray all-sky imaging survey with both high sensitivity and high spatial resolution. It can also be used to make pointed observations of X-ray sources to study their spectroscopic and temporal properties in details. The main detector of HXMT consists of 18 individual cylindrical NaI(T1)/CsI(Na) phoswich modules, each with anarea of 283.5 cm2 and a field of view of 5.7°× 1.1° (FWHM). Its spatial resolution and position accuracy are 5′ and 1′ by using the direct demodulation in 1994, and in 2000 its feasibility and technical demonstration study was selected as a project under the Major State Basic Research Program of China. In October 2005, this project entered the full design phase and was listed as a candidate for the first dedicated astronomy satellite around 2010. We are now also considering secondary low energy instruments for this satellite. 展开更多
关键词 Space Astronomy hard x-ray Satellite
下载PDF
Status of the Hard X-ray Modulation Telescope Project 被引量:2
3
作者 LU Fangjun 《空间科学学报》 CAS CSCD 北大核心 2014年第5期544-546,共3页
The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-... The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-wavelength temporal properties. The pre-flight models of the satellites have been finished, and the flight models are in production. The expected launch date of HXMT is in late 2015. 展开更多
关键词 hard x-ray MODULATION Telescope(HXMT) Astronomical satellite Active GALACTIC NUCLEI
下载PDF
Spectrometer of hard X-ray imager payload onboard the ASO-S mission 被引量:1
4
作者 Yan Zhang Jian-Hua Guo +5 位作者 Zhe Zhang Deng-Yi Chen Yi-Ming Hu Yong-Qiang Zhang Tao Ma Yong-Yi Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第8期92-99,共8页
A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onbo... A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onboard the advanced space-based solar observatory(ASO-S), which is scheduled to be launched in early 2022 as the first Chinese solar satellite. LaBr3 scintillators and photomultiplier tubes with a super bialkali cathode are used to achieve an energy resolution better than 20% at 30 keV.Further, a new multi-channel charge-sensitive readout application-specific integrated circuit guarantees high-frequency data acquisition with low power consumption. This paper presents a detailed design of the spectrometer for the engineering model of the HXI and discusses its noise and linearity performance. 展开更多
关键词 Solar radiation detection x-ray SPECTROMETER hard x-ray IMAGER ASO-S
下载PDF
High-resolution pixelated CdZnTe detector prototype system for solar hard X-ray imager 被引量:1
5
作者 Shen Wang Jian-Hua Guo +1 位作者 Yan Zhang Wei Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期53-58,共6页
A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for fut... A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper. 展开更多
关键词 CDZNTE READOUT system SOLAR observation hard x-ray IMAGER
下载PDF
Hard X-ray focusing resolution and efficiency test with a thickness correction multilayer Laue lens 被引量:1
6
作者 Shuai-Peng Yue Liang Zhou +7 位作者 Yi-Ming Yang Hong Shi Bin Ji Ming Li Peng Liu Ru-Yu Yan Jing-Tao Zhu Guang-Cai Chang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第9期101-110,共10页
The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-n... The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-nm-thick outermost layer and a total thickness of 17 μm, is prepared by DC magnetron sputtering. Regarding the thin film growth rate calibration, we correct the long-term growth rate drift from 2 to 0.6%, as measured by the grazing incidence X-ray reflectivity(GIXRR). A one-dimensional line focusing resolution of 64 nm was achieved,while the diffraction efficiency was 38% of the-1 order of the MLL Shanghai Synchrotron Radiation Facility(SSRF) with the BL15U beamline. 展开更多
关键词 Synchrotron radiation Multilayer Laue lens DC magnetron sputtering Grazing incidence x-ray reflectivity hard x-ray nanofocusing
下载PDF
Hard X-Ray PHA System on the HT-7 Tokamak 被引量:1
7
作者 林士耀 石跃江 +2 位作者 万宝年 陈忠勇 胡立群 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第3期261-264,共4页
A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA).... A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes. 展开更多
关键词 PHA TOKAMAK hard x-ray MCA lower hybrid current driven (LHCD)
下载PDF
Improving Plasma Confinement by Controlling Hard X-Ray
8
作者 N.Hasanvand M.R.Riazifar +2 位作者 R.Alipour S.Meshkani M.Ghoranneviss 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第11期67-70,共4页
Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investi... Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at lOms after the plasma initiation (while the plasma is forming), at 15ms (while the plasma is stable) and at 20ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of O-200 keV when the external electric fields are applied. Also in the duration of 20-30ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stab/e). 展开更多
关键词 of IS that AS on in Improving Plasma Confinement by Controlling hard x-ray by
下载PDF
Photon Temperatures of Hard X-Ray Emission of LHCD Plasmas in HT-7 Tokamak
9
作者 Jawad YOUNIS 万宝年 +4 位作者 陈忠勇 林士耀 石跃江 单家方 刘甫坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第5期529-534,共6页
A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases wi... A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases with the increase in plasma density. In lower hybrid power and phase scanning experiments; there is no appreciable change in the photon temperature. The numerical results based on ray-tracing calculation and Fokker-Planck solver gives reasonable explanation for the experimental observation. Both experimental and numerical results reveal that the photon temperature depends mainly on global effects of the fast electron population, synergy between the fast electron and the loop voltage and the Coulomb slowing down. 展开更多
关键词 LHCD photon temperature hard x-rays
下载PDF
Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
10
作者 姜庆军 冯赟 +5 位作者 肖湘生 刘士远 陈敏 肖体乔 田玉莲 朱佩平 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期34-37,共4页
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in... Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents. 展开更多
关键词 hard x-ray in-line outline imaging x-ray phase-contrast imaging blood vessels imaging synchrotron radiation
下载PDF
Detailed calibration of the PI-LCX:1300 high performance single photon counting hard x-ray CCD camera
11
作者 Wei Hong Xian-Lun Wen +9 位作者 Lai Wei Bin Zhu Yu-Chi Wu Ke-Gong Dong Chun-Ye Jiao Bo Wu Ying-Ling He Fa-Qiang Zhang Wei-Min Zhou Yu-Qiu Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期334-340,共7页
X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon countin... X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon counting CCD cameras with the same mode(model: PI-LCX: 1300) are calibrated with quasi-monochromatic x-rays from radioactive sources and a conventional x-ray tube. The details of the CCD response to x-rays are analyzed by using a computer program of multi-pixel analyzing and event-distinguishing capability. The detection efficiency, energy resolution, fraction of multi-pixel events each as a function of x-ray energy, and consistence of two CCD cameras are obtained. The calibrated detection efficiency is consistent with the detection efficiency from Monte Carlo calculations with XOP program. When the multi-pixel event analysis is applied, the CCDs may be used to measure x-rays up to 60 ke V with good energy resolution(E /?E ≈ 100 at60 ke V). The difference in detection efficiency between two CCD cameras is small(5.6% at 5.89 ke V), but the difference in fraction of the single pixel event between them is much larger(25% at 8.04 ke V). The obtained small relative error of detection efficiency(2.4% at 5.89 ke V) makes the high accurate measurement of x-ray yield possible in the laser plasma interaction studies. Based on the discrete calibration results, the calculated detection efficiency with XOP can be used for the whole range of 5 ke V–30 ke V. 展开更多
关键词 hard x-ray detector single photon counting CCD calibration laser plasmas
下载PDF
Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device 被引量:1
12
作者 Farzin M.Aghamir Reza A.Behbahani 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期375-380,共6页
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista... The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr). 展开更多
关键词 Mather-type plasma focus device hard x-rays multi-radiation tube multiple voltage peaks anomalous resistances
下载PDF
Geant4 simulation of fast-electron bremsstrahlung imaging at the HL-3 tokamak
13
作者 Shi-Kui Cheng Yi-Po Zhang +4 位作者 Yue-Jiang Shi Jie Zhang Shuai Guan Hong-Bing Xu Qiu-Lei Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期213-229,共17页
To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-... To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-structured detector ensures that this system can measure HXR-radiation spectra from the entire plasma cross section.Therefore,it is suitable for the study of fast-electron physics,such as radio-frequency wave current drives,fast electrons driving instabilities,and plasma disruptions in fusion research.In this study,we develop a simulation for calculating fast-electron bremsstrahlung in the HL-3 tokamak based on the Monte Carlo simulation code Geant4,in which the plasma geometry and forward scattering of fast-electron bremsstrahlung are considered.The preliminary calculation results indicate that the HXR energy deposi-tion on the detector is symmetrically distributed,even though the plasma distribution is asymmetric owing to the toroidal effect.These simulation results are helpful in constructing the relationship between the energy deposition on the detector and parameter distribution on the plasma cross section during HL-3 experiments.This is beneficial for the reconstruction of the fast-electron-distribution function and for optimizing the design of the HXR-imaging system. 展开更多
关键词 GEANT4 SIMULATION HL-3 TOKAMAK Fast-electron bremsstrahlung hard x-ray imaging
下载PDF
Strength prediction of multi-layered copper-based composites fabricated by accumulative roll bonding 被引量:6
14
作者 P.SEIFOLLAHZADEH Morteza ALIZADEH M.R.ABBASI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2021年第6期1729-1739,共11页
This work aims to evaluate the feasibility of the fabrication of nanostructured Cu/Al/Ag multi-layered composites by accumulative roll bonding(ARB),and to analyze the tensile properties and electrical conductivity of ... This work aims to evaluate the feasibility of the fabrication of nanostructured Cu/Al/Ag multi-layered composites by accumulative roll bonding(ARB),and to analyze the tensile properties and electrical conductivity of the produced composites.A theoretical model using strengthening mechanisms and some structural parameters extracted from X-ray diffraction is also developed to predict the tensile strength of the composites.It was found that by progression of ARB,the experimental and calculated tensile strengths are enhanced,reach a maximum of about 450 and 510 MPa at the fifth cycle of ARB,respectively and then are reduced.The electrical conductivity decreased slightly by increasing the number of ARB cycles at initial ARB cycles,but the decrease was intensified at the final ARB cycles.In conclusion,the merit of ARB to fabricate this type of multi-layered nanocomposites and the accuracy of the developed model to predict tensile strength were realized. 展开更多
关键词 multi-layered composites accumulative roll bonding strength prediction hardNESS x-ray diffraction
下载PDF
Effect of heat treatment on structure and magnetic properties of Fe65.5Cr4Mo4Ga4P12C5B5.5 bulk amorphous alloy 被引量:4
15
作者 Bratislav Cukic Nebojsa Mitrovic Aleksa Maricic 《China Foundry》 SCIE 2017年第1期59-63,共5页
Abstract: This study deals with the Fe65.5Cr4Mo4Ga4P12C5B5.5 ferromagnetic bulk amorphous alloy. XRD analysis showed an amorphous structure of the as-cast sample. The same method revealed that, after annealing at 973... Abstract: This study deals with the Fe65.5Cr4Mo4Ga4P12C5B5.5 ferromagnetic bulk amorphous alloy. XRD analysis showed an amorphous structure of the as-cast sample. The same method revealed that, after annealing at 973 K for v=10 min, the sample displayed a crystalline structure with crystalline phases formed. The crystallization process of the alloy was examined by DTA analysis. It was shown that crystallization took place in the temperature range between 810 K and 860 K with the exo-maximum peak temperature at 846 K with a heating rate of 20 K.min-1. The method also showed that, at temperatures ranging from 753 K to 810 K, the alloy exhibited the properties of supercooled liquids. A correlation between heat-induced structural changes and magnetic properties of the alloy was determined by thermomagnetic measurements. Maximum magnetization M=3.7 Am2.kg-1 of the alloy was reached after its annealing at 733 K for τ=10 min. Upon annealing, the alloy exhibited a relaxed amorphous structure. Annealing the alloy above the crystallization temperature led to a decrease in bulk magnetization. After annealing at 973 K for r=10 min, the bulk magnetization of the alloy was M'=0.45 Am2.kg-1. Accordingly, after crystallization and formation of new compounds, the magnetization of the alloy was decreased by a factor of about 7.7. The strength of the magnetic field applied during the measurements was H=10 kA.m-1. The samples were tested for changes in the microstructure and hardness of both the amorphous phase and the resulting crystalline phase. 展开更多
关键词 bulk metallic glass x-ray diffraction analysis differential thermal analysis thermomagneticproperties MAGNETIZATION hardNESS microstructure
下载PDF
Simulation study of phase retrieval for hard X-ray in-line phase contrast imaging 被引量:2
16
作者 YU Bin1,2, PENG Xiang1,2, TIAN Jindong1, NIU Hanben1, DIAO Luhong3 & LI Hua3 1. Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education, Institute of Optoelec- tronics, Shenzhen University, Shenzhen 518060, China 2. State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072,China 3. Key Laboratory of Intelligent Information Processing, Institute of Computing Technology, Chinese Academy of Sciences, Beijing 100080,China 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2005年第4期450-458,共9页
Two algorithms for the phase retrieval of hard X-ray in-line phase contrast imaging are presented. One is referred to as Iterative Angular Spectrum Algorithm (IASA) and the other is a hybrid algorithm that combines IA... Two algorithms for the phase retrieval of hard X-ray in-line phase contrast imaging are presented. One is referred to as Iterative Angular Spectrum Algorithm (IASA) and the other is a hybrid algorithm that combines IASA with TIE (transport of intensity equation). The calculations of the algorithms are based on free space propagation of the angular spectrum. The new approaches are demonstrated with numerical simulations. Comparisons with other phase retrieval algorithms are also performed. It is shown that the phase retrieval method combining the IASA and TIE is a promising technique for the application of hard X-ray phase contrast imaging. 展开更多
关键词 x-ray optics PHASE CONTRAST imaging PHASE retrieval ANGULAR spectrum hard x-ray.
原文传递
Two-beam based two-stage EEHG-FEL for coherent hard X-ray generation 被引量:3
17
作者 赵振堂 冯超 +1 位作者 陈建辉 王震 《Science Bulletin》 SCIE EI CAS CSCD 2016年第9期720-727,共8页
The ability to generate stable and coherent short wavelength radiation is a great promise of the externally seeded free-electron laser. However, the fre- quency up-conversion efficiency is limited to a small number in... The ability to generate stable and coherent short wavelength radiation is a great promise of the externally seeded free-electron laser. However, the fre- quency up-conversion efficiency is limited to a small number in a single stage setup. In this paper, we propose a new scheme to produce coherent hard X-ray FEL with two- beam based two-stage echo-enabled harmonic generation configuration. Electron beams with quite different proper- ties are separately used in each stage and a monochromator is adopted to purify the radiation from first stage for seeding the second stage. Three-dimensional start-to-end simulations have been performed with realistic parameters to show the feasibility of the proposed scheme. 展开更多
关键词 Seeded FEL EEHG Fresh beam Coherent hard x-ray
原文传递
Hard x-ray transmission curved crystal spectrometers(10–100 keV) for laser fusion experiments at the ShenGuang-Ⅲ laser facility 被引量:2
18
作者 Ming-hai Yu Guang-yue Hu +6 位作者 Ning An Feng Qian Yu-chi Wu Xiao-ding Zhang Yu-qiu Gu Qiu-ping Wang Jian Zheng 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2016年第1期9-16,共8页
Two transmission curved crystal spectrometers are designed to measure the hard x-ray emission in the laser fusion experiment of Compton radiography of implosion target on ShenGuang-III laser facility in China. Cylindr... Two transmission curved crystal spectrometers are designed to measure the hard x-ray emission in the laser fusion experiment of Compton radiography of implosion target on ShenGuang-III laser facility in China. Cylindrically curvedα-quartz(10–11) crystals with curvature radii of 150 and 300 mm are used to cover spectral ranges of 10–56 and17–100 ke V, respectively. The distance between the crystal and the x-ray source can be changed over a broad distance from 200 to 1500 mm. The optical design, including the integral reflectivity of the curved crystal, the sensitivity, and the spectral resolution of the spectrometers, is discussed. We also provide mechanic design details and experimental results using a Mo anode x-ray source. High-quality spectra were obtained. We confirmed that the spectral resolution can be improved by increasing the working distance, which is the distance between the recording medium and the Rowland circle. 展开更多
关键词 curved CRYSTAL SPECTROMETER hard x-ray laser FUSION
原文传递
Hard X-ray one dimensional nano-focusing at the SSRF using a WSi_2 /Si multilayer Laue lens 被引量:2
19
作者 黄秋实 李浩川 +11 位作者 宋竹青 朱京涛 王占山 李爱国 闫帅 毛成文 王华 闫芬 张玲 余笑寒 刘鹏 李明 《Chinese Physics C》 SCIE CAS CSCD 2013年第2期98-101,共4页
The multilayer Laue lens (MLL) is a novel diffraction optics which can realize nanometer focusing of hard X-rays with high efficiency. In this paper, a 7.9 μm-thick MLL with the outmost layer thickness of 15 nm is ... The multilayer Laue lens (MLL) is a novel diffraction optics which can realize nanometer focusing of hard X-rays with high efficiency. In this paper, a 7.9 μm-thick MLL with the outmost layer thickness of 15 nm is designed based on dynamical diffraction theory. The MLL is fabricated by first depositing the depth-graded multilayer using direct current (DC) magnetron sputtering technology. Then, the multilayer sample is sliced, and both cross-sections are thinned and polished to a depth of 35–41 μm. The focusing property of the MLL is measured at the Shanghai Synchrotron Facility (SSRF). One-dimensional (1D) focusing resolutions of 205 nm and 221 nm are obtained at E=14 keV and 18 keV, respectively. It demonstrates that the fabricated MLL can focus hard X-rays into nanometer scale. 展开更多
关键词 nano-focusing hard x-ray multilayer Laue lens synchrotron radiation diffraction
原文传递
Development of a fast electron bremsstrahlung diagnostic system based on LYSO and silicon photomultipliers during lower hybrid current drive for tokamak 被引量:1
20
作者 Weiwei FAN Bowen ZHENG +3 位作者 Jing CAO Shibiao TANG Qingwei YANG Zejie YIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第6期88-97,共10页
A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnos... A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnostic system is dedicated to study the FEB emission in the hard x-ray (HXR) energy range between 10 and 200 keV during the lower hybrid current drive.The system consists of a detection module and three data acquisition and processing (DAP)boards.The detection module consists of annulus LYSO-SiPM detector array and a 12-channel preamplifier module.The DAP boards upload the data to the host computer for displaying and storing through PXI bus.The time and space resolutions of the system are 10 ms and 4 cm,respectively.The experimental results can show the evolution over time and the spatial distribution of FEB.This paper presents the system performance and typical discharge results. 展开更多
关键词 DIAGNOSTIC system fast electron BREMSSTRAHLUNG hard x-ray HL-2A TOKAMAK
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部