AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens(IOL) implantation in uncommon cases.METHODS: Totally 24 pa...AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens(IOL) implantation in uncommon cases.METHODS: Totally 24 patients with high residual refractive error after cataract surgery with IOL implantation were examined. Twenty-two patients had a history of phacoemulsification and IOL implantation, and two had extra-capsular cataract extraction with IOL implantation. Detailed examination of preoperative medical records was done to explain the origin of the post-cataract refractive errors. All patients underwent photorefractire keratectomy(PRK) enhancement. The mean outcome measures were refraction, uncorretted visual acuity(UCVA), best corrected visual acuity(BCVA) and corneal transparency and follow up ranged from 1 to 8 y.RESULTS: The principal causes of residual ametropia was inexact IOL calculation in abnormal eyes with high myopia and congenital lens abnormalities, followed by corneal astigmatism both suture induced and preexisting. After cataract surgery and before the laser enhancement the mean spherical equivalent(SE) was-0.56±3 D ranging from-4.62 to +2.25 D in high myopic patients, instead it was-1±1.73 D ranging from-3.25 to +3.75 D in the astigmatic eyes, with a mean cylinder of-3.75±0 ranging from-3 to +5.50 D. After laser refractive surgery the mean SE was 0.1±0.73, ranging from-0.50 to +1.50 in the myopic group, and it was-0.50±0.57 ranging from-1.25 to +0.50 in astigmatic patients, with a mean cylinder of-0.25±0.75. In myopic patients the mean UCVA and BCVA were 0.038±0.072 logMAR and 0.018±0.04 respectively, both ranging from 0.10 to 0.0. In astigmatic patients, the mean UCVA and BCVA were 0.213±0.132 and 0.00±0.0 respectively, UCVA ranging from 0.50 to 0.22 and BCVA was 0.00. All patients presented normal corneal transparency. No ocular hypertension was detected and no corneal haze was observed. All registered values remained stable also at the end line evaluation.CONCLUSION: The excimer laser treatment of residual refractive errors after cataract surgery with IOL implantation in abnormal eyes resulted in satisfactory and stable visual outcome with good safety and efficacy.展开更多
A kind of leaching residue generated during high pressure acid leaching of laterite nickel ore is creatively prepared as blast furnace charge for ironmaking.Results show that the briquettes with uniform shape,compress...A kind of leaching residue generated during high pressure acid leaching of laterite nickel ore is creatively prepared as blast furnace charge for ironmaking.Results show that the briquettes with uniform shape,compressive strength higher than 72.3 N/pellet,and cracking temperature over 400℃can be obtained by the non-binder briquetting with water content of 12.2 wt.%and pressure of 30 MPa.After preheating at 975℃for 12 min and roasting at 1225℃for 15 min,the strength of the roasted briquettes can reach 2815 N/pellet,and the iron grade is 59.27 wt.%.And the sulfur content can be simultaneously reduced to 0.067 wt.%.The obtained briquettes achieve adequate reducibility index,reduction degradation index,reduction swelling index,softening and melting temperatures,which are suitable for blast furnace ironmaking.The results show that this method cannot only effectively treat the leaching residue to reduce the risk of environmental pollution,but also realize the utilization of leaching residue.展开更多
文摘AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens(IOL) implantation in uncommon cases.METHODS: Totally 24 patients with high residual refractive error after cataract surgery with IOL implantation were examined. Twenty-two patients had a history of phacoemulsification and IOL implantation, and two had extra-capsular cataract extraction with IOL implantation. Detailed examination of preoperative medical records was done to explain the origin of the post-cataract refractive errors. All patients underwent photorefractire keratectomy(PRK) enhancement. The mean outcome measures were refraction, uncorretted visual acuity(UCVA), best corrected visual acuity(BCVA) and corneal transparency and follow up ranged from 1 to 8 y.RESULTS: The principal causes of residual ametropia was inexact IOL calculation in abnormal eyes with high myopia and congenital lens abnormalities, followed by corneal astigmatism both suture induced and preexisting. After cataract surgery and before the laser enhancement the mean spherical equivalent(SE) was-0.56±3 D ranging from-4.62 to +2.25 D in high myopic patients, instead it was-1±1.73 D ranging from-3.25 to +3.75 D in the astigmatic eyes, with a mean cylinder of-3.75±0 ranging from-3 to +5.50 D. After laser refractive surgery the mean SE was 0.1±0.73, ranging from-0.50 to +1.50 in the myopic group, and it was-0.50±0.57 ranging from-1.25 to +0.50 in astigmatic patients, with a mean cylinder of-0.25±0.75. In myopic patients the mean UCVA and BCVA were 0.038±0.072 logMAR and 0.018±0.04 respectively, both ranging from 0.10 to 0.0. In astigmatic patients, the mean UCVA and BCVA were 0.213±0.132 and 0.00±0.0 respectively, UCVA ranging from 0.50 to 0.22 and BCVA was 0.00. All patients presented normal corneal transparency. No ocular hypertension was detected and no corneal haze was observed. All registered values remained stable also at the end line evaluation.CONCLUSION: The excimer laser treatment of residual refractive errors after cataract surgery with IOL implantation in abnormal eyes resulted in satisfactory and stable visual outcome with good safety and efficacy.
基金supported by the National Natural Science Foundation of China(51974371)the National Key R&D Program(No.2018YFC1900605)the Open Sharing Fund for the Large-scale Instruments and Equipments of Central South University(CSUZC202031).
文摘A kind of leaching residue generated during high pressure acid leaching of laterite nickel ore is creatively prepared as blast furnace charge for ironmaking.Results show that the briquettes with uniform shape,compressive strength higher than 72.3 N/pellet,and cracking temperature over 400℃can be obtained by the non-binder briquetting with water content of 12.2 wt.%and pressure of 30 MPa.After preheating at 975℃for 12 min and roasting at 1225℃for 15 min,the strength of the roasted briquettes can reach 2815 N/pellet,and the iron grade is 59.27 wt.%.And the sulfur content can be simultaneously reduced to 0.067 wt.%.The obtained briquettes achieve adequate reducibility index,reduction degradation index,reduction swelling index,softening and melting temperatures,which are suitable for blast furnace ironmaking.The results show that this method cannot only effectively treat the leaching residue to reduce the risk of environmental pollution,but also realize the utilization of leaching residue.