Determination of conditions for stable operation of induction motor resistance load using load flow and fuzzy techniques
1
作者 Livingstone M.H.NGOO +2 位作者 郭志忠 Geoffrey ANDOGAH 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第4期348-352,共5页
Discusses the significance of induction motor constant resistance (IM R) load on the lower part of the PV curve of a power system and determines the conditions for stable operation of IM R load using fuzzy techniques ... Discusses the significance of induction motor constant resistance (IM R) load on the lower part of the PV curve of a power system and determines the conditions for stable operation of IM R load using fuzzy techniques and load flow. 展开更多
关键词 induction motor resistance load PV curve power system instability and collapse load flow fuzzy method
下载PDF
Design and Development of an Intelligent Energy Management System for a Smart Grid to Enhance the Power Quality
2
作者 Nisha Vasudevan Vasudevan Venkatraman +5 位作者 A.Ramkumar T.Muthukumar A.Sheela M.Vetrivel R.J.Vijaya Saraswathi F.T.Josh 《Energy Engineering》 EI 2023年第8期1747-1761,共15页
MigroGrid(MG)has emerged to resolve the growing demand for energy.But because of its inconsistent output,it can result in various power quality(PQ)issues.PQ is a problem that is becoming more and more important for th... MigroGrid(MG)has emerged to resolve the growing demand for energy.But because of its inconsistent output,it can result in various power quality(PQ)issues.PQ is a problem that is becoming more and more important for the reliability of power systems that use renewable energy sources.Similarly,the employment of nonlinear loads will introduce harmonics into the system and,as a result,cause distortions in the current and voltage waveforms as well as low power quality issues in the supply system.Thus,this research focuses on power quality enhancement in the MG using hybrid shunt filters.However,the performance of the filter mainly depends upon the design,and stability of the controller.The efficiency of the proposed filter is enhanced by incorporating an enhanced adaptive fuzzy neural network(AFNN)controller.The performance of the proposed topology is examined in a MATLAB/Simulink environment,and experimental findings are provided to validate the effectiveness of this approach.Further,the results of the proposed controller are compared with Adaptive Fuzzy Back-Stepping(AFBS)and Adaptive Fuzzy Sliding(AFS)to prove its superiority over power quality improvement in MG.From the analysis,it can be observed that the proposed system reduces the total harmonic distortion by about 1.8%,which is less than the acceptable limit standard. 展开更多
关键词 Artificial intelligence resistive inductive load shunt hybrid filter smart grid adaptive fuzzy back-stepping power factor