In recent years,multi-modal flexible tactile sensors have become an important direction in the development of electronic skin because of their excellent sensitivity,flexibility and wearable properties.In this work,a h...In recent years,multi-modal flexible tactile sensors have become an important direction in the development of electronic skin because of their excellent sensitivity,flexibility and wearable properties.In this work,a humidity-pressure multi-modal flexible sensor based on polypyrrole(PPy)/Ti_(3)C_(2)T_(x) sensitive film packaged with porous polydimethylsiloxane(PDMS)is investigated by combining the sensitive structure generation mechanism of in situ polymerization to achieve the simultaneous detection of humidity and pressure,which has a sensitivity of 89,113.4Ω/%RH in a large humidity range of 0%-97%RH,and response/recovery time of 2.5/1.9 s.The tactile pressure sensing has a high sensitivity,a fast response of 67/52 ms,and a wide detection limit.The device also has excellent performance in terms of stability and repeatability,making it promising for respiratory pattern and motion detection.This work provides a new solution to address the construction of multi-modal tactile sensors with potential applications in the fields of medical health,epidemic prevention.展开更多
Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocesso...Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement.展开更多
Ammonia (NH3) is a toxic gas released in different industrial, agricultural and natural processes. It is also a biomarker for some diseases. These require NH3 sensors for health and safety reasons. To boost the sens...Ammonia (NH3) is a toxic gas released in different industrial, agricultural and natural processes. It is also a biomarker for some diseases. These require NH3 sensors for health and safety reasons. To boost the sensitiv- ity of solid-state sensors, the effective sensing area should be increased. Two methods are explored and compared using an evaporating pool of 0.5 mL NH4OH (28% NH3). In the first method an array of Si nanowires (Si NWA) is obtained via metal-assisted-electrochemical etching to increase the effective surface area. In the second method CVD graphene is suspended on top of the Si nanowires to act as a sensing layer. Both the effective surface area as well as the density of surface traps influences the amplitude of the response. The effective surface area of Si NWAs is 100 × larger than that of suspended graphene for the same top surface area, leading to a larger response in amp- litude by a factor of -7 notwithstanding a higher trap density in suspended graphene. The use of Si NWAs in- creases the response rate for both Si NWAs as well as the suspended graphene due to more effective NH3 diffu- sion processes.展开更多
基金supported by the National Natural Science Foundation of China(No.51777215)the Special Foundation of the Taishan Scholar Project(No.tsqn202211077)+1 种基金the Shandong Provincial Natural Science Foundation(No.ZR2023ME118)the Natural Science Foundation of Qingdao City(No.23-2-1-219-zyyd-jch).
文摘In recent years,multi-modal flexible tactile sensors have become an important direction in the development of electronic skin because of their excellent sensitivity,flexibility and wearable properties.In this work,a humidity-pressure multi-modal flexible sensor based on polypyrrole(PPy)/Ti_(3)C_(2)T_(x) sensitive film packaged with porous polydimethylsiloxane(PDMS)is investigated by combining the sensitive structure generation mechanism of in situ polymerization to achieve the simultaneous detection of humidity and pressure,which has a sensitivity of 89,113.4Ω/%RH in a large humidity range of 0%-97%RH,and response/recovery time of 2.5/1.9 s.The tactile pressure sensing has a high sensitivity,a fast response of 67/52 ms,and a wide detection limit.The device also has excellent performance in terms of stability and repeatability,making it promising for respiratory pattern and motion detection.This work provides a new solution to address the construction of multi-modal tactile sensors with potential applications in the fields of medical health,epidemic prevention.
文摘Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement.
基金financially supported by the National Natural Science Foundation of China(22125903,51872283,and 22109160)Dalian Innovation Support Plan for High Level Talents(2019RT09)+2 种基金Dalian National Laboratory For Clean Energy(DNL),CAS,DNL Cooperation Fund,CAS(DNL201912,DNL201915,DNL202016,and DNL202019),DICP(DICP I2020032)the Joint Fund of Yulin University and Dalian National Laboratory for Clean Energy(YLU-DNL Fund 2021002 and YLU-DNL Fund 2021009)China Postdoctoral Science Foundation(2021M693126)。
基金financial support of EPSRC via the EEE department
文摘Ammonia (NH3) is a toxic gas released in different industrial, agricultural and natural processes. It is also a biomarker for some diseases. These require NH3 sensors for health and safety reasons. To boost the sensitiv- ity of solid-state sensors, the effective sensing area should be increased. Two methods are explored and compared using an evaporating pool of 0.5 mL NH4OH (28% NH3). In the first method an array of Si nanowires (Si NWA) is obtained via metal-assisted-electrochemical etching to increase the effective surface area. In the second method CVD graphene is suspended on top of the Si nanowires to act as a sensing layer. Both the effective surface area as well as the density of surface traps influences the amplitude of the response. The effective surface area of Si NWAs is 100 × larger than that of suspended graphene for the same top surface area, leading to a larger response in amp- litude by a factor of -7 notwithstanding a higher trap density in suspended graphene. The use of Si NWAs in- creases the response rate for both Si NWAs as well as the suspended graphene due to more effective NH3 diffu- sion processes.