The resonance light-scattering (RLS) of human serum albumin (HSA) and bovine serum albumin (BSA) is reported for the first time, and applied to study photochemical reaction of HSA and BSA. The fact of photocrosslinkin...The resonance light-scattering (RLS) of human serum albumin (HSA) and bovine serum albumin (BSA) is reported for the first time, and applied to study photochemical reaction of HSA and BSA. The fact of photocrosslinking self-association effect in HSA and BSA solutions is identified by the enhancement of RLS. The fluorescence quenching at about 350 nm and 700 nm proves that tryptophan (Trp) residues are one of the photochemical activity sites in HSA and BSA molecules. The Rayleigh scattering (RS) spectra of HSA and BSA that were neglected in fluorescence spectra before are found at about 296 nm, 592 nm and 888 nm for the first time, and are of adventageous to studying the aggregation of HSA or BSA. The possible photochemical reaction mechanism is also proposed.展开更多
The reversible aggregation between dextran-conjugated CdSe quantum dots(Dex-CdSe-QDs) and concanavalin A(Con A) was explored based on the specific affinity of polysaccharide for Con A by resonance light-scattering...The reversible aggregation between dextran-conjugated CdSe quantum dots(Dex-CdSe-QDs) and concanavalin A(Con A) was explored based on the specific affinity of polysaccharide for Con A by resonance light-scattering technique.In this study,the aggregation of Dex-CdSe-QDs induced by Con A and sequential dissociation by glucose was determined over a wide range of dextran molecular mass(10-500 kDa).The results demonstrate that the sensitivity of lectin-dextran-modified-QDs interactions increase with dextran molecular mass,and an optimum dextran molecular mass is 500 kDa.展开更多
Chloride ion was determined by the resonance light scattering method.The results showed the RLS intensity of the blank solution was faint.While chloride ion was added,the RLS intensity enhanced quickly and was proport...Chloride ion was determined by the resonance light scattering method.The results showed the RLS intensity of the blank solution was faint.While chloride ion was added,the RLS intensity enhanced quickly and was proportional to the concentration of choloride ions.The assay is simple,rapid and sensitive with the linear range up to 14.0 μg/mL and the detection limit at 0.04 μg/mL.The recoveries of the method found to be in the range of 98.7%—102% with RSD between 1.1% and 2.2%.This assay was applied to the determination of chloride ions in acid copper plating bath and in tap water,and the results were satisfactory.展开更多
A method of enhanced effect on calciumion and phosphate anion by resonance light-scattering turbidimetry(RLST) was studied in this paper.The optimum reaction conditions and the quantitative relationships of the intens...A method of enhanced effect on calciumion and phosphate anion by resonance light-scattering turbidimetry(RLST) was studied in this paper.The optimum reaction conditions and the quantitative relationships of the intensities of RLST to the concentration of phosphate anion were established.The RLS intensity at 515nm is max and proportional to the concentration of phosphate anion.The method is simple and rapid with a detection limit of 0.00608μg/mL and a linear rang of 0.02~3.0μg/mL.It was applied to the determination of organophorus pesticide residues with satisfactory results.展开更多
The enhanced effect with Potassium and Na-TPB by Resonance Light Scattering Turbidimetry(RLST) based on Potassium and Na-TPB form hydrophobe sol system was studied in this paper.The optimum reaction conditions and t...The enhanced effect with Potassium and Na-TPB by Resonance Light Scattering Turbidimetry(RLST) based on Potassium and Na-TPB form hydrophobe sol system was studied in this paper.The optimum reaction conditions and the quantitative relationships of the intensities of RLS to the concentration of potassium were established.The RLS intensity at 578 nm is maximum and proportional to the concentration of potassium.The method is simple and rapid with a detection limit is 0.124×10-6mol/L and a linear range is 0.0~4.6×10-4mol/L.展开更多
基金the National Natural Science Foundation of China ! 29961001the Foundation for Talents Striding across the Century of Guangxi
文摘The resonance light-scattering (RLS) of human serum albumin (HSA) and bovine serum albumin (BSA) is reported for the first time, and applied to study photochemical reaction of HSA and BSA. The fact of photocrosslinking self-association effect in HSA and BSA solutions is identified by the enhancement of RLS. The fluorescence quenching at about 350 nm and 700 nm proves that tryptophan (Trp) residues are one of the photochemical activity sites in HSA and BSA molecules. The Rayleigh scattering (RS) spectra of HSA and BSA that were neglected in fluorescence spectra before are found at about 296 nm, 592 nm and 888 nm for the first time, and are of adventageous to studying the aggregation of HSA or BSA. The possible photochemical reaction mechanism is also proposed.
基金the Natural Science Foundation of Shanxi Province(No.2008011015-1) for financial support
文摘The reversible aggregation between dextran-conjugated CdSe quantum dots(Dex-CdSe-QDs) and concanavalin A(Con A) was explored based on the specific affinity of polysaccharide for Con A by resonance light-scattering technique.In this study,the aggregation of Dex-CdSe-QDs induced by Con A and sequential dissociation by glucose was determined over a wide range of dextran molecular mass(10-500 kDa).The results demonstrate that the sensitivity of lectin-dextran-modified-QDs interactions increase with dextran molecular mass,and an optimum dextran molecular mass is 500 kDa.
文摘Chloride ion was determined by the resonance light scattering method.The results showed the RLS intensity of the blank solution was faint.While chloride ion was added,the RLS intensity enhanced quickly and was proportional to the concentration of choloride ions.The assay is simple,rapid and sensitive with the linear range up to 14.0 μg/mL and the detection limit at 0.04 μg/mL.The recoveries of the method found to be in the range of 98.7%—102% with RSD between 1.1% and 2.2%.This assay was applied to the determination of chloride ions in acid copper plating bath and in tap water,and the results were satisfactory.
文摘A method of enhanced effect on calciumion and phosphate anion by resonance light-scattering turbidimetry(RLST) was studied in this paper.The optimum reaction conditions and the quantitative relationships of the intensities of RLST to the concentration of phosphate anion were established.The RLS intensity at 515nm is max and proportional to the concentration of phosphate anion.The method is simple and rapid with a detection limit of 0.00608μg/mL and a linear rang of 0.02~3.0μg/mL.It was applied to the determination of organophorus pesticide residues with satisfactory results.
文摘The enhanced effect with Potassium and Na-TPB by Resonance Light Scattering Turbidimetry(RLST) based on Potassium and Na-TPB form hydrophobe sol system was studied in this paper.The optimum reaction conditions and the quantitative relationships of the intensities of RLS to the concentration of potassium were established.The RLS intensity at 578 nm is maximum and proportional to the concentration of potassium.The method is simple and rapid with a detection limit is 0.124×10-6mol/L and a linear range is 0.0~4.6×10-4mol/L.