期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Two-point Dixon and six-point Dixon magnetic resonance techniques in the detection,quantification and grading of hepatic steatosis
1
作者 Mohamed Elfaal Alanna Supersad +6 位作者 Craig Ferguson Stephanie Locas Florin Manolea Mitchell P Wilson Medica Sam Wendy Tu Gavin Low 《World Journal of Radiology》 2023年第10期293-303,共11页
BACKGROUND Hepatic steatosis is a very common problem worldwide.AIM To assess the performance of two-and six-point Dixon magnetic resonance(MR)techniques in the detection,quantification and grading of hepatic steatosi... BACKGROUND Hepatic steatosis is a very common problem worldwide.AIM To assess the performance of two-and six-point Dixon magnetic resonance(MR)techniques in the detection,quantification and grading of hepatic steatosis.METHODS A single-center retrospective study was performed in 62 patients with suspected parenchymal liver disease.MR sequences included two-point Dixon,six-point Dixon,MR spectroscopy(MRS)and MR elastography.Fat fraction(FF)estimates on the Dixon techniques were compared to the MRS-proton density FF(PDFF).Statistical tests used included Pearson’s correlation and receiver operating characteristic.RESULTS FF estimates on the Dixon techniques showed excellent correlation(≥0.95)with MRS-PDFF,and excellent accuracy[area under the receiver operating characteristic(AUROC)≥0.95]in:(1)Detecting steatosis;and(2)Grading severe steatosis,(P<0.001).In iron overload,two-point Dixon was not evaluable due to confounding T2*effects.FF estimates on six-point Dixon vs MRS-PDFF showed a moderate correlation(0.82)in iron overload vs an excellent correlation(0.97)without iron overload,(P<0.03).The accuracy of six-point Dixon in grading mild steatosis improved(AUROC:0.59 to 0.99)when iron overload cases were excluded.The excellent correlation(>0.9)between the Dixon techniques vs MRSPDFF did not change in the presence of liver fibrosis(P<0.01).CONCLUSION Dixon techniques performed satisfactorily for the evaluation of hepatic steatosis but with exceptions. 展开更多
关键词 Chemical shift encoded Dixon magnetic resonance techniques Hepatic steatosis Liver fat quantification Magnetic resonance spectroscopy Proton density fat fraction ULTRASOUND
下载PDF
Progresses of Functional Magnetic Resonance Imaging Diagnosis in Breast Cancer
2
作者 Qianfei Hu Sibin Liu 《Yangtze Medicine》 2020年第2期85-96,共12页
Breast cancer is the most common malignant tumor that threatens women’s health. Breast magnetic resonance imaging (MRI) is a commonly used method recommended for the diagnosis of breast cancer. Diffusion weighted ima... Breast cancer is the most common malignant tumor that threatens women’s health. Breast magnetic resonance imaging (MRI) is a commonly used method recommended for the diagnosis of breast cancer. Diffusion weighted imaging (DWI) and dynamic enhanced magnetic resonance imaging (DCE-MRI) are now widely used. At present, with the continuous advancement of magnetic resonance technology, Magnetic resonance spectroscopy (MRS), Perfusion weighted imaging (PWI), Positron emission tomography-magnetic resonance imaging (PET-MRI) and so on are gradually being used in clinical practice. Mammography imaging and imaging genomics are hot topics. This article will briefly introduce several functional magnetic resonance techniques and their latest applications. 展开更多
关键词 Breast Cancer Functional Magnetic Resonance techniques Diagnostic Imaging
下载PDF
Endovascular Application of Magnetic Resonance Double Mismatch Technique for Acute Anterior Circulation Large Vessel Occlusion with Cerebral Infarction in an Unknown Time Window
3
作者 Xiangkong Song Qing Zhang +2 位作者 Lilin Gao Jie Qi Guoqing Wang 《Journal of Clinical and Nursing Research》 2020年第5期43-46,共4页
Objective:To investigate the clinical effects of applying the magnetic resonance double mismatch technique to endovascular treatment of acute anterior circulation,large vessel occlusion with cerebral infarction in an ... Objective:To investigate the clinical effects of applying the magnetic resonance double mismatch technique to endovascular treatment of acute anterior circulation,large vessel occlusion with cerebral infarction in an unknown time window.Methods:The research work was carried out in our hospital,the work was carried out from November 2018 to November 2019,the patients with acute anterior circulation large vessel occlusion with cerebral infarction who were treated in our hospital during this period,100 patients,50 patients with an unknown time window and 50 patients with definite time window were selected,and they were named as the experimental and control groups,given different examination methods,were given to investigate the clinical treatment effect.Results:Patients’data on HIHSS score before treatment,the incidence of intracranial hemorrhage and rate of Mrs≤2 rating after 90 days of treatment were not significantly different(P>0.05),which was not meaningful.The differences in data between the two groups concerning HIHSS scores were relatively significant before,and after treatment(P<0.05).Conclusion:The magnetic resonance double mismatch technique will be applied in the endovascular treatment of acute anterior circulation large vessel occlusion with cerebral infarction of unknown time window. 展开更多
关键词 Magnetic resonance double mismatch technique Unknown time window Acute anterior circulation large vessel occlusion with cerebral infarction Therapeutic effect
下载PDF
A New HFRT Algorithm Based on Maximal Overlap Discrete Wavelet Packet Transformation
4
作者 Hong-Tao Zhang Jian-Ming Liao 《Journal of Electronic Science and Technology of China》 2007年第2期146-148,共3页
The high frequency resonant technique (HFRT) algorithm is a popular technique for fault-detection and is widely applied in mechanism systems and industrial constructions. In this paper, a new HFRT algorithm based on... The high frequency resonant technique (HFRT) algorithm is a popular technique for fault-detection and is widely applied in mechanism systems and industrial constructions. In this paper, a new HFRT algorithm based on maximal overlap discrete wavelet packet transformation (MODWPT) is developed. By the simulation test for soil embedded pipes fault-detection, it is shown that the performance of newly proposed HFRT algorithms is more sensitive to early defects than the traditional HFRT methods based on the Hilbert transform. 展开更多
关键词 FAULT-DETECTION high frequency resonant technique maximal overlap wavelet packet transforms soil embedded pipe.
下载PDF
Resonator integrated optic gyro based on multilevel laser frequency lock-in technique 被引量:5
5
作者 潘梓文 张成飞 +4 位作者 谢成峰 郑永秋 李昊天 唐军 刘俊 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第4期16-19,共4页
The resonator integrated optic gyros(RIOGs) based on the Sagnac effect have gained extensive attention in navigation and guidance systems due to their predominant advantages: high theoretical accuracy and simple in... The resonator integrated optic gyros(RIOGs) based on the Sagnac effect have gained extensive attention in navigation and guidance systems due to their predominant advantages: high theoretical accuracy and simple integration. However, the problems of losing lock and low lock-in accuracy are the bottlenecks, which restrict the development of digital RIOGs. Therefore, a multilevel laser frequency lock-in technique has been proposed in this Letter to address these problems. The experimental results show that lock-in accuracy can be improved one order higher and without losing lock in a variable temperature environment. Then, a digital miniaturized RIOG prototype(18 cm × 18 cm × 20 cm) has been produced, and long-term(1 h) bias stability of 26.6 deg/h is successfully demonstrated. 展开更多
关键词 resonator integrated optic gyro based on multilevel laser frequency lock-in technique FSR WRR
原文传递
Suppression of backscattering induced noise by the sideband locking technique in a resonant fiber optic gyroscope 被引量:6
6
作者 刘宁 牛燕雄 +2 位作者 冯丽爽 焦洪臣 王潇 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第1期38-42,共5页
Polarization fluctuation induced noise and backscattering-induced noise are the dominant noises in resonant fiber optic gyroscopes. This Letter proposes a new method to suppress the carrier and backscattering induced ... Polarization fluctuation induced noise and backscattering-induced noise are the dominant noises in resonant fiber optic gyroscopes. This Letter proposes a new method to suppress the carrier and backscattering induced noise by the sideband locking technique. Besides choosing an optimized modulation depth and different clockwise and counterclockwise modulation frequencies, the sideband is locked to the cavity resonance. With the proper modulation frequency, the carrier frequency component locates at a position far away from the resonant frequency, and then it is suppressed by the cavity itself, which can be taken as a bandpass filter. The amplitude of the carrier frequency can be suppressed by 20–25 d B additionally by the cavity and the total intensity suppression ratio can reach 115.74 d B. The backscattering induced noise can be eliminated for the adoption of different frequencies. The method can realize a stable and high suppression ratio without high requirements for parameter accuracy or device performance. 展开更多
关键词 Suppression of backscattering induced noise by the sideband locking technique in a resonant fiber optic gyroscope CCW
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部