This paper presents an identification method of the scalar Preisach model to consider the effect of reversible magnetization in the process of distribution function identification.By reconsidering the identification p...This paper presents an identification method of the scalar Preisach model to consider the effect of reversible magnetization in the process of distribution function identification.By reconsidering the identification process by stripping the influence of reversible components from the measurement data,the Preisach distribution function is identified by the pure irreversible components.In this way,the simulation accuracy of both limiting hysteresis loops and the inner internal symmetrical small hysteresis loop is ensured.Furthermore,through a discrete Preisach plane with a hybrid discretization method,the irreversible magnetic flux density components are computed more efficiently through the improved Preisach model.Finally,the proposed method results are compared with the traditional method and the traditional method considering reversible magnetization and validated by the laboratory test for the B30P105 electrical steel by Epstein frame.展开更多
Background: After a live birth, there is much unsatisfied interest in, and unmet family planning need for contraception. Waiting at least for 24 months before attempting the next pregnancy was recommended to reduce th...Background: After a live birth, there is much unsatisfied interest in, and unmet family planning need for contraception. Waiting at least for 24 months before attempting the next pregnancy was recommended to reduce the risk of adverse maternal, perinatal and infant outcomes. The purpose of this study was to assess the determinants of long acting reversible contraception method use among mothers in extended postpartum period in Durame Town, Southern Ethiopia. Methods: A community based cross sectional study was conducted in Durame Town, Southern Ethiopia in December, 2014. Systematic random sampling technique was employed to recruit a total 460 study participants. Structured and pretested questioner was used to collect the data. Descriptive statistics was employed to characterize the study population using frequencies and proportions. Bivariate logistic regression analysis was conducted to identify all possible factors affecting utilization of LARC method. Multivariable logistic regression model was developed to control the confounding variables. Adjusted Odds Ratio (AOR) with 95% Confidence Interval (CI) was computed in identifying the real factors associated with use of LARC methods. Results: In this study we found that the prevalence of LARC method use among mothers during their extended postpartum period was 36.7% (95%CI: 32.2, 41.0). The unmet family planning need of mothers in the extended postpartum period was 123 (27.9%). The odds of using LARC by literate mother were four fold higher than their counterpart illiterate mothers (AOR 4.09 95%CI: 1.68, 9.58, P value < 0.001). The odds of mother who had pervious experiences of using LARC were up to eight folds higher than mother never used LARC methods (AOR 7.84 95% CI: 3.78, 16.23, P value< 0.001). Mother who received counseling service on LARC methods during delivery was up to three times more likely to utilize the services than not counseled (AOR 3.29 95% CI: 1.53, 7.03, P value < 0.001). And odds of mothers who received counseling service on LARC during immediate postpartum period were up to five fold more likely to opt method than never got the counseling service (AOR 4.55 95 % CI: 1.94, 10.66, P value < 0.001). Conclusions: In the study area, about one third of mothers utilized LARC methods during their extended postpartum period. Another one third of mother had unmet need for family planning. Participant’s education, previous history of using LARC methods, receiving counseling services on LARC during delivery and immediate postpartum periods were found major determinant for LARC use. Educating women, providing counseling service on LARC methods during antenatal, delivery and postnatal were recommended.展开更多
This paper discusses the inheritance and application of Chinese character reverse contrast typeface style.It begins by analyzing the visual features of Western reverse contrast typeface styles,with a focus on Caslon I...This paper discusses the inheritance and application of Chinese character reverse contrast typeface style.It begins by analyzing the visual features of Western reverse contrast typeface styles,with a focus on Caslon Italian and French Clarendon,providing a Western perspective reference for subsequent Chinese character reverse contrast typeface style designs.The paper then traces the origins of the Chinese reverse contrast style,from the calligraphy style"Lacquer Script"to the earliest printing type"フワンテール形",exploring the historical background and cultural significance of the Chinese reverse contrast style.In the methodology section of Chinese character reverse contrast typeface style design,the discussion is conducted from two dimensions:inheritance and application.In terms of inheritance,through an in-depth analysis of"Lacquer Script"and"フワンテール形"typeface style,the paper summarizes three basic theories for modern Chinese character reverse contrast typeface style design.In the application section,it examines in detail the two most influential recent typeface styles,"Ribaasu"and"Basic Artistic",outlining three directions of application:extreme horizontal stroke variations,exaggerated contrast,and diverse decorative strokes,showcasing new directions and possibilities for Chinese character reverse contrast typeface style design.This paper not only reviews the developmental history of the Chinese character reverse contrast typeface style but also analyzes the design methodology of Chinese character reverse contrast typeface style through specific case studies.展开更多
Upconversion luminescence(UCL)materials have the potential for many applications due to their unique optical properties.Some technical challenges such as complex synthesis with low yield and nondegradability need to b...Upconversion luminescence(UCL)materials have the potential for many applications due to their unique optical properties.Some technical challenges such as complex synthesis with low yield and nondegradability need to be addressed for practical use.Here,we report for the first time a minimalist method for large-scale synthesis of Cs_(2)NaErCl_(6)UCL crystals with almost 100%yield,simply by dissolving metal chlorides in water and then drying,referred to as the“dissolve-dry”method.Cs_(2)NaErCl_(6)crystals produced under such mild conditions exhibited bright UCL at either 808 or 980 nm irradiation.UCL was achieved through an excited state absorption process,and the excellent performance was mainly attributed to the large unit cells of the crystals and the long lifetime of Er^(3+)excited energy levels.Moreover,the synthesis was reversible and could be scaled up unlimitedly,making it suitable for industrial applications,with recyclable products.The recyclable application of Cs_(2)NaErCl_(6)crystals as a luminescent medium in near-infrared light-emitting diode excitable upconversion devices was demonstrated based on its excellent recyclability.Our work not only provides a new strategy for large-scale synthesis of UCL crystals but also demonstrates the recyclability of this material and its related applications.展开更多
With the technology support of virtual reality and ANSYS software, an example on the simulation of temperature distribution of casting system during the solidification process was provided, which took the latent heat ...With the technology support of virtual reality and ANSYS software, an example on the simulation of temperature distribution of casting system during the solidification process was provided, which took the latent heat of phase change, the conditions for convection, and the interface heat transfer coefficient into consideration. The result of ANSYS was found to agree well with the test data. This research offers an unorthodox way or "reverse method" of defining the relevant thermal physical coefficient.展开更多
The main purpose of reverse engineering is to convert discrete data pointsinto piecewise smooth, continuous surface models. Before carrying out model reconstruction it issignificant to extract geometric features becau...The main purpose of reverse engineering is to convert discrete data pointsinto piecewise smooth, continuous surface models. Before carrying out model reconstruction it issignificant to extract geometric features because the quality of modeling greatly depends on therepresentation of features. Some fitting techniques of natural quadric surfaces with least-squaresmethod are described. And these techniques can be directly used to extract quadric surfaces featuresduring the process of segmentation for point cloud.展开更多
An efficient hybrid time reversal(TR) imaging method based on signal subspace and noise subspace is proposed for electromagnetic superresolution detecting and imaging. First, the locations of targets are estimated b...An efficient hybrid time reversal(TR) imaging method based on signal subspace and noise subspace is proposed for electromagnetic superresolution detecting and imaging. First, the locations of targets are estimated by the transmitting-mode decomposition of the TR operator(DORT) method employing the signal subspace. Then, the TR multiple signal classification(TR-MUSIC)method employing the noise subspace is used in the estimated target area to get the superresolution imaging of targets. Two examples with homogeneous and inhomogeneous background mediums are considered, respectively. The results show that the proposed hybrid method has advantages in CPU time and memory cost because of the combination of rough and fine imaging.展开更多
In this study, the CaP/pDNA nanoparticles were prepared using Triton X-100/Butanol/Cyclohexane/Water reverse microemulsion system. Optimization of preparation conditions was based on evaluation of particle size by Box...In this study, the CaP/pDNA nanoparticles were prepared using Triton X-100/Butanol/Cyclohexane/Water reverse microemulsion system. Optimization of preparation conditions was based on evaluation of particle size by Box–Behnken design method. The particle sizes of the optimized CaP/pDNA nanoparticles were found to be 60.23 ± 4.72 nm, polydispersity index was 0.252 and pDNA encapsulate efficiency was more than 90%. The optimized CaP/pDNA nanoparticles have pH sensitivity and biocompatibility. Further, optimized CaP/pDNA nanoparticles showed higher transfection efficiency.展开更多
To find out and improve the flow characteristics inside the intake system of cylinder head,the application of computational fluid dynamics(CFD)in the evaluation and optimization of the reconstructed intake system base...To find out and improve the flow characteristics inside the intake system of cylinder head,the application of computational fluid dynamics(CFD)in the evaluation and optimization of the reconstructed intake system based on slicing reverse method was proposed.The flow characteristics were found out through CFD,and the velocity vector field,pressure field and turbulent kinetic energy field for different valve lifts were discussed,which were in good agreement with experimental data,and the quality of reconstruction was evaluated.In order to improve its flow characteristic,an optimization plan was proposed.The results show that the flow characteristics after optimization are obviously improved.The results can provide a reference for the design and optimization of the intake system of cylinder head.展开更多
This paper proposes a two-step general framework for reversible data hiding(RDH)schemes with controllable contrast enhancement.The first step aims at preserving visual perception as much as possible on the basis of ac...This paper proposes a two-step general framework for reversible data hiding(RDH)schemes with controllable contrast enhancement.The first step aims at preserving visual perception as much as possible on the basis of achieving high embedding capacity(EC),while the second step is used for increasing image contrast.In the second step,some peak-pairs are utilized so that the histogram of pixel values is modified to perform histogram equalization(HE),which would lead to the image contrast enhancement.However,for HE,the utilization of some peak-pairs easily leads to over-enhanced image contrast when a large number of bits are embedded.Therefore,in our proposed framework,contrast over-enhancement is avoided by controlling the degree of contrast enhancement.Since the second step can only provide a small amount of data due to controlled contrast enhancement,the first one helps to achieve a large amount of data without degrading visual quality.Any RDH method which can achieve high EC while preserve good visual quality,can be selected for the first step.In fact,Gao et al.’s method is a special case of our proposed framework.In addition,two simple and commonly-used RDH methods are also introduced to further demonstrate the generalization of our framework.展开更多
The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode arr...The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug.展开更多
Intrinsic attenuation of the earth causes energy loss and phase distortion in seismic wave propagation.To obtain high-resolution imaging results,these negative effects must be considered during reverse time migration(...Intrinsic attenuation of the earth causes energy loss and phase distortion in seismic wave propagation.To obtain high-resolution imaging results,these negative effects must be considered during reverse time migration(RTM).We can easily implement attenuation-compensated RTM using the constant Q viscoacoustic wave equation with decoupled amplitude attenuation and phase dispersion terms.However,the nonphysical amplitude-compensation process will inevitably amplify the high-frequency noise in the wavefield in an exponential form,causing the numerical simulation to become unstable.This is due to the fact that the amplitude of the compensation grows exponentially with frequency.In order to achieve stable attenuation-compensated RTM,we modify the analytic expression of the attenuation compensation extrapolation operator and make it only compensate for amplitude loss within the effective frequency band.Based on this modified analytic formula,we then derive an explicit time-space domain attenuation compensation extrapolation operator.Finally,the implementation procedure of stable attenuation-compensated RTM is presented.In addition to being simple to implement,the newly proposed attenuation-compensated extrapolation operator is superior to the conventional low-pass filter in suppressing random noise,which will further improve the imaging resolution.We use two synthetic and one land seismic datasets to verify the stability and effectiveness of the proposed attenuationcompensated RTM in improving imaging resolution in viscous media.展开更多
The research was carried out to establish a new reverse phase-HPLC stability indicating method for quantifying Bimatoprost & Timolol in ophthalmic solution. The experiment of Bimatoprost & Timolol in ophthalmi...The research was carried out to establish a new reverse phase-HPLC stability indicating method for quantifying Bimatoprost & Timolol in ophthalmic solution. The experiment of Bimatoprost & Timolol in ophthalmic solution method development was determined on Waters HPLC instrument using a UV Detector. The separation was done by using L11, Zorbex SB phenyl (4.6 mm × 250 mm internal diameter) 5 μm analytical column, containing mobile phase of Phosphate buffer (0.02 M), methanol, and acetonitrile [50:30:20 % v/v]. The method was run at 1 ml·min<sup>-1</sup> at 210 nm for Bimatoprost and 295 nm for Timolol for detection. The drug was eluted at 10.81 min for Bimatoprost and 3.77 min for Timolol. After developing the method, it was assured for the intended use by validation, which was done according to ICH Q2B guidelines. The analytical parameters checked were Specificity/Selectivity, linearity, Range, accuracy, ruggedness, and robustness. It was observed that the response of the detector was linear in the range of 6 - 18 μg/ml with a correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability-indicating assay method was established by using the samples generated by the forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative, and photolytic degradation, and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the quantitative analysis of Bimatoprost 0.3% + Timolol 0.5% Ophthalmic Solution drugs for pharmaceutical use. Currently, there is no official method for Bimatoprost & Timolol combination products in USP or BP. Available research work related to single Bimatoprost or Timolol products was not suitable for testing Bimatoprost and Timolol combination drugs. Additionally, there is no stability-indicating method to test Bimatoprost & Timolol combination products which insist us to do research and develop a new reverse phase-HPLC indicating method which will be faster and more accurate.展开更多
基金supported by the National Natural Science Foundation of China under Grant 52007102,52207012by the State Key Laboratory of Reliability and Intelligence of Electrical Equipment under Grant EERIKF2021015。
文摘This paper presents an identification method of the scalar Preisach model to consider the effect of reversible magnetization in the process of distribution function identification.By reconsidering the identification process by stripping the influence of reversible components from the measurement data,the Preisach distribution function is identified by the pure irreversible components.In this way,the simulation accuracy of both limiting hysteresis loops and the inner internal symmetrical small hysteresis loop is ensured.Furthermore,through a discrete Preisach plane with a hybrid discretization method,the irreversible magnetic flux density components are computed more efficiently through the improved Preisach model.Finally,the proposed method results are compared with the traditional method and the traditional method considering reversible magnetization and validated by the laboratory test for the B30P105 electrical steel by Epstein frame.
文摘Background: After a live birth, there is much unsatisfied interest in, and unmet family planning need for contraception. Waiting at least for 24 months before attempting the next pregnancy was recommended to reduce the risk of adverse maternal, perinatal and infant outcomes. The purpose of this study was to assess the determinants of long acting reversible contraception method use among mothers in extended postpartum period in Durame Town, Southern Ethiopia. Methods: A community based cross sectional study was conducted in Durame Town, Southern Ethiopia in December, 2014. Systematic random sampling technique was employed to recruit a total 460 study participants. Structured and pretested questioner was used to collect the data. Descriptive statistics was employed to characterize the study population using frequencies and proportions. Bivariate logistic regression analysis was conducted to identify all possible factors affecting utilization of LARC method. Multivariable logistic regression model was developed to control the confounding variables. Adjusted Odds Ratio (AOR) with 95% Confidence Interval (CI) was computed in identifying the real factors associated with use of LARC methods. Results: In this study we found that the prevalence of LARC method use among mothers during their extended postpartum period was 36.7% (95%CI: 32.2, 41.0). The unmet family planning need of mothers in the extended postpartum period was 123 (27.9%). The odds of using LARC by literate mother were four fold higher than their counterpart illiterate mothers (AOR 4.09 95%CI: 1.68, 9.58, P value < 0.001). The odds of mother who had pervious experiences of using LARC were up to eight folds higher than mother never used LARC methods (AOR 7.84 95% CI: 3.78, 16.23, P value< 0.001). Mother who received counseling service on LARC methods during delivery was up to three times more likely to utilize the services than not counseled (AOR 3.29 95% CI: 1.53, 7.03, P value < 0.001). And odds of mothers who received counseling service on LARC during immediate postpartum period were up to five fold more likely to opt method than never got the counseling service (AOR 4.55 95 % CI: 1.94, 10.66, P value < 0.001). Conclusions: In the study area, about one third of mothers utilized LARC methods during their extended postpartum period. Another one third of mother had unmet need for family planning. Participant’s education, previous history of using LARC methods, receiving counseling services on LARC during delivery and immediate postpartum periods were found major determinant for LARC use. Educating women, providing counseling service on LARC methods during antenatal, delivery and postnatal were recommended.
文摘This paper discusses the inheritance and application of Chinese character reverse contrast typeface style.It begins by analyzing the visual features of Western reverse contrast typeface styles,with a focus on Caslon Italian and French Clarendon,providing a Western perspective reference for subsequent Chinese character reverse contrast typeface style designs.The paper then traces the origins of the Chinese reverse contrast style,from the calligraphy style"Lacquer Script"to the earliest printing type"フワンテール形",exploring the historical background and cultural significance of the Chinese reverse contrast style.In the methodology section of Chinese character reverse contrast typeface style design,the discussion is conducted from two dimensions:inheritance and application.In terms of inheritance,through an in-depth analysis of"Lacquer Script"and"フワンテール形"typeface style,the paper summarizes three basic theories for modern Chinese character reverse contrast typeface style design.In the application section,it examines in detail the two most influential recent typeface styles,"Ribaasu"and"Basic Artistic",outlining three directions of application:extreme horizontal stroke variations,exaggerated contrast,and diverse decorative strokes,showcasing new directions and possibilities for Chinese character reverse contrast typeface style design.This paper not only reviews the developmental history of the Chinese character reverse contrast typeface style but also analyzes the design methodology of Chinese character reverse contrast typeface style through specific case studies.
基金supported by financial aid from the National Natural Science Foundation of China(grant nos.22020102003 and 21834007)the Jilin Province Youth Science and Technology Talent support project(grant no.QT202229)the Program of Science and Technology Development Plan of Jilin Province of China(grant no.YDZJ202302CXJD065).
文摘Upconversion luminescence(UCL)materials have the potential for many applications due to their unique optical properties.Some technical challenges such as complex synthesis with low yield and nondegradability need to be addressed for practical use.Here,we report for the first time a minimalist method for large-scale synthesis of Cs_(2)NaErCl_(6)UCL crystals with almost 100%yield,simply by dissolving metal chlorides in water and then drying,referred to as the“dissolve-dry”method.Cs_(2)NaErCl_(6)crystals produced under such mild conditions exhibited bright UCL at either 808 or 980 nm irradiation.UCL was achieved through an excited state absorption process,and the excellent performance was mainly attributed to the large unit cells of the crystals and the long lifetime of Er^(3+)excited energy levels.Moreover,the synthesis was reversible and could be scaled up unlimitedly,making it suitable for industrial applications,with recyclable products.The recyclable application of Cs_(2)NaErCl_(6)crystals as a luminescent medium in near-infrared light-emitting diode excitable upconversion devices was demonstrated based on its excellent recyclability.Our work not only provides a new strategy for large-scale synthesis of UCL crystals but also demonstrates the recyclability of this material and its related applications.
文摘With the technology support of virtual reality and ANSYS software, an example on the simulation of temperature distribution of casting system during the solidification process was provided, which took the latent heat of phase change, the conditions for convection, and the interface heat transfer coefficient into consideration. The result of ANSYS was found to agree well with the test data. This research offers an unorthodox way or "reverse method" of defining the relevant thermal physical coefficient.
基金This project is supported by Research Foundation for Doctoral Program of Higher Education, China (No.98033532)
文摘The main purpose of reverse engineering is to convert discrete data pointsinto piecewise smooth, continuous surface models. Before carrying out model reconstruction it issignificant to extract geometric features because the quality of modeling greatly depends on therepresentation of features. Some fitting techniques of natural quadric surfaces with least-squaresmethod are described. And these techniques can be directly used to extract quadric surfaces featuresduring the process of segmentation for point cloud.
基金supported by the National Natural Science Foundation of China(6130127161331007)+2 种基金the Specialized Research Fund for the Doctoral Program of Higher Education of China(2011018512000820120185130001)the Fundamental Research Funds for Central Universities(ZYGX2012J043)
文摘An efficient hybrid time reversal(TR) imaging method based on signal subspace and noise subspace is proposed for electromagnetic superresolution detecting and imaging. First, the locations of targets are estimated by the transmitting-mode decomposition of the TR operator(DORT) method employing the signal subspace. Then, the TR multiple signal classification(TR-MUSIC)method employing the noise subspace is used in the estimated target area to get the superresolution imaging of targets. Two examples with homogeneous and inhomogeneous background mediums are considered, respectively. The results show that the proposed hybrid method has advantages in CPU time and memory cost because of the combination of rough and fine imaging.
基金the Natural Science Foundation Committee of China for the financial support (No.81173004 and No.81202483)
文摘In this study, the CaP/pDNA nanoparticles were prepared using Triton X-100/Butanol/Cyclohexane/Water reverse microemulsion system. Optimization of preparation conditions was based on evaluation of particle size by Box–Behnken design method. The particle sizes of the optimized CaP/pDNA nanoparticles were found to be 60.23 ± 4.72 nm, polydispersity index was 0.252 and pDNA encapsulate efficiency was more than 90%. The optimized CaP/pDNA nanoparticles have pH sensitivity and biocompatibility. Further, optimized CaP/pDNA nanoparticles showed higher transfection efficiency.
基金“Strategic Cooperation of Science and Technology between Nanchong City and Southwest Petroleum University 2018” Special Fund Project,China(Nos.18SXHZ0030,18SXHZ0054)
文摘To find out and improve the flow characteristics inside the intake system of cylinder head,the application of computational fluid dynamics(CFD)in the evaluation and optimization of the reconstructed intake system based on slicing reverse method was proposed.The flow characteristics were found out through CFD,and the velocity vector field,pressure field and turbulent kinetic energy field for different valve lifts were discussed,which were in good agreement with experimental data,and the quality of reconstruction was evaluated.In order to improve its flow characteristic,an optimization plan was proposed.The results show that the flow characteristics after optimization are obviously improved.The results can provide a reference for the design and optimization of the intake system of cylinder head.
基金This work was supported in part by National NSF of China(Nos.61872095,61872128,61571139 and 61201393)New Star of Pearl River on Science and Technology of Guangzhou(No.2014J2200085)+2 种基金the Open Project Program of Shenzhen Key Laboratory of Media Security(Grant No.ML-2018-03)the Opening Project of Guang Dong Province Key Laboratory of Information Security Technology(Grant No.2017B030314131-15)Natural Science Foundation of Xizang(No.2016ZR-MZ-01).
文摘This paper proposes a two-step general framework for reversible data hiding(RDH)schemes with controllable contrast enhancement.The first step aims at preserving visual perception as much as possible on the basis of achieving high embedding capacity(EC),while the second step is used for increasing image contrast.In the second step,some peak-pairs are utilized so that the histogram of pixel values is modified to perform histogram equalization(HE),which would lead to the image contrast enhancement.However,for HE,the utilization of some peak-pairs easily leads to over-enhanced image contrast when a large number of bits are embedded.Therefore,in our proposed framework,contrast over-enhancement is avoided by controlling the degree of contrast enhancement.Since the second step can only provide a small amount of data due to controlled contrast enhancement,the first one helps to achieve a large amount of data without degrading visual quality.Any RDH method which can achieve high EC while preserve good visual quality,can be selected for the first step.In fact,Gao et al.’s method is a special case of our proposed framework.In addition,two simple and commonly-used RDH methods are also introduced to further demonstrate the generalization of our framework.
文摘The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug.
基金supported by the Marine S&T Fund of Shandong Province for Pilot National Laboratory for Marine Science and Technology(Qingdao)(No.2021QNLM020001)the Major Scientific and Technological Projects of Shandong Energy Group(No.SNKJ2022A06-R23)the Major Scientific and Technological Projects of CNPC(No.ZD2019-183-003).
文摘Intrinsic attenuation of the earth causes energy loss and phase distortion in seismic wave propagation.To obtain high-resolution imaging results,these negative effects must be considered during reverse time migration(RTM).We can easily implement attenuation-compensated RTM using the constant Q viscoacoustic wave equation with decoupled amplitude attenuation and phase dispersion terms.However,the nonphysical amplitude-compensation process will inevitably amplify the high-frequency noise in the wavefield in an exponential form,causing the numerical simulation to become unstable.This is due to the fact that the amplitude of the compensation grows exponentially with frequency.In order to achieve stable attenuation-compensated RTM,we modify the analytic expression of the attenuation compensation extrapolation operator and make it only compensate for amplitude loss within the effective frequency band.Based on this modified analytic formula,we then derive an explicit time-space domain attenuation compensation extrapolation operator.Finally,the implementation procedure of stable attenuation-compensated RTM is presented.In addition to being simple to implement,the newly proposed attenuation-compensated extrapolation operator is superior to the conventional low-pass filter in suppressing random noise,which will further improve the imaging resolution.We use two synthetic and one land seismic datasets to verify the stability and effectiveness of the proposed attenuationcompensated RTM in improving imaging resolution in viscous media.
文摘The research was carried out to establish a new reverse phase-HPLC stability indicating method for quantifying Bimatoprost & Timolol in ophthalmic solution. The experiment of Bimatoprost & Timolol in ophthalmic solution method development was determined on Waters HPLC instrument using a UV Detector. The separation was done by using L11, Zorbex SB phenyl (4.6 mm × 250 mm internal diameter) 5 μm analytical column, containing mobile phase of Phosphate buffer (0.02 M), methanol, and acetonitrile [50:30:20 % v/v]. The method was run at 1 ml·min<sup>-1</sup> at 210 nm for Bimatoprost and 295 nm for Timolol for detection. The drug was eluted at 10.81 min for Bimatoprost and 3.77 min for Timolol. After developing the method, it was assured for the intended use by validation, which was done according to ICH Q2B guidelines. The analytical parameters checked were Specificity/Selectivity, linearity, Range, accuracy, ruggedness, and robustness. It was observed that the response of the detector was linear in the range of 6 - 18 μg/ml with a correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability-indicating assay method was established by using the samples generated by the forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative, and photolytic degradation, and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the quantitative analysis of Bimatoprost 0.3% + Timolol 0.5% Ophthalmic Solution drugs for pharmaceutical use. Currently, there is no official method for Bimatoprost & Timolol combination products in USP or BP. Available research work related to single Bimatoprost or Timolol products was not suitable for testing Bimatoprost and Timolol combination drugs. Additionally, there is no stability-indicating method to test Bimatoprost & Timolol combination products which insist us to do research and develop a new reverse phase-HPLC indicating method which will be faster and more accurate.