期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Effect of bolt rib spacing on load transfer mechanism 被引量:4
1
作者 Wu Tao Cao Chen +1 位作者 Han Jun Ren Ting 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2017年第3期431-434,共4页
Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experime... Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experimental study to confirm that bolt rib internal length has great influence on bolting effect. Pull-out tests were conducted using rebar bolt with different rib spacings of 12, 24, 36 and 48 mm representatively from steel tube and from concrete. Results show that peak load increases 25.3% for bolt with large rib spacing. For pull out using concrete block, the increment of peak load between large and small rib spacing is not significant, but the bolt with large rib spacing has great absorption of deformational energy than small rib spacing bolt. This study provides experimental evidence towards optimum design of rock bolt for understand coal mining industry. 展开更多
关键词 Fully grouted bolt Profile study rib spacing Pullout from concrete
下载PDF
Experimental research on bond strength of deformed GFRP rebars with different surface configurations 被引量:2
2
作者 郝庆多 王言磊 欧进萍 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第4期469-474,共6页
Based on the Canadian Standards Association(CSA) criterion,experiments on 30 pull-out specimens were conducted to study the bond strength of deformed GFRP rebars with 8 different surface configurations.Each rebar was ... Based on the Canadian Standards Association(CSA) criterion,experiments on 30 pull-out specimens were conducted to study the bond strength of deformed GFRP rebars with 8 different surface configurations.Each rebar was embedded in a 150 mm concrete cube,and the test embedded length was four times of the rebar diameter.Relationship between the mode of failure,the average bond strength and the average bond strength-slip for each rebar was analyzed.Results show that the failure mode of all specimens is the shearing off or desquamation of ribs,no splitting cracks appear on the cube specimens.The bond stress of deformed GFRP rebars mainly depends on the mechanical interaction between the ribs of the bar and the surrounding concrete,and the bond strength of deformed GFRP rebars is improved obviously.The optimal rib spacing is less than 2.5 times of the rebar diameter,and the rib height is more than 3% of the rebar diameter. 展开更多
关键词 deformed GFRP rebars concrete bond strength pull-out test rib spacing rib height optimalsurface configuration
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部