Twenty-four New Zealand white rabbits were plated on their intact left tibiae with stainless steel plates and 4 animals served as controls. The plates were removed 2 months after implantation in 20 plated animals. Of ...Twenty-four New Zealand white rabbits were plated on their intact left tibiae with stainless steel plates and 4 animals served as controls. The plates were removed 2 months after implantation in 20 plated animals. Of them, 4 were sacrificed immediately after plate removal and the other 16 were killed in successive groups with 4 in each group 1,2,3 and 4 months after plate removal respectively. The remaining 4 plated animals were killed at 6 months after implantation. Bone samples under the plates were harvested and prepared for polarized light microscopy to investigate the repair of the regional osteoporosis induced by rigid implant. The results indicated that the regional osteoporosis could recover gradually after plate removal. The repair process manifested itself mainly as the repair of resorption cavities and the remodeling of collagen fibers. The orientation of the collagen fibers remained disorganized when the resorption cavities had been repaired. It is suggested that delayed restoration of bone structure might be one of the potential causes of refracture after removal of the rigid implant.展开更多
Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This wo...Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data. Methods: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle. Results: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar. Conclusion: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively.展开更多
文摘Twenty-four New Zealand white rabbits were plated on their intact left tibiae with stainless steel plates and 4 animals served as controls. The plates were removed 2 months after implantation in 20 plated animals. Of them, 4 were sacrificed immediately after plate removal and the other 16 were killed in successive groups with 4 in each group 1,2,3 and 4 months after plate removal respectively. The remaining 4 plated animals were killed at 6 months after implantation. Bone samples under the plates were harvested and prepared for polarized light microscopy to investigate the repair of the regional osteoporosis induced by rigid implant. The results indicated that the regional osteoporosis could recover gradually after plate removal. The repair process manifested itself mainly as the repair of resorption cavities and the remodeling of collagen fibers. The orientation of the collagen fibers remained disorganized when the resorption cavities had been repaired. It is suggested that delayed restoration of bone structure might be one of the potential causes of refracture after removal of the rigid implant.
基金the Science Research Foundation of Ministry of Health of China (No. WKJ2006-2-003)the Department of Education of Zhejiang Province (No. 20010505) the Science and Technol-ogy Department of Zhejiang Province (No. 2003C30044), China
文摘Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data. Methods: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle. Results: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar. Conclusion: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively.