Conversion factor analysis of self-balanced loading test of cast-in-situ piles based on analogue test method 被引量:3
1
作者 Li Jianhang Li Xiaojuan +2 位作者 Gao Luchao Dai Guoliang Wu Weiguo 《Journal of Southeast University(English Edition)》 EI CAS 2019年第2期185-190,共6页
Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering case... Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering cases,the effectiveness of the analogue test method is verified by comparing it with the traditional anchor pile method and self-balanced method.Taking the self-balanced test of the bridge pile foundation in the Songhua River as an example,the conversion factor of sandy soil and weathered mudstone are confirmed by the analogue test method.The results show that the conversion factor of sandy soil and weathered mudstone in the Songhua River area should consider the geological conditions and the construction technology,etc.The standard values are relatively conservative.It is suggested that the engineering application should be properly revised.The recommended range of the conversion factor of sandy soil in this area is 0.65 to 0.85,and that of weathered mudstone is 1.0. 展开更多
关键词 cast-in-situ piles self-balanced method analogue test method Mohr-Coulomb strength theory conversion factor
下载PDF
A Reliable Method of Pile Load Test on Cast-in-Situ Pile Group of Existing Building for Retrofitting
2
作者 Upal Mohammad Towfiqul Quadir 《Journal of Civil Engineering and Architecture》 2014年第7期881-887,共7页
Following the foundation failure of a building, with an aim of economical solution to strengthen other existing buildings of the same project, a new arrangement was implemented experimentally to test the adequacy of l... Following the foundation failure of a building, with an aim of economical solution to strengthen other existing buildings of the same project, a new arrangement was implemented experimentally to test the adequacy of load bearing capacity of a few selected cast-in-situ RCC (reinforced cement concrete) pile groups without demolishing the existing buildings. In this test, the column bottom of an existing building was removed by the help of scaffolding and after that a frame system consisting tension piles and hollow beam was constructed over the pile cap of the to be tested pile group. The load was tested by the help of hydraulic jack system and the constructed frame system. This paper contains the detailed plan, arrangement and method of the test with illustrations. The deflection and loading data analysis is also included which was performed to determine the outcome of the test. Through this test method the appropriate assessment of capacity of pile group of existing building could be done successfully and in result the structure could be saved by only super structure retrofitting. 展开更多
关键词 cast-in-situ pile load test load bearing capacity retrofitting.
下载PDF
ON THE DRIVING BEHAVIOR,VARIABLE-DIAMETEREFFECT AND BEAKING CAPACITY OF DRIVENCAST-IN-SITU PILE WITHFLAT
3
作者 Shi Peidong , Fu Zhenqiu , Zhan Xiaoying Zhejing Academy of Building Research, Hangzhou 3100l2, China Zia Jinzhang Tongji University, Shanghai 200092 , China 《西部探矿工程》 CAS 1995年第5期66-71,共6页
ONTHEDRIVINGBEHAVIOR,VARIABLE-DIAMETEREFFECTANDBEAKINGCAPACITYOFDKIVENCAST-IN-SITUPILEWITHFLATOVERSIZETIPShi... ONTHEDRIVINGBEHAVIOR,VARIABLE-DIAMETEREFFECTANDBEAKINGCAPACITYOFDKIVENCAST-IN-SITUPILEWITHFLATOVERSIZETIPShiPeidong,FuZhenqiu... 展开更多
关键词 pile TIP flat oversize TIP DRIVEN cast-in-situ pile driving behavior variable-diameter effect bear-ing capacity settlensent