期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Design of Fuzzy Controller for Central Air Conditioner
1
作者 谢娟 耿庆波 《Journal of Beijing Institute of Technology》 EI CAS 2003年第S1期20-24,共5页
A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to d... A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to discuss the design of fuzzy controller using common microprogrammed control unit (MCU) in detail. Based on fuzzy theory the query control tables fixed in read only memory (ROM) of MCU are established to realize the energy saving in the room temperature controller and the reasoning procedure is analyzed. The diagram of hardware design and the flow chart of software of room temperature controller are presented. The results show that the proposed method is practical and effective to achieve the energy saving goal. 展开更多
关键词 central air conditioning system room temperature controller fuzzy control energy saving
下载PDF
Room temperature and humidity decoupling control of common variable air volume air-conditioning system based on bilinear characteristics
2
作者 Yuan Zhang Tian Yan +2 位作者 Xinhua Xu Jiajia Gao Gongsheng Huang 《Energy and Built Environment》 2023年第3期354-367,共14页
Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single co... Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single coil VAV AC system,conventional proportional-integral(PI)control algorithm is usually adopted to track the set-points of the room temperature and humidity by regulating the supply air flow rate and the chilled water flow rate,respectively.However,the control performance is usually not good due to the high coupling of the heat and mass transfer in the air-handling unit(AHU).A model-based control method is developed to realize the decoupling control of the room temperature and humidity according to the bilinear characteristics of the temperature and humidity variation.In this control method,a bilinear room temperature controller is used to track the room temperature set-point based on the real-time cooling load,while a room humidity controller is used to track the room humidity set-point depending on the real-time humidity load.The control performance was validated in a simulated VAV AC system.The test results show that comparing with the conventional PI control,the room temperature and humidity are controlled much more robustly and accurately by using the proposed model-based control method. 展开更多
关键词 VAV air-conditioning system room temperature control room humidity control Bilinear control Model-based cascade control
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部