The soft fault induced by parameter variation is one of the most challenging problems in the domain of fault diagnosis for analog circuits.A new fault location and parameter prediction approach for soft-faults diagnos...The soft fault induced by parameter variation is one of the most challenging problems in the domain of fault diagnosis for analog circuits.A new fault location and parameter prediction approach for soft-faults diagnosis in analog circuits is presented in this paper.The proposed method extracts the original signals from the output terminals of the circuits under test(CUT) by a data acquisition board.Firstly,the phase deviation value between fault-free and faulty conditions is obtained by fitting the sampling sequence with a sine curve.Secondly,the sampling sequence is organized into a square matrix and the spectral radius of this matrix is obtained.Thirdly,the smallest error of the spectral radius and the corresponding component value are obtained through comparing the spectral radius and phase deviation value with the trend curves of them,respectively,which are calculated from the simulation data.Finally,the fault location is completed by using the smallest error,and the corresponding component value is the parameter identification result.Both simulated and experimental results show the effectiveness of the proposed approach.It is particularly suitable for the fault location and parameter identification for analog integrated circuits.展开更多
It is the basic research subject that analyzes and calculate the law and numerical value of phase change and gas deviation coefficient of natural gas with high-CO<sub>2</sub> content in the process of safe...It is the basic research subject that analyzes and calculate the law and numerical value of phase change and gas deviation coefficient of natural gas with high-CO<sub>2</sub> content in the process of safe and effective development of gas reservoirs, which is obtained by high-pressure physical properties PVT (Pressure-Volume-Temperature) experiments and different calculation methods calculations. Aiming at natural gas with high-CO<sub>2</sub> content in the Dongfang gas field, the phase change characteristics and physical parameters of different PVT samples are simulated and tested by Chandler 3000-GL analyzer and PVT SIM software. The experimental data shows that the phase state of natural gas with different content of CO<sub>2</sub> has not changed in the study range. At the same time, the deviation coefficient calculated by different calculation methods (DPR, DAK, BB, HY, Gopal) are compared with the experimental data, and the applicable scope of different calculation methods are obtained. The results show that the improved Gopal has high accuracy and is suitable for the calculation of the deviation coefficient of natural gas with high-CO<sub>2</sub> content under high temperature and high pressure in the Dongfang gas field.展开更多
The performance of vehicle suspension is evaluated based on three conflicting indexes:body acceleration,suspension deflection,and dynamic tire load,which vary across different frequency bands.The suspension control st...The performance of vehicle suspension is evaluated based on three conflicting indexes:body acceleration,suspension deflection,and dynamic tire load,which vary across different frequency bands.The suspension control strategy faces the challenge to strike a balance among these indexes.This research analyzes the fundamental mechanism of control phase deviation effects on skyhook damper control,groundhook damper control,and acceleration drive damper control.From the perspective of complex domain mechanical impedance with the support of the inertial suspension,a structure-based compensation approach is proposed to address for the control phase deviation.The simulation analysis demonstrates that the coordination of inertial suspension structure and control strategy can effectively enhance the comprehensive suspension performance across entire frequency range.Finally,a semi-active inertial suspension bench is implemented.The experimental results indicate that the suspension with the semi-active inertial suspension has outstanding vibration isolation ability,and enhances the suspension performance at ride comfort,suspension deflection,and road friendly significantly.展开更多
Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),w...Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),which may deteriorate application performance based on PMUs.To address that,this paper proposes two robust methods of correcting time-varying PAD deviation with unknown parameters of TL(ParTL).First,the phenomena of time-varying PAD deviation observed from field PMU data are presented.Two general formulations for PAD estimation are then established.To simplify the formulations,estimation of PADs is converted into the optimal problem with a single ParTL as the variable,yielding a linear estimation of PADs.The latter is used by second-order Taylor series expansion to estimate PADs accurately.To reduce the impact of possible abnormal amplitude data in field data,the IGG(Institute of Geodesy&Geophysics,Chinese Academy of Sciences)weighting function is adopted.Results using both simulated and field data verify the effectiveness and robustness of the proposed methods.展开更多
为了精确地反映死区时间对双有源桥式变换器(dual active bridge,DAB)移相角偏移与传输功率的影响,将缓冲电容的作用引入到DAB死区效应的分析中。通过设定最优死区时间将电感电流过零点排除在死区时段之外,降低了不同电压模式下死区过...为了精确地反映死区时间对双有源桥式变换器(dual active bridge,DAB)移相角偏移与传输功率的影响,将缓冲电容的作用引入到DAB死区效应的分析中。通过设定最优死区时间将电感电流过零点排除在死区时段之外,降低了不同电压模式下死区过程分析的难度,并得到一个更精确的DAB移相角与传输功率的模型。结果表明:应用该模型能够准确地计算出DAB任意工况下的静态工作点,从而提高DAB小信号建模的精度。展开更多
基金supported by the National Natural Science Foundation of China under Grant No.61371049
文摘The soft fault induced by parameter variation is one of the most challenging problems in the domain of fault diagnosis for analog circuits.A new fault location and parameter prediction approach for soft-faults diagnosis in analog circuits is presented in this paper.The proposed method extracts the original signals from the output terminals of the circuits under test(CUT) by a data acquisition board.Firstly,the phase deviation value between fault-free and faulty conditions is obtained by fitting the sampling sequence with a sine curve.Secondly,the sampling sequence is organized into a square matrix and the spectral radius of this matrix is obtained.Thirdly,the smallest error of the spectral radius and the corresponding component value are obtained through comparing the spectral radius and phase deviation value with the trend curves of them,respectively,which are calculated from the simulation data.Finally,the fault location is completed by using the smallest error,and the corresponding component value is the parameter identification result.Both simulated and experimental results show the effectiveness of the proposed approach.It is particularly suitable for the fault location and parameter identification for analog integrated circuits.
文摘It is the basic research subject that analyzes and calculate the law and numerical value of phase change and gas deviation coefficient of natural gas with high-CO<sub>2</sub> content in the process of safe and effective development of gas reservoirs, which is obtained by high-pressure physical properties PVT (Pressure-Volume-Temperature) experiments and different calculation methods calculations. Aiming at natural gas with high-CO<sub>2</sub> content in the Dongfang gas field, the phase change characteristics and physical parameters of different PVT samples are simulated and tested by Chandler 3000-GL analyzer and PVT SIM software. The experimental data shows that the phase state of natural gas with different content of CO<sub>2</sub> has not changed in the study range. At the same time, the deviation coefficient calculated by different calculation methods (DPR, DAK, BB, HY, Gopal) are compared with the experimental data, and the applicable scope of different calculation methods are obtained. The results show that the improved Gopal has high accuracy and is suitable for the calculation of the deviation coefficient of natural gas with high-CO<sub>2</sub> content under high temperature and high pressure in the Dongfang gas field.
基金supported by the National Natural Science Foundation of China(Grant No.52202471)the National Natural Science Foundation of China:Regional Innovation and Development Joint Fund(Grant No.U20A20331)+2 种基金Jiangsu Funding Program for Excellent Postdoctoral Talent(Grant No.2022ZB659)the National Natural Science Foundation of China(Grant No.52002156 and 52072157)the Postgraduate Education Reform Project of Jiangsu Province(Grant No.KYCX21_3333).
文摘The performance of vehicle suspension is evaluated based on three conflicting indexes:body acceleration,suspension deflection,and dynamic tire load,which vary across different frequency bands.The suspension control strategy faces the challenge to strike a balance among these indexes.This research analyzes the fundamental mechanism of control phase deviation effects on skyhook damper control,groundhook damper control,and acceleration drive damper control.From the perspective of complex domain mechanical impedance with the support of the inertial suspension,a structure-based compensation approach is proposed to address for the control phase deviation.The simulation analysis demonstrates that the coordination of inertial suspension structure and control strategy can effectively enhance the comprehensive suspension performance across entire frequency range.Finally,a semi-active inertial suspension bench is implemented.The experimental results indicate that the suspension with the semi-active inertial suspension has outstanding vibration isolation ability,and enhances the suspension performance at ride comfort,suspension deflection,and road friendly significantly.
基金This work was supported by the National Key Research and Development Program of China(2017YFB0902901)National Natural Science Foundation of China(51627811).
文摘Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),which may deteriorate application performance based on PMUs.To address that,this paper proposes two robust methods of correcting time-varying PAD deviation with unknown parameters of TL(ParTL).First,the phenomena of time-varying PAD deviation observed from field PMU data are presented.Two general formulations for PAD estimation are then established.To simplify the formulations,estimation of PADs is converted into the optimal problem with a single ParTL as the variable,yielding a linear estimation of PADs.The latter is used by second-order Taylor series expansion to estimate PADs accurately.To reduce the impact of possible abnormal amplitude data in field data,the IGG(Institute of Geodesy&Geophysics,Chinese Academy of Sciences)weighting function is adopted.Results using both simulated and field data verify the effectiveness and robustness of the proposed methods.
文摘为了精确地反映死区时间对双有源桥式变换器(dual active bridge,DAB)移相角偏移与传输功率的影响,将缓冲电容的作用引入到DAB死区效应的分析中。通过设定最优死区时间将电感电流过零点排除在死区时段之外,降低了不同电压模式下死区过程分析的难度,并得到一个更精确的DAB移相角与传输功率的模型。结果表明:应用该模型能够准确地计算出DAB任意工况下的静态工作点,从而提高DAB小信号建模的精度。