Space-time Resolved Spectroscopic System Based on a Rotating Hexahedral Mirror for Measurement of Visible and Ultraviolet Spectral Line Emissions 被引量:1
1
作者 吴振伟 万宝年 +1 位作者 周倩 黄娟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第4期2915-2918,共4页
By using a rotating hexahedral mirror placed in front of the objective lens and two sets of visible and ultraviolet monochromators coupled with a branchy quartz fiber bundle, a space-time resolved spectroscopic system... By using a rotating hexahedral mirror placed in front of the objective lens and two sets of visible and ultraviolet monochromators coupled with a branchy quartz fiber bundle, a space-time resolved spectroscopic system has been developed on the HT-7 superconducting tokamak. A center monitoring system has been used including a Helium-Neon laser and a photodiode detector to indicate the absolute position of the measurement in order to reduce the error caused by the uncertain emissive position of the plasma. By using the asymmetric Abel inversion, the space-time resolved local emission coefficients of the spectroscopic line emissions have been obtained. Presented in this article are simultaneous measurements of two spectral line emissions such as CV-227.1 nm and OV-278.1 nm during a single plasma discharge on the HT-7. Experimental results indicate that the time resolution is better than 3 ms, the space resolution is better than 1.5cm, the ratio of signal to background is better than 10:1, and the relative error of chord-integrated emission profile is less than 10%. Compared to traditional multichannel detecting systems, this system has considerably improved measurement efficiency, reduced uncertainty, and is therefore suitable for transport studies of global particles and impurities. 展开更多
关键词 space-time resolved rotating mirror SPECTROSCOPIC IMPURITY TOKAMAK
下载PDF
Diode Pumped High Peak Power Quasi Q-Switched and Passively Q-Switched Nd:YVO<sub>4</sub>Lasers at 1064 nm and 532 nm using Cr:YAG and KTP crystals
2
作者 Ashraf F. El-Sherif Mahmoud M. Talat 《Optics and Photonics Journal》 2013年第1期51-62,共12页
Diode end-pumped solid-state lasers have the potential to yield high quality laser beams with high efficiency for laser range finding and warning receiver applications as well as day and night military laser designati... Diode end-pumped solid-state lasers have the potential to yield high quality laser beams with high efficiency for laser range finding and warning receiver applications as well as day and night military laser designation systems. In this paper we presents theoretical calculations using Advanced Dynamics Professional LASCAD software and experimental studies for a high power pigtailed fiber diode laser module of 8 W operating at 808 nm with a specially designed high efficiency cooling system, end pumped high-efficiency Nd:YVO4 laser of 3 × 3 × 10 mm rod and overall cavity length of 44 mm. To the best of our knowledge a self Q-switching effects was generated in Nd:YVO4 laser by changing the cavity dimensions and the position of the intracavity KTP crystal at certain regime of operation for the first time, in which the cavity length is reduced to be 30 mm and the distance between Nd:YVO4 rod and KTP crystal is only 1mm. Self Q-switched laser pulse at 532 nm with high peak power of 96 W, pulse width of 88 ns at FWHM and repetition rate of 400 kHz was achieved. Experimental studies of a passive Q-switched Nd:YVO4 laser using Cr:YAG crystal with three different transmissions of 30%, 40% and 70% were investigated. Passive Q-switched laser pulse at 1064 nm and narrow line width of less than 1.5 nm with highest peak power of nearly 18 kW, short pulse width of less than 4 ns at FWHM and higher repetition rate of 45 kHz using Cr:YAG with transmission of 30% was achieved for the first time. 展开更多
关键词 High POWER Diode LASER High POWER Nd:YVO4 LASER CR:YAG Saturable Absorber mirror Passive q-switchING KTP Crystal Self q-switchING Special Cooling System
下载PDF
2.79μm高速转镜调Q Er,Cr:YSGG纳秒窄脉冲激光器
3
作者 朱永斌 马圣洁 +3 位作者 程庭清 王礼 陈月明 江海河 《光学精密工程》 EI CAS CSCD 北大核心 2024年第8期1122-1129,共8页
转镜调Q无插入损耗,是获得窄脉冲、高峰值功率输出激光的直接方式。纳秒脉冲需要使用高速转镜调Q,并精准控制电机转速与氙灯放电延时,以使激光介质上能级粒子数反转最大,获得最大激光能量输出。本文设计了以Arduino mega 2560单片机为... 转镜调Q无插入损耗,是获得窄脉冲、高峰值功率输出激光的直接方式。纳秒脉冲需要使用高速转镜调Q,并精准控制电机转速与氙灯放电延时,以使激光介质上能级粒子数反转最大,获得最大激光能量输出。本文设计了以Arduino mega 2560单片机为核心的高速转镜调Q控制系统,通过精确单片机解析串口屏指令控制激光电源的充放电和高速电机启停,同时通过对转镜脉冲信号整合降频控制氙灯放电时刻,实现对延迟时间的精准控制,实现了灯泵Er,Cr:YSGG激光纳秒窄脉冲调Q输出。在5 Hz重复频率下,转镜转速为650 r/s时,获得的最高单脉冲激光能量为45.7 mJ、脉冲宽度为86.2 ns,相应的峰值功率为530.2 kW。 展开更多
关键词 转镜调Q 固体激光器 ER Cr:YSGG激光 ARDUINO 氙灯泵浦
下载PDF
30m望远镜的三镜Rotator组件轴承概念设计 被引量:6
4
作者 苏燕芹 张景旭 +2 位作者 杨飞 王槐 陈宝刚 《光学精密工程》 EI CAS CSCD 北大核心 2013年第6期1510-1517,共8页
针对美国30m望远镜(TMT)三镜系统在工作时的特殊要求,对三镜系统的Rotator组件轴承进行了设计,提出了在载荷连续变化条件下轴系的设计方法。通过分析该系统独特的运动和受力方式并对比现有大型望远镜结构形式,确定了三排滚柱支撑的轴系... 针对美国30m望远镜(TMT)三镜系统在工作时的特殊要求,对三镜系统的Rotator组件轴承进行了设计,提出了在载荷连续变化条件下轴系的设计方法。通过分析该系统独特的运动和受力方式并对比现有大型望远镜结构形式,确定了三排滚柱支撑的轴系方案及轴承结构参数。计算中将天顶角定义为变量,确定了轴承的最恶劣工况及此时的望远镜指向。采用了数值计算和有限元仿真的方法对这一条件下的轴承变形和应力同时进行校核,两种方法得到的结果符合得很好,证明了模型的正确性。结果表明,天顶角为0°~65°时,轴承在x、y、z方向上的变形不超过0.015mm,轴承倾角不超过1.7×10-5 rad,满足设计要求,并留有很大裕度。 展开更多
关键词 30m望远镜 三镜系统 轴承 三排滚柱 有限元法
下载PDF
一种大口径平面镜支撑结构的仿真与实验
5
作者 王全全 王彦钧 +1 位作者 韩森 徐春凤 《软件导刊》 2024年第3期55-61,共7页
为提高600 mm大口径立式平面镜沿光轴旋转90°后的表面面型测量精度,对多孔支撑结构下5种不同材料的平面镜重力变形进行有限元仿真分析,并通过实验测量探究旋转后的静置时间对面型精度的影响等问题。结果表明,该多孔支撑结构下的平... 为提高600 mm大口径立式平面镜沿光轴旋转90°后的表面面型测量精度,对多孔支撑结构下5种不同材料的平面镜重力变形进行有限元仿真分析,并通过实验测量探究旋转后的静置时间对面型精度的影响等问题。结果表明,该多孔支撑结构下的平面镜表面由重力导致的轴向变形量不超过14 nm,满足精度要求。该多孔结构支撑的平面镜沿光轴旋转90°静置1 h后达到稳定状态,与静置2 h后的面型结果PV值仅相差0.337 nm,RMS值相差0.081 nm,实验探究了静置时间对面型结果的影响。研究发现,在至多去除6%外口径的条件下可以大幅降低平面镜表面面型PV值,PV值降低超过50 nm,由此提出一种制造大口径平面镜时通过设置支撑结构缓冲区以提高面型精度的方法,可以有效提高大口径平面镜的面型精度。 展开更多
关键词 大口径平面镜 有限元仿真 干涉测量 旋转测量 实验验证
下载PDF
Design of fiber-optic collector for spectrometer based on curved mirror 被引量:1
6
作者 ZHUANG Xin-gang WANG Li-li +2 位作者 SHAO Xiu-mei FANG Jia-xiong JIANG Ben-he 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第1期97-102,共6页
To enlarge the detection range of traditional fiber-optic spectrometer,two rotating parabolic mirrors were first used in the design of fiber-optic collector for spectrometer,which can extend the detection range of spe... To enlarge the detection range of traditional fiber-optic spectrometer,two rotating parabolic mirrors were first used in the design of fiber-optic collector for spectrometer,which can extend the detection range of spectrometer from centimeter-scale to50m,as a super-low altitude remote sensing detector under passive lighting conditions.According to the performance requirements of fiber-spectrometer for optical collector,this study deduced the calculation formulae of design size of parabolic optical collector applied to different sensitivity spectrometers,different detection targets,different detection ranges and different weathers.Based on the calculation results,the model of fiber-optic collector with a diameter of16mm and a height of7.8mm was designed by ZEMAX.And then,TracePro,a light simulation software,was applied to ray tracing.The simulation results of optical radiation magnification agrees well with theoretical value,and the relative error is less than0.78%.This optical collector can effectively extend the detection range of spectrometer and expand its application fields and scopes.Compared with traditional refractive optical collector,it has several advantages of compact structure,low weight and low cost. 展开更多
关键词 fiber-optic collector fiber-spectrometer rotating parabolic mirror infrared radiation atmospheric transmission
下载PDF
Passive Q-switching and Q-switched mode-locking operations of 2 μm Tm:CLNGG laser with MoS2 saturable absorber mirror 被引量:17
7
作者 L.C.Kong G.Q.Xie +4 位作者 P.Yuan L.J.Qian S.X.Wang H.H.Yu H.J.Zhang 《Photonics Research》 SCIE EI 2015年第2期47-50,共4页
With MoS2 as saturable absorber, passive Q-switching and Q-switched mode-locking operations of a Tm-doped calcium lithium niobium gallium garnet(Tm:CLNGG) laser were experimentally demonstrated. The Q-switched laser... With MoS2 as saturable absorber, passive Q-switching and Q-switched mode-locking operations of a Tm-doped calcium lithium niobium gallium garnet(Tm:CLNGG) laser were experimentally demonstrated. The Q-switched laser emitted a maximum average output power of 62 mW and highest pulse energy of 0.72 μJ. Q-switched mode locking was also obtained in the experiment. The research results will open up applications of MoS2 at the mid-infrared wavelength. 展开更多
关键词 mode RATE m Tm:CLNGG laser with MoS2 saturable absorber mirror Passive q-switching and q-switched mode-locking operations of 2 TM
原文传递
基于FRM的直升机载光纤惯导用抗振型光源研究
8
作者 张恩康 张红伟 +1 位作者 李雷 步鑫 《电光与控制》 CSCD 北大核心 2023年第4期116-121,共6页
振动性能是评价高精度直升机载光纤陀螺环境可靠性与性能稳定性的一个重要指标,光源作为直升机载光纤惯导的源头部件,需要保证其在振动条件下性能的稳定输出。针对光源平均波长随振动变化的问题,从基本机理出发,通过建立光路琼斯矩阵模... 振动性能是评价高精度直升机载光纤陀螺环境可靠性与性能稳定性的一个重要指标,光源作为直升机载光纤惯导的源头部件,需要保证其在振动条件下性能的稳定输出。针对光源平均波长随振动变化的问题,从基本机理出发,通过建立光路琼斯矩阵模型,深入研究了光纤中传输光的偏振态与偏振相关损耗之间的关系,在不增加光源系统复杂性的情况下提出了一种基于法拉第旋转镜的直升机载光纤惯导用抗振型光源,并实验验证了其抗振动性能。实验表明,提出的方案可以大大提高光源和光纤惯导振动条件下的稳定性,特别是高频振动条件下(1000~2000 Hz),光源的平均波长稳定性提高了6.8×10^(-6)。 展开更多
关键词 光纤陀螺 掺铒光纤光源 抗振型 法拉第旋转镜 平均波长
下载PDF
基于主元分析的对称性检测 被引量:20
9
作者 卢春雨 张长水 +1 位作者 闻芳 阎平凡 《电子学报》 EI CAS CSCD 北大核心 1999年第5期25-28,共4页
对称性在日常生活中广泛存在,对一般物体镜像和旋转对称性的快速检测一直是计算机视觉的难题,至今未有通用性很好且效率较高的算法.本文提出一种新的方法,把对称性检测问题转化为协方差矩阵的特征值分解问题,文中的3个定理及其证... 对称性在日常生活中广泛存在,对一般物体镜像和旋转对称性的快速检测一直是计算机视觉的难题,至今未有通用性很好且效率较高的算法.本文提出一种新的方法,把对称性检测问题转化为协方差矩阵的特征值分解问题,文中的3个定理及其证明奠定了理论基础.此外还把这一结论推广到旋转对称性的检测问题.仿真表明:这种方法理论基础扎实,操作简便,非常适合于强镜像对称复杂图像的镜像对称轴方向检测. 展开更多
关键词 主元分析 镜像 对称检测 旋转 计算机视觉
下载PDF
消除45°旋转扫描反射镜像旋转系统的研究及应用 被引量:26
10
作者 张锷 龚惠兴 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 1999年第2期125-132,共8页
研制了在宽波段范围内采用“K镜”来消除45°旋转扫描反射镜像旋转的系统,并进行了理论上的推导和海洋卫星水色扫描仪的实际应用,证明该系统能很好地消除45°旋转扫描反射镜产生的像旋转,从而提出45°旋转扫描反... 研制了在宽波段范围内采用“K镜”来消除45°旋转扫描反射镜像旋转的系统,并进行了理论上的推导和海洋卫星水色扫描仪的实际应用,证明该系统能很好地消除45°旋转扫描反射镜产生的像旋转,从而提出45°旋转扫描反射镜加“K镜” 展开更多
关键词 45°旋转扫描 反射镜 "K镜" 像旋转
下载PDF
45°二维扫描镜扫描轴系特性分析 被引量:17
11
作者 惠彬 李景镇 +1 位作者 黄虹宾 裴云天 《红外技术》 CSCD 北大核心 2006年第9期508-511,共4页
对工作于三轴稳定平台的45°扫描镜绕不同轴系摆动时的摆动范围及扫描轨迹进行了分析比较,给出了扫描镜选用不同轴系时的扫描摆动角度的计算方法,在工程应用中具有重要实用意义。
关键词 二维扫描镜 45°镜 轴系 扫描轨迹 扫描视场
下载PDF
二维扫描镜扫描特性理论分析 被引量:10
12
作者 惠彬 裴云天 王淦泉 《量子电子学报》 CAS CSCD 北大核心 2005年第5期810-813,共4页
在航天遥感仪器中,为了缩小二维指向镜的大小可将45°镜偏转一定角度,如60°镜。在光学反射矢量理论基础上,对不同角度指向镜的摆动范围、像旋特性进行分析比较。从扫描特性角度分析了倾斜扫描镜使其减小尺寸的可行性。
关键词 遥感 二维指向镜 45°镜 60°镜 像旋角 扫描轨迹
下载PDF
扫描式超高速摄影中转镜镜面变形量的几何补偿 被引量:9
13
作者 黄虹宾 柴金龙 +3 位作者 龚向东 李景镇 孙凤山 何铁锋 《光子学报》 EI CAS CSCD 北大核心 2008年第5期1015-1019,共5页
利用三维有限元计算技术,分析了从三面体到八面体铝合金转镜镜面变形规律.发现以四面体为界,三面体转镜镜面变形为向内凹进,五面体及以上转镜镜面则向外凸出·在对镜面变形定量分析基础上,提出了镜面变形的几何补偿方法,即采用柱面... 利用三维有限元计算技术,分析了从三面体到八面体铝合金转镜镜面变形规律.发现以四面体为界,三面体转镜镜面变形为向内凹进,五面体及以上转镜镜面则向外凸出·在对镜面变形定量分析基础上,提出了镜面变形的几何补偿方法,即采用柱面代替平直镜面,使镜面变形后的位置趋近于平直·结果表明,对镜面尺寸17.32mm,轴向长度32.5mm的三面体铝合金转镜,在5×104rpm下,镜面最高点偏离平直镜面的最大值为0.468μm,是平直镜面的1/9,与相同结构尺寸的铍转镜镜面变形量处于相同量级·说明铝合金转镜采用几何补偿方法,可以在扫描式摄影系统中代替铍转镜· 展开更多
关键词 扫描式超高速摄影 转镜镜面 几何补偿 有限元方法
下载PDF
超高速摄影中蜂窝结构转镜的设计与力学分析 被引量:7
14
作者 黄虹宾 李景镇 +2 位作者 柴金龙 龚向东 孙凤山 《强激光与粒子束》 EI CAS CSCD 北大核心 2008年第3期363-366,共4页
提出了蜂窝结构的三面体转镜,对这种新型转镜做了结构设计,并利用3维有限元计算技术,分析了蜂窝结构的三面体铝合金转镜的力学性能。结果表明:对镜面尺寸17.325 mm、轴向长度32.5 mm的三面体铝合金转镜,在5×104r/min转速下,镜面最... 提出了蜂窝结构的三面体转镜,对这种新型转镜做了结构设计,并利用3维有限元计算技术,分析了蜂窝结构的三面体铝合金转镜的力学性能。结果表明:对镜面尺寸17.325 mm、轴向长度32.5 mm的三面体铝合金转镜,在5×104r/min转速下,镜面最大变形量为0.547μm,约为原结构铝合金转镜镜面的16%,与相同结构尺寸的铍转镜镜面变形量处于相同量级;内部最大应力小于原结构铝合金转镜。 展开更多
关键词 超高速摄影 转镜 蜂窝结构 镜面变形
下载PDF
五棱镜转动时出射光角度的变化 被引量:7
15
作者 袁理 张晓辉 +2 位作者 韩冰 谷立山 张鹰 《中国光学》 EI CAS CSCD 2015年第6期1035-1043,共9页
为了对大口径平面镜面形轮廓的五棱镜扫描法测试进行误差分析和修正,对五棱镜转动时出射光角度的变化进行了分析与精确计算。首先建立了合适的坐标系并规定了角度的正负,然后由入射光的偏摆角和俯仰角计算入射光向量,接着介绍了五棱镜... 为了对大口径平面镜面形轮廓的五棱镜扫描法测试进行误差分析和修正,对五棱镜转动时出射光角度的变化进行了分析与精确计算。首先建立了合适的坐标系并规定了角度的正负,然后由入射光的偏摆角和俯仰角计算入射光向量,接着介绍了五棱镜的作用矩阵与坐标转换矩阵,在此基础上详细分析了五棱镜转动的整个过程并且计算了出射光向量。然后计算出射光的偏摆角和俯仰角,再计算当五棱镜没有转动时出射光的偏摆角和俯仰角。最后计算出射光偏摆角和俯仰角的变化。特别分析了当入射光垂直入射五棱镜的情况。随后进行了实际计算与实验,总结了出射光角度变化的一些规律。将计算数据与实验数据进行了比较,结果最大偏差为1″。最大偏差在实验精度范围内,证明了计算方法是正确的。 展开更多
关键词 平面镜测试 五棱镜 转动 角度变化
下载PDF
偏振无关的Michelson光纤传感器的研究 被引量:14
16
作者 李志能 沈梁 叶险峰 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2002年第1期44-46,共3页
针对低双折射光纤双光束干涉型传感器两臂偏振态随机变化引起的信号衰落 ,介绍了一种新型的干涉型光纤传感器的消偏振衰落技术 .通过在 Michelson光纤干涉仪上加两个法拉第旋转镜以抵消偏振态的随机变化 ,可以使输出信号的可见度稳定为... 针对低双折射光纤双光束干涉型传感器两臂偏振态随机变化引起的信号衰落 ,介绍了一种新型的干涉型光纤传感器的消偏振衰落技术 .通过在 Michelson光纤干涉仪上加两个法拉第旋转镜以抵消偏振态的随机变化 ,可以使输出信号的可见度稳定为 1,并分析了瑞利散射对光纤干涉仪的影响 . 展开更多
关键词 Michelson光纤干涉仪 法拉第旋转镜 光学偏振态 瑞利散射 光纤传感器 偏振衰落
下载PDF
反射转镜式干涉光谱仪光程差非线性修正方法比较 被引量:9
17
作者 景娟娟 周锦松 +2 位作者 相里斌 吕群波 魏儒义 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2010年第6期1678-1682,共5页
介绍了反射转镜式干涉光谱仪的原理。转镜的转动会导致光程差存在非线性问题,是转镜式干涉光谱仪普遍存在的问题。由于光程差的非线性会导致反演光谱的严重失真,因此需要对其进行修正处理。对非线性修正问题,目前常用的有光程差替换法... 介绍了反射转镜式干涉光谱仪的原理。转镜的转动会导致光程差存在非线性问题,是转镜式干涉光谱仪普遍存在的问题。由于光程差的非线性会导致反演光谱的严重失真,因此需要对其进行修正处理。对非线性修正问题,目前常用的有光程差替换法、干涉图二次采样法和NUFFT法。实验结果证明,NUFFT法和光程差替换法运算精度较高,相对偏差优于0.13%,NUFFT法精度又略高于光程差替换法;在运行效率上,NUFFT法运行速度最快,其次为光程差替换法。由于干涉图本身是一个剧变信号(特别是在零光程差附近),不适合进行多项式拟合,所以干涉图二次采样法运算精度最低,另外,由于干涉图二次采样法需要做分段拟合运算,所以运行效率也最低,从而可以认为NUFFT方法是目前最适用于反射转镜式干涉光谱仪非线性采样误差修正的方法。 展开更多
关键词 光谱仪 反射转镜 光程差 非线性采样
下载PDF
转镜式高速相机控制系统 被引量:15
18
作者 吴云峰 叶玉堂 +1 位作者 刘宁文 谭显祥 《仪器仪表学报》 EI CAS CSCD 北大核心 2004年第1期134-137,共4页
由于应用的需求 ,转镜式高速相机的控制系统发展成以计算机和多种专用外围单元组成的计算机控制系统。介绍了该系统的组成和工作原理 ,系统各单元的具体实现方法。该系统采用了计算机控制、电力电子以及冲击电流放电等技术。
关键词 转镜式高速相机 控制系统 光学原理图 计算机
下载PDF
航空相机的像旋转特性分析及其补偿方法 被引量:9
19
作者 王俊善 翟林培 +2 位作者 丁亚林 王晓军 肖占全 《红外与激光工程》 EI CSCD 北大核心 2008年第3期493-496,共4页
航空相机在多航迹成像方式中,随着45°反射镜绕光轴旋转对物进行扫描,物体反射像也将绕光轴进行旋转,为此必须采取消除像旋转的措施来保证成像质量。为阐述产生像旋转的原因,分析了扫描反射镜的像旋转特性;并在探讨消除像旋技术理... 航空相机在多航迹成像方式中,随着45°反射镜绕光轴旋转对物进行扫描,物体反射像也将绕光轴进行旋转,为此必须采取消除像旋转的措施来保证成像质量。为阐述产生像旋转的原因,分析了扫描反射镜的像旋转特性;并在探讨消除像旋技术理论的基础上,提出了一种反射镜与探测器同步转动消除像旋转的方法。在多航迹工作方式中,此方法为相机扫描机构连续扫描成像提供了必要条件。利用此方法还改进了以往步进式扫描机构的惯量大、扫描效率低的问题,并在实际工程中得以应用和证明。试验结果表明,该方法的同步旋转误差小于1/3像元,能够获得良好的图像效果。 展开更多
关键词 航空相机 像旋转 45°扫描反射镜 扫描成像
下载PDF
摆扫式面阵CCD航空相机的像旋转分析 被引量:5
20
作者 郑飞 丁亚林 +2 位作者 吴雪峰 许永森 李娜 《红外与激光工程》 EI CSCD 北大核心 2009年第5期897-900,共4页
航空相机在进行拍照时,通常采用45°扫描反射镜绕光轴摆扫或步进,进行多行迹摆扫式拍照,以增大对地面景物的观测范围,但当扫描镜绕光轴旋转对物体进行观测时,物体反射像也将绕轴进行旋转,目标相对探测器(CCD)产生了像旋转。通过运... 航空相机在进行拍照时,通常采用45°扫描反射镜绕光轴摆扫或步进,进行多行迹摆扫式拍照,以增大对地面景物的观测范围,但当扫描镜绕光轴旋转对物体进行观测时,物体反射像也将绕轴进行旋转,目标相对探测器(CCD)产生了像旋转。通过运用光线矢量与光轴旋转变换的方法,建立了相机的数学模型。根据该模型,针对扫描反射镜旋转所产生的像旋转,利用光学矩阵建立了扫描镜转角与像旋转角之间的关系,对比各种消除像旋方法的优缺点,提出了采用扫描镜与像面旋转机构同步旋转结合的方法实现消除像旋,为工程设计提供了必要参考。 展开更多
关键词 45°扫描反射镜 像旋 航空相机
下载PDF