BACKGROUND Neuropathy is a common complication of diabetes mellitus resulting from direct damage by hyperglycemia to the nerves and/or ischemia by microvascular injury to the endoneurial vessels which supply the nerve...BACKGROUND Neuropathy is a common complication of diabetes mellitus resulting from direct damage by hyperglycemia to the nerves and/or ischemia by microvascular injury to the endoneurial vessels which supply the nerves. Median nerve is one of the peripheral nerves commonly affected in diabetic neuropathy. The median nerve size has been studied in non-Nigerian diabetic populations. In attempt to contribute to existing literature, a study in a Nigerian population is needed.AIM To evaluate the cross-sectional area(CSA) of the median nerve using B-mode ultrasonography(USS) and the presence of peripheral neuropathy(PN) in a cohort of adult diabetic Nigerians.METHODS Demographic and anthropometric data of 85 adult diabetes mellitus(DM) and 85 age-and sex-matched apparently healthy control(HC) subjects were taken. A complete physical examination was performed on all study subjects to determine the presence of PN and modified Michigan Neuropathy Screening Instrument(MNSI) was used to grade its severity. Venous blood was taken from the study subjects for fasting lipid profile(FLP), fasting blood glucose(FBG) and glycated haemoglobin(HbA1 c) while their MN CSA was evaluated at a point 5 cm proximal to(5 cmCATL) and at the carpal tunnel(CATL) by high-resolution Bmode USS. Data was analysed using SPSS version 22.RESULTS The mean MN CSA was significantly thicker in DM subjects compared to the HC at 5 cmCATL(P < 0.01) and at the CATL(P < 0.01) on both sides. The presence of diabetic peripheral neuropathy(DPN) further increased the MN CSA at the CATL(P < 0.05) but not at 5 cmCATL(P > 0.05). However, the severity of DPN had no additional effect on MN CSA 5 cm proximal to and at the CATL. There was no significant association between MN CSA and duration of DM and glycemic control.CONCLUSION Thickening of the MN CSA at 5 cmCATL and CATL is seen in DM. Presence of DPN is associated with worse thickening of the MN CSA at the CATL but not at5 cmCATL. Severity of DPN, duration of DM, and glycemic control had no additional effect on the MN CSA.展开更多
High-resolution ultrasonography was used to analyze the nerve cross-sectional area (CSA) of the median nerve at 7 sites: the wrist crease, pisiform bone, hamate bone, 6 cm proximal to the tip of the wrist crease, p...High-resolution ultrasonography was used to analyze the nerve cross-sectional area (CSA) of the median nerve at 7 sites: the wrist crease, pisiform bone, hamate bone, 6 cm proximal to the tip of the wrist crease, proximal forearm (where the nerve enters the pronator teres muscle), 4 cm proximal to the tip of the medial epicondyle, and mid-humerus (mid-point between elbow crease and axilla) in 200 healthy volunteers from Guiyang, China. Results showed similar CSA values between the left and right sides, but the CSA 6 cm proximal to the tip of the wrist crease, proximal forearm, 4 cm proximal to tip of the medial epicondyle, and mid-humerus in males was greater than that of females. Moreover, CSA values at the wrist crease, pisiform bone, and hamate bone were greater in the middle-aged and old groups when compared to the young group, and correlated with body mass and height. Thus, reference values of median nerve CSA of the upper limbs can facilitate the analysis of abnormal nerve conditions.展开更多
Rotating packed bed(RPB) is one of the most effective gas–liquid mass transfer enhancement reactors, its effective specific mass transfer area(ae) is critical to understand the mass transfer process. By using the NaO...Rotating packed bed(RPB) is one of the most effective gas–liquid mass transfer enhancement reactors, its effective specific mass transfer area(ae) is critical to understand the mass transfer process. By using the NaOH–CO_(2) chemical absorption method, the aevalues of three RPB reactors with different rotor sizes were measured under different operation conditions. The results showed that the high gravity factor and liquid flow rate were major affecting factors, while the gas flow rate exhibited minor influence.The radius of packing is the dominant equipment factor to affect aevalue. The results indicated that the contact area depends on the dispersion of the liquid phase, thus the centrifugal force of rotating packed bed greatly influenced the aevalue. Moreover, the measured ae/ap(effective specific mass transfer area/specific surface area of packing) values were fitted with dimensionless correlation formulas. The unified correlation formula with dimensionless bed size parameter can well predict the experimental data and the prediction errors were within 15%.展开更多
Although ultrasound measurements have been used in previous studies on carpal tunnel syndrome to visualize injury to the median nerve, whether such ultrasound data can indicate the severity of carpal tunnel syndrome r...Although ultrasound measurements have been used in previous studies on carpal tunnel syndrome to visualize injury to the median nerve, whether such ultrasound data can indicate the severity of carpal tunnel syndrome remains controversial. The cross-sectional areas of the median nerve at the tunnel inlet and outlet can show swelling and compression of the nerve at the carpal. We hypothesized that the ratio of the cross-sectional areas of the median nerve at the carpal tunnel inlet to outlet accurately reflects the severity of carpal tunnel syndrome. To test this, high-resolution ultrasound with a linear array transducer at 5–17 MHz was used to assess 77 patients with carpal tunnel syndrome. The results showed that the cut-off point for the inlet-to-outlet ratio was 1.14. Significant differences in the inlet-to-outlet ratio were found among patients with mild, moderate, and severe carpal tunnel syndrome. The cut-off point in the ratio of cross-sectional areas of the median nerve was 1.29 between mild and more severe(moderate and severe) carpal tunnel syndrome patients with 64.7% sensitivity and 72.7% specificity. The cut-off point in the ratio of cross-sectional areas of the median nerve was 1.52 between the moderate and severe carpal tunnel syndrome patients with 80.0% sensitivity and 64.7% specificity. These results suggest that the inlet-to-outlet ratio reflected the severity of carpal tunnel syndrome.展开更多
BACKGROUND Acromioclavicular joint(ACJ)space narrowing has been considered to be an important diagnostic image parameter of ACJ osteoarthritis(ACJO).However,the morphology of the ACJ space is irregular because of oste...BACKGROUND Acromioclavicular joint(ACJ)space narrowing has been considered to be an important diagnostic image parameter of ACJ osteoarthritis(ACJO).However,the morphology of the ACJ space is irregular because of osteophyte formation,subchondral irregularity,capsular distention,sclerosis,and erosion.Therefore,we created the ACJ cross-sectional area(ACJCSA)as a new diagnostic image parameter to assess the irregular morphologic changes of the ACJ.AIM To hypothesize that the ACJCSA is a new diagnostic image parameter for ACJO.METHODS ACJ samples were obtained from 35 patients with ACJO and 30 healthy individuals who underwent shoulder magnetic resonance(S-MR)imaging that revealed no evidence of ACJO.Oblique coronal,T2-weighted,fat-suppressed SMR images were acquired at the ACJ level from the two groups.We measured the ACJCSA and the ACJ space width(ACJSW)at the ACJ on the S-MR images using our imaging analysis program.The ACJCSA was measured as the cross-sectional area of the ACJ.The ACJSW was measured as the narrowest point between the acromion and the clavicle.RESULTS The average ACJCSA was 39.88±10.60 mm;in the normal group and 18.80±5.13 mm;in the ACJO group.The mean ACJSW was 3.51±0.58 mm in the normal group and 2.02±0.48 mm in the ACJO group.ACJO individuals had significantly lower ACJCSA and ACJSW than the healthy individuals.Receiver operating characteristic curve analyses demonstrated that the most suitable ACJCSA cutoff score was 26.14 mm^(2),with 91.4%sensitivity and 90.0%specificity.CONCLUSION The optimal ACJSW cutoff score was 2.37 mm,with 88.6%sensitivity and 96.7%specificity.Even though both the ACJCSA and ACJSW were significantly associated with ACJO,the ACJCSA was a more sensitive diagnostic image parameter.展开更多
Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to desc...Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to describe the ideal correlation between the current ratio(y)and the cross-sectional area ratio(x)of the dual electrodes,where k is the filling ratio.Investigation was conducted on the electroslag casting process with dual electrodes of various cross-sectional areas,but at a constant k value.The experimental results indicated that the ideal correlation was obtained at the stable casting stage,and the fitting results were consistent with the experimental results at certain k values.The experimental findings show that better castings can be obtained when the current ratio is greater than 1.536 and the cross-sectional area ratio is greater than 0.5.展开更多
By tilting a plasma jet and rotating 360°,a large-area can be scanned and sterilized in a short time.Compared with the previous array device,this pipe has the significant advantages of high sterilization uniformi...By tilting a plasma jet and rotating 360°,a large-area can be scanned and sterilized in a short time.Compared with the previous array device,this pipe has the significant advantages of high sterilization uniformity and low gas consumption.Firstly,a rotatable plasma jet device,which can control the swing and rotation of a jet pipe,is designed,and a corresponding theoretical model is established to guide the experiment.Secondly,with Staphylococcus aureus(S.aureus)and Escherichia coli(E.coli)as the target bacteria,the device achieves a short sterilization time of 158 s—the minimum sterilization flow of S.aureus and E.coli is 0.8 slm and 0.6 slm,respectively.The device is compared with an array plasma sterilization device in terms of sterilization speed and gas consumption.The results show that the device is not only better than an array plasma sterilization device with respect to scanning uniformity,but also far less than the array plasma sterilization device in gas consumption of 5 slm.Therefore,the device has great potential in applications involving efficient,large-area sterilization.展开更多
机场飞行区现使用的场面监视方法存在着定位偏差较大、不稳定、易跳变、皆为点源定位等问题。针对这些问题,设计了基于视觉图像的飞行区监视方法,实现快速准确的目标检测和轮廓定位,使飞行区监视更加稳定精确。提出了一种基于MobileNetV...机场飞行区现使用的场面监视方法存在着定位偏差较大、不稳定、易跳变、皆为点源定位等问题。针对这些问题,设计了基于视觉图像的飞行区监视方法,实现快速准确的目标检测和轮廓定位,使飞行区监视更加稳定精确。提出了一种基于MobileNetV3和YOLOv5的网络模型(以下称为MobileNetV3-YOLOv5),即在YOLOv5的主干中使用MobileNetV3,来提高对目标的检测速度和准确度;提出了一种基于优化特征点提取的改进定向快速旋转简报(Oriented FAST and Rotated BRIEF,ORB)算法,将图像分割成多个区域,分别提取每个区域的特征点,从而提高目标识别框内区域的特征点识别数量,再进行特征点聚类筛选,最后根据识别目标类型采用最小包围盒进行轮廓划分,得到目标的轮廓定位。试验结果表明:MobileNetV3-YOLOv5方法对比原始YOLOv5模型,在识别目标准确率方面提升5百分点,在效率方面提升14张/s;同时在0~60 m的范围内,轮廓估计误差仅为2.9%;体现了所提出的监视方法的有效性,可以提升飞行区监视定位准确性和运行安全性。展开更多
This paper models the giraffe’s jugular veins as a uniform collapsible tube from a rigid skull. The equations governing one-dimensional steady flow through such a tube for various conditions have been developed. The ...This paper models the giraffe’s jugular veins as a uniform collapsible tube from a rigid skull. The equations governing one-dimensional steady flow through such a tube for various conditions have been developed. The effects of inertial and inclination angles that have not been discussed previously have been included. It has been shown that different flows for a uniform tube (vein) are possible. However, this flow matches that of a jugular vein which is supercritical, and the steady solution has been given by the balance between the driving forces of gravity and the viscous resistance to the flow at the right atrium of the heart must be sub-critical for a fixed right-atrium pressure which means that an elastic jump is required to return the flow to sub-critical from the supercritical flow upstream this type of relationship gives rise to flow limitation at the same time given any right atrium fixed pressure there exists a maximum flow rate which when exceeded the boundary conditions of the flow do not hold boundary conditions at the right atrium are not satisfied hence making the steady flow impossible this mechanism of flow limitation is slightly different from the other one in that causes airways through forced expiration from the observation made it is clearly shown that there is an intravascular pressure difference with a change in height.展开更多
The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass...The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass transfer directions are considered in experiments.The influences of operating variables containing agitation rate,dispersed and continuous phase flow rates and mass transfer in the extraction column are studied.According to obtained results,mass transfer is significantly dependent on agitation rate,while the dispersed and continuous phase flow rates have a minor effect on mass transfer in the extraction column.Furthermore,a novel empirical correlation is developed for prediction of overall continuous phase Sherwood number based on dispersed phase holdup,Reynolds number and mass transfer direction.There has been great agreement between experimental data and predicted values using a proposed correlation for all operating conditions.展开更多
The Archaean lower crust represented by granulite facies rocks, which is rare in China, is found to be exposed in the Shanxi-Hebei-Inner Mongolia border region. Studies of the regional structure and deformation and me...The Archaean lower crust represented by granulite facies rocks, which is rare in China, is found to be exposed in the Shanxi-Hebei-Inner Mongolia border region. Studies of the regional structure and deformation and metamorphism of the region indicate that there occurred at least two phases of deformation and metamorphism in the region. Early-phase nearly E-W-directed deformational structure is well preserved in the Zhangjiakou-Xuanhua area. Observations of the features of the geological structure from north to south (in the Hengshan metamorphic terrain) have revealed a possible exposed cross-section through the Archaean lower crust. The structure was superimposed by a NE-SW-trending high-temperature ductile shear zone in the Datong area in the late phase, thus reworking the Archaean sequence.展开更多
Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters inclu...Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters including rotor speed and continuous and dispersed phase velocities on the volumetric overall mass transfer coefficients are investigated. The results show that the mass transfer performance is strongly dependent on agitation rate and interfacial tension, but only slightly dependent on phase flow rates. In this study, effective diffusivity is used instead of molecular diffusivity in the Gr?ber equation for estimation of dispersed phase overall mass transfer coefficient.The enhancement factor is determined experimentally and there from an empirical expression is derived for prediction of the enhancement factor as a function of Reynolds number. The predicted results compared to the experimental data show that the proposed correlation can efficiently predict the overall mass transfer coefficients in asymmetric rotating disk contactors.展开更多
The cross-sectional area (CSA) of small pulmonary vessels can be quantified by CT, which is a reliable method of evaluating vascular alterations in such vessels. However, the optimal number of slices required for accu...The cross-sectional area (CSA) of small pulmonary vessels can be quantified by CT, which is a reliable method of evaluating vascular alterations in such vessels. However, the optimal number of slices required for accurate quantitation remains unknown. We evaluated relationships among all slices at 10-mm interval and all slices at 3-cm interval, 6-cm interval, and 3-slices and found the closest correlation (0.939) between all slices at 10-mm intervals and 3-cm intervals. Thus, all slices at 3-cm intervals are suitable for accurately measuring CSA.展开更多
文摘BACKGROUND Neuropathy is a common complication of diabetes mellitus resulting from direct damage by hyperglycemia to the nerves and/or ischemia by microvascular injury to the endoneurial vessels which supply the nerves. Median nerve is one of the peripheral nerves commonly affected in diabetic neuropathy. The median nerve size has been studied in non-Nigerian diabetic populations. In attempt to contribute to existing literature, a study in a Nigerian population is needed.AIM To evaluate the cross-sectional area(CSA) of the median nerve using B-mode ultrasonography(USS) and the presence of peripheral neuropathy(PN) in a cohort of adult diabetic Nigerians.METHODS Demographic and anthropometric data of 85 adult diabetes mellitus(DM) and 85 age-and sex-matched apparently healthy control(HC) subjects were taken. A complete physical examination was performed on all study subjects to determine the presence of PN and modified Michigan Neuropathy Screening Instrument(MNSI) was used to grade its severity. Venous blood was taken from the study subjects for fasting lipid profile(FLP), fasting blood glucose(FBG) and glycated haemoglobin(HbA1 c) while their MN CSA was evaluated at a point 5 cm proximal to(5 cmCATL) and at the carpal tunnel(CATL) by high-resolution Bmode USS. Data was analysed using SPSS version 22.RESULTS The mean MN CSA was significantly thicker in DM subjects compared to the HC at 5 cmCATL(P < 0.01) and at the CATL(P < 0.01) on both sides. The presence of diabetic peripheral neuropathy(DPN) further increased the MN CSA at the CATL(P < 0.05) but not at 5 cmCATL(P > 0.05). However, the severity of DPN had no additional effect on MN CSA 5 cm proximal to and at the CATL. There was no significant association between MN CSA and duration of DM and glycemic control.CONCLUSION Thickening of the MN CSA at 5 cmCATL and CATL is seen in DM. Presence of DPN is associated with worse thickening of the MN CSA at the CATL but not at5 cmCATL. Severity of DPN, duration of DM, and glycemic control had no additional effect on the MN CSA.
基金the Science and Technology Foundation Program of Guizhou Province,No. J[2009]2157
文摘High-resolution ultrasonography was used to analyze the nerve cross-sectional area (CSA) of the median nerve at 7 sites: the wrist crease, pisiform bone, hamate bone, 6 cm proximal to the tip of the wrist crease, proximal forearm (where the nerve enters the pronator teres muscle), 4 cm proximal to the tip of the medial epicondyle, and mid-humerus (mid-point between elbow crease and axilla) in 200 healthy volunteers from Guiyang, China. Results showed similar CSA values between the left and right sides, but the CSA 6 cm proximal to the tip of the wrist crease, proximal forearm, 4 cm proximal to tip of the medial epicondyle, and mid-humerus in males was greater than that of females. Moreover, CSA values at the wrist crease, pisiform bone, and hamate bone were greater in the middle-aged and old groups when compared to the young group, and correlated with body mass and height. Thus, reference values of median nerve CSA of the upper limbs can facilitate the analysis of abnormal nerve conditions.
基金the support from the National Natural Science Foundation of China (22008157,21978178)。
文摘Rotating packed bed(RPB) is one of the most effective gas–liquid mass transfer enhancement reactors, its effective specific mass transfer area(ae) is critical to understand the mass transfer process. By using the NaOH–CO_(2) chemical absorption method, the aevalues of three RPB reactors with different rotor sizes were measured under different operation conditions. The results showed that the high gravity factor and liquid flow rate were major affecting factors, while the gas flow rate exhibited minor influence.The radius of packing is the dominant equipment factor to affect aevalue. The results indicated that the contact area depends on the dispersion of the liquid phase, thus the centrifugal force of rotating packed bed greatly influenced the aevalue. Moreover, the measured ae/ap(effective specific mass transfer area/specific surface area of packing) values were fitted with dimensionless correlation formulas. The unified correlation formula with dimensionless bed size parameter can well predict the experimental data and the prediction errors were within 15%.
基金supported by a grant from the Shanghai Key Laboratory of Peripheral Nerve and Microsurgery in China,No.14DZ2273300the Natural Science Foundation of Shanghai in China,No.13ZR1404600a grant from the National Key Basic Research Program of China(973 Program),No.2014CB542201
文摘Although ultrasound measurements have been used in previous studies on carpal tunnel syndrome to visualize injury to the median nerve, whether such ultrasound data can indicate the severity of carpal tunnel syndrome remains controversial. The cross-sectional areas of the median nerve at the tunnel inlet and outlet can show swelling and compression of the nerve at the carpal. We hypothesized that the ratio of the cross-sectional areas of the median nerve at the carpal tunnel inlet to outlet accurately reflects the severity of carpal tunnel syndrome. To test this, high-resolution ultrasound with a linear array transducer at 5–17 MHz was used to assess 77 patients with carpal tunnel syndrome. The results showed that the cut-off point for the inlet-to-outlet ratio was 1.14. Significant differences in the inlet-to-outlet ratio were found among patients with mild, moderate, and severe carpal tunnel syndrome. The cut-off point in the ratio of cross-sectional areas of the median nerve was 1.29 between mild and more severe(moderate and severe) carpal tunnel syndrome patients with 64.7% sensitivity and 72.7% specificity. The cut-off point in the ratio of cross-sectional areas of the median nerve was 1.52 between the moderate and severe carpal tunnel syndrome patients with 80.0% sensitivity and 64.7% specificity. These results suggest that the inlet-to-outlet ratio reflected the severity of carpal tunnel syndrome.
文摘BACKGROUND Acromioclavicular joint(ACJ)space narrowing has been considered to be an important diagnostic image parameter of ACJ osteoarthritis(ACJO).However,the morphology of the ACJ space is irregular because of osteophyte formation,subchondral irregularity,capsular distention,sclerosis,and erosion.Therefore,we created the ACJ cross-sectional area(ACJCSA)as a new diagnostic image parameter to assess the irregular morphologic changes of the ACJ.AIM To hypothesize that the ACJCSA is a new diagnostic image parameter for ACJO.METHODS ACJ samples were obtained from 35 patients with ACJO and 30 healthy individuals who underwent shoulder magnetic resonance(S-MR)imaging that revealed no evidence of ACJO.Oblique coronal,T2-weighted,fat-suppressed SMR images were acquired at the ACJ level from the two groups.We measured the ACJCSA and the ACJ space width(ACJSW)at the ACJ on the S-MR images using our imaging analysis program.The ACJCSA was measured as the cross-sectional area of the ACJ.The ACJSW was measured as the narrowest point between the acromion and the clavicle.RESULTS The average ACJCSA was 39.88±10.60 mm;in the normal group and 18.80±5.13 mm;in the ACJO group.The mean ACJSW was 3.51±0.58 mm in the normal group and 2.02±0.48 mm in the ACJO group.ACJO individuals had significantly lower ACJCSA and ACJSW than the healthy individuals.Receiver operating characteristic curve analyses demonstrated that the most suitable ACJCSA cutoff score was 26.14 mm^(2),with 91.4%sensitivity and 90.0%specificity.CONCLUSION The optimal ACJSW cutoff score was 2.37 mm,with 88.6%sensitivity and 96.7%specificity.Even though both the ACJCSA and ACJSW were significantly associated with ACJO,the ACJCSA was a more sensitive diagnostic image parameter.
文摘Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to describe the ideal correlation between the current ratio(y)and the cross-sectional area ratio(x)of the dual electrodes,where k is the filling ratio.Investigation was conducted on the electroslag casting process with dual electrodes of various cross-sectional areas,but at a constant k value.The experimental results indicated that the ideal correlation was obtained at the stable casting stage,and the fitting results were consistent with the experimental results at certain k values.The experimental findings show that better castings can be obtained when the current ratio is greater than 1.536 and the cross-sectional area ratio is greater than 0.5.
基金partially supported by National Natural Science Foundation of China(Nos.61864001 and 62163009)Key Projects of Guangxi Natural Science Foundation(No.2021JJD170019)+1 种基金the Foundation of Guangxi Key Laboratory of Automatic Detecting Technology and Instruments(Guilin University of Electronic Technology)(Nos.YQ21111 and YQ21204)Innovation Project of Guang Xi Graduate Education(No.YCSW2021181)。
文摘By tilting a plasma jet and rotating 360°,a large-area can be scanned and sterilized in a short time.Compared with the previous array device,this pipe has the significant advantages of high sterilization uniformity and low gas consumption.Firstly,a rotatable plasma jet device,which can control the swing and rotation of a jet pipe,is designed,and a corresponding theoretical model is established to guide the experiment.Secondly,with Staphylococcus aureus(S.aureus)and Escherichia coli(E.coli)as the target bacteria,the device achieves a short sterilization time of 158 s—the minimum sterilization flow of S.aureus and E.coli is 0.8 slm and 0.6 slm,respectively.The device is compared with an array plasma sterilization device in terms of sterilization speed and gas consumption.The results show that the device is not only better than an array plasma sterilization device with respect to scanning uniformity,but also far less than the array plasma sterilization device in gas consumption of 5 slm.Therefore,the device has great potential in applications involving efficient,large-area sterilization.
文摘机场飞行区现使用的场面监视方法存在着定位偏差较大、不稳定、易跳变、皆为点源定位等问题。针对这些问题,设计了基于视觉图像的飞行区监视方法,实现快速准确的目标检测和轮廓定位,使飞行区监视更加稳定精确。提出了一种基于MobileNetV3和YOLOv5的网络模型(以下称为MobileNetV3-YOLOv5),即在YOLOv5的主干中使用MobileNetV3,来提高对目标的检测速度和准确度;提出了一种基于优化特征点提取的改进定向快速旋转简报(Oriented FAST and Rotated BRIEF,ORB)算法,将图像分割成多个区域,分别提取每个区域的特征点,从而提高目标识别框内区域的特征点识别数量,再进行特征点聚类筛选,最后根据识别目标类型采用最小包围盒进行轮廓划分,得到目标的轮廓定位。试验结果表明:MobileNetV3-YOLOv5方法对比原始YOLOv5模型,在识别目标准确率方面提升5百分点,在效率方面提升14张/s;同时在0~60 m的范围内,轮廓估计误差仅为2.9%;体现了所提出的监视方法的有效性,可以提升飞行区监视定位准确性和运行安全性。
文摘This paper models the giraffe’s jugular veins as a uniform collapsible tube from a rigid skull. The equations governing one-dimensional steady flow through such a tube for various conditions have been developed. The effects of inertial and inclination angles that have not been discussed previously have been included. It has been shown that different flows for a uniform tube (vein) are possible. However, this flow matches that of a jugular vein which is supercritical, and the steady solution has been given by the balance between the driving forces of gravity and the viscous resistance to the flow at the right atrium of the heart must be sub-critical for a fixed right-atrium pressure which means that an elastic jump is required to return the flow to sub-critical from the supercritical flow upstream this type of relationship gives rise to flow limitation at the same time given any right atrium fixed pressure there exists a maximum flow rate which when exceeded the boundary conditions of the flow do not hold boundary conditions at the right atrium are not satisfied hence making the steady flow impossible this mechanism of flow limitation is slightly different from the other one in that causes airways through forced expiration from the observation made it is clearly shown that there is an intravascular pressure difference with a change in height.
文摘The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass transfer directions are considered in experiments.The influences of operating variables containing agitation rate,dispersed and continuous phase flow rates and mass transfer in the extraction column are studied.According to obtained results,mass transfer is significantly dependent on agitation rate,while the dispersed and continuous phase flow rates have a minor effect on mass transfer in the extraction column.Furthermore,a novel empirical correlation is developed for prediction of overall continuous phase Sherwood number based on dispersed phase holdup,Reynolds number and mass transfer direction.There has been great agreement between experimental data and predicted values using a proposed correlation for all operating conditions.
基金This research was supported by the National Natural Science Foundation of China grant 4913207O.
文摘The Archaean lower crust represented by granulite facies rocks, which is rare in China, is found to be exposed in the Shanxi-Hebei-Inner Mongolia border region. Studies of the regional structure and deformation and metamorphism of the region indicate that there occurred at least two phases of deformation and metamorphism in the region. Early-phase nearly E-W-directed deformational structure is well preserved in the Zhangjiakou-Xuanhua area. Observations of the features of the geological structure from north to south (in the Hengshan metamorphic terrain) have revealed a possible exposed cross-section through the Archaean lower crust. The structure was superimposed by a NE-SW-trending high-temperature ductile shear zone in the Datong area in the late phase, thus reworking the Archaean sequence.
文摘Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters including rotor speed and continuous and dispersed phase velocities on the volumetric overall mass transfer coefficients are investigated. The results show that the mass transfer performance is strongly dependent on agitation rate and interfacial tension, but only slightly dependent on phase flow rates. In this study, effective diffusivity is used instead of molecular diffusivity in the Gr?ber equation for estimation of dispersed phase overall mass transfer coefficient.The enhancement factor is determined experimentally and there from an empirical expression is derived for prediction of the enhancement factor as a function of Reynolds number. The predicted results compared to the experimental data show that the proposed correlation can efficiently predict the overall mass transfer coefficients in asymmetric rotating disk contactors.
文摘The cross-sectional area (CSA) of small pulmonary vessels can be quantified by CT, which is a reliable method of evaluating vascular alterations in such vessels. However, the optimal number of slices required for accurate quantitation remains unknown. We evaluated relationships among all slices at 10-mm interval and all slices at 3-cm interval, 6-cm interval, and 3-slices and found the closest correlation (0.939) between all slices at 10-mm intervals and 3-cm intervals. Thus, all slices at 3-cm intervals are suitable for accurately measuring CSA.