In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer a...In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer and data acquisition card are introduced, and the major error source, influence mechanism and processing method of data quantization error are dis- cussed. By means of hybrid programming approach of LabVIEW and MATLAB, the instantaneous rotation speed measurement system for the piston motor in variable speed hydraulic system is designed. The simulation and experimental results show that the designed instantaneous speed measurement system is feasible. Furthermore, the sampling frequency has an important influ- ence on the instantaneous rotation speed measurement of piston motor and higher sampling frequency can lower quantization er- ror and improve measurement accuracy.展开更多
We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase ...We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase shift and contrast of the interference fringe are experimentally investigated. The results show that the contrast of the interference fringe is well held when the platform is rotated, and the phase shift of the interference fringe is linearly proportional to the rotation rate of the platform. The long-term stability, which is evaluated by the overlapped Allan deviation, is 8.5 × 10^-6 rad/s over the integrating time of 1000s.展开更多
We measure the rotational populations of ultracold SS Rbla3 Cs molecules in the lowest vibrational ground state by a depletion spectroscopy and quantify the molecular production rate based on the measurement of single...We measure the rotational populations of ultracold SS Rbla3 Cs molecules in the lowest vibrational ground state by a depletion spectroscopy and quantify the molecular production rate based on the measurement of single ion signal area. The SSRb133Cs molecules in the X1∑+(v = 0) are formed from the short-range (2)^3П0+(V = 10, J = 0) molecular state. A home-made external-cavity diode laser is used as the depletion laser to measure the rotational populations of the formed molecules. Based on the determination of single ion signal, the production rates of molecules in the J=0 and J = 2 rotational levels are derived to be 4800mole/s and 7200mole/s, respectively. The resolution and quantification of molecules in rotational states are facilitative for the manipulation of rotational quantum state of ultracold molecules.展开更多
The plasma rotation velocity were measured in HL-1M with Doppler shifts of CⅢ、 C Ⅱ、 O Ⅱ and H. line by a SKD high resolution spectrometer. The effects .of density' hydrogen pellet injection and carbon impuri...The plasma rotation velocity were measured in HL-1M with Doppler shifts of CⅢ、 C Ⅱ、 O Ⅱ and H. line by a SKD high resolution spectrometer. The effects .of density' hydrogen pellet injection and carbon impurities injected by laser-blow-off on toroidal(V) and poloidal (Vθ)rotation velocity have been observed. The Vθ measured from H. line is only half of that from C Ⅱ impurity line.展开更多
This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linea...This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linear slide, where the roll error motion measurement will be carried out repeatedly to confirm whether the surface form errors of slide guideways in the linear slide are su ciently corrected by hand scraping process. In the proposed method, one of the clinometers is mounted on the slide table, while the other is placed on a vibration isolation table, on which the precision linear slide is mounted, so that influences of external disturbances can be cancelled. An experimental setup is built on a vibration isolation table, and some experiments are carried out to verify the feasibility of the proposed method.展开更多
A novel motion-blur-based method for measuring the angular amplitude of a high-frequency rotational vibration is schemed. The proposed approach combines the active vision concept and the mechanism of motion-from-blur,...A novel motion-blur-based method for measuring the angular amplitude of a high-frequency rotational vibration is schemed. The proposed approach combines the active vision concept and the mechanism of motion-from-blur, generates motion blur on the image plane actively by extending exposure time, and utilizes the motion blur information in polar images to estimate the angular amplitude of a high-frequency rotational vibration. This method obtains the analytical results of the angular vibration amplitude from the geometric moments of a motion blurred polar image and an unblurred image for reference. Experimental results are provided to validate the presented scheme.展开更多
Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram....Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.展开更多
Induction motor is used in many applications to drive an electromechanical system. Transients of the motor torque and speed are outlined by the inertia of rotating rotor. The paper deals with influence of rotor inerti...Induction motor is used in many applications to drive an electromechanical system. Transients of the motor torque and speed are outlined by the inertia of rotating rotor. The paper deals with influence of rotor inertia to transients of motor speed. The method of speed control measurement and experimental equipment is discussed. Simulation and experimental results are compared.展开更多
Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transfor...Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transformation to reconstruct magnetic rotation angle,so as to avoid the large current measurement error caused by the approximate measurement of the magnetic rotation angle.By extracting the direct current(DC)component and the alternating current(AC)component of the light intensity signal detected by the photoelectric detector(PD),the sine signal containing the magnetic rotation angle is directly obtained by dividing the two components,and then the triangular identity transformation method is used to linearly demodulate the magnetic rotation angle and reconstruct the current waveform.The experimental results show that the relative error of current measurement does not exceed 1.40%in the current range of 0.05—0.50 A,which is less than the approximate linear measurement(ALM)method,and the magnetic rotation angle and the current have a good linear relationship.展开更多
This paper presents a study on measuring rotation speed of moving glass beads with an average diameter of 500 p.m in a pilot-scale circulating fluidized bed (CFB) riser with a high-speed digital imaging system. Two ...This paper presents a study on measuring rotation speed of moving glass beads with an average diameter of 500 p.m in a pilot-scale circulating fluidized bed (CFB) riser with a high-speed digital imaging system. Two methods have been developed to calculate particle rotation speed from the particle images. The first method consists of a fully automated algorithm based on cross-correlation of gray distribution of particle images for particles whose rotation axes are (nearly) perpendicular to the imaging plane, and the second method calculates the speed of particle rotation by identifying its rotation axis using two or more characteristic points on its surface. The reliability of the two methods is verified by using a small sphere with known speed and direction of rotation. The first method is shown to be capable of measuring accurately the rotation speed for the particle with a rotation axis (nearly) perpendicular to the imaging plane and filtering off other particles using an appropriate threshold of correlation coefficient. The second method is shown to be capable of yielding both the speed and direction of particle rotation, with a measurement error of less than 10%. Results of both methods on real glass beads in a CFB riser are compared against each other.展开更多
We investigate the sensitivity of the angular rotation measurement with the method of homodyne detection in SU(2) and SU(1,1) interferometers by employing orbital angular momentum(OAM). By combining a coherent beam wi...We investigate the sensitivity of the angular rotation measurement with the method of homodyne detection in SU(2) and SU(1,1) interferometers by employing orbital angular momentum(OAM). By combining a coherent beam with a vacuum beam in an SU(2) interferometer, we get the sensitivity of the angular rotation measurement as 1/(2N^(1/2)l). We can surpass the limit of the angular rotation measurement in an SU(1,1) interferometer by combining a coherent beam with a vacuum beam or a squeezed vacuum beam when the probe beam has OAM. Without injection, the sensitivity can reach 1/(2N^(1/2)l). In addition, by employing another construction of an SU(1,1) interferometer where the pump beam has OAM, with the same injection of an SU(1,1) interferometer, the sensitivity of the angular rotation measurement can be improved by a factor of 2, reaching 1/(4Nl). The results confirm the potential of this technology for precision measurements in angular rotation measurements.展开更多
Based on a single-channel laser self-mixing interferometcr, we present a new silnultaneous measurement of the vibration amplitude and tile rotation angle of objects that both affect the power spectrum containing two p...Based on a single-channel laser self-mixing interferometcr, we present a new silnultaneous measurement of the vibration amplitude and tile rotation angle of objects that both affect the power spectrum containing two peaks of the interferometer signals. The fitted results indicate that the curve of the peak frequency versus the vibration amplitude follows a linear distribution, and the curve of the difference of the two-peak power values versus the angle follows a Gaussian distribution. A vibration amplitude with an error less than 3.0% and a rotation angle with an error less than 11.7% are calculated from the fitted results.展开更多
The measurement of an extremely small magneto-optical polarization rotation angle with high sensitivity is integral to many scientific and technological applications. In this Letter, we have presented a technique base...The measurement of an extremely small magneto-optical polarization rotation angle with high sensitivity is integral to many scientific and technological applications. In this Letter, we have presented a technique based on Faraday modulation combined with the optical differential method to measure an extremely small polari- zation rotation angle with high sensitivity. The theoretical and experimental results show that common mode noise is reduced appreciably and signal to noise ratio is enhanced. The effectiveness of this technique has been demonstrated by measuring the Verdet constant of terbium gallium garnet glass and measuring the small polari- zation rotation angle. A sensitivity of enhancement of one order of magnitude has been achieved using differ- ential detection based on Faraday modulation.展开更多
In this paper,we examine the tiny polarization rotation effect in total internal reflection due to the spin–orbit interaction of light.We find that the tiny polarization rotation rate will induce a geometric phase gr...In this paper,we examine the tiny polarization rotation effect in total internal reflection due to the spin–orbit interaction of light.We find that the tiny polarization rotation rate will induce a geometric phase gradient,which can be regarded as the physical origin of photonic spin Hall effect.We demonstrate that the spin-dependent splitting in position space is related to the polarization rotation in momentum space,while the spin-dependent splitting in momentum space is attributed to the polarization rotation in position space.Furthermore,we introduce a quantum weak measurement to determine the tiny polarization rotation rate.The rotation rate in momentum space is obtained with 118 nm,which manifests itself as a spatial shift,and the rotation rate in position space is achieved with 38 μrad∕λ,which manifests itself as an angular shift.The investigation of the polarization rotation characteristics will provide insights into the photonic spin Hall effect and will enable us to better understand the spin–orbit interaction of light.展开更多
An improved method, called Alternative Spectral Rotation (ASR) measure, for predicting protein coding regions in rice DNA has been developed. The method is based on the Spectral Rotation (SR) measure proposed by Kotla...An improved method, called Alternative Spectral Rotation (ASR) measure, for predicting protein coding regions in rice DNA has been developed. The method is based on the Spectral Rotation (SR) measure proposed by Kotlar and Lavner, and its accuracy is higher than that of the SR measure and the Spectral Content (SC) measure proposed by Tiwari et al. In order to increase the identifying accuracy, we chose three di?erent coding characters, namely the asymmetric, purine, and stop-codon variables as parameters, and an approving result was presented by the method of Linear Discriminant Analysis (LDA).展开更多
In order to improve the accuracy and universality of the rotational speed measurement,an instantaneous rotational speed measurement method based on laser Doppler technology is proposed.The composition and working prin...In order to improve the accuracy and universality of the rotational speed measurement,an instantaneous rotational speed measurement method based on laser Doppler technology is proposed.The composition and working principle of the new system are discussed in detail.Theoretical and experimental results show that the new rotational speed measurement system belongs to the non-contact method,which eliminates the quantization error of the contact method and greatly improves the applicability and accuracy.Compared to the commonly used method,the measurement accuracy of the new rotational speed measurement system will not be affected by the system’s installation angle deviation,and it does not need to measure the radius of the rotating body,so the influence of the radius fluctuation of the rotating body on the measurement accuracy can be avoided while outputting the rotational speed in real time.The relative error of the rotational speed measurement is less than 0.06%(1σ).展开更多
基金National Natural Science Foundation of China(No.51275375,No.51509006)Shaanxi Provincial Natural Science Basic Research Plan(No.2014JQ7246)+1 种基金The Science and Technology of Hubei Province(No.B2015115)Doctoral Research Foundation of Hubei University of Automotive Technology(No.BK201403)
文摘In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer and data acquisition card are introduced, and the major error source, influence mechanism and processing method of data quantization error are dis- cussed. By means of hybrid programming approach of LabVIEW and MATLAB, the instantaneous rotation speed measurement system for the piston motor in variable speed hydraulic system is designed. The simulation and experimental results show that the designed instantaneous speed measurement system is feasible. Furthermore, the sampling frequency has an important influ- ence on the instantaneous rotation speed measurement of piston motor and higher sampling frequency can lower quantization er- ror and improve measurement accuracy.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11227083 and 91536221
文摘We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase shift and contrast of the interference fringe are experimentally investigated. The results show that the contrast of the interference fringe is well held when the platform is rotated, and the phase shift of the interference fringe is linearly proportional to the rotation rate of the platform. The long-term stability, which is evaluated by the overlapped Allan deviation, is 8.5 × 10^-6 rad/s over the integrating time of 1000s.
基金Supported by the National Key Research and Development Program of China under Grant No 2017YFA0304203the National Natural Science Foundation of China under Grant Nos 61675120,11434007 and 61378015+1 种基金the Program for Changjiang Scholars and Innovative Research Team in University under Grant No IRT13076the Applied Basic Research Project of Shanxi Province under Grant No 201601D202008
文摘We measure the rotational populations of ultracold SS Rbla3 Cs molecules in the lowest vibrational ground state by a depletion spectroscopy and quantify the molecular production rate based on the measurement of single ion signal area. The SSRb133Cs molecules in the X1∑+(v = 0) are formed from the short-range (2)^3П0+(V = 10, J = 0) molecular state. A home-made external-cavity diode laser is used as the depletion laser to measure the rotational populations of the formed molecules. Based on the determination of single ion signal, the production rates of molecules in the J=0 and J = 2 rotational levels are derived to be 4800mole/s and 7200mole/s, respectively. The resolution and quantification of molecules in rotational states are facilitative for the manipulation of rotational quantum state of ultracold molecules.
文摘The plasma rotation velocity were measured in HL-1M with Doppler shifts of CⅢ、 C Ⅱ、 O Ⅱ and H. line by a SKD high resolution spectrometer. The effects .of density' hydrogen pellet injection and carbon impurities injected by laser-blow-off on toroidal(V) and poloidal (Vθ)rotation velocity have been observed. The Vθ measured from H. line is only half of that from C Ⅱ impurity line.
基金supported by Japan Society for the Promotion and Science (JSPS)
文摘This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linear slide, where the roll error motion measurement will be carried out repeatedly to confirm whether the surface form errors of slide guideways in the linear slide are su ciently corrected by hand scraping process. In the proposed method, one of the clinometers is mounted on the slide table, while the other is placed on a vibration isolation table, on which the precision linear slide is mounted, so that influences of external disturbances can be cancelled. An experimental setup is built on a vibration isolation table, and some experiments are carried out to verify the feasibility of the proposed method.
基金This project is supported by National Natural Science Foundation of China (No. 50375099, No. 50390064)
文摘A novel motion-blur-based method for measuring the angular amplitude of a high-frequency rotational vibration is schemed. The proposed approach combines the active vision concept and the mechanism of motion-from-blur, generates motion blur on the image plane actively by extending exposure time, and utilizes the motion blur information in polar images to estimate the angular amplitude of a high-frequency rotational vibration. This method obtains the analytical results of the angular vibration amplitude from the geometric moments of a motion blurred polar image and an unblurred image for reference. Experimental results are provided to validate the presented scheme.
文摘Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.
文摘Induction motor is used in many applications to drive an electromechanical system. Transients of the motor torque and speed are outlined by the inertia of rotating rotor. The paper deals with influence of rotor inertia to transients of motor speed. The method of speed control measurement and experimental equipment is discussed. Simulation and experimental results are compared.
基金the Joint Guidance Project of Natural Science Foundation of Heilongjiang Province(No.LH2021F008)。
文摘Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transformation to reconstruct magnetic rotation angle,so as to avoid the large current measurement error caused by the approximate measurement of the magnetic rotation angle.By extracting the direct current(DC)component and the alternating current(AC)component of the light intensity signal detected by the photoelectric detector(PD),the sine signal containing the magnetic rotation angle is directly obtained by dividing the two components,and then the triangular identity transformation method is used to linearly demodulate the magnetic rotation angle and reconstruct the current waveform.The experimental results show that the relative error of current measurement does not exceed 1.40%in the current range of 0.05—0.50 A,which is less than the approximate linear measurement(ALM)method,and the magnetic rotation angle and the current have a good linear relationship.
基金supports from the Special Funds for China Major State Basic Research Projects(Grant 2005CB221201)the National Natural Science Foundation Projects (Grant 50806067)the Program of Introducing Talents of Discipline to University (B08026)
文摘This paper presents a study on measuring rotation speed of moving glass beads with an average diameter of 500 p.m in a pilot-scale circulating fluidized bed (CFB) riser with a high-speed digital imaging system. Two methods have been developed to calculate particle rotation speed from the particle images. The first method consists of a fully automated algorithm based on cross-correlation of gray distribution of particle images for particles whose rotation axes are (nearly) perpendicular to the imaging plane, and the second method calculates the speed of particle rotation by identifying its rotation axis using two or more characteristic points on its surface. The reliability of the two methods is verified by using a small sphere with known speed and direction of rotation. The first method is shown to be capable of measuring accurately the rotation speed for the particle with a rotation axis (nearly) perpendicular to the imaging plane and filtering off other particles using an appropriate threshold of correlation coefficient. The second method is shown to be capable of yielding both the speed and direction of particle rotation, with a measurement error of less than 10%. Results of both methods on real glass beads in a CFB riser are compared against each other.
基金National Natural Science Foundation of China(NSFC)(11774286,11374238,11534008,11574247)
文摘We investigate the sensitivity of the angular rotation measurement with the method of homodyne detection in SU(2) and SU(1,1) interferometers by employing orbital angular momentum(OAM). By combining a coherent beam with a vacuum beam in an SU(2) interferometer, we get the sensitivity of the angular rotation measurement as 1/(2N^(1/2)l). We can surpass the limit of the angular rotation measurement in an SU(1,1) interferometer by combining a coherent beam with a vacuum beam or a squeezed vacuum beam when the probe beam has OAM. Without injection, the sensitivity can reach 1/(2N^(1/2)l). In addition, by employing another construction of an SU(1,1) interferometer where the pump beam has OAM, with the same injection of an SU(1,1) interferometer, the sensitivity of the angular rotation measurement can be improved by a factor of 2, reaching 1/(4Nl). The results confirm the potential of this technology for precision measurements in angular rotation measurements.
基金supported by the National Natural Science Foundation of China under Grant Nos.61275165,61201401,and 61307098
文摘Based on a single-channel laser self-mixing interferometcr, we present a new silnultaneous measurement of the vibration amplitude and tile rotation angle of objects that both affect the power spectrum containing two peaks of the interferometer signals. The fitted results indicate that the curve of the peak frequency versus the vibration amplitude follows a linear distribution, and the curve of the difference of the two-peak power values versus the angle follows a Gaussian distribution. A vibration amplitude with an error less than 3.0% and a rotation angle with an error less than 11.7% are calculated from the fitted results.
基金supported by the National Key R&D Program of China(No.2017YFB0503100)the National Science Foundation of China(NSFC)(No.61227902)
文摘The measurement of an extremely small magneto-optical polarization rotation angle with high sensitivity is integral to many scientific and technological applications. In this Letter, we have presented a technique based on Faraday modulation combined with the optical differential method to measure an extremely small polari- zation rotation angle with high sensitivity. The theoretical and experimental results show that common mode noise is reduced appreciably and signal to noise ratio is enhanced. The effectiveness of this technique has been demonstrated by measuring the Verdet constant of terbium gallium garnet glass and measuring the small polari- zation rotation angle. A sensitivity of enhancement of one order of magnitude has been achieved using differ- ential detection based on Faraday modulation.
基金National Natural Science Foundation of China(NSFC)(11274106,11474089)
文摘In this paper,we examine the tiny polarization rotation effect in total internal reflection due to the spin–orbit interaction of light.We find that the tiny polarization rotation rate will induce a geometric phase gradient,which can be regarded as the physical origin of photonic spin Hall effect.We demonstrate that the spin-dependent splitting in position space is related to the polarization rotation in momentum space,while the spin-dependent splitting in momentum space is attributed to the polarization rotation in position space.Furthermore,we introduce a quantum weak measurement to determine the tiny polarization rotation rate.The rotation rate in momentum space is obtained with 118 nm,which manifests itself as a spatial shift,and the rotation rate in position space is achieved with 38 μrad∕λ,which manifests itself as an angular shift.The investigation of the polarization rotation characteristics will provide insights into the photonic spin Hall effect and will enable us to better understand the spin–orbit interaction of light.
文摘An improved method, called Alternative Spectral Rotation (ASR) measure, for predicting protein coding regions in rice DNA has been developed. The method is based on the Spectral Rotation (SR) measure proposed by Kotlar and Lavner, and its accuracy is higher than that of the SR measure and the Spectral Content (SC) measure proposed by Tiwari et al. In order to increase the identifying accuracy, we chose three di?erent coding characters, namely the asymmetric, purine, and stop-codon variables as parameters, and an approving result was presented by the method of Linear Discriminant Analysis (LDA).
文摘In order to improve the accuracy and universality of the rotational speed measurement,an instantaneous rotational speed measurement method based on laser Doppler technology is proposed.The composition and working principle of the new system are discussed in detail.Theoretical and experimental results show that the new rotational speed measurement system belongs to the non-contact method,which eliminates the quantization error of the contact method and greatly improves the applicability and accuracy.Compared to the commonly used method,the measurement accuracy of the new rotational speed measurement system will not be affected by the system’s installation angle deviation,and it does not need to measure the radius of the rotating body,so the influence of the radius fluctuation of the rotating body on the measurement accuracy can be avoided while outputting the rotational speed in real time.The relative error of the rotational speed measurement is less than 0.06%(1σ).