A digitally controlled three-dimensional gamma-scanning apparatus was developed and used to troubleshoot distillation column in the present investigation. In a 140mm(ID) model colum, various malfunctional phenomena,bo...A digitally controlled three-dimensional gamma-scanning apparatus was developed and used to troubleshoot distillation column in the present investigation. In a 140mm(ID) model colum, various malfunctional phenomena,both rate and process related conditions and structural problems, which may be frequently encountered in the operation of tray and packing columns, were experimentally simulated and tested with the developed scanning system. The experimental results showed that the scanning spectra can fairly reflect the simulated phenomena. The salient feature of the scanning apparatus lies in that it integrates the so called grid scan and computer-assisted tomography scan in a single system. It was confirmed that the gamma-scanning technique can serve as an important on-line troubleshooting and maintenance tool.展开更多
Photoacoustic imaging,which can provide the maximum intensity contrast in tissue depth imaging without ionizing radiation,will be a promising imaging trend for tumor detection.In this paper,a column diffusionfiber was...Photoacoustic imaging,which can provide the maximum intensity contrast in tissue depth imaging without ionizing radiation,will be a promising imaging trend for tumor detection.In this paper,a column diffusionfiber was employed to carry a pulsed laser for irradiating stomach directly through esophagus based on the characteristics of gastric tissue structure.A long focused ultrasonic transducer was placed outside the body to detect photoacoustic signals of gastric tissue.Phantom and in vitro experiments of submucosal gastric tumors were carried out to check the sensitivity of scanning photoacoustic tomography system,including the lateral and longitudinal resolution of the system,sensitivity of different absorption coefficient in imaging,capability of transversal detection,and probability of longitudinal detection.The results demonstrate that our innovative technique can improve the parameters of imaging.The lateral resolution reaches 2.09 mm.Then a depth of 5.5mm with a longitudinal accuracy of 0.36mm below gastric mucosa of early gastric cancer(EGC)has been achieved.In addition,the optimal absorption coefficient differences among absorbers of system are 3.3-3.9 times.Results indicate that our photoacoustic imaging(PAI)system,is based on a long focusing transducer,can provide a potential application for detecting submucosal EGC without obvious symptoms.展开更多
A new concept, called the row-column visibility graph, is proposed to map two-dimensional landscapes to complex networks. A cluster coverage is introduced to describe the extensive property of node clusters on a Eucli...A new concept, called the row-column visibility graph, is proposed to map two-dimensional landscapes to complex networks. A cluster coverage is introduced to describe the extensive property of node clusters on a Euclidean lattice. Graphs mapped from fractals generated with the probability redistribution model behave scale-free. They have pattern-induced hierarchical organizations and comparatively much more extensive structures. The scale-free exponent has a negative correlation with the Hurst exponent, however, there is no deterministic relation between them. Graphs for fractals generated with the midpoint displacement model are exponential networks. When the Hurst exponent is large enough (e.g., H 〉 0.5), the degree distribution decays much more slowly, the average coverage becomes significant large, and the initially hierarchical structure at H 〈 0.5 is destroyed completely. Hence, the row-column visibility graph can be used to detect the pattern-related new characteristics of two-dimensional landscapes.展开更多
We investigated the longitudinal positional dependence of CT number in 320-row Cone Beam Computed Tomography (CBCT) volume scan (320-row volume scan) using a simple geometric phantom (SGP) and a chest simulation phant...We investigated the longitudinal positional dependence of CT number in 320-row Cone Beam Computed Tomography (CBCT) volume scan (320-row volume scan) using a simple geometric phantom (SGP) and a chest simulation phantom (CSP) in order to evaluate its effect on proton range calculation. The SGP consisted of lung substitute material (LSM) and a cylindrical phantom (CP) made of high-density polyethylene. The CSP was an anthropomorphic phantom similar to the human chest. The two phantoms were scanned using 320-row volume scan in various longitudinal positions from the central beam axis. In experiments using the SGP, an image blur at the boundary of the two materials became gradually evident when the LSM was placed far away from the beam central axis. The image blur of the phantom was consistent with the gradation in CT number. The maximum difference in CT numbers between the 64-row helical scan and 320-row volume scan at the boundary of the two materials was consistent with approximately 50% of the relative proton stopping power. In contrast, the CT number profile in each longitudinal position was fairly consistent and longitudinal positional dependence rarely occurred in the CSP experiments. Pass lengths of CT beams through areas with widely different electron densities were shorter, and thus did not significantly impact CT numbers. Based on findings from the CSP experiments, we considered 320-row volume scan to be feasible for proton range calculation in clinical settings, although the relatively large longitudinal positional dependence of CT number should be accounted for when doing so.展开更多
In three-dimensional computed tomography angiography (3D-CTA) in our facility, we usually scan the volume of the brain according to the bolus tracking method. Fluoroscopic slice is placed at the Willis’s ring and the...In three-dimensional computed tomography angiography (3D-CTA) in our facility, we usually scan the volume of the brain according to the bolus tracking method. Fluoroscopic slice is placed at the Willis’s ring and the timing of scan is determined subjectively by a radiological technologist after strong enhancement of the basal cerebral artery is confirmed. In these procedures, however, variation of scan timing is often problematic. Therefore, we design the surpassing method to place the small region-of-interest (ROI) at the basal cerebral arteries and to start CT scan automatically. In this protocol, the fluoroscopic slices of the distal internal carotid arteries are selected referring to the precontrast volume data, small ROIs are set in bilateral internal carotid arteries, and scan trigger of CT is started automatically at the threshold of 170 HU. The maximum 80 mL of iodine contrast agent 300 mgI/mL is injected intravenously at the rate of 4.0 mL/sec, and the volume of the arterial phase is scanned automatically. We measure ROIs at the internal carotid arteries based on the obtained volume data of arterial phase and estimate the optimal scan timings from the fluoroscopic CT images reformatted at the intervals of 0.1 sec. In 38 of 53 patients, placement of the small ROIs is succeeded and automatic or manual CT scan is performed. In the patients who succeed in placement of the small ROIs, optimal scan timing of the arterial phase is obtained, while in the patients who fail placement of the small ROIs, a large variation is observed in their scan timings. Their results suggest that more stable scanning of the arterial phase is available by means of small ROI placement and automatic scanning. The clinical significance is large because the stability and reproducibility of the examination provide a quantitative analysis and more accurate diagnosis.展开更多
基金the Department of Research and Development, SINOPEC.
文摘A digitally controlled three-dimensional gamma-scanning apparatus was developed and used to troubleshoot distillation column in the present investigation. In a 140mm(ID) model colum, various malfunctional phenomena,both rate and process related conditions and structural problems, which may be frequently encountered in the operation of tray and packing columns, were experimentally simulated and tested with the developed scanning system. The experimental results showed that the scanning spectra can fairly reflect the simulated phenomena. The salient feature of the scanning apparatus lies in that it integrates the so called grid scan and computer-assisted tomography scan in a single system. It was confirmed that the gamma-scanning technique can serve as an important on-line troubleshooting and maintenance tool.
基金This work was supported by the National Science Foundation of China(Grant Nos:61675043 and 81571726)the Natural Science Foundation of Fujian Province(Grant No:2018J01785).
文摘Photoacoustic imaging,which can provide the maximum intensity contrast in tissue depth imaging without ionizing radiation,will be a promising imaging trend for tumor detection.In this paper,a column diffusionfiber was employed to carry a pulsed laser for irradiating stomach directly through esophagus based on the characteristics of gastric tissue structure.A long focused ultrasonic transducer was placed outside the body to detect photoacoustic signals of gastric tissue.Phantom and in vitro experiments of submucosal gastric tumors were carried out to check the sensitivity of scanning photoacoustic tomography system,including the lateral and longitudinal resolution of the system,sensitivity of different absorption coefficient in imaging,capability of transversal detection,and probability of longitudinal detection.The results demonstrate that our innovative technique can improve the parameters of imaging.The lateral resolution reaches 2.09 mm.Then a depth of 5.5mm with a longitudinal accuracy of 0.36mm below gastric mucosa of early gastric cancer(EGC)has been achieved.In addition,the optimal absorption coefficient differences among absorbers of system are 3.3-3.9 times.Results indicate that our photoacoustic imaging(PAI)system,is based on a long focusing transducer,can provide a potential application for detecting submucosal EGC without obvious symptoms.
基金supported by the National Natural Science Foundation of China(Grant No.10975099)the Program for Professor of Special Appointment(Eastern Scholar)at Shanghai Institutions of Higher Learning,China+2 种基金the Innovation Program of Shanghai Municipal Education Commission,China(GrantNo.13YZ072)the Shanghai Leading Discipline Project,China(Grant No.XTKX2012)the Innovation Fund Project for Graduate Students of Shanghai,China(Grant No.JWCXSL1302)
文摘A new concept, called the row-column visibility graph, is proposed to map two-dimensional landscapes to complex networks. A cluster coverage is introduced to describe the extensive property of node clusters on a Euclidean lattice. Graphs mapped from fractals generated with the probability redistribution model behave scale-free. They have pattern-induced hierarchical organizations and comparatively much more extensive structures. The scale-free exponent has a negative correlation with the Hurst exponent, however, there is no deterministic relation between them. Graphs for fractals generated with the midpoint displacement model are exponential networks. When the Hurst exponent is large enough (e.g., H 〉 0.5), the degree distribution decays much more slowly, the average coverage becomes significant large, and the initially hierarchical structure at H 〈 0.5 is destroyed completely. Hence, the row-column visibility graph can be used to detect the pattern-related new characteristics of two-dimensional landscapes.
文摘We investigated the longitudinal positional dependence of CT number in 320-row Cone Beam Computed Tomography (CBCT) volume scan (320-row volume scan) using a simple geometric phantom (SGP) and a chest simulation phantom (CSP) in order to evaluate its effect on proton range calculation. The SGP consisted of lung substitute material (LSM) and a cylindrical phantom (CP) made of high-density polyethylene. The CSP was an anthropomorphic phantom similar to the human chest. The two phantoms were scanned using 320-row volume scan in various longitudinal positions from the central beam axis. In experiments using the SGP, an image blur at the boundary of the two materials became gradually evident when the LSM was placed far away from the beam central axis. The image blur of the phantom was consistent with the gradation in CT number. The maximum difference in CT numbers between the 64-row helical scan and 320-row volume scan at the boundary of the two materials was consistent with approximately 50% of the relative proton stopping power. In contrast, the CT number profile in each longitudinal position was fairly consistent and longitudinal positional dependence rarely occurred in the CSP experiments. Pass lengths of CT beams through areas with widely different electron densities were shorter, and thus did not significantly impact CT numbers. Based on findings from the CSP experiments, we considered 320-row volume scan to be feasible for proton range calculation in clinical settings, although the relatively large longitudinal positional dependence of CT number should be accounted for when doing so.
文摘In three-dimensional computed tomography angiography (3D-CTA) in our facility, we usually scan the volume of the brain according to the bolus tracking method. Fluoroscopic slice is placed at the Willis’s ring and the timing of scan is determined subjectively by a radiological technologist after strong enhancement of the basal cerebral artery is confirmed. In these procedures, however, variation of scan timing is often problematic. Therefore, we design the surpassing method to place the small region-of-interest (ROI) at the basal cerebral arteries and to start CT scan automatically. In this protocol, the fluoroscopic slices of the distal internal carotid arteries are selected referring to the precontrast volume data, small ROIs are set in bilateral internal carotid arteries, and scan trigger of CT is started automatically at the threshold of 170 HU. The maximum 80 mL of iodine contrast agent 300 mgI/mL is injected intravenously at the rate of 4.0 mL/sec, and the volume of the arterial phase is scanned automatically. We measure ROIs at the internal carotid arteries based on the obtained volume data of arterial phase and estimate the optimal scan timings from the fluoroscopic CT images reformatted at the intervals of 0.1 sec. In 38 of 53 patients, placement of the small ROIs is succeeded and automatic or manual CT scan is performed. In the patients who succeed in placement of the small ROIs, optimal scan timing of the arterial phase is obtained, while in the patients who fail placement of the small ROIs, a large variation is observed in their scan timings. Their results suggest that more stable scanning of the arterial phase is available by means of small ROI placement and automatic scanning. The clinical significance is large because the stability and reproducibility of the examination provide a quantitative analysis and more accurate diagnosis.
文摘三维超快成像是超声技术发展的重要方向.基于二维全采样阵列的传统三维成像方法需要较多成像阵元和采样通道,其紧密的阵元排列设计也客观上限制了阵列孔径大小和成像分辨率.行列寻址(row-column addressing,RCA)探头以行列检索的方式将通道数自N×N减少为N+N,从而极大地降低了阵列的硬件实现成本.本文仿真了中心频率为6MHz的128行+128列的RCA阵列,结合多角度平面波正交复合成像方法,通过延时叠加(delay and sum,DAS)波束合成、基于特征值分解(singular value decomposition,SVD)的杂波滤除和自相关多普勒速度求解算法,实现了血流仿体的多普勒成像,并分析了不同复合角度序列对成像效果的影响.定量分析表明,当角度数从5个增至33个时,-6 dB分辨率从0.986 mm提升至0.493 mm;当复合角度为17个时,功率多普勒图像的SNR可达30 dB,彩色多普勒沿直径方向的速度分布和真实值的平均误差约为26.0%.以上结果表明,基于RCA阵列的三维成像技术能够获得三维B-mode、功率多普勒和彩色多普勒图像,增大复合平面波角度数和角度范围可显著提高成像质量.本研究对于三维超快超声多普勒成像技术发展具有借鉴意义,相关方法有应用于血流血管成像,并进一步实现基于神经-血管耦合的组织功能监测与成像的潜力和前景.