To overcome the large time-delay in measuring the hardness of mixed rubber, rheological parameters were used to predict the hardness. A novel Q-based model updating strategy was proposed as a universal platform to tra...To overcome the large time-delay in measuring the hardness of mixed rubber, rheological parameters were used to predict the hardness. A novel Q-based model updating strategy was proposed as a universal platform to track time-varying properties. Using a few selected support samples to update the model, the strategy could dramat- ically save the storage cost and overcome the adverse influence of low signal-to-noise ratio samples. Moreover, it could be applied to any statistical process monitoring system without drastic changes to them, which is practical for industrial practices. As examples, the Q-based strategy was integrated with three popular algorithms (partial least squares (PIE), recursive PIE (RPLS), and kernel PIE (KPIE)) to form novel regression ones, QPLS, QRPIE and QKPLS, respectively. The applications for predicting mixed rubber hardness on a large-scale tire plant in east China prove the theoretical considerations.展开更多
The existing absorption coefficient measurement in a water tube is limited in low frequency due to the limitation of the pulse tube length.A wide-band pulse tube method based on the post-processing inverse filter is p...The existing absorption coefficient measurement in a water tube is limited in low frequency due to the limitation of the pulse tube length.A wide-band pulse tube method based on the post-processing inverse filter is proposed.After obtaining the response of the entire system,the transducer is excited with wide-band,short-duration signals.Then,the received signals are processed with inverse filters and the "blurred" reflective signals of standard reflector and test sample are recovered respectively,finally,the reflection coefficient and absorption coefficient are calculated.Simulation work is implemented to verify the advantage of postprocessing inverse filter over pre-processing inverse filter in terms of low frequency measurement.To verify the proposed method,two different wide-band pulses in the separate frequency ranges are adopted to measure the same rubber material.The experimental results indicate that the wide-band pulse method and CW(Continuous Wave) pulse method have good agreement in both low frequency range and high frequency range.Wide-band pulse method is of high efficiency,and the low frequency reaches 350 Hz,which is able to extend the low frequency range.展开更多
文摘To overcome the large time-delay in measuring the hardness of mixed rubber, rheological parameters were used to predict the hardness. A novel Q-based model updating strategy was proposed as a universal platform to track time-varying properties. Using a few selected support samples to update the model, the strategy could dramat- ically save the storage cost and overcome the adverse influence of low signal-to-noise ratio samples. Moreover, it could be applied to any statistical process monitoring system without drastic changes to them, which is practical for industrial practices. As examples, the Q-based strategy was integrated with three popular algorithms (partial least squares (PIE), recursive PIE (RPLS), and kernel PIE (KPIE)) to form novel regression ones, QPLS, QRPIE and QKPLS, respectively. The applications for predicting mixed rubber hardness on a large-scale tire plant in east China prove the theoretical considerations.
基金supported by the National Natural Science Foundation of China(11474230)the National Key Research and Development Program of China(2016YFF0200900)the Science and Technology Research and Development Program of Shaanxi Province(2016GY-111)
文摘The existing absorption coefficient measurement in a water tube is limited in low frequency due to the limitation of the pulse tube length.A wide-band pulse tube method based on the post-processing inverse filter is proposed.After obtaining the response of the entire system,the transducer is excited with wide-band,short-duration signals.Then,the received signals are processed with inverse filters and the "blurred" reflective signals of standard reflector and test sample are recovered respectively,finally,the reflection coefficient and absorption coefficient are calculated.Simulation work is implemented to verify the advantage of postprocessing inverse filter over pre-processing inverse filter in terms of low frequency measurement.To verify the proposed method,two different wide-band pulses in the separate frequency ranges are adopted to measure the same rubber material.The experimental results indicate that the wide-band pulse method and CW(Continuous Wave) pulse method have good agreement in both low frequency range and high frequency range.Wide-band pulse method is of high efficiency,and the low frequency reaches 350 Hz,which is able to extend the low frequency range.