The capacity and size of hydro-generator units are increasing with the rapid development of hydroelectric enterprises, and the vibration of the powerhouse structure has increasingly become a major problem. Field testi...The capacity and size of hydro-generator units are increasing with the rapid development of hydroelectric enterprises, and the vibration of the powerhouse structure has increasingly become a major problem. Field testing is an important method for research on dynamic identification and vibration mechanisms. Research on optimal sensor placement has become a very important topic due to the need to obtain effective testing information from limited test resources. To overcome inadequacies of the present methods, this paper puts forward the triaxial effective independence driving-point residue (EfI3-DPR3) method for optimal sensor placement. The Efl3-DPR3 method can incorporate both the maximum triaxial modal kinetic energy and linear independence of the triaxial target modes at the selected nodes. It was applied to the optimal placement oftriaxial sensors for vibration testing in a hydropower house, and satisfactory results were obtained. This method can provide some guidance for optimal placement of triaxial sensors of underground powerhouses.展开更多
By using the shear stress transport (SST) model to predict the effect ot random now motion in a fluid zone, and using the Newmark method to solve the oscillation equations in a solid zone, a coupling model of the .p...By using the shear stress transport (SST) model to predict the effect ot random now motion in a fluid zone, and using the Newmark method to solve the oscillation equations in a solid zone, a coupling model of the .powerhouse and its tube water was developed. The effects of fluid-structure interaction are considered through the kinematic and dynamic conditions applied to the fluid-structure interfaces (FSI). Numerical simulation of turbulent flow through the whole flow passage of the powerhouse and concrete structure vibration analysis in the time domain were carried out with the model. Considering the effect of coupling the turbulence and the powerhouse structure, the time history response of both turbulent flows through the whole flow passage and powerhouse structure vibration were generated. Concrete structure vibration analysis shows that the displacement, velocity, and acceleration of the dynamo floor respond dramatically to pressure fluctuations in the flow passage. Furthermore, the spectrum analysis suggests that pressure fluctuation originating from the static and dynamic disturbances of hydraulic turbine blades in the flow passage is one of the most important vibration sources.展开更多
This paper establishes a 3D numerical model for 15# hydropower house of the Three Gorges Project (TGP) and performs a nonlinear static and dynamic damage analysis. In this numerical model, a coupling model of finite a...This paper establishes a 3D numerical model for 15# hydropower house of the Three Gorges Project (TGP) and performs a nonlinear static and dynamic damage analysis. In this numerical model, a coupling model of finite and infinite elements for simulating infinite foundation of hydropower station is adopted. A plastic-damage model based on continuum damage mechanics, which includes the softening and damage behavior under tension is considered for the concrete material. The dynamic equilibrium equations of moti...展开更多
目前水电站厂房的振动问题日益突出.根据当前水电站厂房振动研究和振动载荷特性识别的需要,总结了土木工程中几种常用的传感器优化布设准则,选择了BDA(backw ardde letion a lgorithm)方法;基于AN SY S-APDL二次开发技术,编写了适于水...目前水电站厂房的振动问题日益突出.根据当前水电站厂房振动研究和振动载荷特性识别的需要,总结了土木工程中几种常用的传感器优化布设准则,选择了BDA(backw ardde letion a lgorithm)方法;基于AN SY S-APDL二次开发技术,编写了适于水电站建筑物应用的Fortran程序;将传感器优化理论与方法应用于红石水电站厂房振动分析,建立了有限元数值模型及振动模态分析方法,对传感器布置进行了优化.发现选取前两阶振型参与优化布设已可满足要求,可为厂房的振动测量和动态识别提供较为可靠的数据.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 50909072)the New Teachers' Fund for Doctor Station, the Ministry of Education of China (Grant No. 20090032120082)the Communication Research Item for the West Area, the Ministry of Communications of China (Grant No. 2009328000084)
文摘The capacity and size of hydro-generator units are increasing with the rapid development of hydroelectric enterprises, and the vibration of the powerhouse structure has increasingly become a major problem. Field testing is an important method for research on dynamic identification and vibration mechanisms. Research on optimal sensor placement has become a very important topic due to the need to obtain effective testing information from limited test resources. To overcome inadequacies of the present methods, this paper puts forward the triaxial effective independence driving-point residue (EfI3-DPR3) method for optimal sensor placement. The Efl3-DPR3 method can incorporate both the maximum triaxial modal kinetic energy and linear independence of the triaxial target modes at the selected nodes. It was applied to the optimal placement oftriaxial sensors for vibration testing in a hydropower house, and satisfactory results were obtained. This method can provide some guidance for optimal placement of triaxial sensors of underground powerhouses.
基金supported by the National Natural Science Foundation of China (Grant No.90510017)
文摘By using the shear stress transport (SST) model to predict the effect ot random now motion in a fluid zone, and using the Newmark method to solve the oscillation equations in a solid zone, a coupling model of the .powerhouse and its tube water was developed. The effects of fluid-structure interaction are considered through the kinematic and dynamic conditions applied to the fluid-structure interfaces (FSI). Numerical simulation of turbulent flow through the whole flow passage of the powerhouse and concrete structure vibration analysis in the time domain were carried out with the model. Considering the effect of coupling the turbulence and the powerhouse structure, the time history response of both turbulent flows through the whole flow passage and powerhouse structure vibration were generated. Concrete structure vibration analysis shows that the displacement, velocity, and acceleration of the dynamo floor respond dramatically to pressure fluctuations in the flow passage. Furthermore, the spectrum analysis suggests that pressure fluctuation originating from the static and dynamic disturbances of hydraulic turbine blades in the flow passage is one of the most important vibration sources.
基金Supported by National Natural Science Foundation of China (No.50679009)Key Laboratory for Scientific Research of Department of Education in Liaoning Province (No.2008S045)
文摘This paper establishes a 3D numerical model for 15# hydropower house of the Three Gorges Project (TGP) and performs a nonlinear static and dynamic damage analysis. In this numerical model, a coupling model of finite and infinite elements for simulating infinite foundation of hydropower station is adopted. A plastic-damage model based on continuum damage mechanics, which includes the softening and damage behavior under tension is considered for the concrete material. The dynamic equilibrium equations of moti...
文摘目前水电站厂房的振动问题日益突出.根据当前水电站厂房振动研究和振动载荷特性识别的需要,总结了土木工程中几种常用的传感器优化布设准则,选择了BDA(backw ardde letion a lgorithm)方法;基于AN SY S-APDL二次开发技术,编写了适于水电站建筑物应用的Fortran程序;将传感器优化理论与方法应用于红石水电站厂房振动分析,建立了有限元数值模型及振动模态分析方法,对传感器布置进行了优化.发现选取前两阶振型参与优化布设已可满足要求,可为厂房的振动测量和动态识别提供较为可靠的数据.