Deep-sea sediment is extremely important in marine scientific research,such as that concerning marine geology and microbial communities.The research findings are closely related to the in-situ information of the sedim...Deep-sea sediment is extremely important in marine scientific research,such as that concerning marine geology and microbial communities.The research findings are closely related to the in-situ information of the sediment.One prerequisite for investigations of deep-sea sediment is providing sampling techniques capable of preventing distortion during recovery.As the fruit of such sampling techniques,samplers designed for obtaining sediment have become indispensable equipment,owing to their low cost,light weight,compactness,easy operation,and high adaptability to sea conditions.This paper introduces the research and application of typical deep-sea sediment samplers.Then,a representative sampler recently developed in China is analyzed.On this basis,a review and analysis is conducted regarding the key techniques of various deep-sea sediment samplers,including sealing,pressure and temperature retaining,low-disturbance sampling,and no-pressure drop transfer.Then,the shortcomings in the key techniques for deep-sea sediment sampling are identified.Finally,prospects for the future development of key techniques for deep-sea sediment sampling are proposed,from the perspectives of structural diversification,functional integration,intelligent operation,and high-fidelity samples.This paper summarizes the existing samplers in the context of the key techniques mentioned above,and can provide reference for the optimized design of samplers and development of key sampling techniques.展开更多
A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The si...A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor展开更多
The initial motivation of the lifting technique is to solve the H∞control problems. However, the conventional weighted H∞design does not meet the conditions required by lifting, so the result often leads to a misjud...The initial motivation of the lifting technique is to solve the H∞control problems. However, the conventional weighted H∞design does not meet the conditions required by lifting, so the result often leads to a misjudgement of the design. Two conditions required by using the lifting technique are presented based on the basic formulae of the lifting. It is pointed out that only the H∞disturbance attenuation problem with no weighting functions can meet these conditions, hence, the application of the lifting technique is quite limited.展开更多
This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid m...This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid machining process and measurement etc. as the design and sample product trial manufacture process of water meter new products are long in product development period, and low in product development efficiency in the present time.展开更多
The accumulator is used as a pressure compensation device to realize deep-sea microbe gastight sampling. Four key states of the accumulator are proposed to describe the pressure compensation process and a correspondin...The accumulator is used as a pressure compensation device to realize deep-sea microbe gastight sampling. Four key states of the accumulator are proposed to describe the pressure compensation process and a corresponding mathematical model is established to investigate the relationship between the results of pressure compensation and the parameters of the accumulator. Simulation results show that during the falling process of the sampler, the accumulator' s real opening pressure is greater than its precharge pressure; when the sampling depth is 6000 m and the accumulator' s precharge pressure is less than 30 MPa, to increase the accumulator' s precharge pressure can improve pressure compensation results obviously. Laboratory experiments at 60 MPa show that the acctunulator is an effective and reliable pressure compensation device for deep-sea microbe samplers, The success in sea trial at a depth of 2000 m in the South China Sea shows that the mathematical model and laboratory experiment results are reliable.展开更多
As an important guarantee for the prevention and control of animal diseases,veterinary drugs have important functions in improving animal production performance and product quality and maintaining ecological balance.T...As an important guarantee for the prevention and control of animal diseases,veterinary drugs have important functions in improving animal production performance and product quality and maintaining ecological balance.They are an important guarantee for the healthy development of animal husbandry,food safety and public health.However,the irrational use and abuse of veterinary drugs and feed pharmaceutical additives are widespread,causing harmful substances in animal foods and damage to human health,and threatening the sustainable development of the environment and animal husbandry as well.In order to ensure human health,it is urgent to develop a simple,rapid,high-sensitivity,high-throughput and low-cost veterinary drug residue detection technology.In this paper,the sample pretreatment methods and detection techniques for the analysis of veterinary drug residues in animal foods were reviewed.展开更多
Atmospheric radionuclide monitoring usually includes two sampling techniques, namely ultra-high volume aerosol samplers to collect at- mospheric particles by using filter media, and radioactive noble gas samplers to c...Atmospheric radionuclide monitoring usually includes two sampling techniques, namely ultra-high volume aerosol samplers to collect at- mospheric particles by using filter media, and radioactive noble gas samplers to collect atmospheric noble gas based on adsorption method. Atmos- pheric sampling techniques have been researched in Northwest Institute of Nuclear Technology since the Comprehensive Nuclear-Test-Ban Treaty (CTBT) was signed in 1996. Several ultra-high volume aerosol samplers and some types of radioactive xenon isotopes samplers had been devel- oped. For the aerosol sampler, the sampling flow is between 450 and 800 m3/h, with the minimum detectable concentration (MDC) of 131I less than 5 pBq/m3. For the xenon sampler, the sampling capacity of xenon is more than 4 ml per day, with MDC of l=Xe less than 0.25 mBq/m3. After the nuclear accident of Fukushima in 2011, monitoring of the atmospheric radionuclide was carried out for 3 months at Xi'an, and part of radionuclide was detected with concentrations hiaher than their backorounds in the period, includina 131I.134Cs. 137Cs and 133Xe.展开更多
In China, little information is known about the nutrient requirements of jackfruits and the traditional nutrient management usually depends on the experience. Therefore, in this study, an attempt was made to standardi...In China, little information is known about the nutrient requirements of jackfruits and the traditional nutrient management usually depends on the experience. Therefore, in this study, an attempt was made to standardize the leaf sampling technique and the suitable range of leaf nutrient concentrations for jackfruit (Artocarpus heterophyllus Lam.) nutrient status diagnosis. The sampling result was affected by canopy height, leaf age and time of sampling. Therefore, the three factors were studied. The results illustrated that the stability in level of nutrient concentrations was in 3 - 6 month-old leaves from the central part of the canopy. The most stable period was from April to May for leaf sampling. It was recommended that the stable intracanopy and stable period of nutrient concentrations could be used as the standards of leaf sampling technique. Based on the leaf sampling technique, the standard of leaf nutrient concentrations was summarized, and could be used as the standard of nutrient suitability evaluation.展开更多
When analyzing and evaluating risks in insurance, people are often confronted with the situation of incomplete information and insufficient data, which is known as a small-sample problem. In this paper, a one-dimensio...When analyzing and evaluating risks in insurance, people are often confronted with the situation of incomplete information and insufficient data, which is known as a small-sample problem. In this paper, a one-dimensional small-sample problem in insurance was investigated using the kernel density estimation method (KerM) and general limited information diffusion method (GIDM). In particular, MacCormack technique was applied to get the solutions of GIDM equations and then the optimal diffusion solution was acquired based on the two optimization principles. Finally, the analysis introduced in this paper was verified by treating some examples and satisfying results were obtained.展开更多
The lifting technique is now the most popular tool for dealing with sampled-data controlsystems. However, for the robust stability problem the system norm is not preserved by the liftingas expected. And the result is ...The lifting technique is now the most popular tool for dealing with sampled-data controlsystems. However, for the robust stability problem the system norm is not preserved by the liftingas expected. And the result is generally conservative under the small gain condition. The reason forthe norm di?erence by the lifting is that the state transition operator in the lifted system is zero inthis case. A new approach to the robust stability analysis is proposed. It is to use an equivalentdiscrete-time uncertainty to replace the continuous-time uncertainty. Then the general discretizedmethod can be used for the robust stability problem, and it is not conservative. Examples are givenin the paper.展开更多
In this paper, the problem of nonparametric estimation of finite population quantile function using multiplicative bias correction technique is considered. A robust estimator of the finite population quantile function...In this paper, the problem of nonparametric estimation of finite population quantile function using multiplicative bias correction technique is considered. A robust estimator of the finite population quantile function based on multiplicative bias correction is derived with the aid of a super population model. Most studies have concentrated on kernel smoothers in the estimation of regression functions. This technique has also been applied to various methods of non-parametric estimation of the finite population quantile already under review. A major problem with the use of nonparametric kernel-based regression over a finite interval, such as the estimation of finite population quantities, is bias at boundary points. By correcting the boundary problems associated with previous model-based estimators, the multiplicative bias corrected estimator produced better results in estimating the finite population quantile function. Furthermore, the asymptotic behavior of the proposed estimators </span><span style="font-family:Verdana;">is</span><span style="font-family:Verdana;"> presented</span><span style="font-family:Verdana;">. </span><span style="font-family:Verdana;">It is observed that the estimator is asymptotically unbiased and statistically consistent when certain conditions are satisfied. The simulation results show that the suggested estimator is quite well in terms of relative bias, mean squared error, and relative root mean error. As a result, the multiplicative bias corrected estimator is strongly suggested for survey sampling estimation of the finite population quantile function.展开更多
The laboratories in the bauxite processing industry are always under a heavy workload of sample collection, analysis, and compilation of the results. After size reduction from grinding mills, the samples of bauxite ar...The laboratories in the bauxite processing industry are always under a heavy workload of sample collection, analysis, and compilation of the results. After size reduction from grinding mills, the samples of bauxite are collected after intervals of 3 to 4 hours. Large bauxite processing industries producing 1 million tons of pure aluminium can have three grinding mills. Thus, the total number of samples to be tested in one day reaches a figure of 18 to 24. The sample of bauxite ore coming from the grinding mill is tested for its particle size and composition. For testing the composition, the bauxite ore sample is first prepared by fusing it with X-ray flux. Then the sample is sent for X-ray fluorescence analysis. Afterwards, the crucibles are washed in ultrasonic baths to be used for the next testing. The whole procedure takes about 2 - 3 hours. With a large number of samples reaching the laboratory, the chances of error in composition analysis increase. In this study, we have used a composite sampling methodology to reduce the number of samples reaching the laboratory without compromising their validity. The results of the average composition of fifteen samples were measured against composite samples. The mean of difference was calculated. The standard deviation and paired t-test values were evaluated against predetermined critical values obtained using a two-tailed test. It was found from the results that paired test-t values were much lower than the critical values thus validating the composition attained through composite sampling. The composite sampling approach not only reduced the number of samples but also the chemicals used in the laboratory. The objective of improved analytical protocol to reduce the number of samples reaching the laboratory was successfully achieved without compromising the quality of analytical results.展开更多
基金Supported by National Key Research and Development Program of China(Grant No.2016YFC0300502)Hunan Provincial Innovation Foundation For Postgraduate(Grant No.CX2018B658)+2 种基金National Natural Science Foundation of China(Grant Nos.51705145,517779092)Supported by Scientific Research Fund of Hunan Provincial Education Department(Grant No.18B205)Hunan Province Natural Science Foundation(Grant No.2019 JJ50182).
文摘Deep-sea sediment is extremely important in marine scientific research,such as that concerning marine geology and microbial communities.The research findings are closely related to the in-situ information of the sediment.One prerequisite for investigations of deep-sea sediment is providing sampling techniques capable of preventing distortion during recovery.As the fruit of such sampling techniques,samplers designed for obtaining sediment have become indispensable equipment,owing to their low cost,light weight,compactness,easy operation,and high adaptability to sea conditions.This paper introduces the research and application of typical deep-sea sediment samplers.Then,a representative sampler recently developed in China is analyzed.On this basis,a review and analysis is conducted regarding the key techniques of various deep-sea sediment samplers,including sealing,pressure and temperature retaining,low-disturbance sampling,and no-pressure drop transfer.Then,the shortcomings in the key techniques for deep-sea sediment sampling are identified.Finally,prospects for the future development of key techniques for deep-sea sediment sampling are proposed,from the perspectives of structural diversification,functional integration,intelligent operation,and high-fidelity samples.This paper summarizes the existing samplers in the context of the key techniques mentioned above,and can provide reference for the optimized design of samplers and development of key sampling techniques.
文摘A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor
基金Supported by the Harbin Engineering University Fund for Basic Projects (heuft06041)
文摘The initial motivation of the lifting technique is to solve the H∞control problems. However, the conventional weighted H∞design does not meet the conditions required by lifting, so the result often leads to a misjudgement of the design. Two conditions required by using the lifting technique are presented based on the basic formulae of the lifting. It is pointed out that only the H∞disturbance attenuation problem with no weighting functions can meet these conditions, hence, the application of the lifting technique is quite limited.
文摘This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid machining process and measurement etc. as the design and sample product trial manufacture process of water meter new products are long in product development period, and low in product development efficiency in the present time.
文摘The accumulator is used as a pressure compensation device to realize deep-sea microbe gastight sampling. Four key states of the accumulator are proposed to describe the pressure compensation process and a corresponding mathematical model is established to investigate the relationship between the results of pressure compensation and the parameters of the accumulator. Simulation results show that during the falling process of the sampler, the accumulator' s real opening pressure is greater than its precharge pressure; when the sampling depth is 6000 m and the accumulator' s precharge pressure is less than 30 MPa, to increase the accumulator' s precharge pressure can improve pressure compensation results obviously. Laboratory experiments at 60 MPa show that the acctunulator is an effective and reliable pressure compensation device for deep-sea microbe samplers, The success in sea trial at a depth of 2000 m in the South China Sea shows that the mathematical model and laboratory experiment results are reliable.
基金Supported by National Beef Industrial Technology System(CARS-38)Basic Science Research Fund(1610322018002)
文摘As an important guarantee for the prevention and control of animal diseases,veterinary drugs have important functions in improving animal production performance and product quality and maintaining ecological balance.They are an important guarantee for the healthy development of animal husbandry,food safety and public health.However,the irrational use and abuse of veterinary drugs and feed pharmaceutical additives are widespread,causing harmful substances in animal foods and damage to human health,and threatening the sustainable development of the environment and animal husbandry as well.In order to ensure human health,it is urgent to develop a simple,rapid,high-sensitivity,high-throughput and low-cost veterinary drug residue detection technology.In this paper,the sample pretreatment methods and detection techniques for the analysis of veterinary drug residues in animal foods were reviewed.
文摘Atmospheric radionuclide monitoring usually includes two sampling techniques, namely ultra-high volume aerosol samplers to collect at- mospheric particles by using filter media, and radioactive noble gas samplers to collect atmospheric noble gas based on adsorption method. Atmos- pheric sampling techniques have been researched in Northwest Institute of Nuclear Technology since the Comprehensive Nuclear-Test-Ban Treaty (CTBT) was signed in 1996. Several ultra-high volume aerosol samplers and some types of radioactive xenon isotopes samplers had been devel- oped. For the aerosol sampler, the sampling flow is between 450 and 800 m3/h, with the minimum detectable concentration (MDC) of 131I less than 5 pBq/m3. For the xenon sampler, the sampling capacity of xenon is more than 4 ml per day, with MDC of l=Xe less than 0.25 mBq/m3. After the nuclear accident of Fukushima in 2011, monitoring of the atmospheric radionuclide was carried out for 3 months at Xi'an, and part of radionuclide was detected with concentrations hiaher than their backorounds in the period, includina 131I.134Cs. 137Cs and 133Xe.
文摘In China, little information is known about the nutrient requirements of jackfruits and the traditional nutrient management usually depends on the experience. Therefore, in this study, an attempt was made to standardize the leaf sampling technique and the suitable range of leaf nutrient concentrations for jackfruit (Artocarpus heterophyllus Lam.) nutrient status diagnosis. The sampling result was affected by canopy height, leaf age and time of sampling. Therefore, the three factors were studied. The results illustrated that the stability in level of nutrient concentrations was in 3 - 6 month-old leaves from the central part of the canopy. The most stable period was from April to May for leaf sampling. It was recommended that the stable intracanopy and stable period of nutrient concentrations could be used as the standards of leaf sampling technique. Based on the leaf sampling technique, the standard of leaf nutrient concentrations was summarized, and could be used as the standard of nutrient suitability evaluation.
基金Project supported by the National Natural Science Foundation of China (Grant No.10271072)
文摘When analyzing and evaluating risks in insurance, people are often confronted with the situation of incomplete information and insufficient data, which is known as a small-sample problem. In this paper, a one-dimensional small-sample problem in insurance was investigated using the kernel density estimation method (KerM) and general limited information diffusion method (GIDM). In particular, MacCormack technique was applied to get the solutions of GIDM equations and then the optimal diffusion solution was acquired based on the two optimization principles. Finally, the analysis introduced in this paper was verified by treating some examples and satisfying results were obtained.
文摘The lifting technique is now the most popular tool for dealing with sampled-data controlsystems. However, for the robust stability problem the system norm is not preserved by the liftingas expected. And the result is generally conservative under the small gain condition. The reason forthe norm di?erence by the lifting is that the state transition operator in the lifted system is zero inthis case. A new approach to the robust stability analysis is proposed. It is to use an equivalentdiscrete-time uncertainty to replace the continuous-time uncertainty. Then the general discretizedmethod can be used for the robust stability problem, and it is not conservative. Examples are givenin the paper.
文摘In this paper, the problem of nonparametric estimation of finite population quantile function using multiplicative bias correction technique is considered. A robust estimator of the finite population quantile function based on multiplicative bias correction is derived with the aid of a super population model. Most studies have concentrated on kernel smoothers in the estimation of regression functions. This technique has also been applied to various methods of non-parametric estimation of the finite population quantile already under review. A major problem with the use of nonparametric kernel-based regression over a finite interval, such as the estimation of finite population quantities, is bias at boundary points. By correcting the boundary problems associated with previous model-based estimators, the multiplicative bias corrected estimator produced better results in estimating the finite population quantile function. Furthermore, the asymptotic behavior of the proposed estimators </span><span style="font-family:Verdana;">is</span><span style="font-family:Verdana;"> presented</span><span style="font-family:Verdana;">. </span><span style="font-family:Verdana;">It is observed that the estimator is asymptotically unbiased and statistically consistent when certain conditions are satisfied. The simulation results show that the suggested estimator is quite well in terms of relative bias, mean squared error, and relative root mean error. As a result, the multiplicative bias corrected estimator is strongly suggested for survey sampling estimation of the finite population quantile function.
文摘The laboratories in the bauxite processing industry are always under a heavy workload of sample collection, analysis, and compilation of the results. After size reduction from grinding mills, the samples of bauxite are collected after intervals of 3 to 4 hours. Large bauxite processing industries producing 1 million tons of pure aluminium can have three grinding mills. Thus, the total number of samples to be tested in one day reaches a figure of 18 to 24. The sample of bauxite ore coming from the grinding mill is tested for its particle size and composition. For testing the composition, the bauxite ore sample is first prepared by fusing it with X-ray flux. Then the sample is sent for X-ray fluorescence analysis. Afterwards, the crucibles are washed in ultrasonic baths to be used for the next testing. The whole procedure takes about 2 - 3 hours. With a large number of samples reaching the laboratory, the chances of error in composition analysis increase. In this study, we have used a composite sampling methodology to reduce the number of samples reaching the laboratory without compromising their validity. The results of the average composition of fifteen samples were measured against composite samples. The mean of difference was calculated. The standard deviation and paired t-test values were evaluated against predetermined critical values obtained using a two-tailed test. It was found from the results that paired test-t values were much lower than the critical values thus validating the composition attained through composite sampling. The composite sampling approach not only reduced the number of samples but also the chemicals used in the laboratory. The objective of improved analytical protocol to reduce the number of samples reaching the laboratory was successfully achieved without compromising the quality of analytical results.