<b>Introduction:</b> Digital models showed promising results for orthodontic diagnosis and treatment planning. Digital models can be obtained from alginate impressions as well as direct intra-oral scanners...<b>Introduction:</b> Digital models showed promising results for orthodontic diagnosis and treatment planning. Digital models can be obtained from alginate impressions as well as direct intra-oral scanners. Studies assessing the accuracy of digital models have shown digital models to be valid, clinically acceptable, and more quickly obtainable. With the advent of new scanners with better scanning technology researches are necessary to evaluate their accuracy and reliability. <b>Aim of Study:</b> To evaluate the diagnostic accuracy of 3D digital models obtained through intraoral and extraoral scanning modalities to the reference gold standard plaster model. <b>Material & Methods:</b> Twenty-four adult male and female subjects were randomly selected for this study. The intraoral scanners evaluated in this study were Sirona (CEREC Omnicam) and 3 shape (TRIOS 3), while the laboratory scanners used were Sirona (inEos X5), and 3 shape (D850). Intra-oral scanning of the subjects and extra-oral scanning of their alginate impressions, plaster models of the alginate impression, rubber base impression, and plaster model of their rubber base impression were done. Linear dental measurements included intermolar width, interpremolar width, intercanine width, mesiodistal width of the 1<sup>st</sup> permanent molar, 1<sup>st</sup> premolar, canine and central incisor and arch width. All data were collected, tabulated and subjected to statistical analysis. <b>Results:</b> Small differences between the plaster and digital models were observed. Intra-observer reliability analysis for 14 out of the 16 measurements showed that all variables exhibited good to excellent reliability. <b>Conclusions: </b>There was no difference between the digitization using the intraoral scanner or the laboratory scanner. The most accurate digitization technique was the 3 Shape laboratory scanner of the cast of the alginate impression. The inEos X5 showed the highest error of digitization of the alginate and rubber base impressions.展开更多
In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structur...In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs.展开更多
Objective To validate the performance of Mycob. T Stainer and Scanner(MTSS) for detecting acid-fast bacilli(AFB). Methods A total of 3,816 sputum samples from 1,515 tuberculosis(TB) suspects were tested at the Anhui P...Objective To validate the performance of Mycob. T Stainer and Scanner(MTSS) for detecting acid-fast bacilli(AFB). Methods A total of 3,816 sputum samples from 1,515 tuberculosis(TB) suspects were tested at the Anhui Provincial Chest Hospital and the Linyi People's Hospital from April-August, 2016. Each specimen was placed on two smear slides. One slide was stained by the ziehl-neelsen(ZN) method to be read by conventional microscopy(CM). The other slide was stained and scanned by MTSS. All specimens were decontaminated with 4% NaO H, and then inoculated into solid culture. The performance of MTSS was assessed. Results MTSS produced higher average positivity rate(27.96%) as compared with the CM(26.83%). The overall sensitivity and specificity of MTSS were 78.9% and 93.9%, respectively. The sensitivity and specificity of CM was 77.4% and 95.0%, respectively. Conclusion MTSS exhibited a favorable performance in the detection of AFB. It may be an alternative to CM for screening TB.展开更多
Aluminum welding using a hybrid system with a laser and scanner welding head was performed under various welding conditions to verify the feasibility of applying an aluminum alloy to a car body.The experimental materi...Aluminum welding using a hybrid system with a laser and scanner welding head was performed under various welding conditions to verify the feasibility of applying an aluminum alloy to a car body.The experimental material was 5J32 aluminum alloy,and the laser power,welding speed,and laser incidence angle were used as the control variables.The weld bead shape and the tensile shear strength were evaluated in order to understand the aluminum lap joint weld characteristics.Analysis of variance (ANOVA) was conducted to identify the effect of the process variables on the tensile shear strength.Tensile strength estimation models using three different regression models were also suggested.The input variables were the laser power,welding speed,and laser incidence angle,and the output was the tensile shear strength.Among the models,the second-order polynomial estimation model had the best estimation performance,and the average error rate of this model was 0.058.展开更多
文摘<b>Introduction:</b> Digital models showed promising results for orthodontic diagnosis and treatment planning. Digital models can be obtained from alginate impressions as well as direct intra-oral scanners. Studies assessing the accuracy of digital models have shown digital models to be valid, clinically acceptable, and more quickly obtainable. With the advent of new scanners with better scanning technology researches are necessary to evaluate their accuracy and reliability. <b>Aim of Study:</b> To evaluate the diagnostic accuracy of 3D digital models obtained through intraoral and extraoral scanning modalities to the reference gold standard plaster model. <b>Material & Methods:</b> Twenty-four adult male and female subjects were randomly selected for this study. The intraoral scanners evaluated in this study were Sirona (CEREC Omnicam) and 3 shape (TRIOS 3), while the laboratory scanners used were Sirona (inEos X5), and 3 shape (D850). Intra-oral scanning of the subjects and extra-oral scanning of their alginate impressions, plaster models of the alginate impression, rubber base impression, and plaster model of their rubber base impression were done. Linear dental measurements included intermolar width, interpremolar width, intercanine width, mesiodistal width of the 1<sup>st</sup> permanent molar, 1<sup>st</sup> premolar, canine and central incisor and arch width. All data were collected, tabulated and subjected to statistical analysis. <b>Results:</b> Small differences between the plaster and digital models were observed. Intra-observer reliability analysis for 14 out of the 16 measurements showed that all variables exhibited good to excellent reliability. <b>Conclusions: </b>There was no difference between the digitization using the intraoral scanner or the laboratory scanner. The most accurate digitization technique was the 3 Shape laboratory scanner of the cast of the alginate impression. The inEos X5 showed the highest error of digitization of the alginate and rubber base impressions.
文摘In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs.
基金supported by Chinese Anti-Tuberculosis Association[042016]
文摘Objective To validate the performance of Mycob. T Stainer and Scanner(MTSS) for detecting acid-fast bacilli(AFB). Methods A total of 3,816 sputum samples from 1,515 tuberculosis(TB) suspects were tested at the Anhui Provincial Chest Hospital and the Linyi People's Hospital from April-August, 2016. Each specimen was placed on two smear slides. One slide was stained by the ziehl-neelsen(ZN) method to be read by conventional microscopy(CM). The other slide was stained and scanned by MTSS. All specimens were decontaminated with 4% NaO H, and then inoculated into solid culture. The performance of MTSS was assessed. Results MTSS produced higher average positivity rate(27.96%) as compared with the CM(26.83%). The overall sensitivity and specificity of MTSS were 78.9% and 93.9%, respectively. The sensitivity and specificity of CM was 77.4% and 95.0%, respectively. Conclusion MTSS exhibited a favorable performance in the detection of AFB. It may be an alternative to CM for screening TB.
基金Project(KRF-2010-0003259)supported by the Korea Research Foundation Grant funded by the Korean Government
文摘Aluminum welding using a hybrid system with a laser and scanner welding head was performed under various welding conditions to verify the feasibility of applying an aluminum alloy to a car body.The experimental material was 5J32 aluminum alloy,and the laser power,welding speed,and laser incidence angle were used as the control variables.The weld bead shape and the tensile shear strength were evaluated in order to understand the aluminum lap joint weld characteristics.Analysis of variance (ANOVA) was conducted to identify the effect of the process variables on the tensile shear strength.Tensile strength estimation models using three different regression models were also suggested.The input variables were the laser power,welding speed,and laser incidence angle,and the output was the tensile shear strength.Among the models,the second-order polynomial estimation model had the best estimation performance,and the average error rate of this model was 0.058.