期刊文献+
共找到449篇文章
< 1 2 23 >
每页显示 20 50 100
Electronic Scanning of Uterine Endometrium in Postpartum Cow
1
作者 TIANWen-ru HEJian-bin 《Journal of Northeast Agricultural University(English Edition)》 CAS 2000年第2期118-124,共7页
Two postpartum cows were used to study the ultrastructural changes of uterine endometrium by using scanning electron microscope.The results showed that the process of repair of uterine endometrium after calving was de... Two postpartum cows were used to study the ultrastructural changes of uterine endometrium by using scanning electron microscope.The results showed that the process of repair of uterine endometrium after calving was demonstrated by scanning electron microscope through a series of endometrium biopsy.Some part of the endometrium was damaged after calving and its adjacent endometrium cells became necrosis and exfoliated during the first 7 days post-partum;the cilium and microvillus of the epithelial cell in the undamaged area of the endometrium disappeared.By 26 days postpartum the damaged area reduced and the cilium and microvillus increased in their numbers.The damaged tissues were all repaired by day 60 postpartum. 展开更多
关键词 postpartum cow uterine involution scanning electron microscope
下载PDF
Scanning Electron Microscopy of Antennae of Aphidoletes aphidimyza (Diptera: Cecidomyiidae) 被引量:6
2
作者 张洁 杨茂发 《Zoological Research》 CAS CSCD 北大核心 2008年第1期108-112,共5页
The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the ... The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the female was 1050μm. Six types of sensillae on the antenna were observed, viz. chaetica (Ch), trichoidea (Tr), basiconica (Ba), cavity (Ca), styloid (St) and circumfila (Ci) on the antennae of A. aphidimyza. Sensillae Ch had a long external-process, with a base surrounded by membranous sockets and a length of about 67.5 μm. Sensillae Tr were distally curved and inserted into a depression, 61.0μm long. Sensillae Ba were peg-like and 4.7μm long on the antennae. Sensillae Ca were pit-like in appearance and the diameter of the pit was 1.2μm. Sensilla St was found on the second sub-segment flagellum of the male antennae. The length of the sensilla was about 21 μm and the diameter was 1.5μm. The circurnfila, which are a unique type of sensilla found only on cecidomyiid antennae, formed loops around each of the antennal sub-segments, and were attached to the surface by a series of stalks. Sensilla St was only present on male antenna. The number of Ba and Tr was almost the same in both sexes. There were more Sensilla Ca on the male antenna than on the female, while there was more Ch on the female. 展开更多
关键词 Aphidoletes aphidimyza scanning electron microscopy ANTENNA Sensillae ULTRASTRUCTURE
下载PDF
Obsevation for Epidermal Ultrastructure of Nostoc sphaeroides Kutzing under Scanning Electron Microscope 被引量:1
3
作者 李莉 《Agricultural Science & Technology》 CAS 2009年第1期1-3,共3页
[Objective]The experiment aimed to explore a new way for observing surface structure of Nostoc sphaeroides Kutzing. [Method] The scanning electron microscope was used to observe the epidermal ultrastructure of wild an... [Objective]The experiment aimed to explore a new way for observing surface structure of Nostoc sphaeroides Kutzing. [Method] The scanning electron microscope was used to observe the epidermal ultrastructure of wild and cultured Nostoc sphaeroides Kutzing. [ Result] The epidermis of wild and cultured Nostoc sphaeroides Kutzing showed mixture structure of fibril colloid which was reticular arranged. The difference between wild and cultured Nostoc sphaeroides Kutzing was that the outer epidermis of cultured Nostoc sphaeroides Kutzing had trichome distribution but the wild Nostoc sphaeroides Kutzing did not has such distribution. The obsevation results of under smaller than 10 μm by scanning electron microscope was touched thick and showed many folds and distortions. [ Conclusion] The scanning electron microscope was an effective way to study development of Nostoc sphaeroides Kutzing colony and it was worth popularizing. 展开更多
关键词 Nostoc sphaeroides Kutzing Epidermal ultrastructure scanning electron microscope
下载PDF
Observation of Helicotylenchus digonicus by Scanning Electron Microscope
4
作者 郑炜 《Plant Diseases and Pests》 CAS 2011年第5期32-33,37,共3页
[ Objective] The paper was to observe Helicotylenchus digonicus by scanning electron microscope (SEM). [ Method ] H. digonicus collected from Changxing of Zhejiang Province was observed under scanning electron micro... [ Objective] The paper was to observe Helicotylenchus digonicus by scanning electron microscope (SEM). [ Method ] H. digonicus collected from Changxing of Zhejiang Province was observed under scanning electron microscope, and its morphological structure was confmned under optical microscope. [ Resuit]The nematode specimens fixed by glutaraldehyde and osmium tetroxide and prepared by critical point drying were unmodified and unshrinkable with clear mor- phological structure, which could be scanned very well by scanning electron microscope. [ Conclusion ] The study provided reference for study and control of H. digonicus. 展开更多
关键词 Helicotylenchus d^gonicus Morphological structure scanning electron microscope China
下载PDF
Scanning Electron Microscopic Observation on Morphologic Characteristics of Sperms in Uremic Patients
5
作者 Long-gen XU Shi-fang SHI +6 位作者 Hai-zhen ZHONG Xiao-feng HUANG Xiao-ping QI Qi-zhe SONG Xin-hong WANG Li YAN Zong-fu SHAO 《Journal of Reproduction and Contraception》 CAS 2004年第4期227-232,共6页
To observe the morphologic characteristics of spermatozoon ultramicroscopic structure in uremic subjects.Method Semen sample from lO patients with uremia and 5 healthy men were observed under light microscope and scan... To observe the morphologic characteristics of spermatozoon ultramicroscopic structure in uremic subjects.Method Semen sample from lO patients with uremia and 5 healthy men were observed under light microscope and scanning electronic microscope.Results Abnormalities were found in sperms of uremic patients either in the sperm head (acrosome, acrosomic deficit, nuclear abnormality, pointed head, headless and double head of spermatozoon), neck (rupture, separation and enlargement), or tail (mitochondrial swelling, mitochondrial deficit, tailless, double tail, short tail and curled tail); whereas none of the above-mentioned abnormalities was observed in healthy men. Conclusion Sperms of uremic patients had many morphologic and structural abnormalities in the head, neck and tail. 展开更多
关键词 UREMIA SPERMATOZOON scanning electronic microscope
下载PDF
Surface characteristics analysis of fractures induced by supercritical CO_(2)and water through three-dimensional scanning and scanning electron micrography 被引量:7
6
作者 Hao Chen Yi Hu +4 位作者 Jiawei Liu Feng Liu Zheng Liu Yong Kang Xiaochuan Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2021年第5期1047-1058,共12页
Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyze... Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyzed the fracture surface characteristics induced by supercritical carbon dioxide(SC-CO_(2))and water in open-hole and perforation completion conditions under triaxial stresses.A simple calculation method was proposed to quantitatively analyze the fracture surface area and roughness in macro-level based on three-dimensional(3D)scanning data.In micro-level,scanning electron micrograph(SEM)was used to analyze the features of fracture surface.The results showed that the surface area of the induced fracture increases with perforation angle for both SC-CO_(2)and water fracturing,and the surface area of SC-CO_(2)-induced fracture is 6.49%e58.57%larger than that of water-induced fracture.The fractal dimension and surface roughness of water-induced fractures increase with the increase in perforation angle,while those of SC-CO_(2)-induced fractures decrease with the increasing perforation angle.A considerable number of microcracks and particle peeling pits can be observed on SC-CO_(2)-induced fracture surface while there are more flat particle surfaces in water-induced fracture surface through SEM images,indicating that fractures tend to propagate along the boundary of the particle for SC-CO_(2)fracturing while water-induced fractures prefer to cut through particles.These findings are of great significance for analyzing fracture mechanism and evaluating fracturing stimulation performance. 展开更多
关键词 Supercritical carbon dioxide(SC-CO_(2))fracturing Quantitative characterization of surface features Surface roughness and fractal dimension Three-dimensional(3D)scanning scanning electron micrograph(SEM)
下载PDF
Chalkiness Characters and Scanning Electron Microscope Observation of Rice Grain Endosperm of Japonica Varieties in Southern Henan 被引量:5
7
作者 Bo PENG Yanfang SUN +8 位作者 Dongyan KONG Ruihua PANG Xiaohua SONG Huilong LI Jintao LI Qiying ZHOU Qiu HAN Shizhi SONG Hongyu YUAN 《Asian Agricultural Research》 2017年第3期80-85,共6页
Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important ... Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important for us to investigate the relation of the chalkiness formation and the development of endosperm structure and starch granule of different rice varieties. Here,we have investigated the chalkiness characters such as chalkiness rate,chalkiness degree and chalkiness area in 15 japonica rice varieties from southern Henan. Furthermore,the endosperm structure and starch granules of rice grain were also observed with scanning electron microscope. The results showed that the 15 japonica varieties have a significantly linear relationship between the chalkiness rate and chalkiness degree. Among the varieties,the biggest difference is the chalkiness rate,the second is the chalkiness area,and the last is the chalkiness degree. Moreover,there is a certain correlation between the distribution of starch granules,the arrangement of endosperm cells and the occurrence of grain chalkiness in the different rice varieties. For the same variety,the starch granules of chalky and non-chalky grains have obvious difference,while the starch granules from the transparent part of chalky rice and non-chalky rice do not have significant difference. The results would provide useful references for the improvement of grain quality in rice. 展开更多
关键词 CHALKINESS scanning electron microscope Japonica rice Starch granule ENDOSPERM
下载PDF
Characterization of a nano line width reference material based on metrological scanning electron microscope 被引量:2
8
作者 Fang Wang Yushu Shi +4 位作者 Wei Li Xiao Deng Xinbin Cheng Shu Zhang Xixi Yu 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第5期203-211,共9页
The line width(often synonymously used for critical dimension,CD)is a crucial parameter in integrated circuits.To accurately control CD values in manufacturing,a reasonable CD reference material is required to calibra... The line width(often synonymously used for critical dimension,CD)is a crucial parameter in integrated circuits.To accurately control CD values in manufacturing,a reasonable CD reference material is required to calibrate the corresponding instruments.We develop a new reference material with nominal CDs of 160 nm,80 nm,and 40 nm.The line features are investigated based on the metrological scanning electron microscope which is developed by the National Institute of Metrology(NIM)in China.Also,we propose a new characterization method for the precise measurement of CD values.After filtering and leveling the intensity profiles,the line features are characterized by the combination model of the Gaussian and Lorentz functions.The left and right edges of CD are automatically extracted with the profile decomposition and k-means algorithm.Then the width of the two edges at the half intensity position is regarded as the standard CD value.Finally,the measurement results are evaluated in terms of the sample,instrument,algorithm,and repeatability.The experiments indicate efficiency of the proposed method which can be easily applied in practice to accurately characterize CDs. 展开更多
关键词 critical dimension line width metrological scanning electron microscopy TRACEABILITY
下载PDF
Scanning transmission electron microscopy: A review of high angle annular dark field and annular bright field imaging and applications in lithium-ion batteries 被引量:2
9
作者 Yu-Xin Tong Qing-Hua Zhang Lin Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期23-34,共12页
Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. H... Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. High angle annular dark field(HAADF) and annular bright field(ABF) imaging of the aberration-corrected STEM are widely used due to their high-resolution capabilities and easily interpretable image contrasts. However, HAADF mode of the STEM is still limited in detecting light elements due to the weak electron-scattering power. ABF mode of the STEM could detect light and heavy elements simultaneously, providing unprecedented opportunities for probing unknown structures of materials. Atomiclevel structure investigation of materials has been achieved by means of these imaging modes, which is invaluable in many fields for either improving properties of materials or developing new materials. This paper aims to provide a introduction of HAADF and ABF imaging techniques and reviews their applications in characterization of cathode materials, study of electrochemical reaction mechanisms, and exploring the effective design of lithium-ion batteries(LIBs). The future prospects of the STEM are also discussed. 展开更多
关键词 scanning transmission electron microscopy high angle annular dark field annular bright field lithium-ion batteries
下载PDF
Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study 被引量:5
10
作者 Jun Sang Yoo Seok-Woo Chang +8 位作者 So Ram Oh Hiran Perinpanayagam Sang-Min Lim Yeon-Jee Yoo Yeo-Rok Oh Sang-Bin Woo Seung-Hyun Han Qiang Zhu Kee-Yeon Kum 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第4期227-232,共6页
The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted huma... The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted human premolars(n560) were instrumented to an apical size #50/0.06 using ProF ile and treated as follows: Group 1(n510) was filled with phosphate buffered saline(PBS); Group 2(n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3(n520) was obturated orthograde with a paste of OrthoM TA(BioM TA, Seoul, Korea) and PBS; and Group 4(n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoM TA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material(IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoM TA-filled roots(Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots(Group 4). Therefore, the orthograde obturation of root canals with OrthoM TA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. 展开更多
关键词 bacterial entombment intratubular mineralization orthograde canal obturation scanning electron microscopy tag-like structure
下载PDF
Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy 被引量:1
11
作者 Melike Balikoglu-Yilmaz Tolga Yilmaz +4 位作者 Sule Cetinel Umit Taskin Ayse Banu Esen Muhittin Taskapili Timur Kose 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期534-540,共7页
AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidi... AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidiode laser.METHODS:This prospective study included 30consecutive patients with nasolacrimal duct obstruction who underwent EXT-,EN-,or TC-DCR.Thirty removed lacrimal stent fragments and conjunctival samples were cultured.The lacrimal stent biofilms were examined by scanning electron microscopy(SEM).RESULTS:Eleven(36.7%)of the 30 lacrimal stent cultures were positive for aerobic bacteria(most commonly Staphylococcus epidermidis and Pseudomonas aeruginosa).However anaerobic bacteria and fungi were not identified in the lacrimal stent cultures.Twenty-seven(90%)patients had biofilmpositive lacrimal stents.The conjunctival culture positivity after the DCR,biofilm positivity on stents,the grade of biofilm colonization,and the presence of mucus and coccoid and rod-shaped organisms did not significantly differ between any of the groups(P】0.05).However,a significant difference was found when the SEM results were compared to the results of the lacrimal stent and conjunctival cultures(P【0.001).CONCLUSION:Type of dacryocystorhinostomy(DCR)surgery did not affect the biofilm colonization of the lacrimal stents.SEM also appears to be more precise than microbiological culture for evaluating the presence of biofilms on lacrimal stents. 展开更多
关键词 biofilms nasolacrimal duct obstruction EPIPHORA DACRYOCYSTITIS scanning electron microscopy
下载PDF
Retrieving analog images from a scanning electron microscopewith a synchronous data acquisition method 被引量:1
12
作者 BAI Jiang-hua 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第4期329-334,共6页
In this work,an old scanning electron microscope(SEM)is refurbished to enhance its image processing capability.How to digitally sample and process an analog image is also presented.An NI PCI-6259 multiple input/output... In this work,an old scanning electron microscope(SEM)is refurbished to enhance its image processing capability.How to digitally sample and process an analog image is also presented.An NI PCI-6259 multiple input/output data acquisition(DAQ)board is used to acquire signals originally being sent to an analog display,and then convert the signals into a digital image.Two output channels are used for raster scan of the horizontal and verticle axes of the image buffer,while one input channel is used to read the brightness signals at various coordinate points.Synchronous method is used to maximize the DAQ speed.Finally,the digitally buffered images are read out to display and saved in a hard drive.The hardware and software designs of this work are explained in great detail,which can serve as a very good example for fast synchronous DAQ,advanced virtual instrument design and structural driver programming with LabVIEW. 展开更多
关键词 scanning electron microscope analog image display raster scan synchronous data acquisiotion(DAQ) LABVIEW
下载PDF
A double toroidal analyzer for scanning probe electron energy spectrometer 被引量:1
13
作者 徐春凯 张盼科 +1 位作者 郦盟 陈向军 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第7期183-187,共5页
An ultra-high vacuum (UHV) compatible electron spectrometer employing a double toroidal analyzer has been de- veloped. It is designed to be combined with a custom-made scanning tunneling microscope (STM) to study ... An ultra-high vacuum (UHV) compatible electron spectrometer employing a double toroidal analyzer has been de- veloped. It is designed to be combined with a custom-made scanning tunneling microscope (STM) to study the spatially localized electron energy spectrum on a surface. A tip-sample system composed of a piezo-driven field-emission tungsten tip and a sample of highly ordered pyrolytic graphite (HOPG) is employed to test the performance of the spectrometer. Two-dimensional images of the energy-resolved and angle-dispersed electrons backscattered from the surface of HOPG are obtained, the performance is optimized and the spectrometer is calibrated. A complete electron energy loss spectrum covering the elastic peak to the secondary electron peaks for the HOPG surface, acquired at a tip voltage of -140 V and a sample current of 0.5 pA, is presented, demonstrating the viability of the spectrometer. 展开更多
关键词 double toroidal analyzer scanning probe electron energy spectroscopy electron energy loss spec-troscopy secondary electron emission spectroscopy
下载PDF
Scanning electron microscopy coupled with energydispersive X-ray spectrometry for quick detection of sulfuroxidizing bacteria in environmental water samples 被引量:1
14
作者 SUN Chengjun JIANG Fenghua +5 位作者 GAO Wei LI Xiaoyun YU Yanzhen YIN Xiaofei WANG Yong DING Haibing 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2017年第1期185-191,共7页
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee... Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples. 展开更多
关键词 sulfur bacteria energy-dispersive X-ray spectrometry scanning electron microscopy bacteria detection environmental water samples 16S rRNA sequencing
下载PDF
Study of a Novel Small Caliber Vascular Graft in a Canine Model with Optical and Scanning Electron Microscopy 被引量:1
15
作者 XU Yi-min QI Song-tao SHI Xiao-feng ZENG Shao-wen LI Wei-qiu HUANG Guang-long ZHUANG Bing-rong 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第1期22-32,共11页
A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography w... A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography was performed at the first week post-operation, and angiography was then administered to 9 grafts at 4th week, 12th week and 24th week respectively to monitor the graft pantency and blood flow characteristics. Vascular samples containing the grafts were collected at 1st week, 8th week, 12th week and 24th week after implantation. Morphological changes of the grafts were observed by optical and scanning electron microscopic (SEM) studies and compared with that of the original prosthesis and the normal host vessel. All grafts were patent throughout the experiment except one graft. Histopathology and SEM demonstrated both a nearly complete inner capsule of varied thickness lining the graft luminal surface and connective tissue adventitia formation at one-week post-operation. The neointima became confluent at 8 weeks and then compact but had no signs of hyperplasia up to 12 weeks; meanwhile on the neointimal surface newly grown endothelial-like cells were migrating from the stoma to the middle portion. The grafts also illustrated endothelialization in many “islands” in the mid-segment luminal surface of the grafts. In addition, the closer distance the cells towards the stoma were, the more morphological similarity the cells with the normal endothelial were. Taken together, the biological vascular graft remained patent for 24 weeks as a carotid prosthesis, characterized by the early and complete neointima formation plus endothelialization starting before 12 weeks post grafting. Therefore, the graft seems suitable for reconstruction of vascular lesions in dogs. Further studies may be carried out to extend the graft application for the clinical use. 展开更多
关键词 DOG Surgical implantation Common carotid artery Biological vascular graft RECONSTRUCTION HISTOPATHOLOGY scanning electron microscopy ENDOTHELIALIZATION
下载PDF
Scanning Electron Acoustic Microscopy of GaInAsSb by Metalorganic Chemical Vapor Deposition
16
作者 李树玮 金亿鑫 +3 位作者 周天明 张宝林 宁永强 蒋红 《Rare Metals》 SCIE EI CAS CSCD 1996年第2期101-105,共5页
Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and... Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing. 展开更多
关键词 scanning electron acoustic microscopy Electron-acoustic imaging GAINASSB MOCVD
下载PDF
Gill surface architecture of mullet, Mugil soiuy (Basilewsky) : A scanning electron microscope study
17
作者 Wang LiangchenDepartment of Biology Nankai University, Tianjin, ChinaGuo ShuhuaTest and Computation Centre Nankai University, Tianjing, China 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1989年第4期606-609,共4页
Specimens of Mugil soiuy were collected from the coastal waters of Bohai Sea in Tianjin. The gillfilaments were cut with fine scissors and soaked for 24h in a fixative consisting of 2.5% glutaralde-hyde in 0.1 mol lph... Specimens of Mugil soiuy were collected from the coastal waters of Bohai Sea in Tianjin. The gillfilaments were cut with fine scissors and soaked for 24h in a fixative consisting of 2.5% glutaralde-hyde in 0.1 mol lphosporic acid buffer. After three washes in a buffer solution the tissue was fixedin a mixture of 1% osmium tetraoxide at 4℃ for 1h. The tissue was dehydrated in graded ethandethanols and dried. The tissue was examined and photographed with an SEM at an accelerating voltage 展开更多
关键词 A scanning electron microscope study Basilewsky Gill surface architecture of mullet
下载PDF
MORPHOLOGICAL CHANGES OF RATS MUSCLES AT VARIOUS POSTMORTEM INTERVALS BY SCANNING ELECTRON MICROSCOPY
18
作者 廖志钢 易旭夫 +1 位作者 肖飞 彭雪梅 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第4期255-258,共4页
The aim of this study was to observe the morphological changes of muscle in the process of rigor mortis. The quadriceps of 40 rats at various postmortem intervals were observed under the... The aim of this study was to observe the morphological changes of muscle in the process of rigor mortis. The quadriceps of 40 rats at various postmortem intervals were observed under the scanning electron microscope(SEM) and the light microscope by phosphotungstic acid haematoxylin(PTAH) stain. The results showed that the striations of muscle were blurred within 4 h, but they became apparent from 6 h to 24 h after death. The authors suggest that this phenomenon be associated with the increased resistance of muscle against the postmortal changes. The observations by scanning electron microscopy and light microscopy have revealed that the muscles do contract in the process of rigor mortis because the distance between two Z lines shortens and the I band narrows, compared with those in anaesthetised animals. The basic biochemical process for the formation of rigor mortis is the same as that of muscle contraction except that the former happens postmortem and the latter antemortem. 展开更多
关键词 rigor mortis muscle contraction scanning electron microscopy
下载PDF
Scanning Electron Microscopy(SEM) Observations of Antennal Sensilla of Chrysopa pallens Rambur(Neuroptera:Chrysopidae)
19
作者 Wang Juan Chen Hongyin +3 位作者 Wang Mengqing Liu Chenxi Zhang Haiping Zhang Lisheng 《Plant Diseases and Pests》 CAS 2017年第2期1-4,19,共5页
[Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The ... [Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The submicroscopic structure of antennal sensilla of C. pallens was examined using scanning electron microscopy. [Results]Antennae of female and male C. pallens were linear in shape and( 1. 52 ± 0. 08) and( 1. 58 ± 0. 23) cm in length,respectively. The scape and pedicel were composed of single sub-segment,while the flagellum consisted of 116 sub-segments,on which most sensilla distributed. The flagella of female and male antennae were( 1. 44 ± 0. 04) and( 1. 47 ± 0. 13) cm in length,respectively. Nine morphological sensilla types were recorded in both sexes,including four types of highly abundant and widely distributed sensilla trichodea( ST Ⅰ,ST Ⅱ,ST Ⅲ and ST Ⅳ),three types of sensilla basiconica( SB Ⅰ,SB Ⅱ,and SB Ⅲ),and one of each type of sensilla chaetica and B9 hm bristles. Although the shape,structure,numbers,and distribution of antennae of females and males were basically similar,major differences were recorded between the sexes in the length of some sensilla types. Both the ST Ⅲ and SB Ⅰ in female adults were significantly longer than that in male ones. Notably,SB Ⅱ was found only in female. [Conclusions]The paper laid a foundation for revealing the relationship between smell and behavior,playing a crucial role in promoting the important biological control effect of C. pallens in farmland ecological system. 展开更多
关键词 Chrysopa pallens ANTENNA SENSILLA ULTRASTRUCTURE scanning electron microscopy
下载PDF
Electron Energy Spectroscopic Mapping of Surface Plasmon by Parallel Scanning Method
20
作者 Zhongfeng Li Tuo Liu +1 位作者 Chunkai Xu Xiangjun Chen 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2022年第3期537-541,I0003,共6页
In this work,electron energy spectroscopic mapping of surface plasmon of Ag nanostructures on highly oriented pyrolytic graphite is reported.Benefitting from the angular dispersive feature of the present scanning prob... In this work,electron energy spectroscopic mapping of surface plasmon of Ag nanostructures on highly oriented pyrolytic graphite is reported.Benefitting from the angular dispersive feature of the present scanning probe electron energy spectrometer,a multi-channel detection mode is developed.By scanning along one direction,the two-dimensional intensity distribution of Ag surface plasmon excitation due to the collision of electron emitted from the tip can be obtained in parallel.The spectroscopic spatial resolution is determined to be around 80 nm. 展开更多
关键词 scanning probe electron energy spectroscopy Surface plasmon Spectroscopic mapping
下载PDF
上一页 1 2 23 下一页 到第
使用帮助 返回顶部