The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange...The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.展开更多
Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera...Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.展开更多
This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilizat...This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period.展开更多
Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts i...Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts in U.S.office buildings of multiple alternative ventilation strategies that combined:economizing,demand controlled ventilation(DCV),supply air temperature reset(SR),and/or a doubled ventilation rate.We used energy simulations in a Monte Carlo analysis,sampling 17 building inputs and varying locations to match the climate zone distribution of the U.S.office stock.Results indicated the possibility for significant savings compared to a baseline that ventilated constantly at a minimum rate in both a small office type with a constant air volume(CAV) HVAC system and a medium office type with a variable air volume(VAV) system.In 95%of instances,HVAC source energy savings were 5-25%in the small-CAV office(median:11%) and 6-42%in the medium-VAV office(median:27%).In the small-CAV office,DCV typically saved the most energy,usually from heating,and heating degree days and occupant density were decisive influences.In the medium-VAV office,economizing and SR were most important,DCV usually only had minor impacts,and zone temperature setpoints,along with climate indicators,were the critical influences.Other than infiltration,envelope characteristics did not strongly influence energy impacts.The untapped primary energy savings of alternative ventilation strategies over the 74%of U.S.office floorspace reasonably represented by our modeling was estimated at 36 TWh per year,with an annual value of U.S.$ 1.25 billion.展开更多
A study on performances of different ventilation schemes provided by vertical and horizontal uni-directional air flow was carried out in a standard orthopaedic operating theatre (OT). Starting from our previous studie...A study on performances of different ventilation schemes provided by vertical and horizontal uni-directional air flow was carried out in a standard orthopaedic operating theatre (OT). Starting from our previous studies of a real OT under operating use conditions, in this research different air flow configurations, considering some air curtain solutions on the ceiling and at the sliding door always assumed to be open as a basic boundary condition, were investigated by numerical simulations. Indoor air quality (IAQ) indexes and thermal comfort parameters, deduced from simulation results were calculated and discussed referring to the best performance and efficacy between the air flow schemes to contrast the incorrect use conditions of the OT. Referring to the studied schemes, the reciprocal comparison emphasizes that a successful outcome in preventing surgical site infection can depend as much on resolving human factors (i.e. operational use conditions, door opening/closing), as on overcoming physical and technical obstacles.展开更多
Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categor...Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.展开更多
Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that a...Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that adapt to realtime electricity price signals formulated by demand response program and ambient temperature can significantly reduce electricity costs while ensuring occupants' comfort. However, since the pricing process and weather conditions are affected by many factors, conventional model-based method is difficult to meet the scheduling requirements in complex environments. To solve this problem, we propose an adaptive optimal scheduling strategy for residential HVAC based on deep reinforcement learning(DRL) method. The scheduling problem can be regarded as a Markov decision process(MDP). The proposed method can adaptively learn the state transition probability to make economical decision under the tolerance violations. Specifically, the residential thermal parameters obtained by the leastsquares parameter estimation(LSPE) can provide a basis for the state transition probability of MDP. Daily simulations are verified under the electricity prices and temperature data sets, and numerous experimental results demonstrate the effectiveness of the proposed method.展开更多
For sustainable development, a reduction in energy demand is essential. This could be achieved through improving energy efficiency, effective energy conservation and management. The weather conditions of a given regio...For sustainable development, a reduction in energy demand is essential. This could be achieved through improving energy efficiency, effective energy conservation and management. The weather conditions of a given region are the most important consideration for the proper design of space AC (Air Conditioning) systems. In this study, the typical meteorological year and climatic database of Turkey for the energy analysis of buildings were generated by SQL (Structured Query Language) database programmimg language. The Finkelstein-Schafer statistical method was applied to analyze the hourly measured weather data of a 23-year period (1989-2012) and select representative TMMs (Typical Meteorological Months). The selection criteria were based on 13 meteorological parameters. These parameters are the daily mean, maximum and minimum values and ranges of temperature, dew-point and wind velocity and the daily values of global solar radiation. According to results of TMY (Typical Meteorological Year), climatic database of Turkey including daily or hourly climate variables was created in SQL data tables.展开更多
Reducing heat accumulation within vehicles and ensuring appropriate vehicular temperature levels can lead to enhanced vehicle fuel economy,range,reliability,longevity,passenger comfort,and safety.Advancements in vehic...Reducing heat accumulation within vehicles and ensuring appropriate vehicular temperature levels can lead to enhanced vehicle fuel economy,range,reliability,longevity,passenger comfort,and safety.Advancements in vehicle thermal management remain key as new technologies,consumer demand,societal concerns,and government regulations emerge and evolve.This study summarizes several recent advances in vehicle thermal management technology and modeling,with a focus on three key areas:the cabin,electronics,and exterior components of vehicles.Cabin-related topics covered include methods for reducing thermal loads and improving heating,ventilation,and air-conditioning(HVAC)systems;and advancements in window glazing/tinting and vehicle surface treatments.For the thermal management of electronics,including batteries and insulated-gate bipolar transistors(IGBTs),active and passive cooling methods that employ heat pipes,heat sinks,jet impingement,forced convection,and phase-change materials are discussed.Finally,efforts to model and enhance the heat transfer of exterior vehicular components are reviewed while considering drag/friction forces and environmental effects.Despite advances in the field of vehicle thermal management,challenges still exist;this article provides a broad summary of the major issues,with recommendations for further study.展开更多
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr...This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us.展开更多
The importance and necessity of energy saving in the world have been discussed for many years,but achieving a logical and transparent solution is still one of the main challenges and problems of the world’s eco...The importance and necessity of energy saving in the world have been discussed for many years,but achieving a logical and transparent solution is still one of the main challenges and problems of the world’s economy.The rapid growth of energy consumption in the last two decades has caused the security of the domestic energy supply of buildings to face serious problems.In this research,first by entering parameters such as the type of materials,doors and windows,and the type of soil on the floor connected to the ground,etc.in the heat and cold load calculation software(HAP Carrier)as the design calculations and then in the second step entering the specifications inferred from the Iran’s national building code as a reference for energy saving calculations,calculations are performed and compared as the first criterion,and finally these two outputs are compared.The actual energy consumption and determination of the building energy consumption index are determined as another criterion,as well as the degree of deviation from the actual consumption.The results showed that the theoretical method and the thermal and refrigeration load calculations of the Zanjan Gas Company building have 6%difference in cooling load but the heating load is about 34%different,which means for cooling loads,the theoretical model can be used with high accuracy but for heating loads,the national building code needs fundamental changes.展开更多
Using an accurate energy model,this paper simulated existing commercial buildings to compare PMV-based comfort control with conventional thermostatic control and conduct a sensitivity analysis using the Design of Expe...Using an accurate energy model,this paper simulated existing commercial buildings to compare PMV-based comfort control with conventional thermostatic control and conduct a sensitivity analysis using the Design of Experiments method with monitored energy consumption data.This analysis was applied considering the impact of building envelope characteristics including thermal insulation level of exterior walls and air leakage rate on the ability of both control options to maintain indoor thermal comfort while minimizing cooling energy consumption.The analysis findings indicated that PMV-based comfort control is viable for striking a middle ground between thermal comfort and heating energy consumption with a PPD(predicted percentage of dissatisfied)level at 8%for any combination of walls’R-value and air infiltration rate while temperature-based controls result in an unacceptable indoor thermal comfort performance especially for low R-values regardless of the air infiltration rate with PPD level reaching over 76%.Also,the results show that in a comfort-controlled space,the average radioactive temperature and occupant-related features like metabolic rate and clothing level have a far bigger effect on energy use than other parameters like relative humidity.展开更多
文摘The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.
文摘Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.
文摘This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period.
文摘Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts in U.S.office buildings of multiple alternative ventilation strategies that combined:economizing,demand controlled ventilation(DCV),supply air temperature reset(SR),and/or a doubled ventilation rate.We used energy simulations in a Monte Carlo analysis,sampling 17 building inputs and varying locations to match the climate zone distribution of the U.S.office stock.Results indicated the possibility for significant savings compared to a baseline that ventilated constantly at a minimum rate in both a small office type with a constant air volume(CAV) HVAC system and a medium office type with a variable air volume(VAV) system.In 95%of instances,HVAC source energy savings were 5-25%in the small-CAV office(median:11%) and 6-42%in the medium-VAV office(median:27%).In the small-CAV office,DCV typically saved the most energy,usually from heating,and heating degree days and occupant density were decisive influences.In the medium-VAV office,economizing and SR were most important,DCV usually only had minor impacts,and zone temperature setpoints,along with climate indicators,were the critical influences.Other than infiltration,envelope characteristics did not strongly influence energy impacts.The untapped primary energy savings of alternative ventilation strategies over the 74%of U.S.office floorspace reasonably represented by our modeling was estimated at 36 TWh per year,with an annual value of U.S.$ 1.25 billion.
文摘A study on performances of different ventilation schemes provided by vertical and horizontal uni-directional air flow was carried out in a standard orthopaedic operating theatre (OT). Starting from our previous studies of a real OT under operating use conditions, in this research different air flow configurations, considering some air curtain solutions on the ceiling and at the sliding door always assumed to be open as a basic boundary condition, were investigated by numerical simulations. Indoor air quality (IAQ) indexes and thermal comfort parameters, deduced from simulation results were calculated and discussed referring to the best performance and efficacy between the air flow schemes to contrast the incorrect use conditions of the OT. Referring to the studied schemes, the reciprocal comparison emphasizes that a successful outcome in preventing surgical site infection can depend as much on resolving human factors (i.e. operational use conditions, door opening/closing), as on overcoming physical and technical obstacles.
文摘Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.
基金supported in part by the Fundamental Research Funds for the Central Universities (No. 2018JBZ004)the National Natural Science Foundation of China (No. 52007004)。
文摘Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that adapt to realtime electricity price signals formulated by demand response program and ambient temperature can significantly reduce electricity costs while ensuring occupants' comfort. However, since the pricing process and weather conditions are affected by many factors, conventional model-based method is difficult to meet the scheduling requirements in complex environments. To solve this problem, we propose an adaptive optimal scheduling strategy for residential HVAC based on deep reinforcement learning(DRL) method. The scheduling problem can be regarded as a Markov decision process(MDP). The proposed method can adaptively learn the state transition probability to make economical decision under the tolerance violations. Specifically, the residential thermal parameters obtained by the leastsquares parameter estimation(LSPE) can provide a basis for the state transition probability of MDP. Daily simulations are verified under the electricity prices and temperature data sets, and numerous experimental results demonstrate the effectiveness of the proposed method.
文摘For sustainable development, a reduction in energy demand is essential. This could be achieved through improving energy efficiency, effective energy conservation and management. The weather conditions of a given region are the most important consideration for the proper design of space AC (Air Conditioning) systems. In this study, the typical meteorological year and climatic database of Turkey for the energy analysis of buildings were generated by SQL (Structured Query Language) database programmimg language. The Finkelstein-Schafer statistical method was applied to analyze the hourly measured weather data of a 23-year period (1989-2012) and select representative TMMs (Typical Meteorological Months). The selection criteria were based on 13 meteorological parameters. These parameters are the daily mean, maximum and minimum values and ranges of temperature, dew-point and wind velocity and the daily values of global solar radiation. According to results of TMY (Typical Meteorological Year), climatic database of Turkey including daily or hourly climate variables was created in SQL data tables.
基金sponsored by the US Government under Other Transaction number W15QKN-13-9-0001 between the Consortium for Energy, Environment and Demilitarization, and the Government, with funding provided by the US Army Engineer Research & Development Center
文摘Reducing heat accumulation within vehicles and ensuring appropriate vehicular temperature levels can lead to enhanced vehicle fuel economy,range,reliability,longevity,passenger comfort,and safety.Advancements in vehicle thermal management remain key as new technologies,consumer demand,societal concerns,and government regulations emerge and evolve.This study summarizes several recent advances in vehicle thermal management technology and modeling,with a focus on three key areas:the cabin,electronics,and exterior components of vehicles.Cabin-related topics covered include methods for reducing thermal loads and improving heating,ventilation,and air-conditioning(HVAC)systems;and advancements in window glazing/tinting and vehicle surface treatments.For the thermal management of electronics,including batteries and insulated-gate bipolar transistors(IGBTs),active and passive cooling methods that employ heat pipes,heat sinks,jet impingement,forced convection,and phase-change materials are discussed.Finally,efforts to model and enhance the heat transfer of exterior vehicular components are reviewed while considering drag/friction forces and environmental effects.Despite advances in the field of vehicle thermal management,challenges still exist;this article provides a broad summary of the major issues,with recommendations for further study.
文摘This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us.
文摘The importance and necessity of energy saving in the world have been discussed for many years,but achieving a logical and transparent solution is still one of the main challenges and problems of the world’s economy.The rapid growth of energy consumption in the last two decades has caused the security of the domestic energy supply of buildings to face serious problems.In this research,first by entering parameters such as the type of materials,doors and windows,and the type of soil on the floor connected to the ground,etc.in the heat and cold load calculation software(HAP Carrier)as the design calculations and then in the second step entering the specifications inferred from the Iran’s national building code as a reference for energy saving calculations,calculations are performed and compared as the first criterion,and finally these two outputs are compared.The actual energy consumption and determination of the building energy consumption index are determined as another criterion,as well as the degree of deviation from the actual consumption.The results showed that the theoretical method and the thermal and refrigeration load calculations of the Zanjan Gas Company building have 6%difference in cooling load but the heating load is about 34%different,which means for cooling loads,the theoretical model can be used with high accuracy but for heating loads,the national building code needs fundamental changes.
文摘Using an accurate energy model,this paper simulated existing commercial buildings to compare PMV-based comfort control with conventional thermostatic control and conduct a sensitivity analysis using the Design of Experiments method with monitored energy consumption data.This analysis was applied considering the impact of building envelope characteristics including thermal insulation level of exterior walls and air leakage rate on the ability of both control options to maintain indoor thermal comfort while minimizing cooling energy consumption.The analysis findings indicated that PMV-based comfort control is viable for striking a middle ground between thermal comfort and heating energy consumption with a PPD(predicted percentage of dissatisfied)level at 8%for any combination of walls’R-value and air infiltration rate while temperature-based controls result in an unacceptable indoor thermal comfort performance especially for low R-values regardless of the air infiltration rate with PPD level reaching over 76%.Also,the results show that in a comfort-controlled space,the average radioactive temperature and occupant-related features like metabolic rate and clothing level have a far bigger effect on energy use than other parameters like relative humidity.