Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c...Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities.展开更多
The experimental muon source on China Spallation Neutron Source(CSNS) is expected to be a high intensity(105μ+/s) surface muon source with a small beam spot of 4-cm diameter.For a practical application of this muon s...The experimental muon source on China Spallation Neutron Source(CSNS) is expected to be a high intensity(105μ+/s) surface muon source with a small beam spot of 4-cm diameter.For a practical application of this muon source,we are devoting to develop the first pulsed μSR spectrometer in China.In this paper,the performance of plastic scintillators in the μSR spectrometer is studied by Monte Carlo simulation.The processes such as positron energy deposition,scintillation photons production,light propagation and photon-electron conversion are carefully considered.According to the results,an optimal dimension of the plastic scintillator is proposed using for our future spectrometer,which has a long-strip shape with the dimension variation range of 50–60 mm length,5–8 mm height,and 10–12 mm width.Finally,we can build a spectrometer with a count rate up to 104e+/s by 100–120 forward and backward segmental detectors in total.The simulation could serve as an important guide for spectrometer construction.展开更多
Near-infrared (NIR) spectrometer based on semiconductor lasers can combine light source and splitter into one, which is an important direction for development of miniature instruments. In order to avoid random interfe...Near-infrared (NIR) spectrometer based on semiconductor lasers can combine light source and splitter into one, which is an important direction for development of miniature instruments. In order to avoid random interference caused by inconsistency between light sources, the novel evaluation indicators for global stability of multi-channels spectral system were proposed based on the correlation between dynamic deviation spectra of any two channels. The NIR analysis of moisture for corn powder samples based on the partial least squares combined with Savitzky-Golay (SG) smoothing was taken as an example, and a spectral correction method for enhancing prediction performance of multi-channels spectral system was further provided using above evaluation indicators. The experiment results showed that the global stability evaluation indicators significantly increased after SG smoothing correction. Meanwhile, the root-mean-square errors of prediction for corn moisture reduced from 0.373 to 0.283 (%), and the correlation coefficient between predicted and actual values was improved from 0.702 to 0.855. The above results indicated that by improving global stability indicators, the prediction ability of multi-channels spectral system can be improved. The proposed method provided a valuable reference for designing multi-channels diminutive spectrometer with high prediction performance, which had significance for large-scale application of NIR technology.展开更多
基金partially supported by the Natural Science Foundation of China(Nos.12004353,11975214,11991071,11905202,12175212,and 12120101005)the Key Laboratory Foundation of the Science and Technology on Plasma Physics Laboratory(Nos.6142A04200103 and 6142A0421010).
文摘Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities.
基金Supported by National Natural Science Foundation of China(No.11075154)
文摘The experimental muon source on China Spallation Neutron Source(CSNS) is expected to be a high intensity(105μ+/s) surface muon source with a small beam spot of 4-cm diameter.For a practical application of this muon source,we are devoting to develop the first pulsed μSR spectrometer in China.In this paper,the performance of plastic scintillators in the μSR spectrometer is studied by Monte Carlo simulation.The processes such as positron energy deposition,scintillation photons production,light propagation and photon-electron conversion are carefully considered.According to the results,an optimal dimension of the plastic scintillator is proposed using for our future spectrometer,which has a long-strip shape with the dimension variation range of 50–60 mm length,5–8 mm height,and 10–12 mm width.Finally,we can build a spectrometer with a count rate up to 104e+/s by 100–120 forward and backward segmental detectors in total.The simulation could serve as an important guide for spectrometer construction.
文摘Near-infrared (NIR) spectrometer based on semiconductor lasers can combine light source and splitter into one, which is an important direction for development of miniature instruments. In order to avoid random interference caused by inconsistency between light sources, the novel evaluation indicators for global stability of multi-channels spectral system were proposed based on the correlation between dynamic deviation spectra of any two channels. The NIR analysis of moisture for corn powder samples based on the partial least squares combined with Savitzky-Golay (SG) smoothing was taken as an example, and a spectral correction method for enhancing prediction performance of multi-channels spectral system was further provided using above evaluation indicators. The experiment results showed that the global stability evaluation indicators significantly increased after SG smoothing correction. Meanwhile, the root-mean-square errors of prediction for corn moisture reduced from 0.373 to 0.283 (%), and the correlation coefficient between predicted and actual values was improved from 0.702 to 0.855. The above results indicated that by improving global stability indicators, the prediction ability of multi-channels spectral system can be improved. The proposed method provided a valuable reference for designing multi-channels diminutive spectrometer with high prediction performance, which had significance for large-scale application of NIR technology.