期刊文献+
共找到13,425篇文章
< 1 2 250 >
每页显示 20 50 100
Calculation of Mass Concrete Temperature Containing Cooling Water Pipe Based on Substructure and Iteration Algorithm
1
作者 Heng Zhang Chao Su +2 位作者 Zhizhong Song Zhenzhong Shen Huiguang Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期813-826,共14页
Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for... Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development. 展开更多
关键词 Fourier equation cooling water pipe mass concrete iteration algorithm
下载PDF
Design and analysis of a high loss density motor cooling system with water cold plates
2
作者 Xin Zhao Haojie Cui +2 位作者 Yun Teng Zhe Chen Guangwei Liu 《Global Energy Interconnection》 EI CSCD 2023年第3期343-354,共12页
Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect o... Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor. 展开更多
关键词 cooling system design High loss density motor water cold plate Temperature field analysis
下载PDF
Experimental Study on the Resistance and Splash Performances of Water Collecting Devices for Mechanical Draft Cooling Towers
3
作者 Guoqing Long Guogang Zhang +3 位作者 Qi Zhang Cuilin Zhao Suoying He Fengzhong Sun 《Fluid Dynamics & Materials Processing》 EI 2023年第7期1789-1801,共13页
In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To ex... In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To explore the feasibility of this approach for mechanical draft cooling towers,a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices(WCDs)for different water flow rates and wind speeds.The experimental results show that within the considered ranges of wind speed and water flow rate,the pressure drop of the different WCDs can vary significantly.The resistance and local splash performances can also be remarkably different.Some recommendations about the most suitable system are provided.Moreover,a regression analysis of the experimental data is conducted,and the resulting fitting formulas for resistance and splash performance of WCD are reported. 展开更多
关键词 Mechanical draft cooling towers water collecting device resistance performance splash performance fitting formulas
下载PDF
Corrosion Inhibition by Co-Immobilized Lysozyme and Lipase in Circulating Cooling Water System 被引量:3
4
作者 Liu Fang Lü Yucui +3 位作者 Jiang Guofei Chen Xiaorui Sun Juan Zhao Chaocheng 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2017年第2期21-32,共12页
The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters wer... The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%. 展开更多
关键词 CIRCULATING cooling water CO-IMMOBILIZATION LYSOZYME LIPASE corrosion INHIBITION
下载PDF
Effects of Nutrients on Biofouling Formation and Preponderant Bacteria Diversity in Recirculating Cooling Water System 被引量:2
5
作者 Ma Tao Liu Fang +1 位作者 Zhang Guizhi Zhao Chaocheng (College of Chemistry and Chemical Engineering,China University of Petroleum,Qingdao 266555) 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2010年第4期57-62,共6页
A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation an... A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one. 展开更多
关键词 recirculating cooling water BIOFOULING numerical analysis polymerase chain reaction
下载PDF
Laccase Immobilized on Mesoporous Silica Materials and Its Corrosion Inhibition Performance in Circulating Cooling Water System 被引量:2
6
作者 Liu Fang Lü Yucui +3 位作者 Zhong Huiyun Zhang Shuang Fan Fengtao Zhao Chaocheng 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2015年第4期8-19,共12页
Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter... Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter is 2.55 nm, while the specific surface area is 1 088.9 m2/g. Mesoporous SiO_2 microspheres adsorb glutaraldehyde and immobilize laccase by means of the aldehyde group in glutaral which can react with the amidogen of laccase. The immobilization conditions were optimized at a glutaraldehyde concentration of 0.75%, a crosslinking time of 8 h, a laccase concentration of 0.04 L/L and an immobilization time of 10 h. When diesel leakage concentration was 80 mg/L, the highest corrosion inhibition efficiency of immobilized laccase reached 49.23%, which was slightly lower than the corrosion inhibition efficiency of free laccase(59%). The diesel degradation ratio could reach up to 45%. It has been proved that the immobilized laccase could degrade diesel to inhibit corrosion. 展开更多
关键词 diesel leakage circulating cooling water mesoporous SiO_2 microspheres laccase immobilization corrosion inhibition
下载PDF
Design and operation problems related to water curtain system forunderground water-sealed oil storage caverns 被引量:5
7
作者 Zhongkui Li Baoqi Lu +2 位作者 Jing Zou Bin Xu Zhizeng Zhang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2016年第5期689-696,共8页
The underground water-sealed storage technique is critically important and generally accepted for the national energy strategy in China. Although several small underground water-sealed oil storage caverns have been bu... The underground water-sealed storage technique is critically important and generally accepted for the national energy strategy in China. Although several small underground water-sealed oil storage caverns have been built in China since the 1970s, there is still a lack of experience for large-volume underground storage in complicated geological conditions. The current design concept of water curtain system and the technical instruction for system operation have limitations in maintaining the stability of surrounding rock mass during the construction of the main storage caverns, as well as the long-term stability. Although several large-scale underground oil storage projects are under construction at present in China, the design concepts and construction methods, especially for the water curtain system, are mainly based on the ideal porosity medium flow theory and the experiences gained from the similar projects overseas. The storage projects currently constructed in China have the specific features such as huge scale, large depth, multiple-level arrangement, high seepage pressure, complicated geological conditions, and high in situ stresses, which are the challenging issues for the stability of the storage caverns. Based on years’ experiences obtained from the first large-scale (millions of cubic meters) underground water-sealed oil storage project in China, some design and operation problems related to water curtain system during project construction are discussed. The drawbacks and merits of the water curtain system are also presented. As an example, the conventional concept of “filling joints with water” is widely used in many cases, as a basic concept for the design of the water curtain system, but it is immature. In this paper, the advantages and disadvantages of the conventional concept are pointed out, with respect to the long-term stability as well as the safety of construction of storage caverns. Finally, new concepts and principles for design and construction of the underground water-sealed oil storage caverns are proposed. 展开更多
关键词 Underground water-sealed oil storage caverns water curtain system Design concept and method Cavern stability and safety
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
8
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation water for energy production Net metering
下载PDF
Cooling and Optimization in the Groove of the Outer Rotor HubMotor
9
作者 Zhuo Liu Yecui Yan 《Frontiers in Heat and Mass Transfer》 EI 2024年第5期1443-1460,共18页
The external rotor hub motor adopts direct drive mode,no deceleration drive device,and has a compact structure.Its axial size is smaller than that of a deceleration-driven hub motor,which greatly reduces the weight of... The external rotor hub motor adopts direct drive mode,no deceleration drive device,and has a compact structure.Its axial size is smaller than that of a deceleration-driven hub motor,which greatly reduces the weight of the vehicle and increases the cruising range of the vehicle.Because of the limited special working environment and performance requirements,the hub motor has a small internal space and a large heat generation,so it puts forward higher requirements for heat dissipation capacity.For the external rotor hub motor,a new type of in-tank watercooled structure of hub motor was proposed to improve its cooling effect and performance.Firstly,the threedimensional finite element model of the motor is established to analyze the characteristics of motor loss and temperature field distribution.Secondly,the cooling performance of different cooling structures in the tank was studied.Finally,the thermal network model and three-dimensional finite element analysis were used to optimize the water-cooled structure in the tank,and the power density of themotor was improved by improving the cooling performance under the condition of volume limitation of the hub motor.The results show that the cooling effect of the proposed water-cooled structure in the tank is significant under the condition of constant power density.Compared to natural ventilation,the maximum temperature was reduced by 33.13°C and the cooling effect was increased by about 27.7%. 展开更多
关键词 Outer rotor hub motor temperature field water cooling in the tank motor loss thermal networks high torque density
下载PDF
Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water 被引量:3
10
作者 李金波 翟文 +1 位作者 郑茂盛 朱杰武 《Journal of Pharmaceutical Analysis》 SCIE CAS 2008年第1期33-37,60,共6页
The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarizati... The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times. 展开更多
关键词 stainless steel TEMPERATURE chloride ions sulfide ions simulated cooling water
下载PDF
Application of a water cooling treatment and its effect on coal-based reduction of high-chromium vanadium and titanium iron ore 被引量:2
11
作者 Song-tao Yang Mi Zhou +3 位作者 Tao Jiang Shan-fei Guan Wei-jun Zhang Xiang-xin Xue 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第12期1353-1359,共7页
A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), ... A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (Rs), and P removal ratio (Rp) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350℃ were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, Rs, and Rp in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350℃, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation. 展开更多
关键词 MAGNETITE ore reduction water cooling METALLIZATION magnetic separation
下载PDF
Optimization of circulating cooling water systems based on chance constrained programming 被引量:3
12
作者 Bo Liu Yufei Wang Xiao Feng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期167-178,共12页
Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained u... Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%). 展开更多
关键词 Circulating cooling water system UNCERTAINTY Chance constrained programming DESIGN OPTIMIZATION SIMULATION
下载PDF
MIC in Circulating Cooling Water System 被引量:1
13
作者 Ping Xu Zhaoyi Xu +2 位作者 Jin Wang Yajun Zhang Li Zhang 《Journal of Water Resource and Protection》 2012年第4期203-206,共4页
MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of mic... MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper. 展开更多
关键词 CIRCULATING cooling water system MIC MICROORGANISMS SPECIES MECHANISM Of MIC Control Methods
下载PDF
Simulation of Gas-Fired Triple-Effect LiBr/Water Absorption Cooling System with Exhaust Heat Recovery Generator 被引量:1
14
作者 汪磊磊 由世俊 +1 位作者 张欢 李宪莉 《Transactions of Tianjin University》 EI CAS 2010年第3期187-193,共7页
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no... An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles. 展开更多
关键词 LiBr/water triple-effect absorption cooling cycle exhaust heat recovery
下载PDF
Ion Exchange Softening and Alkalization Treatment for Zerodischarge of Circulating Cooling Water 被引量:1
15
作者 Huiming Zeng Jiuyang Lin +3 位作者 Chunsong Ye Lihui Tong Xiaolan Chen Fei Yu 《Journal of Electromagnetic Analysis and Applications》 2009年第1期6-10,共5页
In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkaliza... In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkalization process to solve these problems and carries out a series of studies to study the feasibility of ion exchange softening and alkaliza-tion process in the simulation process of circulating cooling water system. The studies include product water quality of ion exchange softening and alkalization process, effect on the performance of carbon steel and brass, and the inhibition that suppresses microbial growth. The results indicate that ion exchange softening and alkalization process is feasible to prevent the circulating cooling water system from scaling, pipe corrosion, and microbial growth without any other chemicals. Thus circulating cooling water system can achieve zerodischarge of wastewater. 展开更多
关键词 ION EXCHANGE SOFTENING and ALKALIZATION CIRCULATING cooling water Zerodischarge
下载PDF
CFD Analysis and Optimization of a Diesel Engine Cooling Water Jacket 被引量:1
16
作者 Shunshun Qin Chengfen Xie +3 位作者 Song Li Qi Yang Jianwei Chen Ke Sun 《Fluid Dynamics & Materials Processing》 EI 2022年第3期647-659,共13页
The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.... The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail. 展开更多
关键词 Diesel engine cooling water jacket CFD
下载PDF
Energy, Exergy and Thermoeconomics Analysis of Water Chiller Cooler for Gas Turbines Intake Air Cooling 被引量:1
17
作者 Galal Mohammed Zaki Rahim Kadhim Jassim Majed Moalla Alhazmy 《Smart Grid and Renewable Energy》 2011年第3期190-205,共16页
Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the... Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff. 展开更多
关键词 Gas Turbine EXERGY Analysis Power BOOSTING Hot Climate Air cooling water CHILLER
下载PDF
Structural Design and Performance Analysis of a Deep-Water Ball Joint Seal 被引量:2
18
作者 Yongjun Hou Qian Tang +1 位作者 Zhixing Wu Xiaoming Liu 《Journal of Marine Science and Application》 CSCD 2018年第2期224-232,共9页
To overcome the current difficulties of high-precision machining and the high manufacturing and maintenance costs of spherical seals for deep-water drilling ball joints,a new spherical seal technique is proposed in th... To overcome the current difficulties of high-precision machining and the high manufacturing and maintenance costs of spherical seals for deep-water drilling ball joints,a new spherical seal technique is proposed in this paper.The spherical seal is mainly composed of silicone rubber and polytetrafluoroethylene(PTFE).Rational structural design makes the seal independent from the ball and other components,making it easy to replace if leakage occurs at its surface.PTFE can elastically deform over a certain deformation range,which guarantees that two sealing surfaces fit tightly together.O-Ring and PTFE elasticity makes up for any lack of accuracy during spherical machining and decreases the machining precision requirements for spherical surfaces.Using a finite element technique and nonlinear theory,the performance of the spherical seal under the influence of various factors is determined.The results show that the spherical seal designed in this paper exhibits excellent sealing performance under lowtemperature and high-pressure conditions.The spherical seal,a combination of an O-ring and PTFE,has the advantages of cheap manufacturing and maintenance costs and excellent sealing performance. 展开更多
关键词 DEEP-water DRILLING BALL joint SPHERICAL seal Nonlinear theory Finite element technique sealING performance
下载PDF
Flow Field and Temperature Field of Water-Cooling-Type Magnetic Coupling 被引量:2
19
作者 Lei Wang Zhenyuan Jia +1 位作者 Yuqin Zhu Li Zhang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2019年第4期61-72,共12页
At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rota... At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rotating watercooled coupling of the coupler. Focusing on rotating water cooling radiating, the present paper proposes simulating the water cooling temperature field as well as the flow field through the method of combining fluid-solid coupled heat transfer and MRF(Multiphase Reference Frame). In addition, taking an 800 kW magnetic coupling as an example, the paper optimizes the shape, number, cooling water inlet speed? and so on? of the cooling channel. Considering factors such as the complete machine’s temperature, and drag torque, it is proved that the cooling e ect is best when there are 36 involute curved channels and when the inlet speed is 3 m/s. Further, through experiments, the actual temperature values at six di erent positions when 50 kW and 70 kW thermal losses di er are measured. The measured values agree with the simulation results, proving the correctness of the proposed method. Further, data have been collected during the entire experimental procedure? and the variation in the coupling’s temperature is analyzed in depth, with the objective of laying a foundation for the estimation of the inner temperature rise as well as for the optimization of the structural design. 展开更多
关键词 water-cooling MAGNETIC COUPLING Fluid-solid COUPLING Channel Three-dimensional TEMPERATURE FIELD
下载PDF
Corrosion Prevention of the Generator Stator Hollow Copper Conductor and Water Quality Adjustment of Its Internal Cooling Water 被引量:2
20
作者 Ling PAN Qianqian HAN +2 位作者 Xuenong XIE Xuejun XIE Peng XIAO 《Energy and Power Engineering》 2009年第1期17-20,共4页
On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling gene... On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed. 展开更多
关键词 GENERATOR INTERNAL cooling-water HOLLOW COPPER conductor corrosion and protection
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部